Fire/EMS Safety, Health and Survival Week 2011: Day Five: Near-Misses, Maydays and Floor Collapses

1 comment

Do you know what's underneath you as you're making entry?

During the last quarter of 2010 and leading well into the second quarter of 2011 there has been a significant emerging trend developing in basement fires, compromised floor systems and assemblies leading to collapse and numerous near-miss events, close calls and unfortunatly, line of duty deaths during fire operations.

If you’ve been paying attention to the various news and on the job reports these past number of months, you may have noticed the increasing numbers of emerging trend evident in near miss, close-calls resulting in maydays, RIT deployments and self-rescue resulting from floor compromise and floor collapse. The double line of duty deaths of two San Francisco (CA) Fire fighers while operating in a Terraced (Hillside construction) residential occupancy while operating below the base level diaphragm (upper street level access). (HERE)

In December 2010,  I was doing some research and posting links related to the first one or two events on Buildingsonfire on Facebook, HERE, it became evident at the time that there was an immediate opportunity to get some learning’s and insights out. If you have a chance head over to Facebook and link into Buildingsonfire and check out the incident links posted as well as some immediate report links. (Demember 2010 time frame)

In a coincidential posting on July 28, 2010, I posted on CommandSafety.com an interesting incident that I came across while preparing for a new post related to a near-miss event that occured in which a Camp Taylor (KY) firefighter survived a floor collapse that momentarily trapped him proximal to the seat of a working basement fire. Camp Taylor (FD) Captain Michael Long sustained second and third degree leg burns after falling through the floor of the burning home and subsequently being rescue by other fire department personnel after calling a mayday.

This event has all the ingrediants the the 2011 Safety Week focus on Surviving the Fire Ground and managing the Mayday. Little did I know that later, in February 2011, while participating in the National FireFighter Near-Miss Reporting System Stakeholders meeting in California, would I have the chance to hear Captain Long’s story first hand, and then also have the opportunity to have him as a guest, sharing his story live on the Taking it to the Streets Radio program in February. (HERE)

Camp Taylor (FD) Captain Michael Long’s near-miss and story of survival resonates with this year’s theme of  Surviving the Fire Ground- Firefighter, Fire Officer and Command Preparedness and Managing the Mayday and provides an opportunity to focus on the event in this, Day Five of the 2011 Fire/EMS Safety, Health and Surival Week activities. The details of Captain Long’s story can be found on the National FireFighter Near Miss Reporting System web site (HERE) as well as in the June 2011 issue of Fire Engineering Magazine titled, Floor Collapse: A Survivors Story. Let me state upfront also the Captain Michael Long will be presenting the accounts of his near miss event and the lessons-learned at IAFC Fire-Rescue International Conference in Atlanta in August (HERE).

 On July 25, 2010, Captain Michael Long of the Camp Taylor (Ky.) Fire Protection District fell through the floor of a house during a four-alarm fire and suffered severe burn injuries. On Aug. 30, 2010, Capt. Long submitted a near-miss report based on this event. The National Fire Fighter Near-Miss Reporting System is an anonymous and confidential reporting system; however, Capt. Long wanted to have his name associated with this report so that others would understand the value of sharing near-miss events. What follows is an excerpt from his report and excerpts from a recent phone interview. To read his full report, including an extensive lessons learned section, search by report number for report #10-1072 on the Search Reports page of www.firefighternearmiss.com.

  

Near Miss Report Event #2010-1072

  

 “I made sure my crew was ready to enter, sounded the floor for stability and then crossedover the threshold, entering the structure. When I was approximately 5 feet inside the structure, I felt the floor start to give way. I turned toward the front door to try to bail out, and at the same time yelled at others to get out, when the floor system collapsed. This was no ordinary collapse. More than two-thirds of the first floor collapsed simultaneously. The living room, dining room, kitchen, bathroom and foyer all fell at once. “When the collapse happened, I was the only one who fell into the basement, right into the heart of the fire. All I could see around me were flames.

I could not see the hole that I had fallen through. I could not see my fellow firefighters above me. All I could see was fire. I began to try to find something to use to climb back up with. Since I did not know what type of collapse had occurred, I just started clawing away at anything as I was trying to climb. During this time, my legs were burning.

Fire was burning up between my boots and my bunker pants. The pain was intense. My deputy chief was trying to put a line on me for protection, but the fire was extremely intense. He was lying on the porch with fire shooting out over his head. He stated he could occasionally see the top of my helmet and the reflective stripes on my coat sleeves.

By a bit of luck, a roof ladder was laying in the front yard that had just been taken off the roof after the completion of a ventilation operation.

My deputy chief directed the crew to put the ladder into the hole for my escape. “By this time, I was burned on my legs and struggling with exhaustion and the intense heat. I was screaming both from pain and due to fear. I could hear screaming coming from above, butwas unable to make out the majority of it. I finally heard the word “ladder” and then felt something across my back. Once they got the ladder into the basement, I had to get around to it. I still could not see anything but fire, so this was all by feel. As I started up the ladder, I got two rungs up, reached for the third rung, and lost my grip and fell back into the basement landing on my back. I was so exhausted that I started making my peace with God that this was where I was going to die.

For the full excerpt from Captain Long’s near miss report go to the NFF Near Miss Reporting Site and Resource Link, HERE

  

Captain Long

Incident Lessons Learned from Captain Long:

