Remembrance: Worcester Cold Storage Tragedy

No comments

Worcester Cold Storage Tragedy

On December 3, 1999, a five-alarm fire at the Worcester Cold Storage & Warehouse Co. building claimed the lives of six brave firefighters who responded to the call. These six heros, The Worcester 6, sacrificed their lives to try and rescue two individuals who were believed to be trapped inside the inferno. May the Worcester 6 always be remembered; “Fallen Heroes Never Forgotten.”

Firefighter Paul A. Brotherton
Firefighter
Paul A. Brotherton
Firefighter Timothy P. Jackson
Firefighter
Timothy P. Jackson
Firefighter Jeremiah M. Lucey
Firefighter
Jeremiah M. Lucey
Firefighter James F. Lyons
Firefighter
James F. Lyons
Firefighter Joseph T. McGuirk
Firefighter
Joseph T. McGuirk
Lieutenant Thomas E. Spencer
Lieutenant
Thomas E. Spencer

Predictability and Performance Of Buildings and Today’s Fireground

No comments

Understanding the distinctiveness of your first-due, mutual aid or greater-alarm response area requires constant vigilance and continuous observations. Building knowledge equals firefighter safety. Photo By CJ Naum

 

When we look at various buildings and occupancies, past operations (good and bad) give us experience that defines and determines how we assess, react and expect similar structures and occupancies to perform at a given alarm. The “art and science of firefighting” is predicated on a fundamental understanding of how fire affects a building and its occupants and the manner in which the fire service engages when called on to combat a structure fire.

We have certain expectations that fire will travel in a defined, predictable manner:

  •  That the building will react and perform under assumptions of past performance and outcomes
  • That fire will hold within a room and compartment for a predictable duration
  • That the fire load and related fire flows required will be appropriate for an expected size and severity of fire encountered within a given building, occupancy or structural system
  • That we can safely and effectively mitigate a fire in any given building type and occupancy
  • That we will have the time to conduct the required tasks identified to be of importance based on identified or assumed indicators
  • That the building will conform to the rules of firefighting engagement

Times have changed

Today’s incident demands on the fireground are unlike those of even the recent past. This means incident commanders, commanding and company officers and firefighters alike must have increased technical knowledge of building construction with a heightened sensitivity of fire behavior and fire dynamics, a focus on operational structural stability of the compartment and building envelope and considerations related to occupancy risk versus the occupancy type. Understanding the building – its complexities in terms of anatomy, structural systems, materials, configuration, design, layout, systems, methods of construction, engineering and inherent features, limitations, challenges and risks – is fundamental for operational excellence on the fireground and firefighter safety.

There is an immediate need for emerging and operating command and company officers to increase their knowledge and insights of modern building occupancy, building construction and fire protection engineering and to modify traditional and conventional strategic operating profiles in order to safeguard companies, personnel and team compositions. Strategies and tactics must have the combined adequacy of sufficient staffing, fire flow and tactical patience orchestrated in a manner that identifies with the fire profiling, predictability of the occupancy and the building that accounts for presumptive fire behavior.

We used to discern with a measured degree of predictability how buildings would perform and fail under most fire conditions. Implementing fundamentals of firefighting operations built on decades of time-tested and experience-proven strategies and tactics continues to be the model of suppression operations. These same fundamental strategies continue to drive methodologies and curriculums in current training programs and academy instruction.

We must maintain a balance with learning about old and new building construction. A renewed focus on Type III, Ordinary /Protected construction and Type IV Heavy Timber must be incorporated within initial, in-service and periodic training and drills. Recent firefighter LODD events in these building types reinforces this need and gap. Photo By CJ Naum

Increasing company and command officer competencies in Building Anatomy, structural systems and how buildings are built and affected by fire behavior is fundamental to effective fireground operations. Interdependent structural components are evident for wall, floor and support assemblies in this Type IV occupancy. Do you know the inherent collapse potential of these buildings? Photo by CJ Naum

We have assumed that the routiness or successes of past operations and incident responses equates with predictability and diminished risk to our firefighting personnel. Photo By CJ Naum

 

Our current generation of buildings, construction and occupancies are not as predictable as past conventional construction, therefore risk assessment, strategies and tactics must change to address these new rules of combat structural fire engagement. Photo by CJ Naum

Executing tactical plans based on faulty or inaccurate strategic insights and indicators has proven to be a common apparent cause in numerous case studies, after-action accounts and firefighter line-of-duty-death reports. Our years of predictable fireground experience have ultimately embedded and clouded our ability to predict, assess, plan and implement Incident Action Plans (IAPs).

