No More History Repeating Events-Remembrance

No comments

As we approach the July 4th holiday period, two significant LODD incidents previously occurred during this time frame that hold a number of lessons learned related to command management, operations, building construction principles and building performance, fire behavior and the ever present dangers of the job. Take the opportunity to learn more about these events, and expand your insights and knowledge base.  Those events being the 1988 Hackensack (NJ) Ford Fire which resulted in five (5) LODD and the 2002 Gloucester City (NJ) Fire that resulted in three (3) LODD along with three children.

Take a moment to reflect upon the supreme sacrifice made by these heroic firefighters and the messages that lay within the pages of the incident case studies, reports and summaries.  Our sister site TheCompanyOfficer.com   has a comprehensive overview of both events with report links and a must see video on the Gloucester City (NJ) 2002 LODD event. For Remembering Hackensack and Gloucester follow the link HERE

Remembrance (1988)

Hackensack (NJ) Fire Department
• CAPT. RICHARD L. WILLIAMS, Engine Co. No. 304
• LIEUT. RICHARD REINHAGEN, Engine Co. No. 302
• F/F WILLIAM KREJSA, Engine Co. No. 301
• F/F LEONARD RADUMSKI, Engine Co. No. 302
• F/F STEPHEN ENNIS, Rescue Co. No. 308
  

Remember (2002)

Gloucester City (NJ) Fire
• James Sylvester Fire Chief, Mount Ephraim Fire Department
• John West Deputy Chief, Mount Ephraim Fire Department
• Thomas G. Stewart III Paid Firefighter, Gloucester City Fire Department

Building Knowledge=Firefighter Safety

1 comment

Commandsafety.com is pleased to make available the latest update to the Buildingsonfire.com’s Building Construction Training and Lecture Series for 2010. Recently updated with a series of new seminar and training program topics addressing the emerging training and educational needs of the fire service, these programs provide timely and relevant information and insights on Building Construction, Command Risk Management, Dynamic and Extreme Fire Behavior, Occupancy Situational Awareness, Engineered Structural Systems and Fire Fighter Safety.

These programs also present and integrate cutting edge research and emerging concepts on Tactical Patience, Tactical Entertainment, Command Compression, Structural Anatomy of Buildings, Five Star Command Model, Predicative Strategic Process, refined Tactical Deployment Models integrating intelligent Structural Anatomy and Predictive Occupancy Profiling and much more.  

These programs, lectures and seminars examine crucial construction elements and occupancy types and correlates building construction performance toward combat structural fire suppression operations. Case studies will reinforce concepts presented and evoked open discussion and dialog on building construction and operational safety. These fast paced programs will utilize extensive multimedia materials, interactive activities, case study activities and simulations to reinforce course content and subject areas, providing exceptional learning opportunities.

Without understanding the building-occupancy relationships and integrating; construction, occupancies, fire dynamics and fire behavior, risk, analysis, the art and science of firefighting, safety conscious work environment concepts and effective and well-informed incident command management, company level supervision and task level competencies…You are derelict and negligent and “not “everyone may be going home”. Our current generation of buildings, construction and occupancies are not as predictable as past conventional construction; risk assessment, strategies and tactics must change to address these new rules of structural fire engagement. There is a need to gain the building construction knowledge and insights and to change and adjust operating profiles in order to safe guard companies, personnel and team compositions. It’s all about understanding the building-occupancy relationships and the art and science of firefighting, Building Knowledge = Firefighter Safety (Bk=F2S)

Down load the program files from the link below for more information.

Building Construction Training Programs 2010

 

Taking it to the Streets

1 comment

Coming July 2010

The Summer Tour is about to Begin..

Taking it to the Streets

With Christopher Naum

A New Monthly Radio Talkshow on FireFighter Netcast.com

A Buildingsonfire.com Series and FireFighter Netcast.com Production

Advancing FireFighter Safety and Operational Intergrity for the Fire Service through provocative insights and dynamic discussions dedicated to the Art and Science of Firefighting and the Traditions of the Fire Service.

Watch for the Latest Announcements here on CommandSafety.com, TheCompanyOfficer.com and on Firefighter Netcast.com

Programming

Ten Minutes in the Street

  • Presenting an informational recap and discussion on leading topcs, events and issues from the past 30 days.

Feature Segments Program will have one (1) selected segment based upon topic and guest

Buildingsonfire

  • Addressing today’s topical issues within the areas of Firefighting, Building Construction, Dynamic Risk Assessment, and Command & Tactical Safety
    • Open interative discussions and call-in
  • Street Stories
    • Presenting first-hand accounts and insights on an event, response or operation with a featured guest
    • Open interative discussions and call-in
  • Smoke Showin’
    • Featured Guest Interviews and discussions focusing on the NFFF Firefighter Life Safety Initiatives and Everyone Goes Home Campaign
    • Open interative discussions and call-in

HRE History Repeating Events

  • Discussion on recent History Repeating Events, LODD, NIOSH Reports or other
  • Open interative discussions and call-in

A View from the Street

  • Closing Commentary on timely and relevant issues affecting the Fire Service

In Search of Tactical Patience

1 comment

Today commemorates the anniversary of the Sofa Superstore fire in Charleston, South Carolina, in which nine firefighters lost their lives while engaged in aggressive interior operations at a commercial building occupied and operating as a furniture store and warehouse. On the evening of June 18, 2007, units from the Charleston Fire Department responded to a fire at the Sofa Super Store, a large retail furniture outlet in the West Ashley district of the city. Within less than 40 minutes, the fire claimed the lives of nine firefighters and changed the lives of countless others. The incident galvanized the nation’s fire service and to this day continues to generate commentary and observations within wide latitude of functional areas. What has changed since that day, three years ago?

The publication of the Routley Report was a wake-up call to the fire service, but did we hit the snooze button and roll back over? Are we catching those extra forty winks at the expense of what we should be jumping out of our bunks and engaging in? If you haven’t taken the time to read the authoritative reports, now is the time to do so. Make it one of your definitive activities for the weekend. Reflect upon its insights, recommendations and suggestions and think about your organization, department or agency.

Stop and think about where the fire service is today; where is your department today? Any measurable changes that reflect the front page news of past events or reports? Or is it business as usual? More importantly; where are YOU today? What have you done based upon the lessons learned or insights expressed to make you a better prepared and knowledgeable firefighter, officer or commander?

During the past twelve months of travels around the country presenting programs on building construction and command risk management and firefighter safety, there continues to be a common thread within the Fire Service that resonates loudly (at times and in some regions); “were’ just not getting it”.  Dialog and discussion, ranting and challenges; sometimes on the verge of aggression and hostility at times continue to punctuate and permeate program conversation and debate. We argue about the merits of operational aggressiveness at the expense of looking (and understanding) the ways to increase our proficiency and knowledge that can translate into refined and intelligent tactical operations.

I continue to suggest that it’s no longer just brute force and sheer physical determination that define structural fire suppression operations, although any seasoned firefighter and company officer knows that at times; it is what gets the job done under the most arduous and demanding of circumstances. However, from a methodical and disciplined perspective, aggressive firefighting must be redefined and aligned to the built environment and associated with goal oriented tactical operations that are defined by risk assessed and analyzed tasks that are executed under battle plans that promote the best in safety practices and survivability within know hostile structural fire environments.

We can still meet the demands of the job, as firefighters; but do it with Tactical Patience and not at the expense of Command Compression and Tactical Entertainment or worst Operational Recklessness.

The traditional attitudes and beliefs of equating aggressive firefighting operations in all occupancy types coupled with the correlating, established and pragmatic operational strategies and tactics must be adjusted and modified to include intelligent risk assessment, calculated risk analysis, safety and survivability profiling, and strategic operational and tactical value. The demands and requirements of modern firefighting will continue to require the placement of personnel within situations and buildings that carry risk, uncertainty and inherent danger. As a result, risk management must become fluid and integrated with intelligent tactical deployments and operations recognizing the risk problematically and not fatalistically, resulting in safety conscious strategies and tactics. We need to think about the Predicative Strategic Process, refined Tactical Deployment Models integrating intelligent Structural Anatomy and Predictive Occupancy Profiling. ( more on these in upcoming posts…)

Take the time today to remember and honor the Charleston Nine.

Comprehend the sacrifice and grasp the essence of our noble profession and the tradition of the Fire Service. Remember the past and learn from it and improve the future so that that the cycle of potential history repeating events is disrupted and eventually broken.

Work conscientiously and diligently to improve our profession and yourself; identifying gaps, correcting the deficiencies and improving the job, through a legacy of operational excellence and safety- for tomorrow’s firefighters.

Honor and Remembrance- The Charleston Nine

  • Bradford Rodney “Brad” Baity – Engineer 19
  • Theodore Michael Benke – Captain 16
  • Melvin Edward Champaign – Firefighter 16
  • James “Earl” Allen Drayton – Firefighter 19
  • Michael Jonathon Alan French – Engineer 5
  • William H. “Billy” Hutchinson, III – Captain 19
  • Mark Wesley Kelsey – Captain 5
  • Louis Mark Mulkey – Captain 15
  • Brandon Kenyon Thompson – Firefighter 5

Ten Minutes in the Street: Interactive Scenarios Returning to Firefighter Nation

No comments
Ten Minutes in the Street

 After a bit of an extended hiatus on the lecture circuit, Ten Minutes in the Street is returning to the Firefighter Nation Forums with more of what you came to expect with high quality scenarios and thought provoking discussions to get you engaged and thinking: strategically and tactically with a balanced risk approach.

