Skip to content


Still and Box for CFD: Near Miss Stairwell Collapse in Chicago

No comments

A fire in a three story multiple family apartment building injured four City of Chicago (IL) firefighters when an interior stairway collapsed during firefighting operations.

The building was constructed in 1927 and consisted of 5456 square feet of space with 3-5 apartment units. Built of masonry wall construction with a wood floor joist system, the fire was reported at 8:43 a.m., in the Type III classified occupancy.

Street View Pre-Fire

The fire began as a basement fire that travelled up two floors, eventually compromising an upper stairway which resulted in compromise and collapsed injuring four Chicago firefighters.

The inherent characteristics of the building and the manner of fire travel and impingement are apparent contributors to the event.

 

Aerial- Alpha; Goggle Maps

CFD Fireground Operations: Photo Tim Olk

 

The four firefighters sustained injures during operations when the internal stairwell connecting the second and third floors gave way.

The mayday was transmitted, and a  211 Plan 1 at approximately 09:00 hrs., seventeen minutes into the operation according to published reports issued by Deputy District Chief Lynda Turner.  Following the mayday and firefighter removals, defensive operations were initiated.

Two of the firefighters sustained smoke inhalation and two firefighters minor injuries, according to Fire Department officials.

Colerain and Eleven Minutes to Mayday: Lessons from 2008 Resonate Today

No comments

Remembering the Sacrafice: Capt. Broxterman and FF Schira

On Friday, April 4, 2008 at 06:13:02 hours, what began as a routine response for Colerain Township Fire and EMS Engine 102 to investigate a fire alarm activation at 5708 Squirrels nest Lane, Colerain Township, Ohio resulted in the deaths of Colerain Township Captain Robin Broxterman and Firefighter Brian Schira.

Upon their arrival at the scene of the two-story wood framed, residential building working fire conditions existed in the basement. The initial attack team consisted of Broxterman, Schira, and one other firefighter. The team advanced a 1¾-inch attack hose line through the interior of the building for fire control.

Even though, they were provided with some of the most technologically advanced protective clothing for structural firefighting and self-contained breathing apparatus, it appeared that Broxterman and Schira were overwhelmed by severe fire conditions in the basement. 

During their attempt to evacuate the building, the main-level family room flooring system in which the two were traveling on collapsed into the basement trapping the firefighters. Eleven minutes elapsed from time of arrival to the catastrophic chain of events.

This is one of those distinctive reports that has influential and critical operational, training and preparedness elements embedded throughout the report. 

It’s apparent there continues to be common threads shared by this event from 2008 and other events and incidents in the past five years where a single of multiple firefighters have lost their lives due to similarities in the apparent and common cause deficiencies and short comings identified.

All company and command officers should read and comprehend the lessons learned. Then, take these new found insights and see what the gaps are at the personal level (yours or those you supervise) as well as the shift, group, station, battalion, division or department as a whole.

If there are gaps, then identify a way to implement timely changes as necessary so there are No History Repeating (HRE) events.

The importance of Reading the Building, taking the time to complete the three sixty and being combat ready and “expecting fire”.

Remember their sacrifice, so we can learn.

 

  • Past Post on CommandSafety.com with Report Narrative and Incident Details HERE

 

The following factors were believed to have directly contributed to the deaths of Captain Broxterman and Firefighter Schira:

  • A delayed arrival at the incident scene that allowed the fire to progress significantly;
  • A failure to adhere to fundamental firefighting practices; and
  • A failure to abide by fundamental firefighter self-rescue and survival concepts

 Although the aforementioned factors were believed to have directly contributed to their deaths, they might have been prevented if:

  • Some personnel had not been complacent or apathetic in their initial approach to this incident;
  • Some personnel were in a proper state of mind that made them more observant of their surroundings and indicators;
  • The initial responding units were provided with all pertinent information in a
  • timely manner relative to the incident;
  • Personnel assigned to Engine 102 possessed a comprehensive knowledge of their first-due response area;
  • A 360-degree size-up of the building accompanied by a risk – benefit analysis
  • was conducted by the company officer prior to initiating interior fire suppression operations;
  • Comprehensive standard operating guidelines specifically related to structural
  • firefighting existed within the department;
  • The communications system users (on-scene firefighters and those monitoring the incident) weren’t all vying for limited radio air time;
  • The communications equipment and accessories utilized were more appropriate for the firefighting environment;
  • Certain tactical-level decisions and actions were based on the specific conditions;
  • Personnel had initiated fundamental measures to engage in if they were to become disoriented or trapped inside a burning building; and
  • Issued personal protective equipment was utilized in the correct manner.

 

 

References

WLTW.com Previous Stories:

 

Don’t forget to LIKE Buildingsonfire on FaceBook and follow CommandSafety on Twitter

Engineered Structural Support (ESS) system: Been in the Field lately?

No comments

Been in the field lately looking at your buildings under construction? Here’s a new look at a common Engineered Structural Support (ESS) system.

Here’s  today’s Taking it to the Streets session; Take a look at this Engineered Structural Support (ESS) system. There are two critical component systems depicted here in this photo- can you tell what they are? Take a close look at the ESS T…russ components. They are nothing new, but they do cause a stir when they make their way back into main stream fire service discussions as firefighters and officers “rediscover” these type of systems, their use, presence and operational risk and profiling.

So let’s start the dialog:

  • Can you name the type of ESS Truss, the inherent characteristics, design and function | typical applications | risks and operational concerns.
  • What impact will fire impingement have on the ESS assembly in either foor or roof systems?
  • How can you identify these assemblies and building characteristics unpon arrival?
  • What fireground strategies and tactics would you employ upon arrival at an occupancy with this type of ESS?
  • Don’t forget to look at the second system component that I mentioned earlier;
  • Can you identify it? Its relationship to the other system and other inherent performance issues?

 

 

Lots to talk about, look at and share. Any street stories to share-please post. I’ve got a few more in this series to post after we get some dialog and insights….
We’ve cross posted this on our Buildingsonfire Facebook page (HERE), if you haven’t checked it out, please follow the link, there’s been some great discussions and insights being shared from around the country…
Don’t forget to spread the word about Buildingsonfire.com \ CommandSafety.com and Buildingsonfire on FB…send the links along and like….Dont forget about CommandSafety on Twitter and Buildingsonfire on twitter also.

Worcester FF Brian Carroll recalls the Arlington Street Fire of December 8, 2011

No comments

Firefighter Brian Carroll reflects on the 2011 Arlington Street Fire and Cold Storage Fire of 1999.

Firefighter Brian Carroll was trapped in the basement of 49 Arlington St. after the second-floor of the three-decker collapsed underneath him and his partner on Rescue 1. He thought his close friend was OK. Firefighter Carroll lay trapped and didn’t learn until after he was freed that Firefighter Davies had died.

“What happened to my brother, the three-decker collapsed in a way no one could predict,” Robert Davies said. “Certainly I think it serves as a lesson going forward, and even if it saves one life going forward, then at least something good came out of it.”

Firefighter Davies, who was 43 when he died, has a son, Jon D. Davies Jr., in the department now as a firefighter.

  • From the Worcester Telegram & Gazette;  A cruel month for Worcester firefighters HERE
  • NIOSH REPORT Career Fire Fighter Dies and Another is Injured Following Structure Collapse at a Triple Decker Residential Fire – Massachusetts: HERE

San Francisco FD Berkeley Way Double LODD Report Issued: Routine Fire….

No comments

Charlie Side Fire View

 
 
 The Chief of the Department directed the Department Safety Officer to conduct a Safety Investigation of this incident. The primary purpose of the investigation was to identify and analyze the contributing factors that led to the incident as well as to create situational awareness to prevent future occurrences. The main objective of the Team’s investigation and subsequent report was to discover the key factor that led to the fatal outcome of two Firefighters. The SFFD report contains the findings and recommendations to help prevent Firefighter injuries or fatalities in the future.

 

In analyzing and recording these events, the Investigation Team acknowledges and respects that members confronted a challenging situation. On‐scene personnel reacted quickly to the changing conditions at this incident. We request that every person who reads this report show respect, appreciation and consideration for all personnel who responded to this incident.

As is a common industry practice, for this report Lieutenant Vincent Perez was referred to as Victim 1 and Firefighter Paramedic Anthony Valerio was referred to as Victim 2, with the exception of the Rescue Events Section.

 Excerpt from Chief of Department’s Letter

“On Thursday, June 2, 2011 at 10:45 a.m., the San Francisco Fire Department responded to Box 8155, at 133 Berkeley Way. What was seemingly a routine working fire in a single family residence quickly transformed into a fierce and unrelenting incident with ultimately tragic results.

When we answered the call to a career in the Fire Service and took our Oath of Allegiance, we were aware of the inherent danger of our occupation. Despite this awareness, we do not expect to encounter a line of duty death of a brother or sister, especially not in our very own Department. The profound loss of Lieutenant Vincent Perez and Firefighter/Paramedic Anthony Valerio has left an indelible impression in our hearts and will forever be remembered in the annals of SFFD history.

Even as we mourned our fallen brothers in the early days after the tragedy, our Department began the painful and difficult, but necessary, steps of a Line of Duty Death investigation. We were resolute in understanding what occurred during those fateful minutes and compelled to uncover any recommendations for improvement that may arise to future operations so that their passing will not have been in vain. For over six months, the Investigative Team worked tirelessly, scrutinizing every piece of evidence in order to produce a comprehensive report.”

SFFD

 

Joanne Hayes‐White

Chief of Department

 

 

 

Executive Summary and Report Excerpt

On June 2, 2011 at 10:45 hours, the San Francisco Fire Department was dispatched to a report of a fire in the building at 133 Berkeley Way in the City’s Diamond  Heights neighborhood. The first unit arriving on the scene, Engine 26, observed light smoke showing from the garage of the 4 story (2 above grade, 2 below grade) wood framed building, detached on the Bravo side.

 

Aerial from the Charlie Side

An aggressive interior fire attack was initiated through the front door, which is on a level between the ground level and second floor. After investigating the garage (ground level), Engine 24, the second Engine on the scene, led a small line through the garage to the interior door to back up the first Company. Battalion 9 was assigned Fire Attack by Battalion 6, who had assumed Command. Battalion 9 entered the fire building and, after conferring face to face with Engine 26 on the first floor (ground level), concluded that the fire was below them.

 

Alpha Side Operations

Battalion 9 exited the building and proceeded to the Bravo side to check for an entrance leading directly to the fire floor. Engine 11 led a large line wye to the driveway with the intention of leading a 1 ¾ inch line through the garage. They were redirected by Battalion 6 to make their lead down the Bravo side of the building to Sublevel 1 (one floor below grade) to assist Battalion 9. The Division Chief, upon arrival, assumed Command. He assigned Battalion 6 to Division 3 (ground floor).

Truck 15 was assigned Roof Division. Truck 11 split their crew, two members to the roof and three members to search and ventilate the top floor of the fire building. The Rescue Squad was ordered to conduct a search. Two members initially attempted to make entry through the garage but, due to extreme heat conditions, redeployed and entered through Sublevel 1 on the Bravo side.

The other two members of the Rescue Squad made entry through the front door, were pushed back by the heat and then made a successful second effort and conducted a search of the top floor.

 

In the course of fireground operations, members of several Companies came upon the stricken members on the first level and removed them from the building. All possible efforts were employed to revive the members and they were transported to San Francisco General Hospital (SFGH). One member (Victim 1) succumbed to his injuries that day and the second member (Victim 2) succumbed to his injuries two days later. Two other Firefighters were treated at SFGH for various injuries and released that day.

The Medical Examiner determined the cause of death for both members was due to complications from external and internal thermal injuries. Both victims suffered burns to 40% of their body surface. This fire was determined to be accidental by the SFFD Fire Investigative Unit. The fire originated on Sublevel 1, on the West side of the family room, near the large floor to ceiling windows. The ignition was a non‐specific electrical sequence in the electrical wiring or appliance (handheld vacuum cleaner) in this area.

There was a delay in reporting the fire due to the occupants’ attempting to extinguish it on their own. (SFFD Fire Investigation Report 11‐0500532)

The investigation identified that the failing of the window on Sublevel 1, located near the seat of the fire and directly across the stairwell leading to the ground floor, led to the extreme fire behavior which ultimately caused the death of two Firefighters. This fire was in a stage of deprived oxygen when the window failed, causing a rapid extreme high heat event to occur. The extreme heat followed the natural flow path up the interior stairs where Victims 1 and 2 were located.

The Safety Investigation Team found no conclusive evidence that the members were exposed to direct flame impingement during this rapid extreme heat event. However,

Victims 1 and 2 received varying degree of burns up to 40% of their body. The investigation concluded that this was caused by the rapid extreme heat conditions that radiated through their Personal Protective Equipment (PPE) to their bodies. These temperatures exceed the ability for human survival regardless of PPE.

The PPE was inspected and evaluated by NIOSH and the manufacturer. Both reviewing parties concluded that the PPE performed to its specifications and design. The manufacturer concluded that the PPE was exposed to temperatures in the range of 550‐ 700°F. These extreme temperatures were short in duration which caused limited damage to the outer shell of the PPE.

The Safety Investigation Team noticed severe heat damage to the portable radios remote speaker/microphones on Victims 1 and 2 and had the radios tested. The testing indicated that the remote speaker/microphones failed to operate correctly due to heat damage. The Safety Investigation Team was not able to determine, after testing, exactly when the remote speaker/microphones failed. The investigation has shown that multiple attempts were made to contact Engine 26 with no response.

The investigation also found that no radio transmissions of distress were received from Victims 1 or 2. Command and Control of any incident in the San Francisco Fire Department is acquired and maintained through the use of the Incident Command System (ICS).

The Incident Command System provides the tools for clear objectives, a single action plan, clear and acknowledged communications, and accountability for all members assigned to an incident. At this incident, some of the components of Incident Command System that were not followed include:

  • Single action plan
  • Fireground Accountability

From these findings, this report makes recommendations for several areas of the Department, including:

  • Training
  • Equipment
  • Policy Development
  • Policy Enforcement

The Safety Investigation Team gathered and analyzed many facts and conducted interviews of members directly involved in this incident. The Team identified several factors that occurred that contributed to the deaths at this incident.

These factors include:

  • Extreme heat conditions accelerated by the failure of a window on the fire floor.
  • Layout of building
  • Excessive live fuel load which contributed to the growth of the fire

Conclusion

This incident appeared from the onset to be a routine “room and contents” fire that the SFFD encounters on a regular basis. As the Companies were performing standard fireground operations, the incident rapidly deteriorated due to a hostile fire event. The failure of a window in the fire room allowed fresh oxygen to enter the room, providing a fire that was deprived of one of the key elements of combustion to rapidly intensify.