The demands of modern firefighting will continue to require the placement of personnel in situations and buildings that carry risk, uncertainty and inherent danger. As a result, risk management must become fluid and integrated with intelligent tactical deployments and operations.

 Managing Risk

“If you don’t fully understand how a building truly performs or reacts under fire conditions and the variables that can influence its stability and degradation, movement of fire and products of combustion and the resource requirements for smart aggressive fire suppression in terms of staffing, apparatus and required fire flows, then you will be functioning and operating in a reactionary manner that is no longer acceptable within many of our modern building types, occupancies and structures. This places higher risk to your personnel and lessens the likelihood for effective, efficient and safe operations. You’re just not doing your job effectively and you’re at risk. These risks can equate into insurmountable operational challenges and could lead to adverse incident outcomes. Someone could get hurt, someone could die; it’s that simple, it’s that obvious.”

Those are the words of Chief Anthony Aiellos (ret.) of the Hackensack, NJ, Fire Department on the 20th anniversary of the Hackensack Ford dealership fire that killed five firefighters in 1988. Without understanding building-occupancy relationships and integrating fire dynamics and fire behavior, risk, analysis, the art and science of firefighting, safety-conscious work environment concepts and effective and well-informed incident management, company-level supervision and task-level competencies, you are derelict and negligent and everyone may not be going home. Empirical insights and test data must be integrated in emerging fire suppression models and improved firefighting theory.

It’s Occupancy Risk versus Occupancy Type; Changes in building size and floor area, compartment volume and interconnectivity, fire load packages, methods and materials in construction and structural support systems create specific risk profiles and demands in what used to be common Occupancy types. A report of a fire in a residential occupancy will have different risks and operational requirements if the house is a 1500 SF Bungalow, a 2500 SF old Decker/Flat or a 4000 SF Engineered system house. Photo By CJ Naum

 

Conclusion

Our world has evolved. Technological and sociological demands create a continuing element of change in the built environment and our infrastructure. With these changes and demands come the need to assess these vulnerabilities, hazards and threats with effective and dynamic risk management and competent command and control.

These changes influence the way we do business in the street, the interface-up close and personal with the buildings in your community and equate to the risks and hazards you and your personnel will be confronted with and the level of safety afforded them during incident operations.

Fire suppression tactics must be adjusted for the rapidly changing methods and materials impacting all forms of building construction, occupancies and structures. The need to redefine the art and science of firefighting is nearly upon us. Some things do stand the test of time, others need to adjust, evolve and change. Not for the sake of change only, but for the emerging and evolving buildings, structures and occupancies being built, developed or renovated in our communities.

If the fire service can significantly increase proficiencies in building knowledge and equate that to other fundamental operational aspects in structural fire operations, then there would be a direct enhancement to firefighter safety, through injury and LODD reduction, operational efficiency and operational excellence. If we understand buildings, occupancies and construction, and balance this with our understanding of fire dynamics and orchestrate it with appropriate strategies, tactics and command management, then we made the new safety equation work; Building Knowledge = Firefighter Safety (Bk=F2S). It’s all about the Anatomy of Buildings on fire.