  • Train as if it is real. Train, train, train, and then train some more. Take advantage of every opportunity to train. The better we are trained, the less our chance of injury. The training must be physically and mentally. Crews must focus on more hands-on scenario-based training that allows for problem solving. If crews are taught that the outcome to every scenario is static, they are not being encouraged to think. Every run is different; no single solution applies to every situation. Adaptations or decisions that are not in step with changing conditions can actually be disadvantageous. We must make the right decisions based on the correct interpretation of the environment and blend those observations with our knowledge, skills, and abilities to map a course of action that will lead us to a successful outcome. Read reality and come up with the best possible plan. In my situation, quick thinking and adapting to the problem that presented itself saved my life.
  • Mutual-aid training is a must. We must train more with our neighboring departments to improve operations. It is occasionally difficult to work in situations where you do not really know with whom you will be working or where the command structure and tactics differ from those of your department. We all learn from the same book; however, the interpretations and tactics differ from person to person and department to department. I am not saying anyone is right or wrong in the way they do things—we all just need to do a better job of understanding that there is more than one way to get the job done.
    We cannot know exactly how everyone on an emergency scene will perform because each person has a different interpretation of his surroundings and role in the system. Standard operating guidelines (SOGs) can assist in this area, but SOGs rely on perceptions and interpretations by individuals to be implemented as intended. Accidents often happen because everyone has a unique perspective on the environment, and each makes different decisions based on their perception.
    We must perceive the environment correctly to ensure we make the right move. If these actions are not communicated and coordinated in the intricate system that is the fireground, accidents will be the inevitable and regrettable results. Training and frequent reviewing of SOGs are vital to our safety.
  • Risk assessment. Sounding the floor prior to entry is not always a good indicator of the floor’s stability. Less than two minutes before I made entry, there were three other firefighters, at least the same weight as I, in the same area where the collapse occurred. Everything changed in a very short time. There was no warning. Adkins told me at the hospital that all he heard was a “whoosh” sound when the floor collapsed. Then I disappeared. Within two minutes, the floor assembly went from being able to sustain a live load of at least 900 pounds in that area (accounting for gear, equipment, SCBA, and so on) to collapsing with about a 300-pound load, and I was close to a load-bearing wall. A good way to evaluate risk vs. gain is to get the most accurate report on burn time as possible to help determine structural integrity.
  • Rapid intervention. RIT is a critical fireground benchmark and is very important for safety, but it would have been ineffective in this situation. Had my crew not reacted the way they did immediately, I would not have been able to last long enough to wait for the RIT. In the time it would have taken for the RIT to gear up, come up with a plan, and enter, I would have died. The stars aligned in my favor that night. The person calling the Mayday or a nearby crew often mitigates personnel emergencies. My crew was able to act decisively at the correct time, and I am alive because of it. It is important to remember that a large percentage of Maydays are mitigated by the crew to which the lost firefighter is assigned or a nearby crew. RIT deployments account for a small number of rescues; we must always be alert and ready for the “incident within the incident.”
  • Manage your emotional response. From a personal standpoint, you must rely on your training and try not to panic. Know your equipment and procedures well. I did panic, but I was still able to keep myself together enough to know not to leave the area since I had been told that the stairs had burned away. Keeping my SCBA on, resisting the emotional reaction to remove my mask because of claustrophobia, was a huge factor in my survival. If I had tried to find another way out, my crew could not have gotten to me with the ladder. Had I removed my mask, the story would have ended quite differently. When I teach, I try to train as if it is the real thing. Never take a run for granted. Always expect the worst; you will be better prepared to deal with the unexpected.
    If we continually study accident reports and learn from them, the likelihood of being surprised will be diminished. Peter Leschak writes in Ghosts of the Fireground: ”In fire and other emergency operations, you must not only tolerate uncertainty; you must savor it, or you won’t last long. The most efficient preparation is a general mental, physical, and professional readiness nurtured over years of training and experience. You live to live. Preparing is itself an activity, and action is preparation.”
  • Talk about it. Critical incident stress debriefing (CISD) is important for ensuring that personnel from all departments on scene are taken care of emotionally. CISD needs to extend beyond just one or two briefings. Personnel involved in a highly emotional event must be given the opportunity to speak to a trained CISD team member early and be given as much time as is needed to work through their issue. Some firefighters have a macho attitude and try to deal with their emotions on their own, or maybe they don’t deal with them at all. Others self-medicate with alcohol or, worse, these difficult emotional events are allowed to fester with no relief. People should be accepting of those who deal with issues up front and tell their stories. Telling these stories makes us better and helps to keep us safe. This reduces the possibility of “snapping” because you have too much pent-up emotion.
    My fellow firefighters are still affected by this event, even those who were not there. Department personnel must be open-minded and receptive to the fact that emotional events will affect your performance and your personal life and that it is acceptable to be open and deal with them. When difficult emotional situations present themselves, members should attempt to deal with them as soon as possible.
  • Know what is possible and what is not. Know the experience level of your crew. Going into a bad situation with a crew that may not have exposure to a lot of different situations or that you aren’t that familiar with could make operations more difficult. I had everything from a 30-year veteran to a one-year recruit, so the experience level was all across the board. I knew that the situation we were going into was getting worse and required quick action, so I took the lead to ensure that the operation would be completed as quickly as possible. I knew my deputy chief would be watching us to ensure things were proceeding safely. I knew my crew could get the job done; however, this was an operation that is not often practiced and I wanted to make sure it was done correctly. I will not send my crew into an area that I am not comfortable going into. The more you train and the more people you can train with, the better you will understand your capabilities.

 Listen or download the special interview I had with Captain Mike Long as well as

Taking it to the Streets Radio Program and Interview with Capt. Long

 

Taking it to the StreetsTM is a monthly radio show featured on BlogTalk Radio and is hosted by nationally renowned fire service leader Christopher Naum, a  36-year fire service veteran and highly regarded national instructor, author, lecturer and fire officer and  the distinguished leading  national authority on building construction and fire ground operations.  Taking it to the StreetsTM is a Buildingsonfire.com Series and FireFighternetcast.com Production,   © 2011 All Rights Reserved 

Taking it to the Streets: Near Miss Reporting and One Captain’s Close Call

Podcast: Play in new window | Download

The progam was taped from the Live Broadcast on March 16th at 9pm EST

Taking it to the Streets: Near Miss Reporting and One Captain’s Close Call

On Your Street, In Your City, Across the Country, Around the WorldTM

The direct show link is here

The line-up of Program guests included, Lt. Steve Mormino, FDNY (ret), Captain CJ Haberkorn Denver (CO) Fire Department and Special Guest Captain Michael Long, Camp Taylor (KY) Fire Protection District.

Grab a cup of coffee and sit down for a special two part, two hour program with Taking it to the Streets on Firefighernetcast.com where we’ll be discussing the National Near-Miss Reporting System and the untapped resources that the program and system provides with Christopher Naum and this outstanding group of fire service leaders. The second part of the program will dedicated to the personal account of Captain Long’s Close Call event from July 25, 2010 (NMR #10-1072) when a catastrophic floor collapse at a residential occupancy plunged him into a fire involved basement.

Check out the latest downloads of recent programs in the archives by visiting Taking it to the Street’s webpage on Firefighternetcast.com or for program insights at CommandSafety.com.    

  • Firefighternetcast.com HERE
  • Taking it to the Streets Radio Programs, HERE and HERE 
  • Buildingsonfire.com, HERE  

Taking it to the StreetsTM, radio program hosted by highly regarded national instructor, author, lecturer and fire officer Christopher Naum, continues to provide provocative insights and dynamic discussions with leading national fire service leaders and guests on important issues affecting the American Fire Service with applications internationally within the tradition and brotherhood of the Fire Service.