Due to the growth of the fire, the room flashed, causing extreme and rapid heat conditions which traveled up the interior stairs (the flow path) to the location which our members were operating. Our members were caught in this high heat, causing the injuries that ultimately claimed their lives.

Due to this fire event, other Companies attempting to conduct fireground support operations were prevented from making entry into the structure from street level (through garage) to back up Engine 26. These Companies were forced to regroup and find an alternate point of entry. In the process of doing so, crews made entry from the Bravo side directly into the fire room and extinguished the fire. This allowed members to make entry from above which led to the discovery and rescue of our members.

These events happened in a time frame of less than fourteen minutes.

 During the course of this investigation, the Safety Investigation Team recognized that no matter how experienced or properly prepared we are, we must always approach all incidents with the utmost awareness.

This incident showed that a simple failure of a piece of glass/window caused unforeseeable and fatal consequences.

We, as a Department, need to gain further knowledge and understanding of the following:

  • Having Situational Awareness prior to taking action, this would include the ongoing process when conditions change
  • How Risk Management must be used when making all decisions
  • Limitations of the PPE (turnouts, SCBA, and equipment)
  • Building construction, including layout and how fire/smoke will
  • move within the structure
  • Ventilation practices and how they affect fire conditions
  • Importance of Communications for all members operating on the scene
  • Companies must use strict discipline when assigned task/locations

Previous  CommandSafety Coverage from 2011, HERE, HERE  and HERE

Previous Coverage on CommandSafety.com below:

Other Links;

Reports were published in the San Francisco Chronical, HERE  and HERE.

SFFD Report PDF, HERE


 

SFFD Web Link, HERE

SFFD Mission

The mission of the Fire Department is to protect the lives and property of the people of San Francisco from fires, natural disasters, and hazardous materials incidents; to save lives by providing emergency medical services; to prevent fires through prevention and education programs; and to provide a work environment that values health, wellness and cultural diversity and is free of harassment and discrimination.

SFFD Color Seal

IN TRIBUTE TO
OUR FALLEN HEROES
 

 

Alpha Side

 

 STRUCTURE DESCRIPTION

Site overview: Steep downhill slope adjacent to Glen Canyon

Date of Construction: 1975

 

 Building overview:

  • Attached garage located in the front of the house. Main structure is 2 stories above grade and 2 stories below grade

 Type of Construction:

  • Four story, Type 5 wood framed, single family home, detached on three sides
  • Approximate square footage: 4,000 sq ft.
  • Four stories of living space
    • First Floor (Ground floor): garage, 3 bedrooms, 2 bathrooms
    • Second floor: dining room, living room, kitchen, bathroom and family room
    • Sublevel 1: large family room (origin of fire), mechanical room, bathroom, bedroom, balcony, side entrance on Bravo side
    • Sublevel 2: enclosed finished storage area, bathroom (no windows)

 Construction features:

  • Roof type: Flat roof, bitumen roofing membrane, normal dimensional lumber
  • Exterior: siding T1-11 plywood, 5/8”
  • Interior: drywall over normal insulated framing
    • Note: Fire origin room had decorative plywood veneer panels over drywall
  • Steel I beams wrapped in drywall were used as structural supports
    • Note: Fire origin room had a steel I beam that spanned horizontally from Bravo to Delta side
  • Rear of structure had extensive use of glass to capture views, including windows and sliding doors
  • Second floor and Sublevel 1 (fire origin) had large balconies
  • Flooring consisted of tile, carpet and sheet vinyl throughout the house
  • Dual glazed windows throughout, installed in 2003
  • Ground level had a two car garage with access to residence
    • Note: Two large vehicles occupying garage at time of fire
  • Main entrance was accessed by ascending a flight of stairs adjacent to the garage
    • Note: Main entrance stairs led to an interior landing which allowed access to top floor (5 stairs up) or grade level (7 stairs down)
  • Sublevel 1 had an access door from the exterior Bravo side along with access from interior stairs
  • Sublevel 2 had access door from exterior Bravo side. (no interior access)
    • Note: Access through the Bravo side was difficult due to unfinished terrain and poor housekeeping

 

 

 

 

 

SFFD Diamond Heights LODD Safety Violations

2 comments

State investigators have cited the San Francisco Fire Department for “serious” worker safety violations in the deaths of two firefighters killed battling a Diamond Heights house fire in June. Reports were published in the San Francisco Chronical, HERE  and HERE.

 Firefighters lost track of Lt. Vincent Perez, 48, and firefighter-paramedic Anthony Valerio, 53, after they went into the four-level home at 133 Berkeley Way on June 2 and failed to respond quickly to the men’s last radio communication, investigators with the state Department of Industrial Relations’ Division of Occupational Safety and Health said in a report issued Monday.

In recommending that the Fire Department be fined $21,000, the state investigators also said the department had violated state rules requiring that two firefighters be designated outside to assist any two firefighters who venture into a life-threatening environment.

Only one firefighter from Perez and Valerio’s engine company – the first on the scene – was available to come to their help during the blaze, the investigation found.

The state also cited the Fire Department for an incident – evidently before the fatal flareup – in which an unidentified battalion chief ventured into the burning building alone, without keeping in contact with Perez and Valerio. That was also deemed a serious violation of safety rules.

“These are serious in that they had protocols in place, but they weren’t following them,” said Erika Monterroza, spokeswoman for the worker safety agency. “There’s no question that a lack of communications was a big issue here. The investigator found there was a breakdown there.”

Fire Chief Joanne Hayes-White said the department would appeal the findings. She said state officials have told her commanders that the violations fell short of finding the department’s actions responsible for the two firefighters’ deaths. “None of the citations involved a direct cause of the line-of-duty deaths,” Hayes-White said. Monterroza confirmed that, saying the exact circumstances of the firefighters’ deaths could not be determined.

Valerio, Perez and a third member of Engine Company 26 in Diamond Heights were the first firefighters to arrive at the mid-morning blaze, which started when a sparking electrical outlet set curtains on fire.

The third firefighter manned the pumper hose while Valerio and Perez went inside to fight the fire, but the safety regulations require a fourth firefighter to be available outside to assist.

A scene commander, identified by firefighters as Battalion Chief Thomas Abbott, ordered a crew from Engine Company 24 to back up Valerio and Perez inside the building. For several minutes, however, scene commanders tried to find the Engine 26 firefighters, without success.

There was an unspecified gap between that last communication and any effort by firefighters to respond over the radio or track down the men, the state investigation found.

The reports goes on to state that Hayes-White said the department’s investigative report – still in draft form – concluded that the fire had melted one of the firefighters’ microphone cords, cutting off communications. She said any delay in firefighters’ response would be addressed in the final report.

Firefighters ultimately found Perez and Valerio in a landing area and carried the injured men outside. Perez was pronounced dead at San Francisco General Hospital, and Valerio died there two days later.

The state probe also faulted the actions of the unnamed battalion chief who went into the building “alone and also did not remain in contact with the firefighters who were inside.”

Hayes-White said the battalion chief had gone inside only briefly, had seen Perez and Valerio alive and had never been out of other firefighters’ view.

Read more: http://www.sfgate.com/cgi-bin/article.cgi?f=/c/a/2011/12/02/BANQ1M7JBO.DTL#ixzz1fUEug7hu

Previous Coverage on CommandSafety.com below:

 

FDNY: The 23 Street Collapse October 17,1966 Box 55 598

No comments

Accessed from FDNY - Remembering the "23rd Street Fire" October 17, 1966, Facebook Page

On October 17th 1966, Manhattan Box 598 was struck at 21:36 hours for the report of a building fire at 7 East 22nd Street, an art dealer in a four story brownstone. On arrival, the heat and smoke was so intense companies could not make entry through the art dealer, and so attempted to make entry by way of the abutted building 6 East 23rd Street, The Wonder Drug store.

Crews were dealing with a very intense and spreading fire. With companies operating above the fire, little indication of a catastrophic collapse was present. Suddenly, a 16×35 foot section of the floor collapsed at around 22:39 hours causing ten firefighters to fall into the burning cellar. Two other firefighters on the first floor were killed in a burst of heat.

Firefighters evacuated immediately, except for some whom were trapped on the roof with direct flame impingement. Hand lines from the ground and a truck company ladder was able to rescue the group in time. Rescue operation ensued long into the morning. Several evacuations were ordered, and further collapses occurred. Aside from 9/11, this was the largest single line of duty death event in the FDNY’s history.

Stored in the basement of the art dealer were large quantities of highly flammable lacquer, paint, and finished wood frames. The first floor was supported by 3″ x 14″ wood beams. 3/4″ wood planking atop these beams was covered with five inches of concrete finished with terrazzo and insulated against all heat to the firefighters operating above. As part of a recent project, a common cellar under the two buildings was renovated, removing a load-bearing dividing wall that had supported the floor above. The cellar of the art dealer extended under the drug store illegally from this renovation.

The fire burned unknowingly in the Wonder Drug basement for over an hour when it finally collapsed. It took 14 hours to locate all downed firefighters in the rubble; the cause of the fire is unknown.

Building Construction Insights

  • Location of Fire Origin: Cellar of 7 East 22 St.
  • Location of Collapse: First floor of Exposure 3 building: 6 East 23 St. “The Wonder Drug Store.”

Fire Building Construction:

  • 7 East 22 St: a brownstone, 20 x 60 brick and joist, four story residence.
  • The cellar, where the fire started, and first floor were occupied by an art dealer.
  • The cellar extended under the first floor of Wonder Drug for approximately 35 feet.

Collapse Building Construction:

  • 6 East 23 St: a five story, 45 x 100 commercial building, brick & joist construction.
  • The rear, 16 x 35 foot, section of the first floor collapsed into the cellar occupied by 7 East 22 St.
  • The rear and side walls butted up to a 3-story white brick commercial building to the West at 3940-948 Broadway and to a 5-story brown brick building to the North at 6 East 23rd Street

    Diagram NY Times (2006) Accessed from the internet 10.18.2011

 

Building Alteration

(1) The fire building, 7 East 22 St, had a two story extension which abutted the rear of 6 East 23 St.

(2) The Cellar of 7 East 22 St extended under the first floor of 6 East 23 St for approximately 35 feet.

(3) The floor construction of 6 East 23 St was 3″ x 14″ wood beams topped by 3/4″ wood planking. On top of this, five inches of concrete with a terrazzo finish was added.

 The firefighters in exposure 3, (6 East 23 St), killed in the collapse did not know they were operating directly over the cellar fire in 7 East 22 St. The five inch concrete terrazzo floor acted as an insulator.

It concealed the severe fire and heat below. The 3 inch x 14 inch floor beams spaced 16 inches on center were reduced in size and strength by the fire.

The first sign of weakness was the sudden collapse of a 15 x 35 foot section, which plunged the ten firefighters to their deaths. Two other firefighters were killed on the first floor by a ball of flame.

The 5-alarm fire wasthe single worst loss of New York City firefighters in the line of duty prior to Sept. 11, 2001. 
 

FDNY LODD Twelve Members of Every Rank

Twelve members of every rank, from a probationary firefighter to a deputy chief, made the Supreme Sacrifice when the ground floor of the Wonder Drug store collapsed. The fire originated in a basement storage area, which was concealed by a four-inch thick cinderblock wall, illegally constructed by the building’s previous owner.

  • DC Thomas A Reilly, Division .3
  • BC Walter J Higgins, Battalion. 7
  • Lt John J Finley, Ladder 7
  • Lt Joseph Priore, Engine 18
  • Fr John G Berry, Ladder 7
  • Fr James V Galanaugh, Engine 18
  • Fr Rudolph F Kaminsky, Ladder 7
  • Fr Joseph Kelly, Engine 18
  • Fr Carl Lee Ladder, 7
  • Fr William F McCarron, Division 3
  • Fr Daniel L Rey, Engine 18
  • Fr Bernard A Tepper, Engine 18

 

From NYFD.com http://nyfd.com/history/23rd_street/23rd_street.html

 

 

A wreath is laid at the new plaque honoring the 12 FDNY members killed at the 23rd Street fire on Oct. 17, 1966. © FDNY Photo Unit.

FDNY Remembers the 23rd Street Fire on its 45th Anniversary

Remembrance: FDNY and Buffalo(NY) Double LODD from Floor Collapse

1 comment

 

Dangers of Floor Collapse

Take the time to revisit two Firefighter LODD incidents that both occurred in the month of August in 2006 and 2009 respectively. Excerpts from the NIOSH Reports have been included that are part of the NIOSH FIRE FIGHTER FATALITY INVESTIGATION AND PREVENTION PROGRAM (HERE).

Both of these incidents involved a double firefighter line-of-duty death (LODD) and resulted from a floor collapse during the conduct of operations within the fire involved structures. There are numerous lessons learned and recommendations that can be considered and applied in organizations and agencies across the country, both large and small; career or volunteer.

These incidents bring to light the occupancy risks present in some of our most common of building occupancies, and continue to provide the basis for operational considerations and management based upon occupancy risk versus occupancy type. There are numerous operational considerations when addressing fires located in basement or underdeck areas and the subsequent management of those incidents based upon known or assumed building characteristics, occupancy risk and profile, inherent or presumed building stability and potential for structural compromise and the operational risk from isolated or catastrophic of collapse.