 

The Probability of Adverse Consequences (PAC) must be recognized in all buildings with continuous and focused risk assessment during all phases and task assignments. This single building and occupancy exemplifies an Integrated Hybrid Building (IHB) type that incorporates Type III Ordinary construction with an engineered wood I-beam roof assembly on the lower street level and Type II non-combustible construction on the upper floors. This would require different IAP’s and tactical deployment in the event of a fire. Photo by CJ Naum

Get out on to your streets and into the field and look at how the buildings are being constructed in your jurisdiction. Understanding how they are built and what the inherent dangers are, coupled with accurate pre-fire planning data will provide mission critical information when engaged in combat fire suppression operations. The anatomy of the building is fundamental to corresponding firefighting operations. Photo by CJ Naum

 

Understanding Buildings, Performance & Fire Operations

  • There is an acute corollary of technical  knowledge and inter reliance on occupancies, construction, strategy, tactics, risk, safety, physics, engineering and fire suppression theory…FACT!
  • There are Fundamental Domains that can be applied
  • There is a direct empirical correlation that provides quantitative & qualitative performance indicators and command gauges that can be utilized for risk assessment and strategic & tactical operational decision-making. 

Think about the following;

  • Read, comprehend and implement the new IAFC The Rules of Engagement for Firefighter Survival and The Incident Commanders Rules of Engagement for Firefighter Safety
  • Take a tour of your response area, district or community. Take a good look around and begin to recognize the apparent or subtle changes that will affect and influence your future incident operations; Take note and think about what needs to be adjusted, modified or changed in your operations.
  • Read up on the latest research and technical literature on wind driven fires, extreme fire behavior, structural ability of engineered lumber systems, fire loading and suppression theory, vent path studies and fire suppression theory.
  • Take the time to personally read a series of the latest NIOSH Fire Fighter Fatality Investigation and Prevention Program LODD reports and relate them to your organizations operations and jurisdictional risks.
  • Start thinking in terms of Occupancy Risks versus Occupancy Type and align your operations and deployments to match those risks. It’s much more than just the Five Fundamental Building Types of the past.
  • Increase your situational awareness of today’s fireground and refine your strategic and tactical modeling.
  • Implement both Strategic and Tactical Patience; Slow down and allow the building to react and stabilize, for fire behavior to stop behaving badly and for your companies to increase survivability ratios while meeting the demands of  conducting time sensitive tactical fire service operations
  • Think about Adaptive Fireground Management and Command Resiliency
  • Reprogram your assumptions and presumptions and options on building construction and firefighting operations; the buildings have changed, our firefighting has not; what are you going to about that gap?  
  • Understanding the building-occupancy relationships and the art and science of firefighting, equating to Building Knowledge = Firefighter Safety.
  • Start knowing your buildings-intimately; it’s the key to effective firefighting

 Understand the buildings and occupancies not only in your jurisdiction, first or second-due areas, but also in those areas that you may be called upon to respond to for greater alarms or mutual aid. Remember Building Knowledge = Firefighter Safety.

Understand and improve upon your skill set levels and those of your company, battalion, division, department or region.

  • Keep apprised of different types of building materials and construction used in your community.
  • The operative question is this: “What do you “really” know about the buildings in your district?”
  • As you drive about your response district, coming back from an alarm, heading to the firehouse tonight or running errands around your community, take a good look around. Ask yourself a simple question; “How well do you know the buildings, structures and occupancies in your response jurisdiction?”
  • Be honest, do you really understand how those “older residential” structures were built and understand how fire travels and impacts your fireground operations?
  • Are your aware of the newest features of engineered structural support systems being constructed within that new set of homes going up in your second-due area?
  • Are you aware, that vacant office building is being converted into a light manufacturing and assembly business?
  • How about those unoccupied store fronts and businesses that have recently closed up due to the tough economic times…. any special hazards or operational concerns to your company should you get a dispatch to respond?
  • Have the senior members of your station or department shared their stories of operations and incidents at various buildings around your district or community?
  • Did you listen to them, or were you quick to dismiss those “old war stories”. There’s a wealth of “pre-planning’ nuggets hidden in those stories. Take the time to listen, remember or postulate
  • Take a good look around….think about any given building, the one across the street that you’re looking at while you waited for the traffic light to change; Think about a fire in that same building.
  • Do you really understand how it will truly perform under combat structural fire conditions?
  • What’s the building’s collapse profile?
  • How much operational time will you have? Will you need?
  • What’s the fire load package size?
  • What are your concerns for rapid fire extension, extreme fire behavior and vent path issues that may affect firefighter safety?
  • What dynamic risk assessment factors will you have to deal with?
  • How safe is it for you to engage in interior operations upon your arrival?
  • How can this building, its occupancy and structural system hurt, my team, my company, my firefighters, my department, me?