Taking it to the StreetsTM, is a Buildingsonfire.com Series and Firefighter Netcast.com Production, in affiliation with the Command Institute

 

National Fire Fighter Near Miss Reporting System’s Support for the 2011 Safety Week

Don’t forget to go to the National Firefighter Near Miss Reporting System for  number of exceptional training aids, resources, PPT and more. NFFNMRS, HERE

Here are some of the National Firefighter Near Miss Reporting System Produced 2011 Safety Week Products

 
File Title File Size File Description
  • Presentation: Preventing The Mayday
  • 176 KB A powerpoint presentation about situational awareness, planning, size-up, and defensive operations
  • Presentation: Being Ready for the Mayday
  • 176 KB A powerpoint presentation about personal safety equipment, communications, and accountability systems
  • Presentation: Fire Fighter Expectations of Command
  • 176 KB A powerpoint presentation about fire fighter expectations of command.
  • Presentation: Self-Survival Skills
  • 176 KB A powerpoint presentation about self survival skills at a mayday.
  • Presentation: Self-Survival Procedures
  • 176 KB A powerpoint presentation about self survival procedures.
  • Grouped Report: Preventing The Mayday
  • 176 KB A grouped report about situational awareness, planning, size-up, and defensive operations
  • Grouped Report: Self Survival Procedures
  • 176 KB A grouped report about self survival procedures
  • Grouped Report: Being Ready for the Mayday
  • 176 KB A grouped report about personal safety equipment, communications, and accountability systems

    In the meantime here are some links I pulled together that you should take the time to read and share with your companies, personnel and staff…..

    This seems like a good time to have a ten minute drill on these events as Operating Experience (OE) on floor systems and operational safety, calling or commanding the mayday.

     Or take some time to visit the The IAFF Fire Ground Survival Program (FGS)site which has the most comprehensive survival-skills and mayday-prevention program currently available and is open to all members of the fire service. Incorporating federal regulations, proven incident-management best practices and survival techniques from leaders in the field, and real case studies from experienced fire fighters, FGS aims to educate all fire fighters to be prepared if the unfortunate happens.  (Day One: Are you ready, HERE)

    • For links to the IAFF Fire Ground Survival Program, HERE and HERE

    Self-Survival Procedures

    FGS Online Program Chapter 3
    To improve survivability in a Mayday situation, a fire fighter must know how to alert rescuers to his or her location and perform self-survival techniques. Through the study of fire fighter fatalities, NIOSH has identified specific actions fire fighters can take to help save themselves. Variations of this same NIOSH recommendation have appeared in numerous fire fighter fatality reports. These recommendations were used to create a self survival procedure that is easy to remember using a mnemonic (GRAB LIVES). Following these steps increases the likelihood of the rescuers finding and assisting the fire fighter to safety.
    When a fire captain died when trapped by partial roof collapse in a vacant house fire in Texas, NIOSH recommended in report number F2005-09 that trapped fire fighters should:

    • First, transmit a distress signal while they still have the capability and sufficient air.
    • Next, manually activate their PASS device. To conserve air while waiting to be rescued, try to stay calm and avoid unnecessary physical activity.
    • If not in immediate danger, remain in one place to help rescuers locate them.
    • Survey their surroundings to get their bearings and determine potential escape routes.
    • Stay in radio contact with the IC and other rescuers.
    • Attract attention by maximizing the sound of their PASS device (e.g., by pointing it in an open direction); pointing their flashlight toward the ceiling or moving it around; and using a tool to make tapping noises on the floor or wall. 

    Self-Survival Skills

    FGS Online Program Chapter 4

    Disentanglement Maneuvers

    Fires inside an enclosed structure create a mess for fire fighters operating on the floor. Fire fighters often encounter debris that has fallen off shelves, and ceiling and wall fixtures that have burned and are left hanging to the floor. These hazards, coupled with the mess a fire fighter creates when searching for victims in smoky environments, can create egress problems for a fire fighter.

    As fire burns draperies, blinds, lighting fixtures, computer wiring, and HVAC ducting, the possibility of encountering an entanglement hazard increases. The overhead ducting of the HVAC system contains wires that give the ducting its stability.

    If a fire breaches the ceiling and burns the ducting, the wires within the ducting fall to the floor. These wires can cause a dangerous entanglement hazard to fire fighters operating on the floor. Fire fighters must anticipate these hazards and have a plan to follow when egress is cut off.

    NIOSH Alert: Preventing Injuries and Deaths of Fire Fighters

    Fire Fighter Expectations of Command

    FGS Online Program Chapter 5
    A discussion of what command must communicate to the distressed fire fighter, dispatch, the RIT group supervisor and all others assigned to the incident to assure a successful rescue.

    Here are Some Mission Critical Reference Links for Operational Insights and Operating Experience (OE) to support Your Training and Operational Needs not only this week, but through the entire year.

     

    Here are some Safety Considerations related to Residential Occupancies (non-inclusive) for Operations at Basement Fires that will support fireground operational safety:

    • Conduct a thorough fire size-up and communicate the findings to all personnel on-scene before entering the building.
    • Conduct an assessment of the Building Profile ( building construction type, structural assembly systems and features and age) and assesss fire behavior and intensity levels.
    • Ensure an adequte Risk Assessement is conducted and that Risk versus Gain is determined
    • Maintain situational awareness throughout the tactical deployment of crews within the interior of the structure
    • Conduct a 360 degree perimeter assesement when feasible to determine access and egress points, fire location and travel and other mission critical operational perameters.
    • Incident commanders and company officers should be trained and experienced in structure fire size up to avoid putting fire fighters at unneeded risk of working above fire-damaged floors.
    • Do not enter a structure, room, or area when fire is suspected to be directly beneath the floor or area where fire fighters would be operating, or if the location of the fire is unknown.
    • Never assume structural safety of any floor (regardless of the construction) having a significant fire under it.
    • Conduct pre-incident planning inspections during the construction phase to identify the type of floor construction.
    • If pre-planning is not conducted, assume residential construction and small commercial buildings built since the early 1990s may contain engineered wood I-joists.
    • Report construction deficiencies noted during preplanning to local building code officials. For example, engineered wood floor joists should only be modified per manufacturer specifications—usually limited to cutting to length and removing pre–cut knockouts for utility access. Report damaged or cut chords or webs to building officials.
    • Develop, enforce, and follow standard operating procedures (SOPs) on how to size up and combat fires safely in buildings of all construction types. Rapid intervention teams (RIT) should include a portable ladder with their RIT equipment when deployed at basement fires.
    • Ensure Time Compression is considered: Ensure Command has the ability to monitor progress or elapsed incident time and adjusts strategic and tactical plans accordingly and in a time effective manner. 
    • Provide training on identifying signs of weakened floor systems (soft or spongy feel, heat transmitted through floor, downward bowing, etc.).
    • Make fire fighters aware that all floor types can fail with little or no warning.
    • Use a thermal imaging camera to help locate fires burning below or within floor systems, but recognize that the camera cannot be relied upon to assess the strength or safety of the floor. (Refer to the recent UL Test Data and Operational Safety Considerations ”Structural Stability of Engineered Lumber in Fire Conditions” available at http://www.uluniversity.us/ )
    • Fire fighters should be trained on the use of thermal imaging cameras, including limitations and difficulties in detecting fire burning below floor systems. (See reference to UL above)
    • Immediately evacuate and, if possible, use alternate exit routes when floor systems directly beneath the floor where fire fighters would be operating are weakened by fire.
    • Use defensive overhaul procedures after fire extinguishment in structures containing fire-damaged floor systems of all types.
    • Consider becoming active in the building code process and influence requirements for fire resistance of floor and ceiling systems to further fire fighter safety and health.
    • Ensure RIT personnel area staged and have complete a site assessment of the building and occupany upon thier arrival and set-up
    • Ensure that a rapid intervention team (RIT) is on the scene as part of the first alarm and in position to provide immediate assistance prior to crews entering a hazardous environment

