Still and Box for CFD: Near Miss Stairwell Collapse in Chicago

No comments

A fire in a three story multiple family apartment building injured four City of Chicago (IL) firefighters when an interior stairway collapsed during firefighting operations.

The building was constructed in 1927 and consisted of 5456 square feet of space with 3-5 apartment units. Built of masonry wall construction with a wood floor joist system, the fire was reported at 8:43 a.m., in the Type III classified occupancy.

Street View Pre-Fire

The fire began as a basement fire that travelled up two floors, eventually compromising an upper stairway which resulted in compromise and collapsed injuring four Chicago firefighters.

The inherent characteristics of the building and the manner of fire travel and impingement are apparent contributors to the event.

 

Aerial- Alpha; Goggle Maps

CFD Fireground Operations: Photo Tim Olk

 

The four firefighters sustained injures during operations when the internal stairwell connecting the second and third floors gave way.

The mayday was transmitted, and a  211 Plan 1 at approximately 09:00 hrs., seventeen minutes into the operation according to published reports issued by Deputy District Chief Lynda Turner.  Following the mayday and firefighter removals, defensive operations were initiated.

Two of the firefighters sustained smoke inhalation and two firefighters minor injuries, according to Fire Department officials.

Situational Awareness and Operations

No comments

A five -alarm fire on Sunday March 10, 2013 resulted in several firefighters nearly losing their lives, when a resulting backdraft or smoke explosion rapidly occurred during fire suppression operations in a mixed use occupancy building in Harrison, New Jersey.  

Street View: What are the Building Profile Indicators that are obvious to you? Photo screen capture from Google Maps

According to published reports, the rapidly extending fire likely started in the kitchen of a Mexican restaurant on the 600 block of Frank E. Rogers Avenue before it quickly spread and engulfed the entire building, and the adjacent exposure.

Reported information states Investigators have stated this is the second time a fire has broken out in the restaurant.

Reading the Building and Maintaining focused Situational Awareness is Mission Critical. What do you see in this street view and what impact would it have on operations? Google Maps image capture

Fire Department officials have initially classified this as a backdraft as first published in the media. “The unfortunate thing with a back-draft is that initially there’s heavy smoke in the building,” said Captain Robert Gillen of the Harrison Fire Department, “all you need is an entrance of more oxygen and there’s a massive explosion.” Two of the firefighters had more extensive injuries than the other three.

A series of video screen captures has been developed to clearly depict the sequence of events that were apparent as the smoke conditions between the fire building and exposure occupancy rapidly and in a quick succession of seconds went from showing normal fire suppression operational smoke profiling to what would become a backdraft [like] explosion or smoke explosion affecting numerous operating interior and fireground companies.

Sequenced images of rapid changing smoke conditions and resulting explosion: Note there are conflicting interpretations as to this being a Backdraft or Smoke Explosion- Provided by Buildingonfire.com from video capture

The need to maintain concise and focused situational awareness during all phases and stages of fireground operations is imperative to identify conditions when subtle or rapidly changing situations and environments may present an opportunity to communicate and react accordingly.

It’s readily apparent that the rapidness of the smoke changes and pressures that can be seen dramatically sequenced into the explosion stage with little chance to initiate actions.

It should be noted that the brief series of frames in the video can not fully ascetain if this is truly a backdraft explosion or a smoke explosion. There are sublte differences in the intiating fire dynamics and sequence of events interior events.

The importance of understanding the building, the occupancy risk and the manner in which fire and the products of combustion typically travel within similar or unique occupancies and the manner in which commanders and officers monitor and maintain keen situ-awareness.

Recognizing fire behavior indicators and monitoring fire dynamics within the fire compartment and building envelope and the impact of fire suppression actions and intervention and external environmental factors require frequent monitoring and peridic status reports to maintain fluid and continuous assessment of conditions that may influence the conduct of operations.

This event continues to reinforce the need to never allow complacency creep to occur regardless how predictable or unchanging the commonality of the operations are being undertaken or conducted, in similar fashion to past successes in comparable occupancies and structures.