 

Never assume the same rules of structural fire engagement can be applied to all buildings without constant risk assessment, recon and situational awareness. Strategies and tactics must remain fluid. This single story commercial occupancy looked like a basic renovated Type III building from the street. An exposed (minimal design) interior accompanied by a non-conventional bow string truss support system and a raftered roof deck are ingredients for catastrophe for the unsuspecting Engine or Truck Companies. Photo by CJ Naum

 

 

Keep an eye in the rear view mirror; learning from the wisdom and knowledge from where you’ve been, what you’ve done and all your past experiences and practice; but at the same time focusing on the road before you with keen attentiveness on situational awareness, anticipating error-likely conditions and balanced risk assessment and operational management in both your strategic and tactical deployments.

 

Ensure you’re glancing occasionally in your rear view mirror to monitor where you’ve been, while driving your initiatives, programs, processes and actions forward. Above all, maintain the courage to be safe and know and understand your buildings, occupancies and your company’s capabilities.

 

 

 

 

 

 

 

Remembrance: Worcester Cold Storage Warehouse Fire and the Worcester Six

No comments

Today December 3, 2011 marks the 12th anniversary of the Worcester Cold Storage Warehouse fire that resulted in the line of duty death of six courages brother firefighters.   

For those of you who remember this event, take the time to reflect and honor the sacrifice made this day; to those of you who have not heard about the fire before- take the time to learn about the incident, the firefighters, the building, the operational factors and challenges, the courage, fortitude and convictions that define the American Fire Service, it’s honor, tradition and brotherhood.   

The Worcester Six;   

  • Firefighter Paul Brotherton Rescue 1
  • Firefighter Jeremiah Lucey Rescue 1
  • Lieutenant Thomas Spencer Ladder 2
  • Firefighter Timothy Jackson Ladder 2
  • Firefighter James Lyons Engine 3
  • Firefighter Joseph McGuirk Engine

   

On Friday, December 3, 1999, at 1813 hours, the Worcester, Massachusetts Fire Department dispatched Box 1438 for 266 Franklin Street, the Worcester Cold Storage and Warehouse Co. A motorist had spotted smoke coming from the roof while driving on an adjacent elevated highway. The original building was constructed in 1906, contained another 43,000 square feet. Both were 6 stories above grade. The building was known to be abandoned for over 10 years.   

   

Worcester Cold Storage Warehouse Fire 1999

3 comments

Today December 3, 2010 marks the 11th anniversary of the Worcester Cold Storage Warehouse fire that resulted in the line of duty death of six courages brother firefighters.   

For those of you who remember this event, take the time to reflect and honor the sacrifice made this day; to those of you who have not heard about the fire before- take the time to learn about the incident, the firefighters, the building, the operational factors and challenges, the courage, fortitude and convictions that define the American Fire Service, it’s honor, tradition and brotherhood.   

The Worcester Six;   

  • Firefighter Paul Brotherton Rescue 1
  • Firefighter Jeremiah Lucey Rescue 1
  • Lieutenant Thomas Spencer Ladder 2
  • Firefighter Timothy Jackson Ladder 2
  • Firefighter James Lyons Engine 3
  • Firefighter Joseph McGuirk Engine

   

On Friday, December 3, 1999, at 1813 hours, the Worcester, Massachusetts Fire Department dispatched Box 1438 for 266 Franklin Street, the Worcester Cold Storage and Warehouse Co. A motorist had spotted smoke coming from the roof while driving on an adjacent elevated highway. The original building was constructed in 1906, contained another 43,000 square feet. Both were 6 stories above grade. The building was known to be abandoned for over 10 years.   

Due to these and other factors, the responding District Chief ordered a second alarm within 4 minutes of the initial dispatch. The first alarm assignment brought 30 firefighters and officers and 7 pieces of apparatus to the scene. The second provided an additional 12 men and 3 trucks as well as a Deputy Chief. Firefighters encountered a light smoke condition throughout the warehouse, and crews found a large fire in the former office area of the second floor. An aggressive interior attack was started within the second floor and ventilation was conducted on the roof. There were no windows or other openings in the warehousing space above the second floor.   