    Here’s some screen shots from Buildingsonfire on Facebook. Go HERE or follow the link at the left column. Join the growing list of over 3900 fans with Buildingsonfire on Facebook and Buildingsonfire.com

    Fire/EMS Safety, Health and Survival Week: Day Three-The New Rules of Engagement

    5 comments

    Fire/EMS Safety, Health and Survival Week: Day Three-The New Rules of Engagement

     With so many changes (budget cuts, staffing reductions, reduced training, etc.) in so many fire departments, it is critical for fire fighters to focus on their own survival on the fire ground. There is no other call more challenging to fire ground operations than a Mayday call the unthinkable moment when a fire fighter’s personal safety is in imminent danger. Fire fighter fatality data compiled by the United States Fire Administration have shown that fire fighters becoming trapped and disoriented represent the largest portion of structural fire ground fatalities. The incidents in which fire fighters have lost their lives, or lived to tell about it, have a consistent theme inadequate situational awareness put them at risk.

    New Rules of Engagement

     Fire fighters don’t plan to be lost, disoriented, injured or trapped during a structure fire or emergency incident. But fires are unpredictable and volatile, and they will not always go according to plan. What a fire fighter knows about a fire before entering a blazing building may radically change within minutes once inside the structure. Smoke, low visibility, lack of oxygen, structural instability and an unpredictable fire ground can cause even the most seasoned fire fighter to be overwhelmed in an instant.

    It's Not a Matter of IF, It's a Matter of When

    It’s not a matter of IF the MAYDAY happens, it’s WHEN! Thius the reason for the 2011 Fire/EMS Safety, Health and Survival Week focus on Surviving the Fire Ground Fire Fighter, Fire Officer & Command Preparedness

    Theme: Surviving the Fire Ground Fire Fighter, Fire Officer & Command Preparedness

    • IAFC Safety Week Resources: Firefighter Survival, HERE
    • National Fire Fighter Near Miss Reporting System Resources, HERE

    With that being said, there must be a means and a method to better defined and more accurately

    • Without understanding the building-occupancy relationships and integrating; construction, occupancies, fire dynamics and fire behavior, risk, analysis, the art and science of firefighting, safety conscious work environment concepts and effective and well-informed incident command management, company level supervision and task level competencies…You are derelict and negligent and “not “everyone may be going home”.
    • Our current generation of buildings, construction and occupancies are not as predictable as past conventional construction; risk assessment, strategies and tactics must change to address these new rules of structural fire engagement.
    • There is a need to gain the building construction knowledge and insights and to change and adjust operating profiles in order to safe guard companies, personnel and team compositions. It’s all about understanding the building-occupancy relationships and the art and science of firefighting, Building Knowledge = Firefighter Safety (Bk=F2S)
    • Refer to: Fire/EMS Safety, Health and Survival Week: Day Two- Building Knowledge = Fire Fighter Safety 
    • When we look at various buildings and occupancies, past operational experiences; those that were successful, and those that were not, give us experiences that define and determine how we access, react and expect similar structures and occupancies to perform at a given alarm in the future.
    • Naturalistic (or recognition-primed) decision-making forms much of this basis. We predicate certain expectations that fire will travel in a defined (predictable) manner that fire will hold within a room and compartment for a predictable given duration of time; that the fire load and related fire flows required will be appropriate for an expected size and severity of fire encountered within a given building, occupancy, structural system; in addition to having an appropriately trained and skilled staff to perform the requisite evolutions.
    • Executing tactical plans based upon faulted or inaccurate strategic insights and indicators has proven to be a common apparent cause in numerous case studies, after action reports and LODD reports.
    • Our years of predictable fireground experience have ultimately embedded and clouded our ability to predict, assess, plan and implement incident action plans and ultimately deploy our companies-based upon the predictable performance expected of modern construction and especially those with engineered structural systems.
    • If you don’t fully understand how a building truly performs or reacts under fire conditions and the variables that can influence its stability and degradation, movement of fire and products of combustion and the resource requirements for fire suppression in terms of staffing, apparatus and required fire flows, then you will be functioning and operating in a reactionary manner, that is no longer acceptable within many of our modern building types, occupancies and structures.
    • This places higher risk to your personnel and lessens the likelihood for effective, efficient and safe operations.
    • You’re just not doing your job effectively and you’re at RISK. These risks can equate into insurmountable operational challenges and could lead to adverse incident outcomes. Someone could get hurt, someone could die, it’s that simple; it’s that obvious

     

    Original IAFC 2001 ROE

     

    • Combat Fire Suppression and Engagement has been dramatically influenced by numerous challenges in terms of effectiveness, methodologies, risk and operational capabilities….yet we implement strategic and tactical models and protocol predicated on past performance of building structures and occupancies and fire fighting successes….
    •  It’s no longer just brute force and sheer physical determination that define structural fire suppression operations
    • We used to discern with a measured degree of predictability, how buildings would perform, react and fail under most fire conditions. Implementing fundamentals of firefighting and engine company operations built upon eight decades of time tested and experience proven strategies and tactics continues to be the model of suppression operations.
    • These same fundamental strategies continue to drive methodologies and curriculums in our current training programs and academies of instructions.
    • 2009 was a significant and decisive year for the fire service in a number of ways….
    • Controversy, debate, argument; enlightenment, knowledge, insights, awareness, comprehension, understanding….
    • Which leads me to call this the emerging tactical renaissance….