Media Links

Training Links (compiled courtesy of Firefighterclosecalls.com and the Secret List)

 UPDATE

Check out the link and Follow-up discussion from Chief Ed Hartin (link HERE)

Reading the Fire

Before watching the video (or watching it again if you have already seen it), download and print the B-SAHF Worksheet. Using the pre-fire photo (figure 1) and observations during the video, identify key B-SHAF indicators that may have pointed to potential for extreme fire behavior in this incident.

Important! Keep in mind that there is a significant difference between focusing on the B-SAHF indicators in this context and observing them on the fireground. Here you know that an explosion will occur, so we have primed the pump so you can focus (and are not distracted by other activity).

Backdraft or Smoke Explosion

While smoke explosion and backdraft are often confused, there are fairly straightforward differences between these two extreme fire behavior phenomena. A smoke explosion involves ignition of pre-mixed fuel (smoke) and air that is within its flammable range and does not require mixing with air (increased ventilation) for ignition and deflagration. A backdraft on the other hand, requires a higher concentration of fuel that requires mixing with air (increased ventilation) in order for it to ignite and deflagration to occur. While the explanation is simple, it may be considerably more difficult to differentiate these two phenomena on the fireground as both involve explosive combustion.

  1. Did you observe any indicators of potential backdraft prior to the explosion?
  2. Do you think that this was a backdraft?
  3. What leads you to the conclusion that this was or was not a backdraft?
  4. If you do not think this was a backdraft, what might have been the cause of the explosion?

For more information in Backdraft, Smoke Explosion, and other explosive phenomena on the fireground, see:

Worcester FF Brian Carroll recalls the Arlington Street Fire of December 8, 2011

No comments

Firefighter Brian Carroll reflects on the 2011 Arlington Street Fire and Cold Storage Fire of 1999.

Firefighter Brian Carroll was trapped in the basement of 49 Arlington St. after the second-floor of the three-decker collapsed underneath him and his partner on Rescue 1. He thought his close friend was OK. Firefighter Carroll lay trapped and didn’t learn until after he was freed that Firefighter Davies had died.

“What happened to my brother, the three-decker collapsed in a way no one could predict,” Robert Davies said. “Certainly I think it serves as a lesson going forward, and even if it saves one life going forward, then at least something good came out of it.”

Firefighter Davies, who was 43 when he died, has a son, Jon D. Davies Jr., in the department now as a firefighter.

  • From the Worcester Telegram & Gazette;  A cruel month for Worcester firefighters HERE
  • NIOSH REPORT Career Fire Fighter Dies and Another is Injured Following Structure Collapse at a Triple Decker Residential Fire – Massachusetts: HERE

Chicago Fire Department: Everyone Goes Home (official version)

No comments

The Chicago Fire Department: Everyone Goes Home

NFFF News Release: In an effort to  make personal safety a  top priority, the National Fallen Firefighters Foundation (NFFF) and the Chicago Fire Department (CFD) today released a new video, Chicago Fire Department – Everyone  Goes Home®.  Members of the CFD and families of fallen firefighters share their stories in this compelling and moving testimonial of the importance of adhering to safety standards and accepting personal responsibility for following procedures.

Chicago Fire Commissioner Robert Hoff was impressed by a video that the NFFF and the Fire Department of New York produced several years earlier to educate members about the importance of training and safety standards. The FDNY leadership had noticed behavioral improvement among its members following the release of their video. Hoff felt that the members of the CFD could benefit from hearing first-hand accounts of the lessons learned by their colleagues and invited the NFFF to collaborate on a video for Chicago.

“The culture of firefighting requires us to do everything we can to make sound decisions so we can be in a position to help the people we serve when they most need it,” said Ronald J. Siarnicki, executive director of the NFFF. “With this video the firefighters and leadership of the Chicago Fire Department are clearly showing the rest of the fire service you can still be a firefighter and at the same time do your best to make sure Everyone Goes Home®.”