Eleven minutes into the fire, the owner of the abutting Kenmore Diner advised fire operations of two homeless people who might be living in the warehouse. The rescue company, having divided into two crews, started a building search. Some 22 minutes later the rescue crew searching down from the roof became lost in the vast dark spaces of the fifth floor. They were running low on air and called for help. Interior conditions were deteriorating rapidly despite efforts to extinguish the blaze, and visibility was nearly lost on the upper floors. Investigators have placed these two firefighters over 150 feet from the only available exit.   

Copywrite 1999 Roger B. Conant All Rights Reserved

An extensive search was conducted by Worcester Fire crews through the third and fourth alarms. Suppression efforts continued to be ineffective against huge volumes of petroleum based materials, and ultimately two more crews became disoriented on the upper floors and were unable to escape. When the evacuation order was given one hour and forty-five minutes into the event, five firefighters and one officer were missing. None survived.   

A subsequent exterior attack was set up and lasted for over 20 hours utilizing aerial pieces and deluge guns from Worcester and neighboring departments. Task force groups from across the State of Massachusetts responded to initial suppression and subsequent recovery efforts. During this time, the four upper floors collapsed onto the second which became known as “the deck”. Over 6 million gallons of water were used during the suppression efforts.   

According to NFPA records, this is the first loss of six firefighters in a structure fire where neither building collapse nor an explosion was a contributing factor to the fatalities.     

 

Fireground Operations

    

KEY ISSUES   

Abandoned building left unprotected and unsecured.   

  • The failure to properly secure and maintain security at this warehouse allowed vagrants to enter, live in, and cause a fire in the building.
  • The lack of detection and suppression systems allowed the fire to grow unrestrained until discovered from the outside.

No barriers to prevent the spread of fire and smoke in a large space.   

  • Despite some floors having over 15,000 square feet of storage space, there were no rated fire walls, functioning fire doors, or even an interior finish that would help limit fire growth and the spread of heat and smoke.

Fire spread via combustible interior finishes.   

  • Being a cold storage warehouse, many walls and ceilings were covered with a combustible insulation material including cork, tar, expanded polystyrene foam, and sprayed-on polyurethane foam.

Delayed fire reporting   

  • The building occupants left the warehouse without notifying authorities, and the fire was reported by passing motorists who observed smoke venting from the roof.
  • The absence of uncovered windows also prevented earlier detection from the exterior.

Access limitations for fire suppression and rescue.   

  • Building construction featured a single staircase from the basement to the roof. This vertical opening was the only way to move through all levels and was congested with men and equipment from the start of operations.
  • The storage areas of the warehouse had no windows. These two factors left firefighters above the first floor without a secondary escape route and prevented ladder and rescue operations through windows.

Unusually long interior travel distances.   

  • Firefighters had to crawl over 200 feet through heavy smoke from the single staircase to conduct a proper search.
  • Most lifelines were only 50 foot and SCBA air was limited to 30 minutes.
  • Searches and rescue operations were ineffective under these circumstances.

    

Exterior Circa 1998

BUILDING HISTORY AND CONSTRUCTION   

The Worcester Cold Storage and Warehouse building was a six story structure at 266 Franklin Street in the heart of Worcester’s former warehousing and cold storage district. In the first half of the 21st century, cold storage was vital to the preservation and delivery of food before refrigerators became commonplace in American kitchens. The location was ideal with rail service provided by the former Boston and Albany Railroad which had a siding against the south end of the warehouse.   

Even after the post-WWII decline in railroads, truck traffic was easily accommodated over nearby roads and later on the abutting Interstate 290 which was built in the late 1960’s.   

The original warehouse (called “A-building” in previous reports) was constructed in 1906, faced due north onto Franklin Street and bordered Arctic Street to the east. There were six storage levels as well as a basement. The building measured 88 feet by 88 feet and had over 7,000 square feet of floor space on each level. The warehouse had an approximate exterior height of 80 feet.   