  • Buffalo (NY) Fire Department: August 24, 2009
  • FDNY: August 27, 2006

Some Other Links related to Floor Collapses and Reference Links for Operational Insights and Operating Experience (OE)

Here are some Safety Considerations related to Residential Occupancies (non-inclusive) for Operations at Basement Fires that will support fireground operational safety:

  • Conduct a thorough fire size-up and communicate the findings to all personnel on-scene before entering the building.
  • Conduct an assessment of the Building Profile ( building construction type, structural assembly systems and features and age) and assesss fire behavior and intensity levels.
  • Ensure an adequte Risk Assessement is conducted and that Risk versus Gain is determined
  • Maintain situational awareness throughout the tactical deployment of crews within the interior of the structure
  • Conduct a 360 degree perimeter assesement when feasible to determine access and egress points, fire location and travel and other mission critical operational perameters.
  • Incident commanders and company officers should be trained and experienced in structure fire size up to avoid putting fire fighters at unneeded risk of working above fire-damaged floors.
  • Do not enter a structure, room, or area when fire is suspected to be directly beneath the floor or area where fire fighters would be operating, or if the location of the fire is unknown.
  • Never assume structural safety of any floor (regardless of the construction) having a significant fire under it.
  • Conduct pre-incident planning inspections during the construction phase to identify the type of floor construction.
  • If pre-planning is not conducted, assume residential construction and small commercial buildings built since the early 1990s may contain engineered wood I-joists.
  • Report construction deficiencies noted during preplanning to local building code officials. For example, engineered wood floor joists should only be modified per manufacturer specifications—usually limited to cutting to length and removing pre–cut knockouts for utility access. Report damaged or cut chords or webs to building officials.
  • Develop, enforce, and follow standard operating procedures (SOPs) on how to size up and combat fires safely in buildings of all construction types. Rapid intervention teams (RIT) should include a portable ladder with their RIT equipment when deployed at basement fires.
  • Ensure Time Compression is considered: Ensure Command has the ability to monitor progress or elapsed incident time and adjusts strategic and tactical plans accordingly and in a time effective manner. 
  • Provide training on identifying signs of weakened floor systems (soft or spongy feel, heat transmitted through floor, downward bowing, etc.).
  • Make fire fighters aware that all floor types can fail with little or no warning.
  • Use a thermal imaging camera to help locate fires burning below or within floor systems, but recognize that the camera cannot be relied upon to assess the strength or safety of the floor. (Refer to the recent UL Test Data and Operational Safety Considerations ”Structural Stability of Engineered Lumber in Fire Conditions” available at http://www.uluniversity.us/ )
  • Fire fighters should be trained on the use of thermal imaging cameras, including limitations and difficulties in detecting fire burning below floor systems. (See reference to UL above)
  • Immediately evacuate and, if possible, use alternate exit routes when floor systems directly beneath the floor where fire fighters would be operating are weakened by fire.
  • Use defensive overhaul procedures after fire extinguishment in structures containing fire-damaged floor systems of all types.
  • Consider becoming active in the building code process and influence requirements for fire resistance of floor and ceiling systems to further fire fighter safety and health.
  • Ensure RIT personnel area staged and have complete a site assessment of the building and occupany upon thier arrival and set-up
  • Ensure that a rapid intervention team (RIT) is on the scene as part of the first alarm and in position to provide immediate assistance prior to crews entering a hazardous environment
  • 

REMEMBRANCE  

Buffalo (NY) Fire Deparment- August 24, 2009  1815 Genesee Street, Buffalo, NY 

Career Lieutenant Dies Following Floor Collapse into Basement Fire and a Career Fire Fighter Dies Attempting to Rescue the Career Lieutenant – New York (REPORT HERE)

The Structure, (pre-fire conditions)

SUMMARY

On August 24, 2009, a 45-year-old male career lieutenant (Victim #1) died following a partial floor collapse into a basement fire, and a 34-year-old male career fire fighter (Victim #2) was fatally injured while attempting to rescue Victim #1. The career fire department was dispatched for “an alarm of fire” with reported civilian(s) entrapment. Arriving units discovered a heavily secured mixed commercial/residential structure with smoke showing. Following failed initial attempts to locate an entry to the basement, crews located a door on Side 2 that provided access down a flight of stairs to a basement entry door. Repeated attempts were made to force open this basement door in order to search for trapped civilians, but crews had difficulty gaining access through this door because it was made of steel and locked and dead-bolted on both sides. Other crews on scene performed primary searches of the 1st and 2nd floors with no civilians found.

Approximately 30 minutes into the basement fire, command ordered all interior crews to exit the structure to regroup because crews were still unable to gain access into the basement from Side 2. Additional manpower was sent with special tools to assist in breaching the basement door on Side 2. Victim #1 and two fire fighters from his crew entered into the structure from Side 1 to verify all fire fighters had exited a 1st floor deli. Victim #1, following a hoseline into the structure, was well ahead of the other two fire fighters when the 1st floor partially collapsed beneath him. Victim #1 fell with the floor into the basement, exposing him to the basement fire. The other two fire fighters immediately exited the deli after fire conditions quickly changed and shelving and displays fell on them; they were unaware of what had just occurred. Victim #1 made several Mayday calls from within the structure and activated his PASS device. Confusion erupted exteriorly on scene when trying to verify who was calling the Mayday, their exact location, and how they got into the basement. The incident commander was aware that he had crews attempting to gain access into the basement from Side 2 but was unaware that there had been a floor collapse within the deli section of the structure.

Simultaneously, Victim #2, a member of the fire fighter assistance and search team (FAST), was standing by outside Victim #1’s point of entry when the Mayday calls came out. It is believed that Victim #2 knew where Victim #1 was since he had gone in the structure with him earlier in the incident. Victim #2 grabbed a tool, went on air, and rushed into the structure. The FAST and additional personnel on scene concentrated on Side 2 initially while other fire fighters followed an unmanned hoseline into the deli. Crews within the deli quickly discovered a floor collapse and reported hearing a PASS device alarming. Victim #1 was immediately identified as missing during the first accountability check, but Victim #2 was not accounted for as missing until the third accountability check, more than 50 minutes after Victim #1’s Mayday. After the fire was controlled, both victims were discovered side-by-side in the basement where the 1st floor had partially collapsed. They were found without their facepieces on and with SCBA bottles empty. Victim #1’s PASS device was still alarming. They were pronounced dead on scene. Four fire fighters and one lieutenant suffered minor injuries during the incident. No civilians were discovered within the structure.

F2009-23 Aug 24, 2009 Career lieutenant dies following floor collapse into basement fire and a career fire fighter dies attempting to rescue the career lieutenant – New York PDF Adobe PDF file

Key contributing factors identified in this investigation include working above an uncontrolled, free-burning basement fire; interior condition reports not communicated to command; inadequate risk-versus-gain assessments; and, crew integrity not maintained.

NIOSH has concluded that, to minimize the risk of similar occurrences, fire departments should:

  • Ensure that all personnel are aware of the dangers of working above a fire, especially a basement fire, and develop, implement, and enforce a standard operating procedure (SOP) that addresses strategies and tactics for this type of fire.
  • Ensure that the incident commander (IC) receives interior status reports and performs/continues evaluating risk-versus-gain.
  • Ensure that crew integrity is maintained at all times on the fireground.
  • Ensure that the incident commander (IC) receives accurate personnel accountability reports (PAR) so that he can account for all personnel operating at an incident.
  • Ensure that a separate incident safety officer, independent from the incident commander, is appointed at each structure fire.
  • Ensure that fire fighters use their self-contained breathing apparatus (SCBA) and are trained in SCBA emergency procedures.

Additionally, manufacturers, equipment designers, and researchers should:

  • Conduct research into refining existing and developing new technologies to track the movement of fire fighters inside structures.
  • Continue to develop and refine durable, easy-to-use radio systems to enhance verbal and radio communication in conjunction with properly worn self-contained breathing apparatus (SCBA)

    Fire and Rescue Operations

     

Front of structure
Incident scene.
(Photo courtesy of fire department. From NIOSH REPORT)

 

RECOMMENDATIONS

Recommendation #1: Fire departments should ensure that all personnel are aware of the dangers of working above a fire, especially a basement fire, and develop, implement, and enforce a standard operating procedure (SOP) that addresses strategies and tactics for this type of fire.

Discussion: Basement fires can be taxing and test a fire fighter’s knowledge and skill on how to combat it safely and effectively. Fire burning underneath floors can significantly degrade the floor system with little indication to fire fighters working above.1 They need to be aware of rapid heat buildup, little or no ventilation, limited accessibility, and whether it is a storage place for unknown hazards (e.g., combustibles, hazardous materials, and flammable liquids). Also of concern for fire departments is how to determine how long a fire has gone undetected. Fire fighters should be aware of what is stored on the floor directly above a basement fire, what the finished floor is comprised of (e.g., terrazzo, plywood, tongue-and-groove, tile, etc.), and what the floor structural members are comprised of (e.g., engineered wood floor joists, concrete, or steel). Structural support members may be directly exposed to fire, causing them to weaken and increase the likelihood of an above-floor collapse. Interior crew(s) intending to operate on the floor above a basement fire should limit their operating time, especially if ventilation, suppression, and accessibility are not progressing. The floor’s structural members will continue to weaken as fire and heat intensify. Specifying an exact length of time for how long suppression crew(s) should operate above a basement fire is questionable, and the IC should make that determination by performing a hazard analysis/risk assessment. The fire department did not have an SOP specifically addressing strategies and tactics when combating basement fires. SOPs should be developed to address structural fire fighting operations specific to basement fires, because these types of fires present a complex set of circumstances and following established SOPs will minimize the risk of serious injury to fire fighters.

During this incident, fire fighters were unable to access the basement, unable to ventilate the basement fire, and unaware of the fire load found within the basement. Initially, the department did not cut a hole in the 1st floor apartment or deli and use their Bresnan distributor, in fear of injuring reported trapped civilians. Note: The Bresnan distributor is a type of cellar nozzle used to suppress fire through steam conversion. The use of a cellar nozzle, like a Bresnan distributor, during the initial stages of the basement fire may have assisted in containing the fire and/or allowing better operating conditions for fire fighters to access the basement.2 Attempts were made to flow water on the 1st floor where fire had vented through, but this effort was not successful. Fire fighters should also recognize that fire venting through a floor is a late indication of a weakened floor system.

Recommendation #2: Fire departments should ensure that the incident commander (IC) receives interior status reports and performs/continues evaluating risk-versus-gain.

Discussion: Among the most important duties of the first officer on the scene is conducting an initial size-up of the incident. A proper size-up begins from the moment the alarm is received, and it continues until the fire is under control. The size-up should also include assessments of risk-versus-gain during incident operations, especially after primary searches have been conducted.2-7 The size-up should include an evaluation of factors such as the fire size and location, length of time the fire has been burning, conditions on arrival, occupancy, fuel load and presence of combustible or hazardous materials, exposures, time of day, and weather conditions. Information on the structure itself should include size, construction type, age, condition (e.g., evidence of deterioration, weathering), evidence of renovations, lightweight construction, loads on roof and walls (e.g., air conditioning units, ventilation ductwork, utility entrances), and available preplan information are all key information that can affect whether an offensive or defensive strategy is employed. The incident commander should be willing to change his strategy and plan based on continued size-ups and risk assessments until the fire is brought under control. Conducting accurate size-ups and receiving interior/exterior status updates is critical to the safety of fire fighters on the incident, rescue/recovery efforts, and overall control of the incident. “The decision to commit interior firefighting personnel should be made on a case-by-case basis with proper risk-benefit decisions being made by the incident commander. The commitment of firefighters’ lives for saving property and an unknown or marginal risk of civilian life must be balanced appropriately.” 8 The fireground is very dynamic, and conditions can either improve or deteriorate based on fire suppression activities, and available resources, and most importantly assessments/size-ups of the incident are necessary to detect a change on the fireground.

During this incident, the fire department was attempting to gain access to reported trapped civilian(s) in a basement. The command post was established at the front of the structure providing views of Side 1 and Side 2. The basement contained heavy smoke and fire and was inaccessible from exterior and interior access doors. The initial IC and the IC who assumed command performed initial size-ups and received radio updates on fire and smoke conditions from personnel working on the incident, but not all interior findings were reported. Crews working in the 1st floor apartment encountered fire venting through the floor on Side 4 as early as 9 minutes after the first apparatus arrived on scene. Ten minutes later, Victim #1 was flowing water on fire that had vented in the corner of Side 3 and Side 4 of the deli. This was the same general area where crews within the 1st floor were working. The only thing separating the apartment and deli was a wall of floor coolers. The basement fire burned uncontrolled for more than 30 minutes while fire fighters continued attempts to gain access to the basement. Incident updates on the radio included transmissions such as “untenable” and “time to get out,” prior to the 1st floor partial collapse. The IC also mistook “water on the fire” as fire fighters actually attacking the basement fire from Side 2. This provided the IC with a false sense of progress on combating the basement fire. Also, during this incident, the IC was at times monitoring multiple radio channels and some additional transmissions may not have been received. Radio transmissions are very important for the IC to hear, acknowledge, and prioritize so that the IC can maintain situational awareness, and accurately and effectively manage and direct fireground operations. A chief’s aid or incident command technician assigned to the IC may have assisted the IC in monitoring the fireground channels and distinguishing key radio traffic and updates. It is reasonable to believe that, as time progressed and basement fire conditions continued to be uncontrolled, that the chances of survival diminished for any potentially trapped civilians exposed to the heat or products of combustion found within the smoke. According to fire investigators with the fire department, only the bodies of Victim #1 and Victim #2 were found within the structure.

Recommendation #3: Fire departments should ensure that crew integrity is maintained at all times on the fireground.

Discussion: Fire fighters should always work and remain in teams whenever they are operating in a hazardous environment.2 Team integrity depends on team members knowing who is on their team and who is the team leader; staying within visual contact at all times (if visibility is low, teams must stay within touch or voice distance of each other); communicating needs and observations to the team leader; and rotating together for team rehab, team staging, and watching out for each other (e.g., practicing a strong buddy system). Following these basic rules helps prevent serious injury or even death by providing personnel with the added safety net of fellow team members. Teams that enter a hazardous environment together should leave together to ensure that team continuity is maintained. 3

During this incident, raw video captured the FAST working on Side 1 of the structure (same side that Victim #1 had entered) during Victim #1’s “Mayday.” At the same time, Victim #2, assigned to the FAST, was seen pointing at Side 1, donning his SCBA, and entering the structure as other fire fighters were exiting from Side 1. The FAST was activated and ordered to Side 2 where it was believed the “Mayday” transmission came from. Victim #2 went missing following the “Mayday” and his whereabouts were unknown until the recovery of Victim #1. Also, Victim #1 entered the deli not realizing that two of his team members from R1 were not following behind. Not verifying your crew is with you and/or working alone increases the risk to individuals and possibly to others during search and rescue efforts. During interviews, the fire department commented on an increase in “freelancing” following the Mayday.

floor collapse from inside the building
Photo 6. Interior view of deli following partial floor
collapse and recovery operations.
(Photo courtesy of police photographer. From NIOSH REPORT)
basement storage basement storage
Photo 7 . Views of materials stored within basement.
(Photos courtesy of police photographer. From NIOSH REPORT)

 

Recommendation #4: Fire departments should ensure that the incident commander (IC) receives accurate personnel accountability reports (PAR) so that he can account for all personnel operating at an incident.