 We launch the summer series of Ten Minutes in the Street Scenarios during this year’s Safety, Health & Survival Week starting on June 21.

These interactive scenario programs will be featured weekly on the FFN Fire Ground Tactics and FireFighter Safety Forum, HERE

In the mean time, here are some great Ten Minutes in the Street Scenarios that we presented, take some time to look these over if you’re new to the content and interactive participation.

  • Ten Minutes in the Street: Read “through” the Smoke, HERE
  • Ten Minutes in the Street; “But its only a Garage..!”, HERE
  • Ten Minutes in the Street; Pipin’ Hot First Due..30 Minutes or Less, HERE
  • Ten Minutes in the Street; “Here’s lookin’ at You”, HERE
  • Ten Minutes in the Street; Stretchin’ the line on the First-Due, HERE

Also, take a moment to check out our other activity and postings at Fire EMS Blogs at TheCompanyOfficer.com. You can also follow the latest informational links on Facebook at Buildingsonfire.com 

Can you keep a secret? Stay tuned for some great upcoming  announcements regarding a new program series that will be brought to you by some very familiar names…..”The Summer Tour is about to begin..”

Maintaining Situational Awareness

2 comments

00-EOY-ss-buildingcollapseMaintaining focused situational awareness while recognizing and processing a wide latitude of incoming information and observations at complex and multiple alarm incidents is a significant challenge to even the most experienced of incident command teams. However, things can go wrong and they can go wrong in a rapidly escalating manner with little time to recover. A prominent double LODD incident from six years ago provides poignant lessons learned as does another history repeating event (HRE) from 1972.

The Ebenezer Baptist Church fire in Pittsburg, PA (2004) and the Hotel Vendome Fire in Boston, MA (1972) have a number of commonalities related to extended multi-alarm operations, building compromise and collapse and multiple line-of-duty deaths of operating fire service personnel. Although building type, construction features and systems are unique for each incident as are the circumstances that lead to the events, there are mission critical lessons to be reexamined or newly introduced if you’re not familiar with either event. This is especially true when we talk about operational challenges and adverse conditions that result in firefighter injuries and fatalities during overhaul and take-up phases of an incident.

Remember Situation Awareness, [SA], is the perception of environmental elements within a volume of time and space, the comprehension of their meaning, and the projection of their status in the near future. It is also a field of study concerned with perception of the environment critical to decision-makers in complex, dynamic situations and incidents.

Both the 2006 and 2007 Firefighter Near-Miss Reporting System Annual Reports identified a lack of situational awareness as the highest contributing factor to near misses reported. Situation Awareness (SA) involves being aware of what is happening around you at an incident to understand how information, events, and your own actions will impact operational goals and incident objectives, both now and in the near future. Lacking SA or having inadequate SA has been identified as one of the primary factors in accidents attributed to human error (Hartel, Smith, & Prince, 1991) (Nullmeyer, Stella, Montijo, & Harden, 2005). Situation Awareness becomes especially important in work related domains where the information flow can be quite high and poor decisions can lead to serious consequences.

To the Incident commander, Fire Officer or firefighter, knowing what’s going on around you, and understanding the consequences is mission critical to incident stabilization and mitigation and profoundly crucial in terms of personnel safety. The integration of Situational Awareness and Dynamic Risk Assessment is a mission critical element in strategic incident command management and company level tactical operations as we go forward into the next decade. We’ll expand on some posting in the near future and address Dynamic Risk Assessment in the context of building and occupancy profiling and operations. Additionally, maintaining a heightened sense of risk and safety integrity when operating within non-combat fire suppression modes or phases also requires due diligence, focused and fluid situational awareness coupled with concise monitoring of building conditions, indicators (both evident and projected) and taking conservative actions and postures to ensure personnel are not placed in high risk, no value positions that have a high potential for error likely outcomes.

Check out the detailed posting at our sister site TheCompanyOfficer.com for insights into both the Ebenezer Baptist Church fire in Pittsburg, PA (2004) and the Hotel Vendome Fire in Boston, MA (1972) HERE. Think about the questioned posed related to complex multi-company operations, command safety and operational integrity of compromised buildings and structural systems. Remember; Building Knowledge=Firefighter Safety.

Risk versus Gain: Operations in Vacant or Abandoned Structures

8 comments

DFD102406138Risk versus Gain: Operations in Vacant or Abandoned Structures

Fire Fighter LODD after Being Trapped in a Roof Collapse During Overhaul of a Vacant/Abandoned Building. NIOSH recently published a report on a 2008 LODD that occurred in a vacant/ abandoned building. NIOSH Report F2008-0037. The full report is available HERE. Let’s look at some insights and overviews of that report.

Report Summary

On November 15, 2008, a 38-year-old male fire fighter  died after being crushed by a roof collapse in a vacant/abandoned building. Fire fighters initially used a defensive fire attack to extinguish much of the fire showing from the second-floor windows on arrival. After the initial knockdown, fire crews entered the second floor to perform overhaul operations. During overhaul, the roof collapsed with several fire fighters still inside, on the second floor. The victim and two other fire fighters were trapped under a section of the roof. Crews were able to rescue two fire fighters (who self-extricated), but could not immediately find the victim. After cutting through roofing materials, the victim was located by fire fighters, unconscious and unresponsive.

He was removed from the structure and transported to a local hospital where he was pronounced dead. Key contributing factors identified in this investigation include: dilapidated building conditions, incendiary fire originating in the unprotected structural roof members, inadequate risk-versus-gain analysis prior to committing to interior operations involving a vacant/abandoned structure, inadequate accountability system, lack of a safety officer, an inadequate maintenance program for self-contained breathing apparatus (SCBA) and a poorly maintained and likely inoperable personal alert safety systems (PASS), ineffective strategies for the prevention of and the remediation of vacant/abandoned structures and arson prevention.

Inherent Construction Issues

This incident occurred in a vacant unsecured residential structure which had experienced a previous fire approximately one year prior to this incident. During interviews with NIOSH investigators, fire fighters reported large amounts of fire showing from all windows on the second floor on arrival. Fire fighters also reported that the roof had burned through on the Side B/C and one fire fighter reported he could see the sky while ascending the interior stairs to perform overhaul. It is not known if the roof conditions were communicated to the incident commander before fire fighters were assigned to operate on the roof. The fire fighters were unaware of the conditions such as the exposed roof assembly, possible removal of rafter connectors (collar beams), and the use of a flammable liquid in the structural members of the roof and second floor attic area. The roof assembly (being unprotected) was directly involved as part of the fuel in this fire.

The large dormer on the A-side presents an identifiable inherent risk factor (due to the potential for structural compromise or failure) when found on 1.5 story bungalow style residential structure due to the integral manner in which the dormer structure, i.e., roof rafters, dormer framing and roofing boards along with the functionality of the ridge beam must function in order to retain structural integrity under fire conditions. The dormer may be actually supported at the upper end directly onto the roofing boards, which in turn are supported by the perpendicular roof rafters. This creates a potential area for pronounced degradation when exposed to direct or indirect flame impingement creating an area prone to early structural compromise and eventual failure.

Although the initial defensive strategy in fighting the fire was successful in knocking down the fire, the incident commander may have benefited from a continuous risk-versus-gain analysis before allowing crews to operate on interior during overhaul. The first arriving officer reported that he performed a walk around prior to allowing crews to enter the structure and the building appeared intact, but he would not have known of the alterations to the interior roof system and the removal of critical structural members. Interior condition and roof condition reports might have revealed the burned-through area of the roof, and tactics could have been altered to keep fire fighters off the roof and out of the structure.

Report Recommendations included;

  • Ensure that the incident commander conducts a risk-versus-gain analysis prior to committing to interior operations in vacant/abandoned structures and continues the assessment throughout the operations
  • Ensure SOPs are developed for fighting fires in vacant/abandoned buildings
  • Ensure that the incident commander maintains close accountability for all personnel operating on the fireground
  • Ensure that a separate incident safety officer, independent from the incident commander, is appointed at each structure fire
  • Ensure that a respiratory protection program is in place to provide for the selection, care, maintenance, and use of respiratory protection equipment, including PASS devices.

Additionally, municipalities and local authorities having jurisdiction should:

  • Develop strategies for the prevention of and the remediation of vacant/abandoned structures and for arson prevention.

Although there is no evidence that the following recommendations could have prevented this fatality, NIOSH investigators recommend that fire departments:

  • Ensure that an EMS unit is on scene and available for fire fighter emergency care at working structure fires
  • Develop inspection criteria to ensure that all protective ensembles meet the requirements of NFPA 1851, Standard on Selection, Care, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting
  • Be aware of programs that provide assistance in obtaining alternative funding, such as grant funding, to replace or purchase fire equipment that can support critical fire department operations.

Vacant or Unoccupied: Tactical Risk and Safety

I’ve commented on this subject a few times. We seem to do a lot of things at times out of common practice and repetition, you know; “We’ve always done it that way….” syndrome. There’s a resonating theme that is making its way around the fire service dealing with going to a defensive tactical posture at vacant or unoccupied structure fires.

This command posture leads to limiting interior operating engagement, while promoting a high degree of risk management. With that being said, there are also plenty of opinions on these types of policies as such, since this type of tactical effort may be contrary to the local “culture and traditions” of the responding agencies and may be a hard pill to swallow, since we’re in the job of “ fighting ALL fires..” Please refresh your memories on a past post on Tactical Entertainment HERE and HERE

Here are some basic definitions to keep us all on the same playing field;

Vacant; refers to a building that is not currently in use, but which could be used in the future. The term “vacant” could apply to a property that is for sale or rent, undergoing renovations, or empty of contents in the period between the departure of one tenant and the arrival of another tenant. A vacant building has inherent property value, even though it does not contain valuable contents or human occupants.