An addition (called “B-building”) was constructed in 1912 against the west wall of A-building and measured 72 feet by 120 feet on the third floor and above. The 72 foot wall faced Franklin Street. The first and second floors were 88 foot and 101 foot deep respectively to accommodate railroad sidings and other structures on the southern on “C” side. Other investigations have referred to the former western exterior wall of A-building as “the fire wall” but there is no indication that this was a planned function. At least one opening was cut through this party wall on each level to access the new addition. B-building provided an additional 7,000 square feet of storage on the third floor and over 8,000 on floors four through six.   

The Worcester Cold Storage complex involved additional structures to the south, but these were physically separate buildings and were not involved in this incident. The known openings between the warehouse and the southern structures were for utilities and refrigerants. The only effect was to block aerial access from the south during the fire.   

  • Construction methods appear to be the same in both A and B buildings.
  • Exterior walls were 18 inches thick and consisted of brick and mortar. Interior floors on the first and second levels were poured concrete and were supported by cast iron columns.
  • The concrete was covered with carpet or asbestos tile where appropriate for use.
  • Upper floors were of heavy timber construction with 12 foot long 4 inch by 12 inch wood joists (16 inch o.c.) resting in pockets in the east and west brick exterior walls and attached to 16 inch by 16 inch wood girders on the inside.
  • The girders were on 12 foot centers and rested on 16 inch by 16 inch wood columns which were spaced 12 feet apart in both dimensions.
  • Flooring consisted of two layers of tongue and groove hardwood with some areas having an additional layer of 3/8 inch diamond plate.
  • Ceilings on individual floors varied from open joists in storage areas to be a suspended ceiling in the office area on the second floor.
  • Photographs taken prior to the fire suggest that some sections also had “glass board” as a finished surface. The exact make up of this material has not been determined.
  • No documentation was made of ceiling heights within the warehouse, but it appears they were approximately 11 foot throughout.
  • The roof was tar and gravel over a wood deck which covered a 4 foot tall cockloft above the sixth floor ceiling/roof assembly.
  • Roof penetrations included the stairway and elevator shaft on the east end of A-building and a skylight over the elevator shafts on B-building. An illuminated billboard sat on the roof of B-building and received power external to the warehouse structure.

NOTE: For the balance of this report the entire fire building will be referred to as the “warehouse” which consists of “A-building” on the east and “B-building” on the west. The A and B terminology was adopted early on in other investigations and should not be confused with fireground identifications of sides “A, B, C, & D”. In a large complex such as this, other terminology could have been created such as “Building 1”, “Building Z”, etc. (refer to the USFA Report for diagrams)   

BUILDING USE   

Worcester Cold Storage, a business, occupied the warehouse from 1906 until 1983 when it was sold to Chicago Dressed Beef. In 1987, CDB Realty Trust purchased the warehouse. CDB moved its operations to Millbrook Street in 1988 and shut down the refrigeration system in 1989 at which time the building was abandoned.   

During its use, various petroleum based insulation materials were incorporated into the building including rigid expanded polystyrene boards and blown on polyurethane foam. These were applied to improve the temperature performance of the buildings Additionally, condensation along the exterior walls lead to the decay of some floor joists. Steel beams or angle brackets were added against the brick walls to pick up the floor load in several places.   

  • Even to long term employees, the building was hard to navigate.
  • The upper four stories were almost identical, and some workers reported getting lost under the dim interior lighting conditions.
  • Condensation would cause ice to form around the ceiling fixtures, and this cone of ice would severely limit the amount of illumination.
  • There was no useful external light then or during the fire.

After it’s closing in 1989, the building was illegally entered on many occasions, resulting in vandalism, occupancy by homeless individuals, and a number of small “campfires.” At the time the fire occurred, there were no utility services in operation. Significant amounts of garbage and human wastes were scattered around the warehouse. The homeless woman involved in this incident said the interior smelled like a sewer.   

VERTICAL PENETRATIONS   

There were three stairways in the warehouse. Stairway 1 was in the northwest corner of B-building and went from the first floor (approximate street level) up to the second floor office area. Stairway 2 was located in the southern portion of B-building and went from the first floor to the third. It may have also accessed the basement. Stairway 3 was on the east side of A-building and ran from the basement to the roof. This was the only means of egress from the upper floors and was used heavily during the fire.   