Discussion: An important aspect of an accountability system is the personnel accountability report (PAR). A PAR is an organized on-scene roll call in which each supervisor reports the status of his crew when requested by the IC or emergency dispatcher.2 The use of an accountability system is recommended by NFPA 1500 Standard on Fire Department Occupational Safety and Health Program9 and NFPA 1561 Standard on Emergency Services Incident Management System.10 A functional personnel accountability system requires the following:

  • development of a departmental SOP
  • training all personnel
  • strict enforcement during emergency incidents

As the incident escalates, additional staffing and resources may be needed, adding to the burden of tracking personnel. An incident command board should be established at this point with an assigned accountability officer or aide. As a fire escalates and additional fire companies respond, a chief’s aide or accountability officer assists the incident commander with accounting for all fire fighting companies at the fire, at the staging area, and at the rehabilitation area. With an accountability system in place, the incident commander may readily identify the location and time of all fire fighters on the fireground. A properly initiated and enforced accountability system that is consistently integrated into fireground command and control enhances fire fighter safety and survival by helping to ensure a more timely and successful identification and rescue of a disoriented or downed fire fighter. This department has developed and implemented SOPs governing accountability and even assigns an accountability officer to the IC to assist with radio transmissions and PARs.

An accountability officer was assigned to assist the IC during the incident. A PAR was immediately obtained following the rescue attempts for Victim #1. Victim #1 was identified as “missing,” but Victim #2 was incorrectly identified as “accounted for.” Victim #2 was incorrectly “accounted for” during a second separate PAR. Prior to a third PAR, 50 minutes following the floor collapse, Victim #2 could not be visibly accounted for on the fireground and his whereabouts were unknown. Officers need to visually account for their members prior to providing an “all accounted for” to the IC or accountability officer. Quickly being able to account for all personnel at an incident is paramount and can determine how an IC orders search and rescue efforts or other suppression activities.

Recommendation #5: Fire departments should ensure that a separate incident safety officer, independent from the incident commander, is appointed at each structure fire.

Discussion: According to NFPA 1561 Standard on Emergency Services Incident Management System, 11 “The incident commander shall have overall authority for management of the incident and the incident commander shall ensure that adequate safety measures are in place.” This shall include overall responsibility for the safety and health of all personnel and for other persons operating within the incident management system. While the incident commander is in overall command at the scene, certain functions must be delegated to ensure adequate scene management is accomplished. 10 According to NFPA 1500 Standard on Fire Department Occupational Safety and Health Program, 9 “as incidents escalate in size and complexity, the incident commander shall divide the incident into tactical-level management units and assign an incident safety officer (ISO) to assess the incident scene for hazards or potential hazards.” These standards indicate that the incident commander is in overall command at the scene but acknowledge that oversight of all operations is difficult. On-scene fire fighter health and safety is best preserved by delegating the function of safety and health oversight to the ISO. Additionally, the incident commander relies upon fire fighters and the ISO to relay feedback on fireground conditions in order to make timely, informed decisions regarding risk versus gain and offensive-versus-defensive operations. The safety of all personnel on the fireground is directly impacted by clear, concise, and timely communications among mutual aid fire departments, sector command, the ISO, and the incident commander. NFPA 1521 Standard for Fire Department Safety Officer defines the role of the ISO at an incident scene and identifies duties such as recon of the fireground and reporting pertinent information back to the incident commander; ensuring the department’s accountability system is in place and operational; monitoring radio transmissions and identifying barriers to effective communications; and ensuring established safety zones, collapse zones, hot zones, and other designated hazard areas are communicated to all members on scene.11 Larger fire departments may assign one or more full-time staff officers as safety officers who respond to working fires. In smaller departments, every officer should be prepared to function as the ISO when assigned by the incident commander. The presence of a safety officer does not diminish the responsibility of individual fire fighters and fire officers for their own safety and the safety of others. The ISO adds a higher level of attention and expertise to help the fire fighters and fire officers. The ISO must have particular expertise in analyzing safety hazards and must know the particular uses and limitations of protective equipment. 4

During this incident, the designated department ISO was not dispatched until the incident was upgraded to a 2nd alarm because it occurred after the normal duty shift of the ISO. The ISO did not arrive until rescue/recovery operations had begun on breaching the Side 4 wall. The presence of an ISO throughout this incident would have allowed the IC to focus on supervising the incident while the ISO directed safety operations.

Recommendation #6: Fire departments should ensure that fire fighters use their self-contained breathing apparatus (SCBA) and are trained in SCBA emergency procedures.

Discussion: Fire fighters are tasked at times to operate within environments which pose inhalation hazards (e.g., toxic smoke and oxygen deficiency12), defined by OSHA as immediately dangerous to life and health (IDLH). Proper training along with an implemented and enforced policy or procedure will assist fire fighters with proper maintenance, use, and removal of a SCBA. OSHA 29 CFR 1910.134 (g)(4)(iii) states, “all employees engaged in interior structural firefighting use SCBAs.”13 During this incident, the medical examiner stated both victims died from inhalation of products of combustion. The medical examiner also indicated that the victims’ COHb levels (a measure of carbon monoxide in the bloodstream) were over 50%. Even if nothing but carbon dioxide, water vapor, and nitrogen were present in the fire products and these were to mix with the air being breathed by a fire fighter, then the oxygen percentage would be reduced below the normal 21%. At 15% oxygen, fire fighters can experience lethargy, poor coordination, and confused thinking. The two principal toxins in smoke—carbon monoxide and hydrogen cyanide—act to deprive the brain of oxygen, and their effects would be enhanced due to the lower levels of oxygen in the air.14 Both victims were discovered without their facepieces on.

Due to the smoke conditions, both victims would have had to have been on air when entering the structure. It has not been determined why both victims were found without their facepieces on, but NIOSH investigators have theorized the following possibilities:

  • Victim #1 removed his facepiece to transmit his “Mayday.”
  • Both victims’ facepieces were unintentionally knocked off when falling into the basement.
  • The facepieces were removed because they ran out-of-air or other emergency situation.

Emergencies created by, or associated with, SCBAs can be overcome in several ways. Fire departments can develop and implement a comprehensive respiratory protection program15 that includes fire fighter fitness, training, competency, and skill in SCBA and emergency procedures. Firefighters should remember the first rule in any emergency situation, and that is not to panic. Panic causes increased breathing air consumption and inability to focus on emergency procedures. If fire fighters become lost, trapped, or disoriented they need to focus on managing remaining air in their SCBA cylinder until other fire fighters can make a rescue attempt. Removing one’s facepiece in an IDLH atmosphere can immediately expose the respiratory system to a potentially fatal environment, thus incapacitating an individual. Choosing to leave one’s SCBA facepiece on may be the best chance in providing additional time for a fire fighter to be rescued. Fire fighters should follow their department’s SOPs regarding emergency SCBA procedures and emergency communications.

Recommendation #7: Manufacturers, equipment designers, and researchers should conduct research into refining existing and developing new technologies to track the movement of fire fighters inside structures.

Discussion: Fire fighter fatalities often are the result of fire fighters becoming lost or disoriented on the fireground. The use of systems for locating lost or disoriented fire fighters could be instrumental in reducing the number of fire fighter deaths on the fireground. The National Institute of Standards and Technology (NIST) has been evaluating the feasibility of real-time fire fighter tracking and locator systems for some time.16, 17 Another group researching advanced fire fighter locator and tracking systems is the Maryland Fire Rescue Institute, located at the University of Maryland – College Park.18 Research into refining existing systems and developing new technologies for tracking the movement of fire fighters on the fireground should continue. While it is not clear that the use of this technology in this incident would have prevented the fatalities, such technology could potentially have reduced the search time by aiding rescue teams in pin-pointing the location of the missing fire fighters. This new technology must function properly in the severe fire conditions often encountered during rescue operations.

During the initial stages of the incident, it was not known who was transmitting the Mayday, where exactly they were in the basement, or how they got into the basement. Victim #2 went accounted for approximately 50 minutes before a determination was made that Victim #2 was also missing. It was not until rescue/recovery crews visually located the victims that they accounted for the location of Victim #2. This technology may have assisted the fire department during this incident in more quickly locating Victim #1 and Victim #2.

Of importance, Victim #1’s PASS device was alarming during the Mayday and when he was discovered, but it was reported to NIOSH investigators that Victim #2’s PASS device was never heard. Victim #2’s PASS device was evaluated as part of NIOSH’S NPPTL SCBA inspection. Victim #2’s PASS device failed to function when tested, but after the batteries were replaced within the PASS device, it alarmed appropriately. It has not been determined if the battery life was exhausted prior to Victim #2 going into the structure. It is important to note that the 2007 revision to NFPA 1982 Standard on Personal Alert Safety Systems (PASS) includes new heat and flame resistance requirements resulting from documented reports where PASS devices were not heard during fatal fireground incidents. 19 Laboratory testing conducted by NIST determined that exposure to high temperature environments caused the loudness of the tested PASS alarm signal to be reduced. This reduction in loudness can cause the alarm signal to become indistinguishable from background noise at an emergency scene. Initial laboratory testing by NIST highlighted that this sound reduction may begin to occur at temperatures as low as 300°F. Thus the use of PASS devices meeting NFPA 1982, 2007 Edition requirements is highly recommended.

Recommendation #8: Manufacturers, equipment designers, and researchers should continue to develop and refine durable, easy-to-use radio systems to enhance verbal and radio communication in conjunction with properly worn self-contained breathing apparatus (SCBA).

Discussion: The use of Personal Protective Equipment (PPE) and an SCBA make it difficult to communicate, with or without a radio.20-22 Faced with the difficult task of communicating while wearing a SCBA, fire fighters sometimes momentarily remove their facepieces to transmit a message directly or over a portable radio. Considering the toxic and oxygen-deficient hazards posed by a fire and the resulting products of combustion, removing the SCBA facepiece, even briefly, is a dangerous practice that should be prohibited. Even small exposures to carbon monoxide and other toxic agents present during a fire can affect judgment and decision-making abilities. To facilitate communication, equipment manufacturers have designed facepiece-integrated microphones, intercom systems, throat mikes, and bone conduction mikes worn in the ear or on the forehead.20-22

During this incident, interviewed fire fighters complained of radio transmissions being unintelligible at times or not heard at all. Although NIOSH investigators are not certain why Victim #1 and Victim #2 were found without their facepieces on, one theory is that Victim #1 may have momentarily removed his facepiece to better transmit his Mayday. Fire fighters recall hearing his transmissions as they came across the radio and also emanating clearly from the structure.

Recent testing by the National Institute for Standards and Technology (NIST) of portable radios in simulated fire fighting environments has identified that radios are vulnerable to exposures to elevated temperatures. Some degradation of radio performance was measured at elevated temperatures ranging from 100°C to 260°C, with the radios returning to normal function after cooling down. Additional research is needed in this area.16, 20 Fire service radios also need to be waterproof as normal fireground conditions dictate that radios are frequently exposed to excessive amounts of water during routine use through exposure to hose streams, overspray, water dripping from overhead, etc.

Other Links;

 

FDNY- August 27, 2006 Walton and East Mount Eden Avenues, Bronx, NY

Floor Collapse at Commercial Structure Fire Claims the Lives of One Career Lieutenant and One Career Fire Fighter – New York (REPORT HERE)

SUMMARY
On August 27, 2006, a 43-year-old male career Lieutenant (victim #1) and a 25-year-old male fire fighter (victim #2) died after the floor they were operating on collapsed at a commercial structure fire. At approximately 1230 hours, crews were dispatched to a fire. The victims’ engine was dispatched at 1236 hours as an additional unit alarm and arrived on the scene at approximately 1240 hours. At approximately 1251 hours, victim #1, victim #2 and fire fighter #1 advanced a 2 ½-inch hand line through the front of the structure and down an aisle toward the rear of the store. The fire was located in the rear interior of the structure (discount store) that sold a variety of numerous small household commodity items. Approximately three minutes later, the structural members supporting the floor directly below the victims failed. The V-shaped collapse of the floor caused victim #1 and victim #2 to fall into the basement and shelving stocked with merchandise to fall in on top of them. Multiple MAYDAYs were transmitted and the fire fighter assist and search team (FAST) was deployed to the front of the structure where they assisted in the rescue of numerous members who had been operating in the interior of the structure at the time of the collapse. Battalion Chief #1, Lieutenant #1 and fire fighter #1 were freed from the debris. At approximately 1415 hours, victim #1 was removed from the debris in the basement and transported to the hospital. He died the next day as a result of his injuries. At approximately 1435 hours, victim #2 was removed from the basement and transported to the hospital where he was pronounced deceased as a result of his injuries.

F2006-27 Aug 27, 2006 Floor collapse at commercial structure fire claims the lives of one career lieutenant and one career fire fighter – New York PDF Adobe PDF file

NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should:

  • consider the possibility of a substandard structure when building information is not available from pre-incident plans
  • consider the live load of water on the structure and go defensive when water load potentially compromises the structural integrity

Additionally, municipalities should:

  • explore means of coordinating information sharing between building and fire departments to increase safety for fire fighters and civilians
  • consider conducting inspections on all commercial structures where a change of occupancy has occurred or renovations are known or suspected, giving special attention to non-sprinklered commercial retail structures

RECOMMENDATIONS/DISCUSSIONS

Recommendation #1: Fire departments should consider the possibility of a substandard structure when building information is not available from pre-incident plans, and implement a defensive strategy when no occupants are at risk.

Discussion: The threat of a collapse of some type (i.e. roof, ceiling, floor or wall) is a possibility in any structural fire due to the effects of fire, water application, age, insects, and alterations. It is a high probability that a fire department is unaware of structural defects caused by age, insects and alterations. To minimize the risk of injury or death to fire fighters during structural operations, the size-up and risk assessment includes many factors, which include: age of the building (deterioration of structural members, evidence of weathering, use of lightweight materials in new construction), occupancy, and renovations or modifications to the building.3,4,5

Pre-incident plans are an effective tool in preventing injuries and deaths of fire fighters due to structural collapse.  They allow fire departments to determine factors, such as, age of the structure, structural integrity, type of materials used in the structure, and amount of load on the roof that could weaken the supports, etc.  However, in numerous cities and towns where buildings number in the hundreds of thousands, fire departments lack the manpower to pre-plan all buildings under their protection. Often fire departments are limited to targeting buildings that have a unique construction or pose a known hazard.

In floor collapses that have occurred, such as those at a New York City drug store (October 17, 1966) and at a Boston hotel (June 17, 1972), there were no warning signs, and no time to act and withdraw fire fighters to safety. At both of these floor collapses, unauthorized alterations on the structure contributed to the structural failure.5

“The potential for structural collapse is one of the most difficult factors to predict during initial size-up and ongoing fire fighting. Structural collapse usually occurs without warning.” 3 When pre-incident plan information on the fire structure is not available, occupants have been evacuated, and evidence of structural deterioration and/or modification cannot be determined, a defensive strategy should be implemented. A defensive strategy would help ensure fire fighter safety and is warranted in structures that lack pre-incident plans, no occupants are at risk, and where the potential for numerous unrecognized hazards exists, such as substandard construction and building deterioration.