Unoccupied; generally refers to a building that is not occupied by any persons at the time an incident occurs. An unoccupied building could be used by a business that is temporarily closed (i.e. overnight or for a weekend). The term unoccupied could also apply to a building that is routinely or periodically occupied; however the occupants are not present at the time an incident occurs. A residential structure could be temporarily unoccupied because the residents are at work or on vacation. A building that is temporarily unoccupied has inherent property value as well as valuable contents.

Here’s a formulative question;

  • As a responding company, you arrive at the scene of a vacant or unoccupied structure. The building’s construction features and systems have inherent risk associated with the occupancy, (as is the case with nearly all of our structures and occupancies).
  • Your company determines that you’re going to go defensive, even though you probably could make a reasonably safe entry and engage in interior structural fire suppression.
  • Would there be any repercussions in your station, battalion/district/community or organization if you took this tactic?
  • What are YOUR personal thoughts on this form of risk management?

 Some insights, HERE and HERE, HERE, HERE and HERE

Additional Links, HERE, HERE and HERE

The “Routiness” of Success, Or Not..

No comments

BM11

It’s no longer just brute force and sheer physical determination that define structural fire suppression operations. Aggressive firefighting must be redefined and aligned to the built environment and associated with goal oriented tactical operations that are defined by risk assessed and analyzed tasks that are executed under battle plans that promote the best in safety practices and survivability within known hostile structural fire environments, while maintaining the values and traditions that defines the fire service.”- Christopher Naum

The lack of appreciation and the understanding of correlating principles involving fire behavior, fuel and rate of heat release and the growth stages of compartment fires within a structural occupancy are the defining paths from which the fire service must reexamine coordinated suppression operations in order to identify with; the predictability of occupancy performance during fire suppression operations, thus increasing suppression effectiveness and firefighter safety.

Our buildings have changed; the structural systems of support, the degree of Compartmentation, the characteristics of materials and the magnitude of fire loading. The structural anatomy, predictability of building performance under fire conditions, structural integrity and the extreme fire behavior; accelerated growth rate and intensively levels typically encountered in buildings of modern construction during initial and sustained fire suppression have given new meaning to the term combat fire engagement.

 

 It begs to suggest that many of today’s incident commanders, company officers and firefighters lack the clarity of understanding and comprehension that correlate to the inherent characteristics of today’s buildings, construction and occupancies and the need for refined suppression operations within the modern building construction setting.

 

We assume that the routiness or successes of our operations and incident responses equates with predictability and diminished risk to our firefighting personnel. Does your company, your officers, your commanders, your department treat all things as equals when addressing the variables of structural combat fire operations? Is the equation of Occupancy Risk balanced with Occupancy Type? Are inherent structural stability and compromise conditions adequately identified and considered in the evolving progression of an incident action plan? Or do SOP and SOG’s drive the manner in which fire ground strategies and tactics are orchestrated and implemented at the company task level?

 

How does this fit into your “culture, values and philosophy as a firefighter, officer or commander?”

Predictability of Occupancy Performance during Suppression Operations

6 comments

2-2-2009 3-20-14 PMOur buildings have changed; the structural systems of support, the degree of compartmentation, the characteristics of materials and the magnitude of fire loading. The structural anatomy, predictability of building performance under fire conditions, structural integrity and the extreme fire behavior; accelerated growth rate and intensively levels typically encountered in buildings of modern construction during initial and sustained fire suppression have given new meaning to the term combat fire engagement.

The rules for combat structural fire suppression have changed, but we have yet to write the rule book from which the new games plans must be derived. We seek the elusive “Rosetta stone” that aligns and interprets the emerging and traditionalist acumen related to fire stream effectiveness, flow rates, cooling capacity, extreme fire behavior and fire dynamics, compartment fire theory, propagation and cooling capacity and tactical deployment all relate towards defining an engineering approach to firefighting tactics versus the manual, labor-driven tactics of line deployment and rudiment placement of water on a fuel source within the fire compartment (room).

It’s no longer just brute force and sheer physical determination that defines structural fire suppression operations. It begs to suggest that many of today’s incident commanders, company officers and firefighters lack the clarity of understanding and comprehension that correlate to the inherent characteristics of today’s buildings, construction and occupancies and the need for refined engine company operations within the modern building construction setting. We assume that the routiness or successes of our operations and incident responses equates with predictability and diminished risk to our firefighting personnel.

The work of such notable suppression theory pioneers as P. Grimwood, E. Hartin, S. Särdqvist and S. Svennson and the concepts surrounding 3D firefighting, B-SAHF and other emerging research from the NIST and UL are areas that today’s discerning and progressive fire officer and commanders must become well-informed and conversant. The quantitative scientific data and emerging concepts from continuing research and testing such as the NIST’s Wind Drive Fire Studies and UL’s The Structural Stability of Engineered Lumber in Fire Conditions are providing enlightenment on fire development, fuel controlled and ventilation controlled fire development, operational time-duration parameters and degradation and failure mechanisms related to compromise and structural collapse in occupancies.

Our current generation of buildings, construction and occupancies are not as predictable as past conventional construction, therefore risk assessment, strategies and tactics must change to address these new rules of combat structural fire engagement.

  • Building Construction Systems
    • Heritage
      • Pre-1919
    • Legacy
      • 1920-1949
    • Conventional
      • 1950-1979
    • Engineered
      • 1980-2010
    • Hybrid
    • Chameleon

The fundamental compartment that comprised a typical room configuration in terms of area (square footage), volume (height/Width), furnishings (fire load package) and materials of construction (structural anatomy) found within conventional, legacy or heritage construction provided predictability in terms of fire suppression, fire behavior, operational time and survivability (civilian/firefighter). The dramatic changes since the early 1980’s in the evolution of modern building construction and the institutionalization of engineered structural systems (ESS) have created compartment (room) areas in excess 500 SF, volumes that are open and spaciously interconnected to other habitable space, fire load packages that create extreme fire behavior, compromising structural stability in shorter time spans creating decreasing interior operational time and requiring increasing fire flow rates and volume to sustain requisite extinguishment demands.

Commanders and Company Offices need to gain new insights and knowledge related to the modern building occupancy and to modify and adjust operating profiles in order to safe guard companies, personnel and team compositions. Strategies and tactics must be based on occupancy risk not occupancy type and must have the combined adequacy of sufficient staffing, fire flow and nozzle appliances orchestrated in a manner that identifies with the fire profiling, predictability of the occupancy profile and accounts for presumed fire behavior. Today’s engine company operations and fire suppression theory has to progress beyond the pragmatic approaches to fire suppression such as “Big Fire-Big Water principle.

When we look at various buildings and occupancies, past operational experiences; those that were successful, and those that were not, give us experiences that define and determine how we access, react and expect similar structures and occupancies to perform at a given alarm in the future. Naturalistic (or recognition-primed) decision-making forms much of this basis. We predicate certain expectations that fire will travel in a defined (predictable) manner that fire will hold within a room and compartment for a predictable given duration of time; that the fire load and related fire flows required will be appropriate for an expected size and severity of fire encountered within a given building, occupancy, structural system; in addition to having an appropriately trained and skilled staff to perform the requisite evolutions.

Executing tactical plans based upon faulted or inaccurate strategic insights and indicators has proven to be a common apparent cause in numerous case studies, after action reports and LODD reports. Our years of predictable fireground experience have ultimately embedded and clouded our ability to predict, assess, plan and implement incident action plans and ultimately deploy our companies-based upon the predictable performance expected of modern construction and especially those with engineered structural systems.

If you don’t fully understand how a building truly performs or reacts under fire conditions and the variables that can influence its stability and degradation, movement of fire and products of combustion and the resource requirements for fire suppression in terms of staffing, apparatus and required fire flows, then you will be functioning and operating in a reactionary manner, that is no longer acceptable within many of our modern building types, occupancies and structures. This places higher risk to your personnel and lessens the likelihood for effective, efficient and safe operations. You’re just not doing your job effectively and you’re at RISK. These risks can equate into insurmountable operational challenges and could lead to adverse incident outcomes. Someone could get hurt, someone could die, it’s that simple; it’s that obvious.

Considerations for changing fire flow rates, the sizing of hose line and the adequacies for fire flow demand and application rates, staffing needs for safe operations, considerations for defensive positioning and defensive operating postures must be considered, and it warrants repeating again; Reckless-Aggressive firefighting must be redefined in the built environment and associated with goal oriented tactical operations that are defined by risk assessed and analyzed tasks that are executed under battle plans that promote the best in safety practices and survivability within known hostile structural fire environments- with determined, effective and proactive firefighting

  • Doctrine of Combat Fire Engagement
    • Predictive Strategic Process
    • Tactical Deployment Model
    • Dynamic Tactical Deployment
    • Performance Indicators and Street Aides
      • Fire Dynamics
      • Resistance
      • Resilience
      • Structural Systems
      • Occupancy Hazard Profiles

The traditional attitudes and beliefs of equating aggressive firefighting operations in all occupancy types coupled with the correlating, established and pragmatic operational strategies and tactics must not only be questioned, they need to be adjusted and modified; risk assessment, risk-benefit analysis, safety and survivability profiling, operational value and firefighter injury and LODD reduction must be further institutionalized to become a recognized part of modern firefighting operations.