     

    The International Association of Fire Chiefs (IAFC) is committed to reducing firefighter fatalities and injuries. As part of that effort the nearly 1,000 member Safety, Health and Survival Section of the IAFC has developed the NEW  “Rules of Engagement of Structural Firefighting” to provide guidance to individual firefighters, and incident commanders, regarding risk and safety issues when operating on the fireground.

    The intent was to provide a set of “model procedures” for Rules of Engagement for Structural Firefighting to be made available by the IAFC to fire departments as a guide for their own standard operating procedure development.

    In August, 2008, following a year of discussion, the Section moved to develop a set of “Rules of Engagement for Structure Firefighting”.

    A project team was created consisting of Section members and representatives of other several other interested fire service organizations.

    These included the;

    • Fire Department Safety Officer Association (FDSOA),
    • the National Fallen Firefighter Foundation (NFFF),
    • the National Volunteer Fire Council (NVFC), the
    • National Institute of Occupational Safety and Health (NIOSH) and other organizations.
    • All draft material has also been shared with representatives of the International Association of Fire Fighters (IAFF) who developed a joint IAFF/IAFC Fire Ground Survival Project”.

     Three Section members also participated in the IAFF project.

    The direction provided the project team by the Section leadership was to develop rules of engagement with the following conceptual points;

    • Rules should be a short, specific set of bullets
    • Rules should be easily taught and remembered
    • Rules should define critical risk issues
    • Rules should define “go” or “nogo” situations
    • A companion lesson plan/explanation section should be provided

    Early in development the Rules of Engagement, it was recognized that two separate rules were needed –one set for the firefighter, and another set for the incident commander.

    Thus, the two sets of Rules of Engagement were conceived and developed.

    Each set has several commonly shared bullets and objectives, but the explanations are described somewhat differently based on the level of responsibility (firefighter vs. incident commander).

    The 2010 Rules of Engagement reflects nearly two years of public comment and feedback from several presentations at fire service conferences, including the National Fallen Fire Fighters Safety Summit held at the National Fire Academy this past March 2010.

    The “Rules” was formally adopted by the IAFC Health, Safety and Survival Section at the Fire Rescue International Conference that was held in Chicago this past August 2010

    The project team was lead by Chief Gary Morris,

    Document Description

    Section One

    • includes introduction statements and background regarding the Rules of Engagement project.

    Section Two

    • acknowledges the Project team members and others that assisted in the project.

     Section Three

    • contains the individual “Bullets” for both the Rules of Engagement for Firefighter Survival as well as the Incident Commanders Rules of Engagement for Firefighter Safety.

     Section Four

    • describes the objectives attached to each of the individual “bullets” for both set of Rules.

     Section Five

    • provides an introduction and overview of the lesson plans for the Rules of Engagement.

     Section Six

    • includes the lesson plan for the Rules of Engagement of Firefighter Survival.

     Section Seven

    • contains the lesson plans for the Incident Commanders Rules of Engagement for Firefighter Safety.

     Section Eight

    • serves as appendixes and contains full investigation reports of several significant firefighter fatality incidents.

     The Need for Rules of Engagement

    • Firefighter safety must always be a priority for every fire chief and every member. Over the past three decades, the fire service has applied new technology, better protective clothing and equipment, implemented modern standard operating procedures, and improved training.
    • According to National Fire Protection Association (NFPA) data during this same period the fire service has experienced a 58 percent reduction in firefighter line of duty deaths. But, the country has also seen a paralleling 54 percent drop in the number of structural fires over the same period – thus, reducing firefighter exposure to risk.
    • With a continued annual average of more than 100 firefighter fatalities, the question remains; have we really made a difference with all these technology improvements? Or, is there more that we can do to improve the safety culture of the American fire service?
    • The U.S. Firefighter Disorientation Study, conducted by Captain Willie Mora, San Antonio, Texas, Fire Department, conducted a review of 444 firefighter fireground deaths occurring over a recent 16 year period (1990-2006).
      • The project broke out traumatic firefighter fatalities occurring in “open structures” and “enclosed structures”. Open structures was defined as smaller structures with an adequate number of windows and doors (within a short distance) to allow for prompt ventilation and emergency evacuation.
      • Enclosed structures were defined as large buildings with inadequate windows or doors to allow prompt ventilation and emergency evacuation. Research determined that 23 percent occurred when a fast and aggressive interior attack was made on an “opened structure”. When fast, aggressive interior attacks occurred in “enclosed structures” the fatality rate rose to 77 percent. Many occurred in “marginal” or rapidly changing conditions in which the firefighter should not have been in the building.
    • The fireground creates a significant risk to firefighters and it is the responsibility of the incident commander and command organization officers to minimize firefighter exposure to unsafe conditions and stop unsafe practices.
    • The fire service has always been a para-military organization when it comes to fireground operations. In most cases, the Incident Commander makes a decision, sends the order down to through supervisors to the company officer and crew.
    • Fire crews generally view these orders as top down direction. There is often little two‐way discussion about options.
    • Where this culture exists, crews have been trained to accept the order and do it – generally without question.
    • While these orders may be viewed as valid when issued they may involve inadequate risk assessment.
    • There has been little national development of basic “rules” that the incident command should use in defining risk assessment process and what is too high risk that may result in a “no-go” decision.
    • Furthermore, for the individual firefighter who is exposed to the greatest risk, we have not defined “rules” for them to follow in assessing their individual risk and when and how to say “no” to unsafe conditions or practices. The “Rules of Engagement” changes that.
    • The “Rules of Engagement” have been developed to assist both the incident command (as well as command team officers) in risk assessment and “Go” – “No-Go” decisions. Applying the rules will make the fireground safer for all and reduce injuries and fatalities.

     

    The development of the rules integrated several nationally recognized programs and principles. They included risk assessment principles from NFPA Standards 1500 and 1561.

    Also included where concepts and principles from Crew Resource Management (available from iafc.org) and data and lessons from the National Near-Miss Reporting System (firefighternearmiss.com).

    The development process also included review of lessons learned from numerous firefighter fatality investigations conducted by the National Institute of Occupational Safety and Health (NIOSH) Fire Fighter Fatality Investigation and Prevention Program.

    It’s incumbent that the fire chief and the Departments management team insure the safety of all firefighters working at structural fires.

    • All command organization officers are responsible for their own safety and the safety of all personnel working with them.
    • All officers and members are responsible are responsible for continually identifying and reporting unsafe conditions or practices.
    • The Rules of Engagement allows both the firefighter and the incident commander to apply and process these principles.
    • One principle applied in the Rules of Engagement is firefighters and the company officers are the members at most risk for injury or death.
    • The Rules integrate the firefighter into the risk assessment decision making process.
    • These members should be the ultimate decision maker as to whether it’s safe to proceed with assigned objectives.
    • The “Rules” allow a process for that decision to be made while still maintain command unity and discipline.