Fire departments operating in older businesses and homes should be suspicious of potential alterations and renovations which could result in unsupported loads and unusual voids. These alterations may be hidden by sheetrock (drywall) or flooring and built up flooring which is difficult to detect during inspections and virtually impossible to detect during firefighting operations. The older the structure, the greater the possibility of renovation or remodel.

In this case, there were no current pre-incident plans for the structure; the occupants had evacuated upon the fire department’s arrival, and compromised structural integrity was not immediately evident. Structural alterations had been made to the girders, columns, and floor in order to presumably level and support the floor. A post incident inspection showed 2 x 4 boards being used inappropriately (in orientation and stability) as a floor joist. A cluster of nails were used in lieu of bolts to attach gusset plates to the columns and girders. Sheets of plywood were added to the floor with no structural support around the sheet’s edges nor at 12”, 16” or even 24” intervals in accordance with standard building codes. Subflooring (i.e., plywood, wafer board, etc.) needs to be fastened around the sheet’s edges and at interval spacing (generally every 16 inches, but spacing may vary according to load requirements) to support floor joists. The interior support members of the structure suffered from severe rot at the base of the timber columns.

Recommendation #2 : Fire departments should consider the live load of water on the structure and go defensive when water load potentially compromises the structural integrity.

Discussion: A forensic engineering analysis of the fire building demonstrated that the weight of water added to the building from the fire fighting operations was approximately 50% of the rated structural capacity of the floor.2 As noted previously, however, timbers that supported the ground floor had rotted. Thus, the actual structural capacity of the floor was less than rated. Although the ultimate cause of the collapse was the rotted timbers, the weight of the water applied during the fire fighting operations, in addition to the weight of fire fighters, store merchandise, etc., likely contributed to the collapse. Given the many unknowns during fire fighting operations, including in most incidents the rated capacity of floors, incident commanders need to continuously consider the impact of water weight on structural integrity, and shift to defensive strategies when structural integrity is potentially compromised.

Firefighting operations can drastically increase the live load on the fire building. This can be due to the weight of:

  1. the firefighters with their protective equipment and tools,
  2. the hose-line brought into the fire building, and
  3. the water used to attack the fire6.

A 2 ½ -inch hose-line can deliver approximately 250 gallons of water per minute. 5 This adds about 2,082 pounds per minute into the fire building. If multiple hose-lines are operating, the weight of the water can be tremendous.

When operating in an offensive mode, a buildup of water within a building requires that immediate action be taken to alleviate these conditions. 6 The remedy may be as simple as controlling the excess flow from the hose-line or moving fire debris that is restricting runoff. When using large amounts of water, it is always advisable to provide for drainage when necessary. This can be accomplished any number of ways from chutes with traps to actual holes drilled to provide relief. 6

It must be recognized that at the same time that this additional weight is being introduced into the fire building, the fire and water are weakening the structure. Under these conditions, a defensive strategy is best when no civilians are in the structure. 5

In this case, civilians had evacuated the fire building upon the fire department’s arrival. The structures’ configuration only enabled an initial attack through the front of the structure and down narrow aisle ways to the rear of the structure where the origin of the fire was located. Prior to the collapse, three 2 ½-inch hose-lines (operating 17 minutes, 8 minutes, and 2 minutes, respectively) were flowing water through and into the rear of the structure. The added weight and flow of the water could have contributed to the floor collapse because of the rotted support columns decreasing the timber frame system’s ability to equalize the water load across the floor.

location of victims
Diagram 2. Shows location of victims on the structure’s floor above the girder that failed. From the NIOSH REPORT

 

Additionally,

Recommendation #3 : Municipalities should explore means of coordinating information sharing between building and fire departments to increase safety for fire fighters and civilians

Discussion: Information on building construction, renovations, and alterations can help Incident Commanders develop strategies and tactics that effectively fight fires while attending to fire fighter safety. Pre-incident plans are a useful tool for ensuring that fire departments and Incident Commanders have information on building construction and contents to guide decision-making on the fireground. In urban areas with large numbers of existing structures, it may not be feasible to develop pre-incident plans for all or most structures, and for fire departments to regularly revisit structures to update pre-incident plans. Municipal building departments that issue building permits and conduct code inspections may collect, or be in position to collect, information that may be useful to fire departments. Municipalities should consider exploring mechanisms by which building information relevant to fire fighter and civilian safety can be collected and shared between building and fire departments. As one example, building departments could notify fire departments when building permits are issued. This would result in fire departments being aware of these building alterations, and to possibly target these buildings for a pre-incident plan. Priority should be given to sharing such information for targeted hazards identified by fire departments.

Recommendation #4: Municipalities should consider conducting inspections on all commercial structures where a change of occupancy has occurred or renovations are known or suspected, giving special attention to non-sprinklered commercial retail structures

Discussion: Occupancy changes understandably occur with great frequency. However, every effort should be made as new permits are issued to aggressively inspect any occupancy change. It is critical that municipalities assess that any renovations or remodeling meets current codes, and that original and renovated supports are capable of supporting the new occupancies. These building inspections should specifically consider the loading or redistribution of stock to ensure that flooring can handle dead and live loads.

Other Links;

Fire/EMS Safety, Health and Survival Week 2011: Day Five: Near-Misses, Maydays and Floor Collapses

1 comment

Do you know what's underneath you as you're making entry?

During the last quarter of 2010 and leading well into the second quarter of 2011 there has been a significant emerging trend developing in basement fires, compromised floor systems and assemblies leading to collapse and numerous near-miss events, close calls and unfortunatly, line of duty deaths during fire operations.

If you’ve been paying attention to the various news and on the job reports these past number of months, you may have noticed the increasing numbers of emerging trend evident in near miss, close-calls resulting in maydays, RIT deployments and self-rescue resulting from floor compromise and floor collapse. The double line of duty deaths of two San Francisco (CA) Fire fighers while operating in a Terraced (Hillside construction) residential occupancy while operating below the base level diaphragm (upper street level access). (HERE)

In December 2010,  I was doing some research and posting links related to the first one or two events on Buildingsonfire on Facebook, HERE, it became evident at the time that there was an immediate opportunity to get some learning’s and insights out. If you have a chance head over to Facebook and link into Buildingsonfire and check out the incident links posted as well as some immediate report links. (Demember 2010 time frame)

In a coincidential posting on July 28, 2010, I posted on CommandSafety.com an interesting incident that I came across while preparing for a new post related to a near-miss event that occured in which a Camp Taylor (KY) firefighter survived a floor collapse that momentarily trapped him proximal to the seat of a working basement fire. Camp Taylor (FD) Captain Michael Long sustained second and third degree leg burns after falling through the floor of the burning home and subsequently being rescue by other fire department personnel after calling a mayday.

This event has all the ingrediants the the 2011 Safety Week focus on Surviving the Fire Ground and managing the Mayday. Little did I know that later, in February 2011, while participating in the National FireFighter Near-Miss Reporting System Stakeholders meeting in California, would I have the chance to hear Captain Long’s story first hand, and then also have the opportunity to have him as a guest, sharing his story live on the Taking it to the Streets Radio program in February. (HERE)

Camp Taylor (FD) Captain Michael Long’s near-miss and story of survival resonates with this year’s theme of  Surviving the Fire Ground- Firefighter, Fire Officer and Command Preparedness and Managing the Mayday and provides an opportunity to focus on the event in this, Day Five of the 2011 Fire/EMS Safety, Health and Surival Week activities. The details of Captain Long’s story can be found on the National FireFighter Near Miss Reporting System web site (HERE) as well as in the June 2011 issue of Fire Engineering Magazine titled, Floor Collapse: A Survivors Story. Let me state upfront also the Captain Michael Long will be presenting the accounts of his near miss event and the lessons-learned at IAFC Fire-Rescue International Conference in Atlanta in August (HERE).

 On July 25, 2010, Captain Michael Long of the Camp Taylor (Ky.) Fire Protection District fell through the floor of a house during a four-alarm fire and suffered severe burn injuries. On Aug. 30, 2010, Capt. Long submitted a near-miss report based on this event. The National Fire Fighter Near-Miss Reporting System is an anonymous and confidential reporting system; however, Capt. Long wanted to have his name associated with this report so that others would understand the value of sharing near-miss events. What follows is an excerpt from his report and excerpts from a recent phone interview. To read his full report, including an extensive lessons learned section, search by report number for report #10-1072 on the Search Reports page of www.firefighternearmiss.com.

  

Near Miss Report Event #2010-1072

  

 “I made sure my crew was ready to enter, sounded the floor for stability and then crossedover the threshold, entering the structure. When I was approximately 5 feet inside the structure, I felt the floor start to give way. I turned toward the front door to try to bail out, and at the same time yelled at others to get out, when the floor system collapsed. This was no ordinary collapse. More than two-thirds of the first floor collapsed simultaneously. The living room, dining room, kitchen, bathroom and foyer all fell at once. “When the collapse happened, I was the only one who fell into the basement, right into the heart of the fire. All I could see around me were flames.

I could not see the hole that I had fallen through. I could not see my fellow firefighters above me. All I could see was fire. I began to try to find something to use to climb back up with. Since I did not know what type of collapse had occurred, I just started clawing away at anything as I was trying to climb. During this time, my legs were burning.

Fire was burning up between my boots and my bunker pants. The pain was intense. My deputy chief was trying to put a line on me for protection, but the fire was extremely intense. He was lying on the porch with fire shooting out over his head. He stated he could occasionally see the top of my helmet and the reflective stripes on my coat sleeves.

By a bit of luck, a roof ladder was laying in the front yard that had just been taken off the roof after the completion of a ventilation operation.

My deputy chief directed the crew to put the ladder into the hole for my escape. “By this time, I was burned on my legs and struggling with exhaustion and the intense heat. I was screaming both from pain and due to fear. I could hear screaming coming from above, butwas unable to make out the majority of it. I finally heard the word “ladder” and then felt something across my back. Once they got the ladder into the basement, I had to get around to it. I still could not see anything but fire, so this was all by feel. As I started up the ladder, I got two rungs up, reached for the third rung, and lost my grip and fell back into the basement landing on my back. I was so exhausted that I started making my peace with God that this was where I was going to die.

For the full excerpt from Captain Long’s near miss report go to the NFF Near Miss Reporting Site and Resource Link, HERE

  

Captain Long

Incident Lessons Learned from Captain Long:

  • Train as if it is real. Train, train, train, and then train some more. Take advantage of every opportunity to train. The better we are trained, the less our chance of injury. The training must be physically and mentally. Crews must focus on more hands-on scenario-based training that allows for problem solving. If crews are taught that the outcome to every scenario is static, they are not being encouraged to think. Every run is different; no single solution applies to every situation. Adaptations or decisions that are not in step with changing conditions can actually be disadvantageous. We must make the right decisions based on the correct interpretation of the environment and blend those observations with our knowledge, skills, and abilities to map a course of action that will lead us to a successful outcome. Read reality and come up with the best possible plan. In my situation, quick thinking and adapting to the problem that presented itself saved my life.
  • Mutual-aid training is a must. We must train more with our neighboring departments to improve operations. It is occasionally difficult to work in situations where you do not really know with whom you will be working or where the command structure and tactics differ from those of your department. We all learn from the same book; however, the interpretations and tactics differ from person to person and department to department. I am not saying anyone is right or wrong in the way they do things—we all just need to do a better job of understanding that there is more than one way to get the job done.
    We cannot know exactly how everyone on an emergency scene will perform because each person has a different interpretation of his surroundings and role in the system. Standard operating guidelines (SOGs) can assist in this area, but SOGs rely on perceptions and interpretations by individuals to be implemented as intended. Accidents often happen because everyone has a unique perspective on the environment, and each makes different decisions based on their perception.
    We must perceive the environment correctly to ensure we make the right move. If these actions are not communicated and coordinated in the intricate system that is the fireground, accidents will be the inevitable and regrettable results. Training and frequent reviewing of SOGs are vital to our safety.
  • Risk assessment. Sounding the floor prior to entry is not always a good indicator of the floor’s stability. Less than two minutes before I made entry, there were three other firefighters, at least the same weight as I, in the same area where the collapse occurred. Everything changed in a very short time. There was no warning. Adkins told me at the hospital that all he heard was a “whoosh” sound when the floor collapsed. Then I disappeared. Within two minutes, the floor assembly went from being able to sustain a live load of at least 900 pounds in that area (accounting for gear, equipment, SCBA, and so on) to collapsing with about a 300-pound load, and I was close to a load-bearing wall. A good way to evaluate risk vs. gain is to get the most accurate report on burn time as possible to help determine structural integrity.
  • Rapid intervention. RIT is a critical fireground benchmark and is very important for safety, but it would have been ineffective in this situation. Had my crew not reacted the way they did immediately, I would not have been able to last long enough to wait for the RIT. In the time it would have taken for the RIT to gear up, come up with a plan, and enter, I would have died. The stars aligned in my favor that night. The person calling the Mayday or a nearby crew often mitigates personnel emergencies. My crew was able to act decisively at the correct time, and I am alive because of it. It is important to remember that a large percentage of Maydays are mitigated by the crew to which the lost firefighter is assigned or a nearby crew. RIT deployments account for a small number of rescues; we must always be alert and ready for the “incident within the incident.”
  • Manage your emotional response. From a personal standpoint, you must rely on your training and try not to panic. Know your equipment and procedures well. I did panic, but I was still able to keep myself together enough to know not to leave the area since I had been told that the stairs had burned away. Keeping my SCBA on, resisting the emotional reaction to remove my mask because of claustrophobia, was a huge factor in my survival. If I had tried to find another way out, my crew could not have gotten to me with the ladder. Had I removed my mask, the story would have ended quite differently. When I teach, I try to train as if it is the real thing. Never take a run for granted. Always expect the worst; you will be better prepared to deal with the unexpected.
    If we continually study accident reports and learn from them, the likelihood of being surprised will be diminished. Peter Leschak writes in Ghosts of the Fireground: ”In fire and other emergency operations, you must not only tolerate uncertainty; you must savor it, or you won’t last long. The most efficient preparation is a general mental, physical, and professional readiness nurtured over years of training and experience. You live to live. Preparing is itself an activity, and action is preparation.”
  • Talk about it. Critical incident stress debriefing (CISD) is important for ensuring that personnel from all departments on scene are taken care of emotionally. CISD needs to extend beyond just one or two briefings. Personnel involved in a highly emotional event must be given the opportunity to speak to a trained CISD team member early and be given as much time as is needed to work through their issue. Some firefighters have a macho attitude and try to deal with their emotions on their own, or maybe they don’t deal with them at all. Others self-medicate with alcohol or, worse, these difficult emotional events are allowed to fester with no relief. People should be accepting of those who deal with issues up front and tell their stories. Telling these stories makes us better and helps to keep us safe. This reduces the possibility of “snapping” because you have too much pent-up emotion.
    My fellow firefighters are still affected by this event, even those who were not there. Department personnel must be open-minded and receptive to the fact that emotional events will affect your performance and your personal life and that it is acceptable to be open and deal with them. When difficult emotional situations present themselves, members should attempt to deal with them as soon as possible.
  • Know what is possible and what is not. Know the experience level of your crew. Going into a bad situation with a crew that may not have exposure to a lot of different situations or that you aren’t that familiar with could make operations more difficult. I had everything from a 30-year veteran to a one-year recruit, so the experience level was all across the board. I knew that the situation we were going into was getting worse and required quick action, so I took the lead to ensure that the operation would be completed as quickly as possible. I knew my deputy chief would be watching us to ensure things were proceeding safely. I knew my crew could get the job done; however, this was an operation that is not often practiced and I wanted to make sure it was done correctly. I will not send my crew into an area that I am not comfortable going into. The more you train and the more people you can train with, the better you will understand your capabilities.