Aggressive firefighting must be redefined and aligned to the built environment and associated with goal oriented tactical operations that are defined by risk assessed and analyzed tasks that are executed under battle plans that promote the best in safety practices and survivability within known hostile structural fire environments.

Our current generation of buildings, construction and occupancies are not as predictable as past conventional or legacy construction and occupancies;

  • Risk assessment, strategies and tactics must change to address these new rules of structural fire engagement.
  • You need to gain the knowledge and insights and to change and adjust your operating profile in order to safe guard your companies, personnel and team compositions.
  • Again strategic firefighting operations; Strategies and tactics must be based on occupancy risk not occupancy type.

The following are quotes from Fire Chief Anthony Aiellos (ret) Hackensack (NJ) Fire Department, Fire Chief during the Hackensack Ford Fire, July, 1988…

“If you don’t fully understand how a building truly performs or reacts under fire conditions and the variables that can influence its stability and degradation, movement of fire and products of combustion and the resource requirements for fire suppression in terms of staffing, apparatus and required fire flows, then you will be functioning and operating in a reactionary manner. This places higher risk to your personnel and lessens the likelihood for effective, efficient and safe operations. You’re just not doing your job effectively and you’re at RISK. These risks can equate into insurmountable operational challenges and could lead to adverse incident outcomes”.

Executing Effective Tactical Plans

No comments

45418t1When we look at various buildings and occupancies, past operational experiences; those that were successful, and those that were not, give us experiences that define and determine how we access, react and expect similar structures and occupancies to perform at a given alarm in the future. Naturalistic (or recognition-primed) decision-making forms much of this basis. We predicate certain expectations that fire will travel in a defined (predictable) manner that fire will hold within a room and compartment for a predictable given duration of time; that the fire load and related fire flows required will be appropriate for an expected size and severity of fire encountered within a given building, occupancy, structural system; in addition to having an appropriately trained and skilled staff to perform the requisite evolutions.

Executing tactical plans based upon faulted or inaccurate strategic insights and indicators has proven to be a common apparent cause in numerous case studies, after action reports and LODD reports. Our years of predictable fireground experience have ultimately embedded and clouded our ability to predict, assess, plan and implement incident action plans and ultimately deploy our companies-based upon the predictable performance expected of modern construction and especially those with engineered structural systems.

It’s more than just Size-Up; Situational Awareness and Dynamic Risk Assessment

2 comments
FLASHO1Dynamic Risk Assessment is commonly used to describe a process of risk assessment being carried out in a changing or evolving environment, where what is being assessed is developing as the process itself is being undertaken.
This is further problematical for the Incident Commander when confronted with competing or conflicting incident priorities, demands or distractions before a complete appreciation of all mission critical or essential information and data has been obtained. The dynamic management of risk is all about effective, informed and decisive decision making during all phases of an incident.
Situation Awareness, [SA], is the perception of environmental elements within a volume of time and space, the comprehension of their meaning, and the projection of their status in the near future. It is also a field of study concerned with perception of the environment critical to decision-makers in complex, dynamic situations and incidents.
Both the 2006 and 2007 Firefighter Near-Miss Reporting System Annual Reports identified a lack of situational awareness as the highest contributing factor to near misses reported. Situation Awareness (SA) involves being aware of what is happening around you at an incident to understand how information, events, and your own actions will impact operational goals and incident objectives, both now and in the near future. Lacking SA or having inadequate SA has been identified as one of the primary factors in accidents attributed to human error (Hartel, Smith, & Prince, 1991) (Nullmeyer, Stella, Montijo, & Harden, 2005). Situation Awareness becomes especially important in work related domains where the information flow can be quite high and poor decisions can lead to serious consequences.
To the Incident commander, Fire Officer or firefighter, knowing what’s going on around you, and understanding the consequences is mission critical to incident stabilization and mitigation and profoundly crucial in terms of personnel safety. The integration of Situational Awareness and Dynamic Risk Assessment is a mission critical element in strategic incident command management and company level tactical operations as we go forward into the next decade.
Traditional incident scene size-up is antiquated and no longer appropriate or applicable to modern fire service operations.Situational awareness is a combination of attitudes, previously learned knowledge and new information gained from the incident scene and environment that enables the strategic commanders, decision-makers and tactical companies to gather the information they need to make effective decisions that will keep their firefighters and resources out of harm’s way, reducing the likelihood of adverse or detrimental effects.
According to a 1998 published TriData study report, “Situational Awareness is one of the most difficult skills to master and is a weakness in the fire community. The report goes on to state that “The culture must change so that [personnel] are observing, thinking, and discussing the situation constantly.” It’s all about implementing effective human performance tools; perceptions versus reality, expectations versus realization, comprehension and forecasting, informed decision-making and calculated and formulated risk.
 
It’s a whole lot more than just “Size-Up”.  What do you think?

Twenty Ten

1 comment

august_detailAs we transition into a new year, and as plans begin to take place that frame and outline the year’s activities, foremost in this planning, preparation, scheduling and outlook should be those activities and commitments that training, education and skill development can be implemented and enhanced. Take the initiative to recognize and identify training and operational gaps and distinguish the risk and options available to lessen or eliminate the risk and reduce the gap deficiencies. Take the time to implement effective, accurate and frequent training and skill development drills, training curriculums and programs.

Don’t sacrifice or forego on this mission critical area when so much is at stake in the domain of combat structural fire suppression. Understand the predictability of performance in the buildings and occupancies not only in your jurisdiction, first or second-due areas, but also in those areas that you may be called upon to respond to for greater alarms or mutual aid. Remember Building Knowledge = Firefighter Safety.

Keep an eye in the rear view mirror; learning from the wisdom and knowledge from where you’ve been, what you’ve done and all your past experiences and practice; but at the same time focusing on the road before you with keen attentiveness on situational awareness, anticipating error-likely conditions and balanced risk assessment and operational management in both your strategic and tactical deployments. 

Twenty Ten(2010)

 Here are twenty (20) Suggested activities or initiatives for you to consider in 2010….

Above all, be safe in all your endeavors, assignments and incident tasks.

  1. Regardless of my years of experience, I will increase my understanding of the basic principles of Building Construction, because; Building Knowledge=Firefighter Safety.  
  2. Identify ten (10) buildings within your first-due or response district and complete a pre-fire plan and present this to my company of organization.
  3. Identify an area where new residential construction is underway and follow the construction process from foundation through completion to gain an understanding of operational issues.
  4. I will complete the UL Structural stability of engineered lumber in fire conditions online course and implement the lessons learned in my strategic and tactical operations.
  5. I will not take any building or occupancy for granted, and shall take all precautions to ensure crew integrity and safety during my task assignments.
  6. Complete a 360 assessment of all buildings upon arrival, when ever feasible to gain reconnaissance information on the building and incident risks and implement this info into my strategic, tactical plans or company task assignments.
  7. Research the issues affecting; Engineered Structural Systems (ESS), Fire Behavior/Fire Dynamics or Fire Suppression Management/Fire Loading and develop a training drill to share the lessons learned.
  8. Select a new or previous published fire service text book and read up on a subject area that I may have neglected or ignored to increase my skill set.
  9. Implement an objective approach towards effective risk assessment and profiling of all buildings and occupancies during incident operations and implement balanced tactical deployment with aggressive/measured assignments; recognizing that my company and I are not invincible.
  10. During demanding Combat Structural Fire Engagements, I will; Do the Right Thing at the Right Time for the Right Reasons and will not practice Tactical Entertainment.
  11. Read the Report of the Week (ROTW) on the National Firefighter Near-Miss Reporting System web site and share the operating experience (OE) lessons with my company or department, to reduce the likelihood of a similar or more serious event.
  12. I will read Ten (10) NIOSH Firefighter Fatality Investigation and Prevention Program Reports and present the lessons learned in a discussion, table top, drill or training program.
  13. I will attend a regional or national training conference to increase my perspective and awareness of other firefighting, safety or operational methodologies, process or practices to increase firefighter safety in my home organization.
  14. I will increase my understanding of the NFFF Everyone Goes Home Program initiatives, including the Sixteen Firefighter Life Safety Initiatives, Safety Thru Leadership and the Courage to Be Safe Programs and other new program initiatives and advocate and promote enhanced safety measures in my organization.
  15. I will advocate and promote safe and defensive apparatus operations during emergency responses and will always buckle-up my seat belt and ensure my crew is always belted-in, not placing my company at risk and obeying traffic signals and postings.
  16. I will implement the New Rules of Engagement during combat structural fire operations; while monitoring and reacting to on-going building performance and fire behavior.
  17. I will increase my understanding of the Predictability of Building Performance and base my operational deployments on Occupancy Risk not Occupancy Type.
  18. I will become a mentor to a new or less experienced firefighter and promote the traditions, honor and duty of our fire service profession, tempered with an emphasis on firefighter safety, survival and wellness.
  19. I will take NO emergency incident responses as being routine in nature, due to frequency , regularity or  past performance, demands or outcomes, nor will I take any building for granted; Company, Team and personal safety and integrity is paramount and I will not be complacent, but remain vigilant based upon my training, skills and experience.
  20. This one’s for you to identify and fill in………..

Ensure you’re glancing occasionally in your rear view mirror to monitor where you’ve been, while driving your initiatives, programs, processes and actions forward. Above all, maintain the courage to be safe. We don’t know what’s in the cards on any given day, but the citizens we protect can rest assured, we will do our job as firefighters, to the best of our abilities, because of who we are; today, in 2010 and certainly well into the next decade and beyond. Stay safe, with the hopes for a Happy New Year.