     

    Operational Excellence and the ROE

     

    The NEW Rules of Engagement

    It is well known that firefighting is hazardous with varying levels of risk to the firefighter.

    However, firefighting is not a military campaign where lives are lost to establish a beach head.

    No firefighter’s life is a building that eventually will be rebuilt. Keep all members safe so “Everyone Goes Home”!

    Rules of Engagement for Firefighter Survival

    • Size-Up Your Tactical Area of Operation.
    • Determine the Occupant Survival Profile.
    • DO NOT Risk Your Life for Lives or Property That Can Not Be Saved.
    • Extend LIMITED Risk to Protect SAVABLE Property.
    • Extend Vigilant and Measured Risk to Protect and Rescue SAVABLE Lives.
    • Go in Together, Stay Together, Come Out Together
    • Maintain Continuous Awareness of Your Air Supply, Situation, Location and Fire Conditions.
    • Constantly Monitor Fireground Communications for Critical Radio Reports.
    • You Are Required to Report Unsafe Practices or Conditions That Can Harm You. Stop, Evaluate and Decide.
    • You Are Required to Abandon Your Position and Retreat Before Deteriorating Conditions Can Harm You.
    • Declare a May Day As Soon As You THINK You Are in Danger. 

    The Incident Commanders Rules of Engagement for Firefighter Safety

    • Rapidly Conduct, or Obtain, a 360 Degree Size‐Up of the Incident.
    • Determine the Occupant Survival Profile.
    • Conduct an Initial Risk Assessment and Implement a SAFE ACTION PLAN.
    • If You Do Not Have The Resources to Safely Support and Protect Firefighters – Seriously Consider a Defensive Strategy.
    • DO NOT Risk Firefighter Lives for Lives or Property That Can Not Be Saved – Seriously Consider a Defensive Strategy.
    • Extend LIMITED Risk to Protect SAVABLE Property.
    • Extend Vigilant and Measured Risk to Protect and Rescue SAVABLE Lives.
    • Act Upon Reported Unsafe Practices and Conditions That Can Harm Firefighters. Stop, Evaluate and Decide.
    • Maintain Frequent Two‐Way Communications and Keep Interior Crews Informed of Changing Conditions.
    • Obtain Frequent Progress Reports and Revise the Action Plan.
    • Ensure Accurate Accountability of All Firefighter Location and Status.
    • If, After Completing the Primary Search, Little or No Progress Towards Fire Control Has Been Achieved -Seriously Consider a Defensive Strategy.
    • Always Have a Rapid Intervention Team in Place at All Working Fires
    • Always Have Firefighter Rehab Services in Place at All Working Fires

      

     
     
     

    ROE Fire Fighter

     

      

      

    ROE Command

     

    Other ROE Insights

    Size-Up Your Tactical Area of Operation.

    Objective:    To cause the company officer and firefighters to pause for a moment and look over their area of operation and evaluate their individual risk exposure and determine a safe approach to completing their assigned tactical objectives.

    Rapidly Conduct, or Obtain, a 360 Degree Situational Size Up of the Incident

    Objective:    To cause the incident commander to obtain an early 360 degree survey and risk assessment of the fireground in order to determine the safest approach to tactical operations as part the risk assessment and action plan development and before firefighters are placed at substantial risk.

    ______________________________________________________________________________

    Determine the Occupant Survival Profile.

    Objective: To cause the company officer and firefighter to consider fire conditions in relation to possible occupant survival of a rescue event as part of their initial and ongoing individual risk assessment and action plan development.

      

    Determine the Occupant Survival Profile.

    Objective: To cause the incident commander to consider fire conditions in relation to possible occupant survival of a rescue event before committing firefighters to high risk search and rescue operations as part of the initial and ongoing risk assessment and action plan development.

      

    Go in Together, Stay Together, Come Out Together

    Objective: To ensure that firefighters always enter a burning building as a team of two or more members and no firefighter is allowed to be alone at any time while entering, operating in or exiting a building. 

      

    Maintain Continuous Awareness of Your Air Supply, Situation, Location and Fire Conditions

    Objective: To cause all firefighters and company officers to maintain constant situational awareness their SCBA air supply and where they are in the building and all that is happening in their area of operations and elsewhere on the fireground that may affect their risk and safety.

    ______________________________________________________________________________

    You Are Required to Report Unsafe Practices or Conditions That Can Harm You. Stop, Evaluate, and Decide.

    Objective: To prevent company officers and firefighters from engaging in unsafe practices or exposure to unsafe conditions that can harm them and allowing any member to raise an alert about a safety concern without penalty and mandating the supervisor address the question to ensure safe operations.

      

    Act Upon Reported Unsafe Practices and Conditions That Can Harm Them. Stop, Evaluate and Decide.

    Objective: To prevent firefighters and supervisors from engaging in unsafe practices or exposure to unsafe conditions that will harm them and allowing any member to raise an alert about a safety concern without penalty and mandating the incident commander and command organization officers promptly address the question to insure safe operations. 

    ______________________________________________________________________________  

    Declare a May-Day As Soon As You THINK You Are in Danger

    Objective: To ensure the firefighter is comfortable with, and there is no delay in, declaring a May Day when a firefighter is faced with a life threatening situation and the May Day is declared as soon as they THINK they are in trouble.

      

    Always Have a Rapid Intervention Team in Place at All Working Fires.

    Objective: To cause the incident commander to have a rapid intervention team in place ready to rescue firefighters at all working fires.

    ______________________________________________________________________________

    Ensure Accurate Accountability of Every Firefighter Location and Status

    Objective: To cause the incident commander, and command organization officers, to maintain a constant and accurate accountability of the location and status of all firefighters within a small geographic area of accuracy within the hazard zone and aware of who is presently in or out of the building.

    If You Do Not Have the Resources to Safely Support and Protect Firefighters, Seriously Consider a Defensive Strategy

    Objective: To prevent the commitment of firefighters to high risk tactical objectives that cannot be accomplished safely due to inadequate resources on the scene.

    SOPs/SOGs

    Rules of Engagement for Structural Firefighting (pdf)

    Risk Management

    General Order: Two-In, Two-Out Compliance, Rapid Intervention Team, and Firefighter Survival

    Emergency Evacuation
    This policy identifies a standard system for the emergency evacuation of personnel at an emergency incident or training exercise.