 Listen or download the special interview I had with Captain Mike Long as well as

Taking it to the Streets Radio Program and Interview with Capt. Long

 

Taking it to the StreetsTM is a monthly radio show featured on BlogTalk Radio and is hosted by nationally renowned fire service leader Christopher Naum, a  36-year fire service veteran and highly regarded national instructor, author, lecturer and fire officer and  the distinguished leading  national authority on building construction and fire ground operations.  Taking it to the StreetsTM is a Buildingsonfire.com Series and FireFighternetcast.com Production,   © 2011 All Rights Reserved 

Taking it to the Streets: Near Miss Reporting and One Captain’s Close Call

Podcast: Play in new window | Download

The progam was taped from the Live Broadcast on March 16th at 9pm EST

Taking it to the Streets: Near Miss Reporting and One Captain’s Close Call

On Your Street, In Your City, Across the Country, Around the WorldTM

The direct show link is here

The line-up of Program guests included, Lt. Steve Mormino, FDNY (ret), Captain CJ Haberkorn Denver (CO) Fire Department and Special Guest Captain Michael Long, Camp Taylor (KY) Fire Protection District.

Grab a cup of coffee and sit down for a special two part, two hour program with Taking it to the Streets on Firefighernetcast.com where we’ll be discussing the National Near-Miss Reporting System and the untapped resources that the program and system provides with Christopher Naum and this outstanding group of fire service leaders. The second part of the program will dedicated to the personal account of Captain Long’s Close Call event from July 25, 2010 (NMR #10-1072) when a catastrophic floor collapse at a residential occupancy plunged him into a fire involved basement.

Check out the latest downloads of recent programs in the archives by visiting Taking it to the Street’s webpage on Firefighternetcast.com or for program insights at CommandSafety.com.    

  • Firefighternetcast.com HERE
  • Taking it to the Streets Radio Programs, HERE and HERE 
  • Buildingsonfire.com, HERE  

Taking it to the StreetsTM, radio program hosted by highly regarded national instructor, author, lecturer and fire officer Christopher Naum, continues to provide provocative insights and dynamic discussions with leading national fire service leaders and guests on important issues affecting the American Fire Service with applications internationally within the tradition and brotherhood of the Fire Service.

Taking it to the StreetsTM, is a Buildingsonfire.com Series and Firefighter Netcast.com Production, in affiliation with the Command Institute

 

National Fire Fighter Near Miss Reporting System’s Support for the 2011 Safety Week

Don’t forget to go to the National Firefighter Near Miss Reporting System for  number of exceptional training aids, resources, PPT and more. NFFNMRS, HERE

Here are some of the National Firefighter Near Miss Reporting System Produced 2011 Safety Week Products

 
File Title File Size File Description
  • Presentation: Preventing The Mayday
  • 176 KB A powerpoint presentation about situational awareness, planning, size-up, and defensive operations
  • Presentation: Being Ready for the Mayday
  • 176 KB A powerpoint presentation about personal safety equipment, communications, and accountability systems
  • Presentation: Fire Fighter Expectations of Command
  • 176 KB A powerpoint presentation about fire fighter expectations of command.
  • Presentation: Self-Survival Skills
  • 176 KB A powerpoint presentation about self survival skills at a mayday.
  • Presentation: Self-Survival Procedures
  • 176 KB A powerpoint presentation about self survival procedures.
  • Grouped Report: Preventing The Mayday
  • 176 KB A grouped report about situational awareness, planning, size-up, and defensive operations
  • Grouped Report: Self Survival Procedures
  • 176 KB A grouped report about self survival procedures
  • Grouped Report: Being Ready for the Mayday
  • 176 KB A grouped report about personal safety equipment, communications, and accountability systems

    In the meantime here are some links I pulled together that you should take the time to read and share with your companies, personnel and staff…..

    This seems like a good time to have a ten minute drill on these events as Operating Experience (OE) on floor systems and operational safety, calling or commanding the mayday.

     Or take some time to visit the The IAFF Fire Ground Survival Program (FGS)site which has the most comprehensive survival-skills and mayday-prevention program currently available and is open to all members of the fire service. Incorporating federal regulations, proven incident-management best practices and survival techniques from leaders in the field, and real case studies from experienced fire fighters, FGS aims to educate all fire fighters to be prepared if the unfortunate happens.  (Day One: Are you ready, HERE)

    • For links to the IAFF Fire Ground Survival Program, HERE and HERE

    Self-Survival Procedures

    FGS Online Program Chapter 3
    To improve survivability in a Mayday situation, a fire fighter must know how to alert rescuers to his or her location and perform self-survival techniques. Through the study of fire fighter fatalities, NIOSH has identified specific actions fire fighters can take to help save themselves. Variations of this same NIOSH recommendation have appeared in numerous fire fighter fatality reports. These recommendations were used to create a self survival procedure that is easy to remember using a mnemonic (GRAB LIVES). Following these steps increases the likelihood of the rescuers finding and assisting the fire fighter to safety.
    When a fire captain died when trapped by partial roof collapse in a vacant house fire in Texas, NIOSH recommended in report number F2005-09 that trapped fire fighters should:

    • First, transmit a distress signal while they still have the capability and sufficient air.
    • Next, manually activate their PASS device. To conserve air while waiting to be rescued, try to stay calm and avoid unnecessary physical activity.
    • If not in immediate danger, remain in one place to help rescuers locate them.
    • Survey their surroundings to get their bearings and determine potential escape routes.
    • Stay in radio contact with the IC and other rescuers.
    • Attract attention by maximizing the sound of their PASS device (e.g., by pointing it in an open direction); pointing their flashlight toward the ceiling or moving it around; and using a tool to make tapping noises on the floor or wall. 

    Self-Survival Skills

    FGS Online Program Chapter 4

    Disentanglement Maneuvers

    Fires inside an enclosed structure create a mess for fire fighters operating on the floor. Fire fighters often encounter debris that has fallen off shelves, and ceiling and wall fixtures that have burned and are left hanging to the floor. These hazards, coupled with the mess a fire fighter creates when searching for victims in smoky environments, can create egress problems for a fire fighter.

    As fire burns draperies, blinds, lighting fixtures, computer wiring, and HVAC ducting, the possibility of encountering an entanglement hazard increases. The overhead ducting of the HVAC system contains wires that give the ducting its stability.

    If a fire breaches the ceiling and burns the ducting, the wires within the ducting fall to the floor. These wires can cause a dangerous entanglement hazard to fire fighters operating on the floor. Fire fighters must anticipate these hazards and have a plan to follow when egress is cut off.

    NIOSH Alert: Preventing Injuries and Deaths of Fire Fighters

    Fire Fighter Expectations of Command

    FGS Online Program Chapter 5
    A discussion of what command must communicate to the distressed fire fighter, dispatch, the RIT group supervisor and all others assigned to the incident to assure a successful rescue.

    Here are Some Mission Critical Reference Links for Operational Insights and Operating Experience (OE) to support Your Training and Operational Needs not only this week, but through the entire year.

     

    Here are some Safety Considerations related to Residential Occupancies (non-inclusive) for Operations at Basement Fires that will support fireground operational safety:

    • Conduct a thorough fire size-up and communicate the findings to all personnel on-scene before entering the building.
    • Conduct an assessment of the Building Profile ( building construction type, structural assembly systems and features and age) and assesss fire behavior and intensity levels.
    • Ensure an adequte Risk Assessement is conducted and that Risk versus Gain is determined
    • Maintain situational awareness throughout the tactical deployment of crews within the interior of the structure
    • Conduct a 360 degree perimeter assesement when feasible to determine access and egress points, fire location and travel and other mission critical operational perameters.
    • Incident commanders and company officers should be trained and experienced in structure fire size up to avoid putting fire fighters at unneeded risk of working above fire-damaged floors.
    • Do not enter a structure, room, or area when fire is suspected to be directly beneath the floor or area where fire fighters would be operating, or if the location of the fire is unknown.
    • Never assume structural safety of any floor (regardless of the construction) having a significant fire under it.
    • Conduct pre-incident planning inspections during the construction phase to identify the type of floor construction.
    • If pre-planning is not conducted, assume residential construction and small commercial buildings built since the early 1990s may contain engineered wood I-joists.
    • Report construction deficiencies noted during preplanning to local building code officials. For example, engineered wood floor joists should only be modified per manufacturer specifications—usually limited to cutting to length and removing pre–cut knockouts for utility access. Report damaged or cut chords or webs to building officials.
    • Develop, enforce, and follow standard operating procedures (SOPs) on how to size up and combat fires safely in buildings of all construction types. Rapid intervention teams (RIT) should include a portable ladder with their RIT equipment when deployed at basement fires.
    • Ensure Time Compression is considered: Ensure Command has the ability to monitor progress or elapsed incident time and adjusts strategic and tactical plans accordingly and in a time effective manner. 
    • Provide training on identifying signs of weakened floor systems (soft or spongy feel, heat transmitted through floor, downward bowing, etc.).
    • Make fire fighters aware that all floor types can fail with little or no warning.
    • Use a thermal imaging camera to help locate fires burning below or within floor systems, but recognize that the camera cannot be relied upon to assess the strength or safety of the floor. (Refer to the recent UL Test Data and Operational Safety Considerations ”Structural Stability of Engineered Lumber in Fire Conditions” available at http://www.uluniversity.us/ )
    • Fire fighters should be trained on the use of thermal imaging cameras, including limitations and difficulties in detecting fire burning below floor systems. (See reference to UL above)
    • Immediately evacuate and, if possible, use alternate exit routes when floor systems directly beneath the floor where fire fighters would be operating are weakened by fire.
    • Use defensive overhaul procedures after fire extinguishment in structures containing fire-damaged floor systems of all types.
    • Consider becoming active in the building code process and influence requirements for fire resistance of floor and ceiling systems to further fire fighter safety and health.
    • Ensure RIT personnel area staged and have complete a site assessment of the building and occupany upon thier arrival and set-up
    • Ensure that a rapid intervention team (RIT) is on the scene as part of the first alarm and in position to provide immediate assistance prior to crews entering a hazardous environment

    Here’s some screen shots from Buildingsonfire on Facebook. Go HERE or follow the link at the left column. Join the growing list of over 3900 fans with Buildingsonfire on Facebook and Buildingsonfire.com

    Stairway Collapse and Mayday in Chicagoland

    No comments

                                                     

    A fire in single family residential occupancy in Chicago’s West Humboldt Park section on May 29th produced these dramatic occurrences: Serious injury to a woman and her grandchild, a firefighter being trapped, and good Samaritans lending a hand.

    About 12:30 a.m., Chicago fire officials and police responded to a fire in a one-and-a-half story single family home in the 4200 block of West Hadden Avenue on the West Side, according to police and fire officials. A 2-11 Alarm and EMS Plan 1 were called for the fire, said Fire Media Affairs spokesman Chief Joe Roccasalva. The fire was located in a 1 1/2 story wood frame bungalow (SFR) dwelling.  According to published reports, the firefighter fell through a burning stairwell when it collapsed and was briefly trapped. He was quickly located and extricated with minor injuries following the mayday alert

    4246 West Hadden Ave

    Aerial

     

    Chicago Sun-Times, HERE and Breaking News Report, HERE and ABC News7 TV, HERE

    Typical Circa Stairway Construction

     

    Don’t forget to check out the 2011 Safety and Survival Week focus on;

    2011 Focus: Surviving the Fire Ground – Fire Fighter, Fire Officer & Command Preparedness, HERE

     

    Albuquerque Fire Department; Learnings from Close Call Collapse and Fire Fighter Injuries

    No comments

    The Albuquerque Fire Department seeks to improve operations from past performance

    Four firefighters with the Albuquerque (NM) Fire Department were injured during operations at a three-alarm fire that injured raged through the Royal Crown Apartment Complex  in southeast Albuquerque on Friday February 4, 2011.

    The injured firefighters were among four who fell through the floor from the second story to the first while searching for residents of the, according to the Albuquerque Fire Department. Both suffered leg injuries, one had minor burn, and they were treated and released from University of New Mexico Hospital a few hours later, an AFD spokesperson said.

    According to published reports at the time of the event, the first alarm came in at 3 p.m. bringing personnel and apparatus to the three-story building at 4801 Gibson SE. First units on the scene reported heavy smoke and flames on the north side of the building.

    A crew from AFD Engine 13 entered the building and during a search rescued two uninjured residents from one apartment and also save a cat.

    At 3:40 p.m. Incident command transitioned to a defense operations to fight the fire from outside the building. The third alarm was transmitted due to the projected heavy fuel load in the large complex.

    Overall 75 fire personnel responded and operated at the alarm.

    The fire is believed to have started behind a washing machine in the first-floor laundry room. An electric cause is suspected, but AFD said the exact cause is still under investigation.

    The three-story multiple occupancy apartment complex was built in 1976 and housed 47 apartment units in 31,896 square feet of space.

    In the months since the fire, the Albuquerque Fire Department has conducted a critique and post incident assessment of the operations, mayday and close-calls and overall performance of the department. As reported in the media video leading into this article, the department has taken the results of that post incident assessment and has developed training being delivered to al personnel to increase future operational performance, efficiencies and to reduce the likely hood of a similar event from occurring.

    According to the Fire Department, they were playing catch-up from the early advancing stages of the incident and experienced difficulty in being able to make strategic strides to get ahead of the escalating incident severity, magnitude and rapid development.