Predicated Building Performance

No comments

6When we look at various buildings and occupancies, past operational experiences; those that were successful, and those that were not, give us experiences that define and determine how we access, react and expect similar structures and occupancies to perform at a given alarm in the future. Naturalistic (or recognition-primed) decision-making forms much of this basis.

We predicate certain expectations that fire will travel in a defined (predictable) manner that fire will hold within a room and compartment for a given duration of time, that the fire load and related fire flows required will be appropriate for an expected size and severity of fire encountered within a given building, occupancy, structural system. That may be true for conventional or legacy structures, but what about modern construction and engineered structural systems? Same expectations?…….

What do you think?

There’s a great series of photos depicting initial operations at a small-sized (square foot) single family residential occupancy fire that captures fire and smoke behavior, HERE and HERE

Take at look the at this residential fire and interior attack that injured a number of Maryland Firefighters HERE

Take a moment to look back at an incident: On December 18, 1998, Three FDNY Firefighters died in-the line of duty while conducting suppression and rescue operations at fire on the tenth floor of 10-story high-rise apartment building for the elderly. This wind-driven fire event and the lessons-learned contributed directly to the current body of research and new insights on emerging strategies and tactics. NIOSH Report HERE. NIST References HERE

Take the time to remember FDNY Lt. Joseph Cavaleiri, FF Christopher Bopp and Firefighter James Bohan from Ladder 170

Wind Driven Mansion Fire

2 comments
YouTube Preview Image

A million dollar Baltimore County, Maryland  home was destroyed Sunday December 13, 2009  by a fire that tore through the 4,700-square-foot structure with such intensity that firefighters were forced to battle the flames from the exterior. Shortly after 21:00 hours, Baltimore County Fire Dispatch alerted crews for Fire Box 50-2 at 12607 Nancy Lee Court in the Worthington Trace subdivision in the Chestnut Ridge area. As firefighters were responding, dispatch advised they were receiving multiple calls to 911, with some reporting the entire house was on fire. While en route to the scene, Chestnut Ridge Volunteer Fire Company Captain Dan Uddeme reported heavy fire was visible and requested a 2nd alarm and a Tanker Strike Team as the house sits in an area without fire hydrants. Upon arrival, Capt. Uddeme reported fire had consumed the entire 2nd floor and roof area and was spreading. Firefighters were forced to use exterior operations due to the heavy volume of fire. Responding units set up for rural water operations, shuttling more than 17,000 gallons of water from an underground tank on Greenspring Avenue and Walnut Avenue near the scene. Reisterstown Volunteer Fire Companys Engine 412 was also utilized for its Compressed Air Foam System, with several handlines and the ladder pipe from Glyndon Volunteers Truck 404 flowing foam. The Baltimore County Fire Investigation Division is investigating to determine the fires cause and origin. Video and data was obtained from Michael Schwartzberg’s Firepix1075 . Additional photos, HERE and newsreports, HERE

While watching the video, take the time to listen to the wind howling across the mic and observe the intesity level of the fire severity and propogation in the Charlie side. This provides an opportunity for those that are not familiar with the NIST Wind Driven Fire Studies or the PWC (VA) Kyle Wilson LODD to take some time to read about the affects of wind on incident operations, strategies and tactical personnel safety. This was a 4,700 SF large volume residential structure. Think about the performance and your deparment’s capabilities? Remember, it’s not “just” a house fire

Take a look at the Prince William County (VA) Fire & Rescue case study information related to Technician I Kyle Wilson – LODD Report. This event: Technician Kyle Wilson died in the line of duty on April 16, 2007 while performing search and rescue operations at a house fire on Marsh Overlook Drive, located in the Woodbridge area of Prince William County. On that day, Technician Wilson was part of the firefighter staffing on Tower 512 which responded to the house fire that was dispatched at 0603 hours. The Prince William County area was under a high wind advisory as a nor’eastern storm moved through the area. Sustained winds of 25 mph with gusts up to 48 mph were prevalent in the area at the time of the fire dispatch to Marsh Overlook Drive. Initial arriving units reported heavy fire on the exterior of two sides of the single family house and crews suspected that the occupants were still inside the house sleeping because of the early morning hour. A search of the upstairs bedroom commenced for the possible victims. A rapid and catastrophic change of fire and smoke conditions occurred in the interior of the house within minutes of Tower 512’s crew entering the structure. Technician Wilson became trapped and was unable to locate an immediate exit out of the hostile environment. Mayday radio transmissions were made by crews and by Technician Kyle Wilson of the life-threatening situation. Valiant and repeated rescue attempts to locate and remove Technician Wilson were made by the firefighting crews during extreme fire, heat and smoke conditions. Firefighters were forced from the structure as the house began to collapse on them and intense fire, heat and smoke conditions developed. Technician Wilson succumbed to the fire and the cause of death was reported by the medical examiner to be thermal and inhalation injuries.

National Institute of Standards and Technology – NIST Wind Driven Fire Research HERE Smoke and heat spreading through the corridors and the stairs of a building during a fire can limit building occupants’ ability to escape and can limit fire fighters’ ability to rescue them.  Changes in the building’s ventilation or presence of an external wind can increase the energy release of the fire.  This can also increase the spread of fire gases through the building.  In some cases, such as the Cook County Administration Building fire in October 2003, the fire gas flow, into the corridors and the stairway prevented fire fighters from suppressing the fire from inside the structure.  This fire resulted in 6 building occupant fatalities and fire fighter injuries in the stairway.  The Fire Department of New York City has experienced many wind driven fire incidents which have resulted in fire fighter fatalities and injuries.

What tactics or tools are appropriate for use with a wind driven fire and how should the tactics or tools be implemented?  Positive Pressure Ventilation (PPV) is being used by fire departments on smaller structures, such as single family homes, to control the fire flow by introducing pressure from the front door and venting the house through a strategic exit opening.  If done correctly, this tactic can remove significant amounts of heat and smoke from the structure, thus improving the fire fighters’ working environment and improving the chances of survival for the building occupants.  NIST has completed several studies which have a two fold impact: 1) providing guidance on the safe use of PPV and 2) characterizing and validating the modeling of PPV with a computational fluid dynamics (CFD) computer model, so that the model can be used as a training tool for the fire service. Fire Chief Magazine article HERE

  • A video of one of the wind driven fire experiments showing the pulsing flames out of the window. Pulsing Fire(83 MB)
  • A video of one of the wind driven fire experiments showing the deployment of a Wind Control Device (WCD). WCD Deployment. (40 MB)
  • A 4-view video of one of the wind driven fire experiments on the 7th floor. Governor’s Island Wind Driven Fire (368 MB)
  • A 4-view video of one of the wind driven fire experiments conducted where the wind control curtain is deployed. The video is 4 times real time. WDF Curtain Deploy (486 MB)
  • An 8-view video of experiment number five conducted at the Large Fire Building at NIST’s Gaithersburg Campus which examined the impact of a WCD on a wind driven fire.  The video is 4 times real time. Experiment 5-Oct View (450MB)
  • An 8-view video of experiment number eight conducted at the Large Fire Building at NIST’s Gaithersburg Campus which examined the impact of externally applied water, solid stream and fog stream, at 160 gpm.  The video is 4 times real time. Experiment 8- Oct View (419MB)
  • The New Lexicon and Challenges

    3 comments

    Floor TrussOf the many issues affecting the Fire Service, the prevailing challenge that has a pronounced impact on operational safety is the assimilation of engineered structural systems (ESS) into mainstream building design and construction. The presence of engineered structural systems (ESS) are no longer considered to be an innocuous feature in a given building or occupancy; it is the predominate feature in nearly all current construction, renovation and adaptive reuse or infill applications. It has become far more than just concerning ourselves with the presence of a simple light-weight or “engineered” truss roof system or a wood I-beam  floor assembly.

    There is a new lexicon of building construction components and systems that must be added to your operational safety vocabulary and incident action plans. There is a new terminology, applications and a knowledge base to learn that will support operational excellence and support the integrity of incident safety performance of companies and personnel. Do you know what they represent and how these components, assemblies and systems may affect or influence an incident?

    The fire service continues to apply the term “light weight construction” to a wide variety of building construction and systems. This expression has become a miss-application of both term and the correlation of risk and severity related to operational profiling. In other words, we apply and express the use of “light weight construction” for all types of engineered components, systems, designs and assemblies in nearly all types of building construction and occupancy use. Although the roots of the term can be traced back to the early 1980′s, and its application to the (then) emerging use of trussed roofing systems and the advent of wood I-beam floor supports (sans solid dimensional lumber joists), the use of the terminology in today’s context of risk assessment, strategic and tactical management and deployment models and within the context of incident operational tactics is no longer applicable, valid or suitable. It must be expanded into a more specific and descriptive level of classification and correlation.