    Fire and Rescue Departments of Northern Virginia – Rapid Intervention Team Command and Operational Procedures
    A collaborative RIT manual developed by fire and rescue departments in Northern Virginia. Promotes interoperability between multiple fire agencies.

    Lost or Trapped Firefighters
    This policy identifies the required actions for the search and rescue of lost or trapped firefighter(s).

    Model Procedures for Responding to a Package with Suspicion of a Biological Threat
    Local and world events have placed the nation s emergency service at the forefront of homeland defense. The service must be aware that terrorists, both foreign and domestic, are continually testing the homeland defense system.

    Safety Initial Rapid Intervention Crew (IRIC)
    This policy establishes procedures for ensuring the highest level of safety when conducting interior operations in an atmosphere that is Immediately Dangerous to Life and Health (IDLH).

    Safety Rapid Intervention Team (RIT)
    This policy establishes the department s criteria and procedures for Rapid Intervention Teams.

      

    Operational Excellence in 2011 and Beyond

      

    Taking It To The Streets: My Closing Commentary and The Rules of Combat Fire Suppression  

    The essence of fire service suppression operations is predicated upon the deployment and application of water as an extinguishing agent, in sufficient quantities, location and duration to extinguish a fire within an enclosed structural compartment. The universal engine company correlation of: “putting the wet stuff on the red stuff” is fundamental to structural fire suppression operations but is ambiguous at best in the context of today’s modern building construction, occupancies, structural systems and building features. 

    We used to discern with a measured degree of predictability, how buildings would perform, react and fail under most fire conditions. Implementing fundamentals of firefighting and engine company operations built upon eight decades of time tested and experience proven strategies and tactics continues to be the model of suppression operations. These same fundamental strategies continue to drive methodologies and curriculums in our current training programs and academies of instructions.

    The lack of appreciation and the understanding of correlating principles involving fire behavior, fuel and rate of heat release and the growth stages of compartment fires within a structural occupancy are the defining paths from which the fire service must reexamine engine company operations in order to identify with the predictability of occupancy performance during fire suppression operations thus increasing suppression effectiveness and firefighter safety.

    Our buildings have changed; the structural systems of support, the degree of compartmentation, the characteristics of materials and the magnitude of fire loading. The structural anatomy, predictability of building performance under fire conditions, structural integrity and the extreme fire behavior; accelerated growth rate and intensively levels typically encountered in buildings of modern construction during initial and sustained fire suppression have given new meaning to the term combat fire engagement.

    The rules for combat structural fire suppression have changed, but we have yet to write the rule book from which the new games plans must be derived…..

    However, we now have a new set of Rules for Engagement….

    • The Incident Commanders Rules of Engagement for Firefighter Safety
    • Rules of Engagement for Firefighter Survival
    • Tactical Renaissance ……….Tactical Patience

    …….integrate cutting edge research and emerging concepts on Tactical Patience, Tactical Entertainment, Command Compression, Structural Anatomy of Buildings, Five Star Command Model, Predicative Strategic Process, refined Tactical Deployment Models integrating intelligent Structural Anatomy and Predictive Occupancy Profiling and Integrating the RULES OF ENGAGEMENT for Structural Firefighting much more.  

    It’s really all about Fighting Fire with More Knowledge and smartly

      

     

    Taking it to the Streets with Christopher Naum

       

    Taking it to the StreetsTM, radio program hosted by highly regarded national instructor, author, lecturer and fire officer Christopher Naum, continues to provide provocative insights and dynamic discussions with leading national fire service leaders and guests on important issues affecting the American Fire Service with applications internationally within the tradition and brotherhood of the Fire Service.

     

    Taking it to the Streets “Tactical Renaissance and the Rules of Engagement”

    Podcast: Play in new window | Download

    Share

    This is the netcast which was offered live on September 22, 2010. Taking it to the Streets “Tactical Renaissance and the Rules of Engagement” Chief Gary Morris (ret) Phoenix (AZ) Fire Department, and Dr. Burt Clark from the NFA join Chris Naum as they discuss the emerging Tactical Renaissance of Combat Fire Suppression Operations [...]

    Taking it to the StreetsTM is a monthly radio show featured on BlogTalk Radio and is hosted by nationally renowned fire service leader Christopher Naum, a  36-year fire service veteran and highly regarded national instructor, author, lecturer and fire officer and  the distinguished leading  national authority on building construction and fire ground operations.  Taking it to the StreetsTM is a Buildingsonfire.com Series and FireFighternetcast.com Production,   © 2011 All Rights Reserved 

    Check out the latest downloads of recent programs in the archives by visiting Taking it to the Street’s webpage on Firefighternetcast.com or for program insights at CommandSafety.com.    

    • Firefighternetcast.com HERE
    • Taking it to the Streets Radio Programs, HERE and HERE 
    • Buildingsonfire.com, HERE

      

    A Buildingsonfire.com Series and Firefighter Netcast.com Production

    Taking it to the StreetsTM  with Christopher Naum
     
     

    Listen to all of the Taking It To The Streets shows here

     On the Air Monthly on Firefighter Netcast.com

    Advancing Firefighter Safety and Operational Integrity for the Fire Service through provocative insights and dynamic discussions dedicated to the Art and Science of Firefighting and the Traditions of the Fire Service.

     

    International Society of Fire Service Instructors; “Modern Construction Considerations for Company Officers.”

    1 comment

    The International Society of Fire Service Instructors is proud to announce the release of “Modern Construction Considerations for Company Officers.” The program is a train-the trainer package that combines the latest research on light weight building construction from National Institute of Standards & Technology (NIST), Underwriters Laboratories(UL), Michigan State University, The International Association of Fire Chiefs (IAFC), and the Chicago Fire Department into a single resource tailored for company-level instruction.

    The program was made possible through a Prevention & Research Grant from the Assistance to Firefighters Grant Program and the Department of Homeland Security. The ISFSI partnered with Eastern Kentucky University’s Fire & Safety Engineering Technology Program to analyze line of duty deaths between 1997 and 2009 to study the impact that lightweight construction has had on firefighters and firefighting operations.

    The DVD included in the program package contains all of the instructional resources necessary to provide quality training on this important topic. A wide variety of support materials are included to provide the user a deep understanding of the challenges with modern building construction techniques. Instructors can tailor the program to meet the needs of their audience, including a 2-hour brief up to a week-long program.

    The program will be distributed to all members of the ISFSI as a free member benefit. The ISFSI has also partnered with the Safety & Health Section of the IAFC to provide a copy to each of its members. ISFSI President, Eddie Buchanan, was on hand at the Safety & Health Section Meeting at FRI to personally deliver Chief Billy Goldfeder his copy as chair of the section. All members should expect their copy to arrive in their mailboxes over the next week.