    The unexpected events leading to the multiple maydays and firefighter injuries challenged incident command and operations and could have resulted in possible multiple firefighter LODDs versus the close-call, near-miss events that subsequently lead towards the efforts to undertake  critical review of the incident and operations.

    Some Insights and Learning’s from the Incident included that have resulted in enhancements;

    • Communications
    • Situational Awareness
    • Calling the Mayday
    • Radio Communications
    • Distractions and Error Prevention
    • Accountability
    • Command Response to Mayday Events
    • Communications Mayday Alerts

    It is imperative that all departments initiate at the least a formal or informal post incident critique or review. This may be at the company or station level or escalated to a more formal department level assessment and review based upon the incident parameters and conditions.

    The initiation and development of post incident analysis or assessment can be more involving and complex, with the commitment of personnel, resources and time but the benefits derived from such a review will contribute highly to the continued development and improvement of any organization. 

    There are a number of recent after action, post incident or assessments reports that have been published and have been reviewed and discussed here on CommandSafety.com.

    Take the time to review your incidents and runs at the company, station or battalion level. These reviews will identify and address low threshold, latent or emerging conditions before they escalate into apparent or root cause conditions that may contribute to significant adverse events and incidents.

    The Albuquerque (NM) Fire Department’s self-critical review of this event has identified short comings at a number of levels that they are working to improve.

    As they state in the video report, the outcome of this event could have been a lot worse than the injuries sustained and the resultant near-misses. The focus on improvements and enhancements within the functional areas of Calling the Mayday, Rapid Intervention and Mayday Communications and Operations is commendable and aligns with this year’s theme for Safety, Health and Survival Week.

    The 2011 Safety Week theme is; Surviving the Fire Ground – Fire Fighter, Fire Officer and Command Preparedness.

    • Previous Safety Week announcement and details; HERE.
    • We’ll post under a separate article details on the IAFF Fire Ground Survival Program soon.

    Albuquerque (NM) Fire Department’s Web Site, HERE

    This year’s Safety Week will focus on delivering the online IAFF Fire Ground Survival (FGS) awareness training course to all fire departments. The program is the most comprehensive survival skills and MAYDAY prevention program currently available and is open to all members of the fire service. Additional planning tools and resources will be available on the Safety Week website.

    The IAFF Fire Ground Survival Program (FGS) is the most comprehensive survival-skills and mayday-prevention program currently available and is open to all members of the fire service. Incorporating federal regulations, proven incident-management best practices and survival techniques from leaders in the field, and real case studies from experienced fire fighters, FGS aims to educate all fire fighters to be prepared if the unfortunate happens.

    For links to the IAFF Fire Ground Survival Program, HERE and HERE

    The program will provide participating fire departments with the skills they need to improve situational awareness and prevent a mayday. Topics covered include:

    • Preventing the Mayday: situational awareness, planning, size up, air management, fitness for survival, defensive operations.
    • Being Ready for the Mayday: personal safety equipment, communications, accountability systems.
    • Self-Survival Procedures: avoiding panic, mnemonic learning aid “GRAB LIVES”— actions a fire fighter must take to improve survivability, emergency breathing.
    • Self-Survival Skills: SCBA familiarization, emergency procedures, disentanglement, upper floor escape techniques.
    • Fire Fighter Expectations of Command: command-level mayday training, pre-mayday, mayday and rescue, post-rescue, expanding the incident-command system, communications.

    Keep watching the website and the IAFC’s Facebook, Twitter and LinkedIn pages for continuing updates to this year’s program and planning resources.

    Remember to visit the SHS Section’s website for more information on health and safety issues and the IAFF’s Health, Safety and Medicine’s website for more information on health, wellness and safety programs.

    Additionally, look for a comprehensive series of articles, activities, insights, downloads, podcasts, video clips and resources that will be posted each day of Safety, Health and Survival Week here on Commandsafety.com, Thecompanyofficer.com and Buildingsonfire.com.

    Announcements and campaign materials will begin posting in Mid-May.

    We will be offering a special series of live shows nightly on Taking it to the Streets on Firefighternetcast.com and blogtalkradio during the week of June 19-25, 2011 addressing key issues with a stellar line-up of fire service leaders.

    This will be an exceptional opportunity to listen in, call in and participate actively in the week’ theme of Surviving the Fire Ground – Fire Fighter, Fire Officer and Command Preparedness.

    These shows will be mission critical. Stay Tuned for more upcoming information.

    Be Self-Critical and a Learning Organization

    • In the meantime think about your operations; are you self-critical and a learning organization seeking to identify gaps or areas for improvement?
    • There is a lot that can be learned from our daily responses and operations, whether they be that single company response or that multiple alarm incident. 
    • All it takes is the recognition to see things for what they are and your may not be as good as you think and the understanding and desire to identify those conditions and improve .

     

    Addtional Resources, videos and images related to the Albuquerque (NM) Fire Department’s operations at the Royal Crown Apartment Complex

    Alpha Street Side View

     

    Aerial View from the Delta Side

     

    KASA News 13 photo by Alex Tomlin.

    Compromised Floor Assembly Traps Firefighters

    3 comments

    Residential Fire and Floor Compromise Norwichbulletin.com

    A Taftville (CT) Firefigher was caught in a compromised floor condition while fighting a fire in a residential occupancy on Friday morning April 15th in Norwich, CT., resulting in a mayday and RIT deloyment to support the extrication and firefighter removal from the interior.

    Published reports from Theday.com indicated a fire fighter issued a mayday after his foot plunged through the floor up to his knee, according to  according to Taftville (CT) Fire Chief Tim Jencks.

    Two other fire fighters held him up so he wouldn’t fall through any farther, while several others rushed over to help.

    A half dozen fire fighters worked to untangle wires that had dropped down from the sagging ceiling and to extricate the fire fighter from the damaged floor; the two who were holding him up also started to break through the floor, Jencks said.

    Mutual aid from the Yantic Fire Company as well as the rapid intervention team from the Mohegan Sun Tribal department responded. 

    • Fire ground Photos NorwichBulletin.com, HERE
    • Additional Links, HERE and HERE

    The single family residential occupancy was constructed in 1932 and was a four bedroom colonial design with 1,965 square feet of space. The floor assembly was conventional full dimensional wood floor joist construction.

    Two Story Four Bedroom Colonial, Circa 1932

    Alpha Side Post Fire

    Aerial View from Bing.com

     

    Here’s some diagrams and images for common floor joist assembly systems Circa 1932

     

     
     
     

     

    Common Balloon Frame Wall-Floor Construction

     

    Full Dimensional Floor Joists

    Circa 1930's Floor Joist Configurations

    Engineered Floor I-Joists and Firefigher Safety: Basic Insights

    1 comment

    The following videos provide some Basic insights on Engineered Floor I-Joists and Firefighter Safety. The first two video reports are a few years old, but provide some good visual and narrative insights into the current building construction trends, operational limitations and fireground tactical safety considerations.  

    Take the time to review these video clips and gain some new insights or refresh and reinforce your past knowledge of engineered floor systems, assemblies and tactical safety considerations. References and links to mission critical reports, studies and incidents is provided for your to expand your knowledge and skill base; for every rank and level of operations from firefighter, company or command officer.  

       

       

       

    Some insights on Engineered I-Joist construction and uses from a manufacture’s perspective….  

       

    Some insights on a newer type of I-Joist Hanger System interated into an Insulated concrete formwork system (ICF)
       

    Cut-outs in I Joists for HVAC runs
       

    If you’ve been paying attention to the latest news and on the job reports the past two month, you should have noticed there’s been an adverse emerging trend evident in near miss, close-calls resulting in maydays, RIT deployments and self-rescue resulting from floor compromise and floor collapse.I previously posted some research and links related to the first one or two events on Buildingsonfire on Facebook  HERE, It became evident that there was an immediate opportunity to get some learning’s and insights out. 

    If you have a chance head over to Facebook and link into Buildingsonfire and check out the incident links posted as well as some immediate report links from the December/January time frameIn the meantime here are some links I pulled together that you should take the time to read and share with your companies, personnel and staff…..Take the time to have a ten minute drill on these events as Operating Expeeince (OE) on floor systems and operational safety with your company, station or department.Take a look at your current SOP and SOG’s and determine if you have the right “stuff” in place to provide operational guidance and direction based upon your organization’s operational profile and capabilites.Is your training up to speed on size-up, risk profiling and command and compay level operations for conducting work at buildings and occupancies with actual or suspected engineered floor systems?Reference Links for Operational Insights and Operating Experience (OE)

    Here’s some screen shots from Buildingsonfire on Facebook. Go HERE or follow the link at the left column. Join the growing list of 3700 fans with Buildingsonfire on Facebook and Buildingsonfire.com   

      

    UL Testing

      

    UL Fire Academy CBT  

    • UL Structural Stability of Engineered Lumber in Fire Conditions
    • This two-hour presentation summarizes a research study on the hazards posed to firefighters by the use of lightweight construction and engineered lumber in floor and roof designs. This free on-line computer based presentation will allow fire professionals to better interpret fire hazards and assess risk for life safety of building occupants and firefighters.
    • This online firefighter training course is the result of a research partnership among UL, the Chicago Fire Department, IAFC, and Michigan State University, funded in part by the U.S. Department of Homeland Security. This self-guided course, which focuses on the structural stability of engineered lumber under fire conditions, is targeted toward the 1.1 million fire service personnel in the United States and Canada. The knowledge developed and shared in this course is critically important to firefighter and civilian safety.
    • This two-hour presentation summarizes a research study on the hazards posed to firefighters by the use of lightweight construction and engineered lumber in floor and roof designs. This free on-line computer based presentation will allow fire professionals to better interpret fire hazards and assess risk for life safety of building occupants and firefighters.
    • Program Objectives:
    • Provide brief history of events leading up to DHS Grant tests
    • Identify the fire test hypothesis, parameters, and steps completed in the testing process
    • Compare tests results (legacy vs. modern construction)
    • Communicate learnings from our partners representing the fire service
    • Discuss code recommendations
    • UL University on-line Program HERE

    Here’s a link to a past informative posting related to engineered systems and their relationship to firefighter safety and operations, HERE. There’s some great contributed information and manufacturer “insights” on the subject engineered wood I-joists and beams and firefighter safety. There are some interesting statistical extrapolations, correlations and conveniences’ that attempt to make the case. But then again, You be the judge. Take at look at the presentation developed by the American Forest and Paper Association, HERE and HERE.  

    If you haven’t done so yet, don’t forget to check out the free online training program on Structural Stability of Engineered Lumber in Fire Conditions at the UL University developed and provided by Underwriter’s Laboratories (UL),  HERE   

    Here’s an additional series of other important Reference Links that provide some insights on operational safety, incident conditions and factors ;   

    • NIOSH Publication No. 2009-114: Preventing Deaths and Injuries of Fire Fighters Working Above Fire-Damaged Floors HERE
    • NIOSH Publication No. 2005-132: Preventing Injuries and Deaths of Fire Fighters Due to Truss System Failures HERE
    • NFPA Report on Light Weight Construction, HERE
    • Informative USFA Coffee Break series postings related to Building Types & Fire Resistance:  HERE. HEREHERE, HERE, and HERE
    • Remember, Building Knowledge = Firefighter Safety (Bk-F2S)

    Buildingsonfire.com and the Command Institute

      

    Coming Spring 2011

    We’re finishing up with the content development and working on the supportive case studies and interactive group activities for an exciting new one day seminar program on that will address the leading issues, studies and reports specific to engineered floor and roof systems, incorporating the lastest UL and NIST test data and insights with cutting edge methodolgies and practices for firefighting operations.  

    • Engineered Structural Systems & Fireground Operations will be available for training bookings commencing in May 2011. Contact us for a new brochure and program details.

    In addition, look for a new updated 2011 Training Seminar brochure to download with a series of revised training seminars incorporating the newest operational insights  

    • Building Construction for the Command & Company Officer
    • Building Construction and Tactical Operations
    • Tactical Operations and the New Rules of Combat Fire Engagement
    • Dynamic Risk Assessment of Occupancies for Operational Safety
    • Reading the Building: Predictive Profiling Predictive Occupancy Profiling

    LAFD LODD: Hollywood Hills Mansion Investigating Building Standards

    3 comments

    38-year veteran Glenn L. Allen of the LAFD was killed battling a blaze at a Hollywood Hills home

    Hollywood Hills Mansion Investigating Building Standards

    As the funeral services commence today for 38-year veteran LAFD firefighter Glenn L. Allen  who was killed in the line of duty as a result of being trapped beneath rubble when the roof and ceiling collapsed during a blaze at a Hollywood Hills mansion on Feb. 17, the 12,000-square-foot home in the 1500 block of N. Viewsite Drive was declared a crime scene by police Wednesday.

    Investigators are looking into whether design and construction issues might have contributed to the collapse, the Los Angeles Building and Safety Department said.

    Authorities have ruled out arson as the cause of the blaze, LAPD Capt. Kevin McClure said Thursday, but have not yet determined the cause of the fire, or whether a crime was committed.

    The fire appears to have started near a fireplace and then extended into the attic, according to L.A. City Fire Deputy Chief Mario Rueda.

    Officials say arson is not a factor and apparently a plastic line in the home’s sprinkler system burned through and filled the ceiling with water.

    The LAPD’s robbery-homicide division is now in charge of the investigation, in conjunction with the Los Angeles Building and Safety Department and the L.A. Fire Department.

    According to published reports; “The city of Los Angeles has stringent building codes, and those building codes are made not only to protect residents, but also to protect our firefighters,” LAPD Chief Charlie Beck told KTLA. “So we’re looking into what exactly was the situation at that house.”

    Firefighters were on the roof trying to ventilate the house when the ceiling collapsed, Rueda said.

    The owners of the house, who had been living there for about a week, escaped the blaze unharmed.

    Five other firefighters were treated with injuries.

    The 61-year-old was about a year from retirement, according to fire officials

    Various insights and reports related to the investigation and focus on the building construction, permitting process and certificate of occupancy.

    Near-Misses, Maydays and Floor Collapses

    4 comments

    Do you know what's underneath you as you're making entry?

    If you’ve been paying attention to the latest news and on the job reports these past few days, you may have noticed there’s been an emerging trend evident in near miss, close-calls resulting in maydays, RIT deployments and self-rescue resulting from floor compromise and floor collapse. 

    As I was doing some research and posting links related to the first one or two events on Buildingsonfire on Facebook, HERE, it became evident that there was an immediate opportunity to get some learning’s and insights out. If you have a chance head over to Facebook and link into Buildingsonfire and check out the incident links posted as well as some immediate report links.