Direct Link: http://www.youtube.com/watch?v=vODww1qwSuE

 

The National Fallen Firefighters Foundation (NFFF) and the Chicago Fire Department (CFD) released a new safety video, Chicago Fire Department – Everyone Goes Home®, to help raise awareness of personal safety in the fire service. Nearly two dozen members of the CFD and survivors of fallen firefighters share their stories.  See the video http://www.youtube.com/watch?v=vODww1qwSuE

The Same Mistakes: Newspaper Reports Common Issues Affecting Fire Operations

No comments

Firefighters rush into a burning commercial building with too-small hoses and insufficient water. The commander can’t reach them because the captain forgot his radio. Backup crews aren’t sure where to go or what to do. Confusion reigns as the building’s truss roof collapses in an explosion of flames.

This reads like the playbook from the deadly Sofa Super Store fire in June 2007, but it’s not. These dangerous missteps occurred at a March 1 blaze on Daniel Island, according to an internal report obtained by The Post and Courier.

photo

Photo by Andy Paras

This blaze at an office building on Daniel Island on March 1 of this year has led to the demotion of a Charleston fire captain and controversy within the ranks.

They occurred despite nearly four years of intensive and expensive efforts to instill a culture of safety in the Charleston Fire Department.

What’s more, the commander in charge that day — a man repeatedly faulted in the in-house review of the blaze — was recently promoted to a top position in the department. And that’s causing some dissension in the ranks.

City fire officials stand behind their promotion of Troy Williams to battalion chief, and they said the portion of the draft report that leaked to the newspaper is incomplete, unfair, unofficial and riddled with inaccuracies.

Fire Chief Thomas Carr acknowledged problems at the fire, which gutted a two-story office building at 899 Island Park Drive. That’s why he authorized a six-member committee of firefighters to conduct what’s known as a critical incident review. But Carr said he rejected the resulting draft report when it landed on his desk six weeks ago because it had errors and failed to live up to its intended purpose, which is to be an educational tool, not an instrument for blame.

The 12-page portion obtained by the The Post Courier newspaper describes “major” violations of policy and assigns blame for those mistakes. It raises questions about the handling of the blaze, the effectiveness of the training firefighters have received and the integrity of the promotion process.

It also highlights the continuing conflict between the department’s hard-charging past and its new, risk-sensitive methods.

  • For the Complete Full version Article: The Post and Courier HERE
  • SConfire HERE
  • Draft Fire Report-Read more: Fire report

Training Download: Commercials- Got Fire? Anticipate Collapse

No comments

Commercials and Collapse Awareness

 

In response to numerous requests from our recent posting; Commercials- Got Fire? Anticipate Collapse briefing post (HERE). We have developed and produced a comprehensive download in PDF format of the entire article that can be used for training, distribution and discussions.

 Click on the image above and download the PDF file and use accordingly  or download HERE

 There are numerous factors to be cognizant of in operations involving commercial buildings and occupancies; with special considerations and a diligent focus on a wide degree of facets on the fireground during combat fire engagement.

You need to start somewhere, thus the investment in these observations and insights for this event. Open your eyes on the fireground, there is so much to take in and respond to; if you know what to look for and can process what you’re seeing.

It is mission critical to comprehend and understand your department’s operational capabilities and the necessary deployment demands for fire suppression, fire flow and phased operations at commercial building fires.

Commercial Fire and Collapse

Respect these buildings for the occupancy risk they present and not the typical occupancy type that we develop our conventional strategies, incident action plans and tactical deployments.

It’s a lot more than that, with far greater consequences; that may be very unforgiving.

 

Commercials- Got Fire; Anticipate Collapse

3 comments

Got Fire?……Anticipate Collapse..

A recent video clip making its way around the cyber fireground clearly depicted a very close-call and resulting near miss event to four firefighters at a four alarm fire involving a commercial building that housed an established insulation manufacturer and installation contractor.

The video shows within a very compressed time frame, the progression of rapidly deteriorating interior conditions, the adverse affects on the building’s structural systems and the results from the loss of load transfers that lead to a catastrophic wall collapse  narrowly missing the crew of firefighters who were operating a hand line in the vicinity of an exterior overhead door. Fortunately the injuries sustained to the firefighters were minor in nature; however the consequences and results from this collapse could have been far different and significantly more severe.

Following a series of repeated viewings of the video clip and with each successive viewing, it became readily apparent that there was a lot more to these images of the collapse and the cursory focus on the resulting near miss event. Closer examination of the video clip and the still frames brought to light some obvious conditions and indicators that easily become lost in the rapidity of the sequence of the collapse; which really has the true story to be told.