Two elevators were adjacent to stairway 3, and two more were adjacent to Stairway 2. At the time of the fire, all had been disabled, and the cars were in the basement. It is unknown if individual access doors were open or closed. The elevator shaft in B-building had a reinforced glass canopy at the roof level.   

  • A 14 inch by 14 inch shaft penetrated the ceiling of the second floor office area and originally housed a 12 inch pipe for the ammonia recovery system.
  • This may have opened through all floors, and the presence of the pipe could not be confirmed.

HORIZONTAL PENETRATIONS   

There was one opening on each level through the party wall dividing A-building from B-building. There were numerous doors and windows on the first floor, and several were forced open by firefighters to gain access. All windows on this level were secured with plywood to prevent entry. Windows on the second floor of B-building were limited to the office area in the northwest section and were also covered with plywood. There was a window on each of the second, third, and fourth floors in stairway 3 on the east side of A-building. A window opened into the adjacent elevator shaft on each of these floors also. All were blocked with plywood.   

INTERIOR FINISH   

Because the warehouse was used for cold storage, the insides of exterior walls and the roof were heavily insulated. Barriers between office space and freezer space were also heavily insulated. The original material of choice was cork which was impregnated or secured with tar. The thickness has been described from 6 inches to 18 inches depending on the location. Evidence was also found of additional layers of expanded polystyrene sheets and blown on polyurethane. In many places the finished surface was “glass board”. A recovered piece of this glass board was ignited by Worcester Fire personnel after this incident. The sample sustained combustion and gave off stringy black smoke not unlike pure styrene.   

It was reported that all the interior partitions were made of corkboard, but it was probably a covering rather than a structural element. The office walls on the second floor were paneling installed over drywall. Many photographs of the cold storage areas taken before the fire show interior surfaces with a clean outer appearance consistent with the glass board. This would have provided a cleanable and wear resistant surface as opposed to bare cork or foam insulation.   

INTERIOR LAYOUT   

Since the fire did not extend to the basement or first floor, the layout of these spaces is less important. The first floor did, however, provide the access to the rest of the building for fire operations. All space above the first floor was used for cold storage or moving goods with the exception of the second floor office area on the northern half of B-building.   

  

    

 

  

Taking it to the Streets; “Redefining the Fire Ground” Rescheduled

No comments

Taking it to the Streets with Christopher Naum

Wednesday Night’s Program has been postponed due to Emergent Server issues at BlogTalkRadio.

The Program has been rescheduled for Thursday November 4th at 9:00pm EDT

Turn Out to FireFighter NetCast.com and Taking it to the Streets for; “Redefining the Fire Ground”

If you missed last month’s program on the Tactical Renaissance of Combat Fire Suppression Operations and the new Rules of Engagement, with Chief Gary Morris (ret) Phoenix (AZ) Fire Department and Dr. Burt Clark from the NFA, then you missed out a some great insights and discussion. This month Taking it to the Streets is looking to further the dialog and look at “Redefining the Fire Ground”. Many would argue that the fire ground doesn’t need to be “redefined”; that the way we do business in the Streets is just fine and that the American Fire Service knows how to get the job done, at any cost.

The recent release of the NIST Technical Study of the Sofa Super Store Fire – South Carolina, June 18, 2007 has presented compelling data and information that provides further discernments of how our buildings react under fire conditions and how our tactical assumptions and deployments continue to be willfully miscued.  Joining Chris will be Chief Douglas Cline, from the City of High Point FD, North Carolina, a highly regarded national instructor, author, advocate, tactician and incident command.

Don’t miss out on debating and dialoging the transitional fire ground. It is here and it’s here to stay; you just didn’t know that it was changing. But then again, was anyone paying attention?  Join the live broadcast on Thursday night November 4th at 9:00pm ET, or download the post production podcast from Firefighter NetCast.com.

  • For additional Taking it to the Streets programming, HERE
  • Firefighter NetCast.com HERE
  • Taking it to the Streets for; “Tactical Renaissance and the Rules of Engagement” Show Link, HERE

Taking it to the StreetsTM On Your Street, In Your City, Across the County, Around the WorldTM ©2010

Taking it to the Streets is hosted by Christopher Naum and is a Buildingsonfire.com Series and Fire Fighter NetCast.com Production.