    I’ll plan to develop some operational safety and awareness insights related to building construction, floor systems and operational integrity in the next few days. I’ll get a comprehensive list of events and incident parameters compiled and posted also.

    In the meantime here are some links I pulled together that you should take the time to read and share with your companies, personnel and staff…..

    This seems like a good time to have a ten minute drill on these events as Operating Expeeince (OE) on floor systems and operational safety.

    Reference Links for Operational Insights and Operating Experience (OE)

    Here’s some screen shots from Buildingsonfire on Facebook. Go HERE or follow the link at the left column. Join the growing list of 3500 fans with Buildingsonfire on Facebook and Buildingsonfire.com (fully launching in January, 2011)

    Operational Safety at Basement Fires: Close Call

    4 comments

    Basement fires in both residential and commercial occupancies are one of the most challenging tactical operations that present numerous risk factors that required the highest degree of situational awareness, training skill sets and continuous incident monitoring and assessment to gauge building structural integrity, fire behavior and crew integrity and performance. 

    An explosion rocked a Fairdale, Kentucky neighborhood this past weekend while the homeowner was in the process of doing remodeling his basement. A Camp Taylor (KY) firefighter survived a floor collapse that momentarily trapped him proximal to the seat of a working basement fire. Camp Taylor (FD) Captain Mark Long sustained second and third degree leg burns after falling through the floor of the burning home and subsequently being rescue by other fire department personnel. 

    Fellow firefighters, including his brother-in-law, who was right behind him prior to his fall, were yelling and screaming at Long to hang on.  They managed to get a ladder to the basement and it was up to Long to find the strength to get out.  He says “I started to try to climb up. I got two, I lost my grip, fell flat into the fire.  I was so exhausted.” On his third attempt, he did find the strength and pulled himself up the ladder and out of the flames.  

    According to published reports a coordinated fire suppression effort was undertaken, with heavy fire involvement extending throughout the house and into the roof area. Interior fire attack was commenced, and as crews began moving across the first floor area above the seat of the fire, the floor subassembly failed causing an isolated collapse and compromise of the structural floor system and sub-floor decking, resulting in Captain Long falling into the basement. The fire originating in the basement was the result of the homeowners’ use of acetone as a floor treatment when the chemical vapors were ignited by the hot water heater causing an explosion and resulting fire. 

    Safety Considerations related to Residential Occupancies (non-inclusive) 

    • Conduct a thorough fire size-up and communicate the findings to all personnel on-scene before entering the building.
    • Conduct an assessment of the Building Profile ( building construction type, structural assembly systems and features and age) and assesss fire behavior and intensity levels.
    • Ensure an adequte Risk Assessement is conducted and that Risk versus Gain is determined
    • Maintain situational awareness throughout the tactical deployment of crews within the interior of the structure
    • Conduct a 360 degree perimeter assesement when feasible to determine access and egress points, fire location and travel and other mission critical operational perameters.
    • Incident commanders and company officers should be trained and experienced in structure fire size up to avoid putting fire fighters at unneeded risk of working above fire-damaged floors.
    • Do not enter a structure, room, or area when fire is suspected to be directly beneath the floor or area where fire fighters would be operating, or if the location of the fire is unknown.
    • Never assume structural safety of any floor (regardless of the construction) having a significant fire under it.
    • Conduct pre-incident planning inspections during the construction phase to identify the type of floor construction.
    • If pre-planning is not conducted, assume residential construction and small commercial buildings built since the early 1990s may contain engineered wood I-joists.
    • Report construction deficiencies noted during preplanning to local building code officials. For example, engineered wood floor joists should only be modified per manufacturer specifications—usually limited to cutting to length and removing pre–cut knockouts for utility access. Report damaged or cut chords or webs to building officials.
    • Develop, enforce, and follow standard operating procedures (SOPs) on how to size up and combat fires safely in buildings of all construction types. Rapid intervention teams (RIT) should include a portable ladder with their RIT equipment when deployed at basement fires.
    • Ensure Time Compression is considered: Ensure Command has the ability to monitor progress or elapsed incident time and adjusts strategic and tactical plans accordingly and in a time effective manner. 
    • Provide training on identifying signs of weakened floor systems (soft or spongy feel, heat transmitted through floor, downward bowing, etc.).
    • Make fire fighters aware that all floor types can fail with little or no warning.
    • Use a thermal imaging camera to help locate fires burning below or within floor systems, but recognize that the camera cannot be relied upon to assess the strength or safety of the floor. (Refer to the recent UL Test Data and Operational Safety Considerations ”Structural Stability of Engineered Lumber in Fire Conditions” available at http://www.uluniversity.us/ )
    • Fire fighters should be trained on the use of thermal imaging cameras, including limitations and difficulties in detecting fire burning below floor systems. (See reference to UL above)
    • Immediately evacuate and, if possible, use alternate exit routes when floor systems directly beneath the floor where fire fighters would be operating are weakened by fire.
    • Use defensive overhaul procedures after fire extinguishment in structures containing fire-damaged floor systems of all types.
    • Consider becoming active in the building code process and influence requirements for fire resistance of floor and ceiling systems to further fire fighter safety and health.
    • Ensure RIT personnel area staged and have complete a site assessment of the building and occupany upon thier arrival and set-up
    • Ensure that a rapid intervention team (RIT) is on the scene as part of the first alarm and in position to provide immediate assistance prior to crews entering a hazardous environment

    Here are some resources and case studies resulting from operations at floor collapses;

    Incident links; HERE, HERE, HERE and HERE 


     

    Buffalo, NY Three Alarm Fire and Double LODD Report

    10 comments

    8-26-2009 7-07-53 AMNIOSH released it’s report on the August 24, 2009 three alarm fire at 1815 Genesee Street in Buffalo, New York that resulted in the LODD of Lt. Charles McCarthy and FF Jonathan Croom. On August 24, 2009, 45-year-old career Lieutenant Charles McCarthy died following a partial floor collapse into a basement fire, and  34-year-old career fire fighter Jonathan Croom was fatally injured while attempting to rescue the Lieutenant.  The Buffalo Fire Department was dispatched for “an alarm of fire” with reported civilian(s) entrapment. Arriving units discovered a heavily secured mixed commercial/residential structure with smoke showing. Following failed initial attempts to locate an entry to the basement, crews located a door on Side 2 that provided access down a flight of stairs to a basement entry door. Repeated attempts were made to force open this basement door in order to search for trapped civilians, but crews had difficulty gaining access through this door because it was made of steel and locked and dead-bolted on both sides. Other crews on scene performed primary searches of the 1st and 2nd floors with no civilians found.

    Approximately 30 minutes into the basement fire, command ordered all interior crews to exit the structure to regroup because crews were still unable to gain access into the basement from Side 2. Additional manpower was sent with special tools to assist in breaching the basement door on Side 2. Lieutenant Charles McCarthy and two fire fighters from his crew entered into the structure from Side 1 to verify all fire fighters had exited a 1st floor deli. Lt. McCarthy following a hoseline into the structure, was well ahead of the other two fire fighters when the 1st floor partially collapsed beneath him. McCarthy fell with the floor into the basement, exposing him to the basement fire. The other two fire fighters immediately exited the deli after fire conditions quickly changed and shelving and displays fell on them; they were unaware of what had just occurred. Lt. McCarthy made several Mayday calls from within the structure and activated his PASS device. Confusion erupted exteriorly on scene when trying to verify who was calling the Mayday, their exact location, and how they got into the basement.

    The incident commander was aware that he had crews attempting to gain access into the basement from Side 2 but was unaware that there had been a floor collapse within the deli section of the structure. Simultaneously, FF Croom, a member of the fire fighter assistance and search team (FAST), was standing by outside  Lieutenant McCarthy’s point of entry when the Mayday calls came out. It is believed that FF Croom  knew where the Lt., was since he had gone in the structure with him earlier in the incident. FF Croom grabbed a tool, went on air, and rushed into the structure. The FAST and additional personnel on scene concentrated on Side 2 initially while other fire fighters followed an unmanned hoseline into the deli. Crews within the deli quickly discovered a floor collapse and reported hearing a PASS device alarming. Lt. McCarthy was immediately identified as missing during the first accountability check, but FF Croom was not accounted for as missing until the third accountability check, more than 50 minutes after Lt. McCarthy’s Mayday. After the fire was controlled, both victims were discovered side-by-side in the basement where the 1st floor had partially collapsed. They were found without their facepieces on and with SCBA bottles empty. the Lt’s. PASS device was still alarming. They were pronounced dead on scene. Four fire fighters and one lieutenant suffered minor injuries during the incident. No civilians were discovered within the structure.

    Key contributing factors identified in this investigation include working above an uncontrolled, free-burning basement fire; interior condition reports not communicated to command; inadequate risk-versus-gain assessments; and, crew integrity not maintained.

    NIOSH has concluded that, to minimize the risk of similar occurrences, fire departments should:

    • Ensure that all personnel are aware of the dangers of working above a fire, especially a basement fire, and develop, implement, and enforce a standard operating procedure (SOP) that addresses strategies and tactics for this type of fire.
    • Ensure that the incident commander (IC) receives interior status reports and performs/continues evaluating risk-versus-gain.
    • Ensure that crew integrity is maintained at all times on the fireground.
    • Ensure that the incident commander (IC) receives accurate personnel accountability reports (PAR) so that he can account for all personnel operating at an incident.
    • Ensure that a separate incident safety officer, independent from the incident commander, is appointed at each structure fire.
    • Ensure that fire fighters use their self-contained breathing apparatus (SCBA) and are trained in SCBA emergency procedures.
    YouTube Preview Image

     YouTube Preview Image

    1815 Genesee Street 1815 Genesee Street

    CONTRIBUTING FACTORS 

    Occupational injuries and fatalities are often the result of one or more contributing factors or key events in a larger sequence of events that ultimately result in the injury or fatality. NIOSH investigators identified the following items as key contributing factors in this incident that may have led to the fatalities:

    • Working above an uncontrolled, free-burning basement fire.
    • Interior condition reports not communicated to command.
    • Inadequate risk-versus-gain assessments.
    • Crew integrity not maintained.

    Time Line from the Buffalo (NY) Fire Department Investigative Report

    3:51 a.m. – fire crews were sent to 1815 Genesee Street in Buffalo. When they arrived, they were met by a resident who said he heard people trapped inside. Crews began searching the building, but were eventually ordered out as conditions deteriorated.

    4:22 a.m. – Members of Rescue 1 entered the building to make sure all firefighters had evacuated the building. Less than two minutes later the floor in the rear of the building collapsed. Lt. McCarthy of Rescue 1 fell into the basement as the floor collapsed. according to the report, other members of Rescue 1 were unaware of the collapse and only reported hearing a loud noise. McCarthy began calling for help on his radio, but other members of Rescue 1 were unable to determine where the calls were coming from and left the building unaware that Lt. McCarthy was trapped.

    4:23 a.m. – Firefighter Croom entered the building after hearing the calls for help. the report says he did not exit the building, apparently falling into the basement near Lt. McCarthy.

    4:31 a.m. – An emergency head count was ordered to determine the identity of the missing firefighter. Lt. McCarthy was reported missing at that time, but FF Croom was not. Firefighters in the front of the store reported hearing a pass alarm, but could not reach it due to extreme fire conditions, a weakened floor and continuing collapse.

    4:48 a.m. – all crews were ordered out of the building because it had become unsafe.

    Later, concerns began to arise that FF Croom was missing. the report says he was erroneously reported in a remote area.

    5:46 a.m. – On scene personal realize FF Croom is missing and likely inside the building.

    6:10 a.m. – Another head count is taken and FF Croom is reported missing.

    9:18 a.m. – the Recovery Group reports that the two missing firefighters had been located in the basement, covered in fallen debris.

    9:32 a.m. – the debris is cleared and Recovery Group firefighters reach Lt. McCarthy and FF Croom.

    Buffalo (NY) Fire Department Investigative Report, issued December 2, 2009, HERE

    For a comprehensive Power Point Program on Operational Safety at Heavy Timber and Ordinary Construction Occupancys that you can down load, go to the National Firefighter Near Miss Reporting Web Site HERE.

    I produced an informational training PPT program and support information that aligned with a previoulsy reported Near Miss Event Report. You can download the PPT Training Program HERE and the PDF File HERE

    NIOSH Fire Fighter Fatality Investigative Report 2009-23, HERE

    Engineered Structural Systems- Hazards

    3 comments

    600x6CNN recently presented an informative piece on the continuing trends in the design and use of engineered structural systems (ESS) . CNN correspondant Gerri Willis provides an informative and  insightful look at something the fire service knows all too well.  Here’s some additional information for you; According to the Wood Truss Council of America (WTCA), wooden trusses are used in roof systems in more than 60% of all buildings in the United States [SBCMAG 2004]. Truss and related engineered wooden floor systems are also becoming more common. Today, more engineered structures use lighter weight materials, producing larger spans and clear openings. Trusses can be designed to carry expected loads, be produced economically, be safely handled, and reduce construction costs.

    Engineered building components may provide adequate strength under normal loading; but under fire conditions, these truss systems can become weakened and fail, leading to the collapse of roofs, floors, and possibly the entire structure. Truss systems are usually hidden, and fires within truss systems may go unnoticed for long periods of time, resulting in loss of integrity.

    Structural design codes often do not factor in this decreased system integrity, as fire degrades the structural members. Fire fighters typically rely on warning signs to indicate imminent truss failure such as roofs and floors that feel spongy or are visibly sagging. Quite often, these warning signs are not good predictors of truss system failures. The United States Fire Administration (USFA) reports that during 1990-2000, structural fires and explosions accounted for 46.1% of all reported fire fighter fatalities (500 of 1,085) [USFA 2002].  Statistics compiled by the WTCA suggest that 4.7% of the total fatalities (108 of 2,286) during 1980-2001 were due to structural collapse [Grundahl 2003b]. Fifteen separate incidents investigated by NIOSH identified at least 20 fatalities and 12 injuries that have occurred from 1998-2003 during fire-fighting operations in buildings containing truss systems.

    http://us.cnn.com/video/?/video/living/2009/12/18/willis.new.housing.fire.danger.cnn CNN Reports on ESS Dangers

    At least three scenarios can occur in which fire fighters suffer fatalities and injuries while operating at fires involving truss roof and floor systems:
    1. While fire fighters are operating above a burning roof or floor truss , they may fall into a fire as the sheathing or the truss system collapses below them.
    2. While fire fighters are operating below the roof or floor inside a building with burning truss floor or roof structures , the trusses may collapse onto them.
    3. While fire fighters are operating outside a building with burning trusses , the floor or roof trusses may collapse and cause a secondary wall collapse.

    Building Construction Spring09 173