It’s the mechanism and sequence of the collapse, the dynamics of the building’s performance and the building indicators that provide a training opportunity in further examining key factors, presenting insights that could be a focus for operational and command personnel at future incidents with common parameters and gaining some mental models in recognition-primed decision making that contribute to the naturalistic decision-making process.

If you know what to be looking for, then when you see it, you may be able to anticipate, project and implement in rapid succession appropriate measures dictated by the incident.

Four Alarm Commercial Building Fire with Collapse: Fire Photo by Ben Goldberry

 

In an effort to promote additional insights and bring forward these fundamental observations and experienced-based presumptions extended from these and other news video images, still photographs, additional reporting research and examination, and a review of other published media resources; the following observations presented in this overview brief are being conveyed to increase firefighter, company and command level awareness of key collapse indicators such as those present at this commercial fire  and to further the concept of adaptive fireground management principles and increase awareness of fundamental building performance indicators and principles to help you increase your intuitive observations skills and translate them into proactive operational actions on the fireground-before an adverse condition occurs.[ i.e., being five steps ahead of the fire conditions].

Although this briefing makes use of the images and conditions depicted in the video clip and encountered by the fire department evident in the images; the susequent commentary and  insights provided are not meant to provide  direct or indirect opinions, renderings, criticism or censure  towards the conduct of operations or the management of the incident by the respective department and it’s firefighting, command and support personnel who operated at the actual fire and experienced this near miss event first-hand.

We are grateful that the events of this alarm precluded anything worst occurring given the potential seriousness of the prevailing  incident conditions and commend the  fire department and it’s firefighters that provide these exceptional services each and every day to the citizens they serve and to the community they protect, in mitigating this serious fire; safely and successfully.

This incident and the resulting near-miss captured by the videographer provides the Fire Service with an exceptional opportunity given today’s far reaching capabilities of eMedia, this web site and direct and indirect readers, links, tweets, likes, reposting’s, uploads, downloads and sharing  an opportunity to share the consequences of an extreme close-call and learn from it in a positive and constructive manner, so that firefighters, company officers, commanders and support personnel can better predict with knowledge, insight and at times intuition a better understanding of buildings and the structures and occupancies we operate within on the fireground.  

There are numerous inherent indicators present at every incident scene we operate at that. As is in this near miss event and building collapse; it’s sometimes the subtle things that need to gain the attention of operationg companies and personnel and the ability to rapidly process, recognize and react.

 Remember this: Building Knowledge = Firefighter Safety.

As a generality; it’s important to note that given heavy fire involvement in a structure (got fire), adaptive fireground management considerations would promote conservative considerations to anticipate and expect collapse (degraded or compromise; limited or catastrophic).

In the case of fires in commercial occupancies and buildings with;

  • Large Square footage/Floor areas
  • Significant fire loads
  • Large open structural system spans lacking compartmentation, 
  • Unprotected steel components and assemblies 
  • No Sprinkler Systems
  • Omitted, compromised or degraded passive or active protective  or suppression systems
  • Significant openings along the exterior building envelope
  • Significant opening on the roof enclosure
  • Deep seated fires or rapidly escalating and extending fires

It is mission critical to comprehend and understand your department’s operational capabilities and the necessary deployment demands for fire suppression, fire flow and phased operations. 

Respect these buildings for the occupancy risk they present and not the typical occupancy type that we develop our strategies, incident action plans and tactical deployments. Its alot more than that, with far greater consequences that may be very unforgiving.

 

Aerial Plan of Building and Collapse Area A-B

 

The Building

The fire incident involved a single story commercial building occupying approximately 32, 200 square feet of area on a multiple building site with proximal exposures.  Manufacturing, warehousing and offices comprised the building’s operational use.  An aerial plan view shows the geographical building scene divisions and the location and relationship of the Alpha- Bravo Side collapse zones that affected operations and resulted in the close-call and firefighter near-miss. The proximity of exposures, physical layout and orientation can be further assessed.