    “I would like to extend a heartfelt thank you to the ISFSI members and staff who worked so hard to bring this product to firefighters across America and the globe. It is truly a lifesaving program and a fantastic use of grant funds. It is critical that this package get into the hands of every instructor and fire officer to ensure they are educated and prepared to handle the real risk that looms out there on the next call,” said President Buchanan.

    Check out the International Society of Fire Service Instructor’s (ISFSI) web site HERE.

    Not a member? Take the time to sign up and get connected.

    Rules of Engagement 2010

    5 comments

    IAFC Rules of Engagement

    Rules of Engagement Project; Increasing Firefighter Survival

    Developed by the Safety, Health and Survival Section International Association of Fire Chiefs

    The International Association of Fire Chiefs (IAFC) is committed to reducing firefighter fatalities and injuries.  As part of that effort the nearly 1,000 member Safety, Health and Survival Section of the IAFC has developed the recently approved  “Rules of Engagement of Structural Firefighting” to provide guidance to individual firefighters, and incident commanders, regarding risk and safety issues when operating on the fireground. The intent is to provide a set of “model procedures” for Rules of Engagement for Structural Firefighting to be made available by the IAFC to fire departments as a guide for their own standard operating procedure development.

    In August, 2008, following a year of discussion, the Section moved to develop a set of “Rules of Engagement for Structure Firefighting”. A project team was created consisting of Section members and representatives of other several other interested fire service organizations. These included the Fire Department Safety Officer Association (FDSOA), the National Fallen Firefighter Foundation (NFFF), and the National Volunteer Fire Council (NVFC), the National Institute of Occupational Safety and Health (NIOSH) and other organizations. All draft material has also been shared with representatives of the International Association of Fire Fighters (IAFF) who developed a joint IAFF/IAFC “Fire Ground Survival Project”. Three Section members also participated in the IAFF project. The direction provided the project team by the Section leadership was to develop rules of engagement with the following conceptual points;

    • Rules should be a short, specific set of bullets
    • Rules should be easily taught and remembered
    • Rules should define critical risk issues
    • Rules should define “go” or “no‐go” situations
    • A companion lesson plan/explanation section should be provided

    Early in development the Rules of Engagement, it was recognized that two separate rules were needed one set for the firefighter, and another set for the incident commander. Thus, the two sets of Rules of Engagement described in the attached document. The ROE were also inserted in the August issue of FireRescue magazine. Each set has several commonly shared bullets and objectives, but the explanations are described somewhat differently based on the level of responsibility (firefighter vs. incident commander).

    The attached and linked PDF document reflects nearly two years of public comment and feedback from several presentations at fire service conferences, including the National Fallen Fire Fighters Safety Summit held at the National Fire Academy this past March. The “Rules” were formally adopted by the IAFC Health, Safety and Survival Section at the Fire Rescue International Conference held last week in Chicago.

    The development of the rules integrated several nationally recognized programs and principles. They included risk assessment principles from NFPA Standards 1500 and 1561. Also included where concepts and principles from Crew Resource Management (available from iafc.org) and data and lessons from the National Near‐Miss Reporting System (firefighternearmiss.com). The development process also included review of lessons learned from numerous firefighter fatality investigations conducted by the National Institute of Occupational Safety and Health (NIOSH) Fire Fighter Fatality Investigation and Prevention Program.

    It’s incumbent that the fire chief and the Departments management team insure the safety of all firefighters working at structural fires. All command organization officers are responsible for their own safety and the safety of all personnel working with them. All officers and members are responsible are responsible for continually identifying and reporting unsafe conditions or practices. The Rules of Engagement allows both the firefighter and the incident commander to apply and process these principles.

    One principle applied in the Rules of Engagement is firefighters and the company officers are the members at most risk for injury or death. The Rules integrate the firefighter into the risk assessment decision making process. These members should be the ultimate decision maker as to whether it’s safe to proceed with assigned objectives. The “Rules” allow a process for that decision to be made while still maintain command unity and discipline. It is well known that firefighting is hazardous with varying levels of risk to the firefighter. However, firefighting is not a military campaign where lives are lost to establish a beach head. No firefighter’s life is a building that eventually will be rebuilt. Keep all members safe so “Everyone Goes Home”!

    Rules of Engagement for Firefighter Survival

    • Size‐Up Your Tactical Area of Operation.
    • Determine the Occupant Survival Profile.
    • DO NOT Risk Your Life for Lives or Property That Can Not Be Saved.
    • Extend LIMITED Risk to Protect SAVABLE Property.
    • Extend Vigilant and Measured Risk to Protect and Rescue SAVABLE Lives.
    • Go in Together, Stay Together, Come Out Together
    • Maintain Continuous Awareness of Your Air Supply, Situation, Location and Fire Conditions.
    • Constantly Monitor Fireground Communications for Critical Radio Reports.
    • You Are Required to Report Unsafe Practices or Conditions That Can Harm You. Stop, Evaluate and Decide.
    • You Are Required to Abandon Your Position and Retreat Before Deteriorating Conditions Can Harm You.
    • Declare a May Day As Soon As You THINK You Are in Danger.

    The Incident Commanders Rules of Engagement for Firefighter Safety

    • Rapidly Conduct, or Obtain, a 360 Degree Size‐Up of the Incident.
    • Determine the Occupant Survival Profile.
    • Conduct an Initial Risk Assessment and Implement a SAFE ACTION PLAN.
    • If You Do Not Have The Resources to Safely Support and Protect Firefighters – Seriously Consider a Defensive Strategy.
    • DO NOT Risk Firefighter Lives for Lives or Property That Can Not Be Saved – Seriously Consider a Defensive Strategy.
    • Extend LIMITED Risk to Protect SAVABLE Property.
    • Extend Vigilant and Measured Risk to Protect and Rescue SAVABLE Lives.
    • Act Upon Reported Unsafe Practices and Conditions That Can Harm Firefighters. Stop, Evaluate and Decide.
    • Maintain Frequent Two‐Way Communications and Keep Interior Crews Informed of Changing Conditions.
    • Obtain Frequent Progress Reports and Revise the Action Plan.
    • Ensure Accurate Accountability of All Firefighter Location and Status.
    • If, After Completing the Primary Search, Little or No Progress Towards Fire Control Has Been Achieved ‐ Seriously Consider a Defensive Strategy.
    • Always Have a Rapid Intervention Team in Place at All Working Fires
    • Always Have Firefighter Rehab Services in Place at All Working Fires

    Rules of Engagement Poster, PDF File ROE 2010

    Link to the IAFC Section Page and ROE Concept Paper