    For the most part, when discussing buildings and occupancies, aside from classifications related to code type or class as an element of fire resistance; the emphasis has been to differentiate between conventional and engineered construction, and the application of the term “light weight construction”. I continue advocating and promoting through my lectures that it’s much more than this when looking at the spectrum of construction and the structural anatomy of buildings. Current and past generations of buildings, construction and occupancies can be more accurately differentiated and classified within six (6) expanding categories in the following Building Construction Systems;

    ·        Heritage:              Pre-1900
    ·        Legacy:                1900-1949
    ·        Conventional:      1950-1979
    ·        Engineered:         1980-2009     Current into 2010…
    ·        Blended Hybrid:  1995-2009     Current into 2010…
    ·        Enigmatic:            2010-             Projected
     
    We’ll discuss these six classifications in greater details in future postings here and expand the level of details on the CommandSafety.com and Buildingsonfire.com sites. Our current generation of buildings, construction and occupancies are not as predictable as past “conventional” construction, therefore risk assessment, strategies and tactics must change to address the advancement of new rules of combat structural fire engagement. But if you don’t understand or know what and how those changes in predictability have occurred, you may be operating with a false sense of operational risk and safety margin.

    It’s a Lot More than just talking about “Light Weight” Construction….
    ·        From Plywood-CDX….to
    ·        Particle Board- PB…..to;
    ·        Orient Strand Board-OSB
    ·        Structural Composite Lumber- SCL
    ·        Laminate Strand Lumber- LSL
    ·        Laminate Veneer Lumber-LVL
    ·        Structural Insulated Panels-SIP
    ·        Parallel Strand Lumber-PSL
    ·        Machine Stress Rated Lumber- MSR
    ·        Medium Density Fiberboard-MDF and MDL (Lumber)
    ·        Finger Jointed Lumber-FJL
    ·        Adhesives…..
     
    Do some research and check these terms out for starters. We’ll talk more about these components and assemblies in the near future. So get busy on your down time today over the next few days and discover the implications these components may have in your community….

    Here’s a link to a past informative posting related to engineered systems and their relationship to firefighter safety and operations, HERE. There’s some great contributed information and manufacturer “insights” on the subject engineered wood I-joists and beams and firefighter safety. There are some interesting statistical extrapolations, correlations and conveniences’ that attempt to make the case. But then again, You be the judge. Take at look at the presentation developed by the American Forest and Paper Association, HERE and HERE.
     
    If you haven’t done so yet, don’t forget to check out the free online training program on Structural Stability of Engineered Lumber in Fire Conditions at the UL University developed and provided by Underwriter’s Laboratories (UL),  HERE

    Here’s a series of other important Reference Links that provide some insights on operational safety, incident conditions and factors and the lessons-learned from a number of LODD events;  

    NIOSH Publication No. 2009-114: Preventing Deaths and Injuries of Fire Fighters Working Above Fire-Damaged Floors HERE

     NIOSH Publication No. 2005-132: Preventing Injuries and Deaths of Fire Fighters Due to Truss System Failures HERE

    Volunteer Deputy Fire Chief Dies after Falling Through Floor Hole in Residential Structure during Fire Attack—Indiana, HERE

    First-floor collapse during residential basement fire claims the life of two fire fighters (career and volunteer) and injures a career fire fighter captain – New York, Report HERE

    Career Fire Fighter Dies After Falling Through the Floor Fighting a Structure Fire at a Local Residence – Ohio, HERE

    Colerain Township, Ohio Double LODD Preliminary Report, HERE

    Career engineer dies and fire fighter injured after falling through floor while conducting a primary search at a residential structure fire – Wisconsin, HERE

    NFPA Report on Light Weight Construction, HERE

    Informative USFA Coffee Break series postings related to Building Types & Fire Resistance:  HERE. HEREHERE, HERE, and HERE

    Remember, Building Knowledge = Firefighter Safety (Bk-F2S)

    Stop the Entertainment

    2 comments

    3183630397_6104ecd8cd_bWhen we focus our attention on Building Construction, Command Risk Management and Firefighter Safety and the essence of combat structural fires; Structural firefighting is what it’s all about, is it not? The fundamental nature and reason we have such veneration for firefighting and the fire service and all it entails, has a lot to do with going into burning buildings and fighting fire.

    We enjoy it tremendously; we have fun at, because of who we are and what we do-as firefighters. It’s the job and it’s a calling. Firefighting; It’s not something you do, it’s something you are. But firefighting has its adverse consequences, with all too familiar costs, in the form of injuries, debilitating accidents and line of duty deaths.

    As a firefighter; to say that we love firefighting would be an understatement, BUT one issue that we need to address is the fact that there are many individual firefighters, companies and organizations that employ fireground operational practices that promote the “enjoyment and entertainment” of working a good job within the occupancy compartment of a structural fire in the building environment.

    Today’s incident scene and structural fires are unlike those in past decades and will continue to challenge us operationally when confronted with structural fire engagement and combat operations. Operationally, we need to be doing the right thing, for the right reason in the right place to increase our safety and incident survivability. We also can share the belief and understanding that we at times may have found ourselves staying too long in the wrong place, operating tactically in an adverse environment with known hazards that do not have value, for nothing other than the enjoyment of nozzle and operating time in the fire. We have a tendency when working a room and contents, compartment fire or a structural fire in the building environment placing operating companies and personnel in high hazard environments- sometimes at the expense of justifying our own entertainment value in working the job, the assignment or in maintaining the interior operational interface. Think about it.

    We need to stop “entertaining” ourselves. Don’t mistake determined, effective and proactive firefighting with that of reckless, baseless and risk-preferring and self-indulging firefighting. There is a difference. The job is dangerous, it has risks, we are not invincible, and we can die; at any alarm, in any fire, at anytime for any number of reasons…..Let me leave you with some new thoughts and concepts related to operational safety and the definitions that I’ve come to develop that may support apparent or contributing causes to many of the fire service’s undesired events or incidents. Think about the definitions; think about how they apply to you, your personel, your company or your operations; past, present or future. More importantly, think about when and where you’ve found yourself doing any one of these….could the outcome have been different?

    TACTICAL AMUSEMENT  “tak-ti-kəl ə- myüz-mənt”

    1: of or relating to structural fireground tactics: as a (1) a means of amusing or entertaining during fire suppression, support tasks or operations that places personnel at risk

    2: the condition of being amused while engaging in fire suppression, support tasks or operations that places personnel at risk

    3: pleasurable diversion while engaging in fire suppression, support tasks or operations: entertainment; that places personnel at risk
     
    TACTICAL DIVERSION  “tak-ti-kəl də- vər-zhən”

    1: the reckless act or an instance of diverting from an assignment, task, operation or activity while engaging in fire suppression, support tasks or operation for the sake of amusing or entertainment; that places personnel at risk

    2: the reckless act of self determined task operations that diverts or amuses from defined risk assessment and incident action plans; that places personnel at risk
     
    TACTICAL CIRCUMVENTION  “tak-ti-kəl sər-kəm- ven(t)-shən”

    1: to deliberately manage to get around especially by ingenuity or approach that diverts for the purpose of amusing; assignment, operations or tasks that countermand or disregard defined risk assessment and incident action plans; that places personnel at risk

    Worcester’s Legacies

    No comments

    Remembering the Worcester Cold Storage Warehouse Fire 12.03.99

    No comments

     

    WFD 12.03.99

    leadfire

     

    December 3, 2009 marks the 10th anniversary of the Worcester Cold Storage Warehouse fire that resulted in the line of duty death of six courages brother firefighters.

    The Worcester Six;
    Firefighter Paul Brotherton Rescue 1
    Firefighter Jeremiah Lucey Rescue 1
    Lieutenant Thomas Spencer Ladder 2
    Firefighter Timothy Jackson Ladder 2
    Firefighter James Lyons Engine 3
    Firefighter Joseph McGuirk Engine 3

    Overview
    On Friday, December 3, 1999, at 1813 hours, the Worcester, Massachusetts Fire Department dis¬patched Box 1438 for 266 Franklin Street, the Worcester Cold Storage and Warehouse Co. A motor¬ist had spotted smoke coming from the roof while driving on an adjacent elevated highway. The original building was constructed in 1906, contained another 43,000 square feet. Both were 6 stories above grade. The building was known to be abandoned for over 10 years. Due to these and other factors, the responding District Chief ordered a second alarm within 4 minutes of the initial dispatch.

    The first alarm assignment brought 30 firefighters and officers and 7 pieces of apparatus to the scene. The second provided an additional 12 men and 3 trucks as well as a Deputy Chief. Firefighters encountered a light smoke condition throughout the warehouse, and crews found a large fire in the former office area of the second floor. An aggressive interior attack was started within the second floor and ventilation was conducted on the roof. There were no windows or other openings in the warehousing space above the second floor.

    Eleven minutes into the fire, the owner of the abutting Kenmore Diner advised fire operations of two homeless people who might be living in the warehouse. The rescue company, having divided into two crews, started a building search. Some 22 minutes later the rescue crew searching down from the roof became lost in the vast dark spaces of the fifth floor. They were running low on air and called for help. Interior conditions were deteriorating rapidly despite efforts to extinguish the blaze, and visibility was nearly lost on the upper floors.

    Investigators have placed these two firefighters over 150 feet from the only available exit.
    An extensive search was conducted by Worcester Fire crews through the third and fourth alarms. Suppression efforts continued to be ineffective against huge volumes of petroleum based materials, and ultimately two more crews became disoriented on the upper floors and were unable to escape. When the evacuation order was given one hour and forty-five minutes into the event, five firefighters and one officer were missing. None survived.

    A subsequent exterior attack was set up and lasted for over 20 hours utilizing aerial pieces and del¬uge guns from Worcester and neighboring departments. Task force groups from across the State of Massachusetts responded to initial suppression and subsequent recovery efforts. During this time, the four upper floors collapsed onto the second which became known as “the deck”. Over 6 million gallons of water were used during the suppression efforts.