 

 A review of public documents and records, incident reports and various media resources  provided the following insights;

Overview Details

 

 

Alpha Street Side View- Adapted from Google Streetmaps

 

The view of the alpha street side identifies the building front facade, its main office entrance (center between dual overhead doors on the left and right). Pronounced on the alpha side facade is the presence of four (4) equally spaced overhead (OH) doors that provide direct access into the building’s interior. The subsequent collapse area is depicted at the A-B corner with special attention drawn to relationship of the wall plane and OH door proximity.

The relationship and this wall surface ( area square footage) and the presence of the OH door opening to the wall/ roof interface area that subsequently became compromised and collapsed is critical in further understanding the mechanism of the collapse sequence and also the positive effect it had on the survivability of the firefighters who were within the collapse zone at the time of the wall failure.

Don’t Always Stress the Corners

It’s been a common practice and fundamental fireground consideration to define the corner of a typical building as having safety considerations and prominence in the context of ladder company operations, laddering and roof work and in the placement of personnel and positioning of fireground operations.

Corner Building Operational considerations have included, but limited to;

  • Provides a potentially safe(er) area of operational refuge
  • Provides a location to safely position ground ladders for roof access/egress
  • Provides a location that has a potential  higher degree of assurance for maintaining structural integrity in the event of a collapse condition of an outer wall
  • Will not fail in a catastrophic or monolithic manner due to the postulated presence of structural members on the vicinity of either the wall enclosure and/or the roofing structural system and assemblies
  • The design and construction configuration and orientation of the ninety degree angle of the building’s outer wall envelope (at the corner)  provides predicated inherent structural stability
  • The  typical type of structural or envelope construction may have a resulting  ninety degree building corner having a more robust resistance to collapse and compromise due to the various types of enclosure systems (methods and materials) and assemblies and needed stability per engineering principles

In this instance (as shown in the Alpha side street view),  the presence of the large overhead door in close proximity to the corner wall intersection and transition ( A-B side), actually makes this position, fireground proximity and travel paths highly prone to early and complete collapse potential in the event of a loss of the wall-roof component or assembly integrity or in the load bearing/transfer capabilities of the wall-roof assembly. 

  • The presence and identification of a corner configuration similar to this in a commercial structure should result in a higher degree of considerations and risk assessment when formulation and deploying operational assignments and in the placement of personnel for task assignments in this proximity.
  • This operational area should be considered as a candidate for designation as a collapse zone based upon projected or defined operational considerations, incident conditions and predictive building characteristics, systems, materials and fire dynamics and conditions.  

 

Alpha-Bravo Corner of Subsequent Collapse Aerial View

 
 
The view  from the Alpha-Bravo Corner shows the collapse zones at grade and the affected area size.
 
As noted in the preceding narrative, the presence of the overhead door opening along the perimeter wall enclosure and outer envelope creates a risk area that would require monitoring, periodic reconnaissance and assessment during subsequent operations to determine structural stability and potential adverse conditions.  
 
The proximity of the opening in relationship to the corner wall, roof support and structural span of the opening results in a very delicate balance of forces, loads, reliance and dependence that must be maintained for structural integrity and equilibrium. 
 
  • The entire perimeter of the alpha side could be considered for a restricted collapse zone just in terms of wall opening alone sans the degree of actual or projected interior fire impingement or fire involvement.
 
Take some time to view the video clip a few times over before proceeding to the next sequence of fame images.
 
This videographer of this video was Aaron Dohring. (all rights reserved)

 

 

 

 Aerial Overhead view of the building perimeter walls along the four divisions ( A-D) with the A-B corner that subsequently experienced the wall-roof compromise and resulting collapse.

 

 The A-B corner and the affected ground areas around the collapse zone. Considerations for a collapse zone area on the A-B corner would have resulted in a minimum distance of twenty five (25) feet from the building base for all operations within this area. The collapse zone on the Bravo side extends into the exposure building due to its close proximity.

Always consider the building envelope materials of construction and systems present on the building. The use of concrete masonry units (CMU) is common, as is the use of pre-cast concrete and cast-in place and tilt-up concrete construction panels.