Taking it to the Streets; “Redefining the Fire Ground”

No comments

Taking it to the Streets with Christopher Naum

For a Rockin’ Hot Time, Tune in this coming Wednesday night, November 3rd  to FireFighter NetCast.com and Taking it to the Streets for; “Redefining the Fire Ground”

If you missed last month’s program on the Tactical Renaissance of Combat Fire Suppression Operations and the new Rules of Engagement, with Chief Gary Morris (ret) Phoenix (AZ) Fire Department and Dr. Burt Clark from the NFA, then you missed out a some great insights and discussion. This month Taking it to the Streets is looking to further the dialog and look at “Redefining the Fire Ground”. Many would argue that the fire ground doesn’t need to be “redefined”; that the way we do business in the Streets is just fine and that the American Fire Service knows how to get the job done, at any cost.

The recent release of the NIST Technical Study of the Sofa Super Store Fire – South Carolina, June 18, 2007 has presented compelling data and information that provides further discernments of how our buildings react under fire conditions and how our tactical assumptions and deployments continue to be willfully miscued.  Joining Chris will be Chief Douglas Cline, from the City of High Point FD, North Carolina, a highly regarded national instructor, author, advocate, tactician and incident command.

Don’t miss out on debating and dialoging the transitional fire ground. It is here and it’s here to stay; you just didn’t know that it was changing. But then again, was anyone paying attention?  Join the live broadcast on Wednesday night November 3rd at 9:00pm ET, or download the post production podcast from Firefighter NetCast.com.

  • For additional Taking it to the Streets programming, HERE
  • Firefighter NetCast.com HERE
  • Taking it to the Streets for; “Tactical Renaissance and the Rules of Engagement” Show Link, HERE

Taking it to the StreetsTM On Your Street, In Your City, Across the County, Around the WorldTM ©2010

Taking it to the Streets is hosted by Christopher Naum and is a Buildingsonfire.com Series and Fire Fighter NetCast.com Production.

Tactical Renaissance and the Rules of Engagement

1 comment
Taking it to the Streets with Christopher Naum

For a Rockin’ Hot Time, Tune in this coming Wednesday night to FireFighter NetCast.com and Taking it to the Streets for; “Tactical Renaissance and the Rules of Engagement”.

Joining Christopher Naum will be Chief Gary Morris (ret) Phoenix (AZ) Fire Department, Deputy Chief John Sullivan, Worcester (MA) Fire Department, along with Dr. Burt Clark from the NFA. We will be discussing the emerging Tactical Renaissance of Combat Fire Suppression Operations and the new Rules of Engagement. Don’t miss out for what will certainly be an insightful look at what the fire ground is transitioning to in 2010 and beyond. Join the live broadcast on Wednesday night September 22nd at 9:00pm ET, or download the post production podcast from Firefighter NetCast.com.

In the weeks ahead we’ll be publishing a six month schedule of upcoming guests and topics along within integrating post production podcast resources, training aides and supplemental reference links to make both the live broadcast program and downloads value added.

Taking it to the Streets is hosted by Christopher Naum and is a Buildingsonfire.com Series and Fire Fighter NetCast.com Production.

  • Check out the IAFC Safety Health & Survival Section HERE and the newly published Rules of Engagement
  • For additional Taking it to the Streets programming, HERE
  • Firefighter NetCast.com HERE
  • Taking it to the Streets for; “Tactical Renaissance and the Rules of Engagement” Show Link, HERE

Taking it to the StreetsTM On Your Street, In Your City, Across the County, Around the WorldTM ©2010

The International Association of Fire Chiefs (IAFC) is committed to reducing firefighter fatalities and injuries. As part of that effort the Safety, Health and Survival Section has developed “Rules of Engagement of Structural Firefighting” to provide guidance to individual firefighters, and incident commanders, regarding risk and safety issues when operating on the fireground. These rules are available in a poster which can be downloaded or ordered from http://fireservicebooks.com