    According to NFPA records, this is the first loss of six firefighters in a structure fire where neither building collapse nor an explosion was a contributing factor to the fatalities. (Excerpt from USFA report )

    Take a moment to reflect on the events of December 3, 1999 and what they may mean to you. Consider your knowledge and understanding of buildings and structures within your district and surrounding response areas. Remember; “Building Knowledge = Firefighter Safety”. For those of you who do not know about this incident, attached is the USFA Incident Report that provides insights into the event and the lessons learned. Also check out the NIOSH Report and numerous archived articles on the web and within various journals.

    Take at look at The Worcester Telegram & Gazette which has an archived webpage; http://www.telegram.com/static/fire/video.html

    HERE ARE THE LESSONS LEARNED FROM THE 1999 USFA REPORT

    1. Abandoned buildings remain a serious threat to the fire service and a danger to the communities in which they stand.
    Fire departments have long recognized the danger of abandoned buildings in their communities, and fires in these structures have to be approached with a certain amount of caution and restraint. If questionable structural integrity, unknown hazardous materials, unusual dangers to firefighters, or other extreme risks exist, the buildings should not be entered. It is paramount that the fire service apply tactical risk assessment in its daily operations.

    Because of the building design, the fire’s magnitude and location could not be ascertained from the exterior, and the Incident Commander had to assess the risks of sending in teams to evaluate the fire and sending in firefighters for suppression. Initial interior reports did not indicate a serious threat to personnel, and operations were conducted accordingly. To assist arriving crews, a placard system should be instituted which clearly defines the risks at an abandoned building. Subsequent to the fire, Worcester Fire put such a system in place. The process has an added benefit of placing firefighters and/or inspectors on locations which might be at risk and where prefire planning should be initiated.

    Risks are not limited to the fire service. Homeless people and drug addicts have been known to inhabit such buildings out of necessity. Ordinary citizens can be impacted by increased crime, and these properties can become a very dangerous playground for inquisitive children. Efforts should be made to renovate or demolish such places even if public funding is not required.

    2. Firefighters must make a concerted effort to know the buildings in their response districts.
    Commercial buildings, by their very nature, pose additional dangers to firefighters, and their familiarity with any given fire building will help to lower these dangers. Company tours are an excellent way to accomplish this goal, and can serve to strengthen the bonds between firefighters and business owners. Such efforts must be conducted with sensitivity, and observed conditions or problems within a business should be conveyed in a helpful rather than confrontational manner.

    3. Fire prevention efforts should be maximized in abandoned and temporarily vacated building to avoid fires in the first place.
    Even temporarily vacated properties can be at risk if utilities like water for a sprinkler system or electricity for an alarm system are disconnected. Although service cessation often occurs when properties are the subject of financial problems it may also take place at the end of a lease or during the sale or renovation of a commercial building. Every effort should be made to forward change of occupancy or use information to first response stations.

    4. Fire departments should continue to grown their file information on buildings in their communities.
    Through the use of mobile computer systems, much information can be forwarded to responding companies and Incident Command during an emergency. Data could include floor plans, occupancies, hazardous materials, water supplies, special hazards, and much more. A system of this type would certainly not be limited to abandoned buildings, but it could be invaluable at such a scene since the probability of an owner showing up is unlikely.

    Although this is laborious process, it may also be a valid use of on duty personnel who can gather information during regular shift time and either forward it to fire prevention or enter it themselves on provided computer terminals. Data could be gathered during in-service inspections and tours.

    5. Delayed reporting allowed the fire growth to exceed the capabilities of aggressive interior attack suppression.
    The exact time of ignition remains an unknown, but it has been established that the fire was burning for a minimum of 25 minutes before smoke was observed venting from the roof. It could have been burning for over an hour and a half. The huge volume of air in the warehouse could supports a large fire without any additional air from the outside.

    Because flames weren’t visible from the exterior, passers-by did not recognize the presence of the fire, and it wasn’t discovered until smoke vented from the roof. Even that was apparently not enough to motivate the hundred of average citizens driving on I-290 that evening to call 9-1-1.

    The trained eyes of public safety professionals were needed to separate this from “the ordinary” and then react appropriately. By this time, however, most of the second floor of B-building was burning, and few barriers were present to prevent further growth.

    The initial report from Ladder 1 on the second floor describes a “room full of fire” in B-building beyond the door in the party wall. This location is some 30 feet from the room or origin, so a one room fire had enough time to engulf the entire floor. A sustained flow of 1000 GPM for 20 minutes had virtually no effect on the fire, and conditions deteriorated around attack crews.

    6. Combustible interior finishes contributed to the rapid fire spread.
    The concept of having 18 inches of combustible materials on the inside of all exterior walls of a building is almost unthinkable to firefighters. The original cork insulation which appears to have been attached with a tar-like substance provided a large volume of fuel, and additional layers of polystyrene and polyurethane with there ferocious burn characteristics gave this fire enormous intensity.

    The area of origin was office space converted from a cold storage area. Under its original design and intent, insulation would only have been placed on exterior walls since the third floor was also cooled. Large amounts of insulation were put into place during the transition and would have included heavy insulation above the suspended ceiling on the underside of the third floor deck. An easily applied insulation would have been sprayed-on polyurethane foam which would have adhered to the wood joists and girders. Once the ceiling tiles were in place, it would not be noticed. The southern wall of the office space would have also required substantial insulation to keep out the cold and to retain the forced hot water heat from the radiators.

    The fire fed on ordinary combustibles during its initial growth, but once the ceiling tiles were breached, flame contacted combustible wire insulation and ceiling insulation. The stubborn flames observed by fire crews and the smoke conditions described on upper floors are consistent with the sustained burning of petroleum based products including rigid polystyrene, polyurethane, tar, and glass board.

    Proper permitting and on going inspections for construction changes within business occupan¬cies can help reduce non-complaint interior finishes.

    7. The fire service should initiate life safety activities early on at a fire scene.
    The concept of a Rapid Intervention Team was known to the Worcester Fire Department and was being implemented before the Worcester Cold Storage Fire, but it was not put into place until the 5th alarm on December 3rd. Firefighters had entered an unknown structure over one hour before the team was assigned. It is now standard procedure in Worcester to assign a RIT at the onset of each structure fire attack.

    The first radio transmission by the Safety Officer was 10 minutes after the RIT was assigned. For control and monitoring of personnel, structural integrity, and other safety concerns, this position should also be filled early on. In an ideal fire scene, the Safety Officer and RIT would be in place before the first firefighters enter the building. Command should strive to have these jobs filled as early as possible even if doing so escalates the event to a higher alarm level to provide sufficient personnel. A system of personnel accountability should be in place. Someone should be tracking who enters the building, the time of entry, and time of exit. Firefighters who are nearing expected times of air exhaustion could then be contacted to ascertain their safety. The establishment of a Safety Officer at the onset of an event can work towards the goal of accountability. The Safety Officer need not be a department officer but could be a chief’s aide or available firefighter familiar with the duties and responsibilities of the assignment.

    8. Large buildings such as warehouses and highrise merit unique search techniques and tools.

    While the standard air bottle for SCBA has a 30 minute capacity, it might be necessary to have available 60 minute bottles for extended search situations and/ or RIT use. Some fire depart¬ments have obtained 60 minute systems for use in confined space rescues or other unusually long events. The 30 minute system has remained the norm in recent years as the necessity of Rehab time has gained prominence, and it would not be advisable to use longer air supplies on a regular basis.

    In high rise incidents, it is common practice to carry in extra SCBA bottles. The same can be done in large space searches. Development of equipment and techniques to change bottles in a hot environment would give extra range to rescuers, and it could prolong their survival should their own rescue be required.

    Long lifelines should be maintained for entry crews in these types of structures as well as marking devises for the interior. These devices include luminescent stickers to show direction, labels to signify searched areas, and other commercially available products. Their effectiveness, how¬ever, depends on their use. And the fire service should incorporate these procedures into more common firegrounds, such as single family houses. The time to try out a new technique is not during a major fire scene.

    For searches involving extended distances, it might be helpful to position secondary search teams part way into a search area. They can wait in reserve in case they are needed, and they can serve as a rescue team for civilians or firefighters.

    Finally, all firefighters who enter a structure must be wearing an SCBA. Worcester Fire has such a policy. Although the facemask and air may not be needed, it must be available. This includes chief officers, aides, and ladder personnel. Even firefighters who are outside structure like apparatus drivers should have SCBA protection available in case of wind shifts or air born particles and debris. With the preponderance of hazardous materials in businesses and residences, SCBA’s use is an essential.

    9. Techniques must be improved to better track the movements of firefighters within a structure.
    Under current technology limitations, Incident Command is essentially limited voice communication/radio to track the movements of firefighters once they enter a building and disappear from sight. IC normally knows where a crew entered and possibly what their destination is, but without good radio reports, the exact movements and locations of crews are uncertain at best.
    Rescue 1’s crew and Engine 3’s Lieutenant both had difficulty communicating their positions which complicated and delayed rescue attempts. Crews continued to search multiple floors in the warehouse because of this uncertainty tying up precious personnel resources and adding more congestion to Stairway 3.

    Despite all lost firefighters wearing integral PASS alarms on their SCBA’s, no surviving firefighters recalled hearing them at any time. The building insulation may have absorbed much of their sound, and the ever present background noise of the fire scene itself may have obscured the rest.