Variations in collapse dynamics and mechanisms of collapse may result in sizable increases in collapse zone distances from the building base with consideration for monolithic or partial wall collapse as well as safety considerations for bounce and travel over long distances of modular assembly building pieces ( i.e. concrete blocks, brick venner or material chunks).

We have not discussed collapse considerations for other building envelope systems such as metal panelized systems since these have entirely different collapse considerations and profiling, not applicable to this incident and assessment insights. The same is true when considering operating and collapse considerations at commercial buildings with ordinary construction or heavy timber systems (Type or Class III and IV). These to have different rules of predictive building performance and collapse safety considerations.

 

Typical Interior

 
 
The interior of the building included  unprotected steel components and assemblies consisting of steel columns, beams and open web steel joists. These common and conventional structural support systems provided large free clear spans, common for typical warehouse and commercial occupancies. The presence and operability of  functional fire suppression sprinkler system coupled with passive and active protective devices and compartmentation can help support proactive and aggressive fire suppression efforts in those conditions that have appropriate risk determinations and balanced risk-gain benefits.
 
The presence of unprotected steel components ( Truss, column, structural beams etc. ) and assemblies requires an understanding of the effects of flame and heat impingement,  rate of heat release and fire dynamics, potential for movement and displacement of structural components and effect on assemblies, systems and connections and the effect on structural stability, integrity and building load transfers and displacement that all can adversely affect building performance, integrity and collapse potential  
 
 

Typical Structural System and Components

 
 
 

Interior View with Steel Columns, Open Web Steel bar Joists and Beams

 
 

Typical Open Web Steel Bar Joists w Metal Roof Deck

 

 
Large clear spans provided by the open web steel bar joists allowed for considerable free floor space typical of commercial warehouse occupancies.
Note the use of what appears to be combustible wood storage and staging areas that could have could potentially contribute towards increased fire intensity, extension and further contribute towards adverse affects on the unprotected structural steel components and assemblies.
 

Alpha Side Collapse Area Details: OH Door Pre-Collapse Insights

 
 
 

Pre-Collapse Operations on Alpha side with personnel in close proximty to the building perimeter

 

Pre-Collapse view of Operations on the Alpha side with personnel in close proximity, (within [a] collapse zone) to the building perimeter. It is evident that the degree of interior fire extension and involvement presumes a cautious deployment and placement of personnel in safe operational areas. When operating in such close proximity to the building wall and envelope, it becomes increasingly challenging for company officers and company personnel to monitor overall building performance indicators that may be prevalent or dominant from a view point further away from the building. 

Fire extension, smoke conditions, component or assembly movement or displacement may be readily defined and identified from a vantage point away from the building, requiring additional independent  operational assignments within the division if resources allow.   Otherwise, officers are encouraged to get a big picture view and increase their span of vision of the building and progressing fire conditions and building performance

 
 
 
 

The pre-collapse frame image above identifies the building roof line in relationship to the ground operations, smoke conditions and also the directional flow of the elevated master stream [upper right corner]. The initial  stage of the wall compromise and collapse can be seen in the Bravo wall pulling away. When watching the video, pay close attention first to the stream direction and flow and them at the location and movement of the wall, which is followed in rapid succession with the full wall collapse.

T

 

Close examination of the initial video frames shows the rapid displacement of the portion of the Bravo wall and outward collapse towards the B-Exposure (alleyway) Refer to the Aerial Plan for orientation. The A-B Collapse is progressing from the Bravo side to the Alpha side as loads are being transferred in rapid progression with further collapse expected.

The frame image above shows the bravo wall failing outward with the resulting loss in structural support of the roofing deck assembly.

Rapid fire migration and extension is evident after the wall section collapse with increased flames visible. In the video, one firefighter quickly recognizes the imminent collapse and reacts.

A significant section of wall area is present at the A-B side and progressing from the building corner to the left jamb of the overhead (OH) door. This area and the area directly above the OH door opening is calculated to weigh over 20,000 lbs. 

The early identification and establishment of collapse zone(s) is mission critical especially at commercial buildings due to the considerations for rapidly changing operational conditions that may be a result of or influenced by the following;

  • lack of knowledge or understanding of the building’s construction, systems and characteristics
  • lack of adequate resources, skills and or capabilities for selected phase operations
  • fire loading, combustibles, flammables and other products
  • Last of or loss of compartmentation
  • fire and protective systems failures or inoperability
  • unapproved alterations, additions and renovations to the building, systems and occupancy
  • transitions for offensive to defensive operational phases, which at times may results in operating position postures too close to the building
  • failure to recognize situational factors that will drive appropriate operational phasing and task deployments
  • lack of building performance knowledge
  • not considering occupancy risk versus treating the building/fire relationship based upon occupancy type
  • not recognizing key collapse indicators and failing to implement timely actions [proactively versus reactionary]
  • being four steps behind the fire conditions evident instead of implementing adaptive fire ground management insights [five steps ahead of the evident fire]
  • use precise coordination when placing elevated masterstreams into operations with ground personnel operating within close quarters
  • understand the effects of master streams on the integrity of building features, assemblies and components

 

 
 
 
 
The image frame above shows personnel operating within an imminent collapse zone directing hand lines into the interior fire area. Further examination of the video  frames clearly shows one firefighter quickly recognizing that a collapse is occurring and attempts to alert the other personnel to retreat. Simultaneously to the collapse progression, the crew immediately retreats away from the collapsing wall and falling building materials.
 
Within the span of four seconds, the wall compromise occurs and collapses on the ground at the A-B corner and immediate area on the alpha side.  The slightly monolithic manner in which the wall plane first peels away and progressively collapsed is interesting for a CMU wall. Possibly due to the outward collapse of the Bravo wall, followed by the rapid succession of failure of the roof-wall connection interface resulted in an transitional downward force that pushed the alpha side wall outward allowing gravity to work its force
 
When operating in close proximity to a heavily involved forward interior condition [exterior position] it is important to maintain focused situational awareness and either directly maintain or delegate responsibilities for observations of fire and smoke progress and conditions while monitoring key functional building performance indicators and collapse pre-cursors. 
 
Additionally, always re-evaluate the effectiveness of deployed and operational hose lines, streams and in water application to ensure they are adequate for the degree of fire suppression being undertaken and the corresponding fire flow requirements. Don’t just assume, determine with validity. [ Refer to Tactical Entertainment]  
 
Obscured by the rapidly defining smoke which is a result of the developing and extending collapse, the frame image 04 below depicts the beginning of the compromise and collapse sequence commencing as a result of the Bravo wall compromise and collapse sequence at the B-A corner that will subsequently peel towards the Alpha side and continue up to the outermost jamb of the overhead door.
 
Pay particular attention to the first three to four seconds of the video clip and review the video clip over a few times;  looking at the operating elevated master stream that is clearly visible and operating from the upper right part of the screen through the smoke plume; follow the direct orientation and stream flowing directly towards the bravo wall plane,  and presumed penetrating into/through the roof deck or impacting through the metal roof deck and wall-roof assembly area at the upper roof edge.
 
 

Image 04

 
 Frame image 04 depicts the rapidly deteriorating conditions that are evident as the collapse sequence continues and the overhead door jamb (left) buckling and adjacent wall failing by way of an outward curl or peel away commencing from the upper (left image) A-B corner at the roof line and then peeling and failing from upper left to right.
 
 

Image 05

 
 
The leading edge of the outward collapsing wall plane ( yellow dotted line) is failing with the greatest material concentration occurring at the A-B edge outward. Fortunately the presence and location of the overhead door opening  lessened the amount and location of wall material ( concrete masonry units-CMU) and contributed to a void area being present and not fully impacting the firefighters who were operating within this collapse zone.
 
In other words, had this been a solid full wall collapse likelihood for significant firefighter injury would have resulted. 
 
The affects of wall/roof compromise should be of focused consideration and monitoring when managing incidents of this size and magnitude in similar occupancies and building features.  Flame and heat  impingment can and will affect the structural integrity of lintels spans, beams and truss connects along roof lines and connections. Look for signs of impingment, degradation or compromise. watch for signs of probable inward/outward or curtain wall collapse.
 
 
 

Image 06

 

The remaining images, frames 06 and 07 depict the location of the firefighters to the wall collapse, the relationship to the wall and roof system and the degree of wall area that became compromised and collapsed.