    10. Radio channels are often overloaded at multiple alarm fires, and alternatives must be explored.
    The 800 Mhz trunked radio system used by the Worcester Fire Department had several major failures during this event. Mechanical failure of individual units occurred when the “emergency alert” button on the hand microphone shorted out on contact with water. Fire Alarm repeatedly ordered individual radio operators to shut down, and this took precious air time during an escalating multiple alarm event. In some cases the microphones were detached in the field at which time they functioned normally. Microphones without the alert button were placed on all radios after the conclusion of this fire. During interior operations, there were 1,000 “push-to-talks” registered for the Operations A talk group, the assigned fireground channel.

    Like many progressive fire departments, Worcester has taken steps to insure that all crews enter¬ing a fire building have radio communications. A typical piece of apparatus carries one portable for the officer and one for a second firefighting crew. All members of the Rescue Company carry portables. Having multiple radios is good for safety, but their use requires significant training and discipline. It is all too easy to clog up the air with nonessential transmissions.

    In some events it may even be necessary to use more than one radio and frequency to properly manage the incident. This would require someone to assist the Incident Commander and keep communications in order. If nothing else, a fireground frequency must be adopted by Command and all working units. One possible way to limit talk time would be to have a staging officer communicate with, and pass along assignments to incoming companies on a frequency other than those used for dispatch and fireground command. Once an assignment was initiated, the company would switch over to the fire- ground channel.

    Departments must also choose their radio equipment carefully. The band used must be the best for the standard physical environment in which operations are conducted. Urban departments working inside cement buildings have requirements that contrast greatly with a rural department operating over long geographical distances. If transmission quality continues to suffer, the use of mobile repeaters or other devices might need to be explored.

    11. The use of Thermal Imaging Cameras should be further developed.
    The Thermal Imaging Camera has become a useful rescue and investigative tool for the fire ser¬vice over the past six years. Although early models had some operational problems, the latest versions are reliable and offer more options such as transmission capabilities. It is a device that belongs in every fire department, but its high cost has prevented the purchase by many agencies. Sales volume will hopefully bring down the price of this beneficial tool.

    The camera used at the Worcester fire failed to operate properly, and the manufacturer attributed the problem to thermal overload. This was an early model, and the rescue crew using it was nearly prevented from entering the warehouse by the high heat. Their attempt to enter was one of the last, and no other crews made significant interior progress.

    Under this high heat, the effectiveness of the device is questionable. Thermal imaging devices work well in cooler environments where the body temperature of a victim is higher than the surrounding air or a hot spot within a wall is warmer than the abutting construction. At high heat levels, these cameras will often “white out” because everything in its view is hot enough to affect the imager. If a victim was down in elevated heat, he would absorb the thermal energy of his environment. The turnout gear, for instance, would get hotter and the camera would not be able to differentiate between it and its surrounds. The survivability of a person in high heat for an extended time is negligible.

    NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should

    ensure that inspections of vacant buildings and pre-fire planning are conducted which cover all potential hazards, structural building materials (type and age), and renovations that may be encountered during a fire, so that the Incident Commander will have the necessary structural information to make informed decisions and implement an appropriate plan of attack

    ensure that the incident command system is fully implemented at the fire scene

    ensure that a separate Incident Safety Officer, independent from the Incident Commander, is appointed when activities, size of fire, or need occurs, such as during multiple alarm fires, or responds automatically to pre-designated fires

    ensure that standard operating procedures (SOPs) and equipment are adequate and sufficient to support the volume of radio traffic at multiple-alarm fires

    ensure that Incident Command always maintains close accountability for all personnel at the fire scene

    use guide ropes/tag lines securely attached to permanent objects at entry portals and place high-intensity floodlights at entry portals to assist lost or disoriented fire fighters in emergency escape

    ensure that a Rapid Intervention Team is established and in position upon their arrival at the fire scene

    implement an overall health and safety program such as the one recommended in NFPA 1500, Standard on Fire Department Occupational Safety and Health Program

    consider using a marking system when conducting searches

    identify dangerous vacant buildings by affixing warning placards to entrance doorways or other openings where fire fighters may enter

    ensure that officers enforce and fire fighters follow the mandatory mask rule per administrative guidelines established by the department

    explore the use of thermal imaging cameras to locate lost or downed fire fighters and civilians in fire environments

    In addition,
    manufacturers and research organizations should conduct research into refining existing and developing new technology to track the movement of fire fighters on the fireground.

    http://www.cdc.gov/niosh/fire/reports/face9947.html

    Derelict buildings marked after Mass. LODDs

    Haunting memories spurred Mass. chief to positive action

    Special 10 Year Anniversary Coverage HERE

    21

    Welcome to the new Commandsafety.com

    No comments

    5-9-2009 3-48-53 PM

    Superman, Ironman, Batman, Fireman, Human…We have a tendency- at times to momentarily lapse in recognizing we “Fireman” (and this is related to all gender of firefighters) are Human. Everyday, firefighters throughout America and the world perform extraordinary feats of bravery and heroism, much of it unheralded, unnoticed and underappreciated. It’s part of our job, it’s what we do, after all, we are fireman (firefighters). We know. Our companies know, and more importantly our “families” know; who we are and what we do. We perform the job that we swore an oath to uphold, we learned of the traditions of the service that we came to embrace; we learned our responsibilities, our job and the measures that sometimes need to be taken.

    There has been plenty of banter over the past few months related to the diversity of conventional wisdom related to what a firefighter is made of, the mettle that separate those that choose the virtues of suppression versus those that profess a safer cultural demeanor. We are all firefighters in the truest sense of the word when we choose to wear the badge; to donn our protective equipment and step off the apparatus and into a burning structure in order to undertake the measures and demands required of us; at that moment, at that time and place and under the circumstances that will clearly dictate the path of our destiny, duty, courage, honor and fortitude.

    Do the Job, push the envelope; for the right reasons, for the right cause and the most noblest of circumstances. Do it for the right reasons-BUT don’t do it for the entertainment. Accept personal accountability and responsibility. Understand your limitations.

    Remember, it is about the public we serve AND our “families”.

    Take a moment to listen to the words in the NFFF, EGH program video.

    Think about your accountability, responsibility and safety, while doing The Best Job in the world.
    We are Fireman and yes at times we are Superman, but above all, we are still Human.

    Stay safe to fight that next fire, to answere that next alarm on another day….

    Welcome to the new home of  CommandSafety.com.

    Fortitude & Courage to be Safety Conscious

    No comments

    1-18-2009 1-48-14 PM

    The demands and requirements of modern firefighting will continue to require the placement of personnel within situations and buildings that carry risk, uncertainty and inherent danger. As a result, risk management must become fluid and integrate all personnel. We must manage dynamic risks with a balanced approach of effective assessment, analysis and probability within command decision making that results in safety conscious strategies and tactics.

    You should make time this weekend and slide on over to the United States Fire Administration (USFA) web site HERE. USFA Report HERE. The United States Fire Administration (USFA) released the report Firefighter Fatalities in the United States in 2008.

    An overview of the 118 firefighters that died while on duty in 2008:

    The total breakdown included 66 volunteer, 34 career, and 18 Wildland agency firefighters. There were 5 firefighter fatality incidents where 2 or more firefighters were killed, claiming a total of 18 firefighters’ lives.26 firefighters were killed during activities involving brush, grass or Wildland firefighting, more than twice the number killed the previous year. Activities related to emergency incidents resulted in the deaths of 75 firefighters;

    • 28 firefighters died while engaging in activities at the scene of a fire.
    • 21 firefighters died while responding to, and 3 while returning from, emergency incidents.
    • 12 firefighters died while they were engaged in training activities.
    • 13 firefighters died after the conclusion of their on-duty activity.
    • Heart attacks were the most frequent cause of death for 2008 with 45 firefighter deaths

    Take a look at the issues, the factors and the causes.

    Take the time to think about what you can personally do to make a change, and what your company or agency must do, to support LODD reduction.  Especially for those situations that are in OUR control.

    • Don’t forget about the resources at the Everyone Goes Home Program, HERE.
    • As well as the The Near Miss Reporting System, HERE

    On Any Given day

    No comments

    7-18-2009 3-44-35 AMOn any given day, at any give alarm, the dynamics around us at times may be in or out of our direct control. We may not be able to see what the cards have in store for us, BUT we must ensure we use every fragment of training, fortitude, knowledge, skills, courage, bravery, insights, luck and sometimes (other divine) intervention to get us through. We must have the fortitude and courage to be both safety conscious and measured in the performance of our sworn duties while maintaining the appropriate balance of risk and bravery.

    · The demands and requirements of modern firefighting will continue to require the placement of personnel within situations and buildings that carry risk, uncertainty and inherent danger.
    · As a result, risk management must become fluid and integrate all personnel.

    · We must manage dynamic risks with a balanced approach of effective assessment, analysis and probability within command decision making that results in safety conscious strategies and tactics.

    We don’t know what’s in the cards on any given day, but the citizens we protect can rest assured, we will do our job, as firefighters to the best of our abilities, because of who we are.

    Building Construction & Performance

    No comments

    woodsystems3If you don’t fully understand how a building truly performs or reacts under fire conditions and the variables that can influence its stability and degradation, movement of fire and products of combustion and the resource requirements for fire suppression in terms of staffing, apparatus and required fire flows, then you will be functioning and operating in a reactionary manner.

    This places higher risk to your personnel and lessens the likelihood for effective, efficient and safe operations. You’re just not doing your job effectively and you’re at RISK. These risks can equate into insurmountable operational challenges and could lead to adverse incident outcomes.

    Someone could get hurt, someone could die, it’s that simple, it’s that obvious.