 

Image 07

 

This brief video clip and these accompanying briefing insights provided a tremendous opportunity to examine in a non-critical manner an actual near miss collapse event and  operational discernments that provide a focused training an awareness opportunity.

When given the time to analyze and assess, some things become so apparent and self-revealing that we might prematurely say why didn’t someone pick up that or those conditions while conducting operations at [an] incident.  It is dependent on a wide variety of factors, conditions and parameters that are difficult at times to identify and harder yet to fully identify as common or contributing factors, errors or omissions.

It’s not always that easy; but contradictory – some time it really is (or should be) that easy.

Some things on the fireground may not be prone to being so readily identifiable or recognized.

It all depends what you’re looking for and whether you have the necessary insights, knowledge and skill sets. Incident priorities, demands, situational focus, awareness or disconnect all may have a part in how and incident is managed and mitigated.

It goes back directly on knowing what to look for and when; at what type of building with which type of occupancy and under what stage or stages of fire development and combat operations or engagement you might be in. It complex, it takes time and experience and learning’s.

There are numerous factors to be cognizant of in operations involving commercial buildings and occupancies; with special considerations and a diligent focus on a wide degree of facets on the fireground during combat fire engagement.

You need to start somewhere, thus the investment in these observations and insights for this event. Open your eyes on the fireground, there is so much to take in and respond to; if you know what to look for and can process what you’re seeing.

It is mission critical to comprehend and understand your department’s operational capabilities and the necessary deployment demands for fire suppression, fire flow and phased operations. Respect these buildings for the occupancy risk they present and not the typical occupancy type that we develop our conventional strategies, incident action plans and tactical deployments. It’s a lot more than that, with far greater consequences; that may be very unforgiving.

Links:

 

Size-Up: Report of the Week (ROTW)

No comments

 

Size-Up and Risk Assessment Skills: How are yours?

 

In this week’s issue of the National Fire Fighter’s Near-Miss Reporting System’s Report of the Week (ROTW) an informative focus was provided on near-miss reports related to Size-Up. We’re posting the ROTW alert in it’s entirety below.

Go over to the National Fire Fighter’s Near-Miss Reporting System and check out the resources and subcribe to the weekly ROTW today.

Sizing up a structure for a fire attack is a skill that takes time, practice and experience to fully develop. When the first arriving (and any other arriving) officer surveys the structure, the process needs to be rapid and thorough. In some cases, if the size-up is too rapid, critical points can be overlooked. This oversight can result in unintended consequences for the initial attack team.

As seen in ROTW 11-216, it is worthwhile to take an extra minute to process the situation prior to attack.

“We were dispatched to an attic fire in a single-family home. Initial arrival was an on duty engine and ladder truck with two firefighters and one officer, who gave an on scene report of a two-story wood frame residential structure with heavy smoke showing from the rear…After seeing three sides of the building, the officer (myself) ran around to back side and found heavy flames venting from the second floor gable end off the rear of the structure. At the time it was not known if this area was an attic over a first floor addition or a room on the second floor. The officer decided a quick interior search and fire attack, pushing the fire out the already vented hole, would be the initial strategy…After searching the first floor and finding no stairs, the initial team exited the first floor and went to the rear of the structure where an exterior stairwell was found to the second floor. On initial size-up, the stairwell and two mailboxes on the house were missed, causing approximately a one minute delay to fire attack…Upon entry to the second floor, conditions were a light haze with complete visibility of the occupied area…A small pike pole was used to breach the wall while the nozzleman stood ready and the third firefighter moved hose. After an area between the studs and about two feet tall was opened, the attack line was discharged. Conditions went from almost clear to black and steamy instantly. After spraying the nozzle for less than 30 seconds (maybe even sooner) the room became too hot to occupy. All three of us announced we had to get out, almost at the same time…”

Reading the structure is as important as reading the smoke and fire conditions prior to mounting an interior attack. Aesthetics can play a large role in the building design, and what appears to be structural may truly not be safe to load. As 11-216 illustrates, the fire blowing from an upper floor window may not be as visible on the inside as it is on the outside. Once you have read the entire account of 11-216, and the related reports, consider the following:

  1. The report notes that, “…exterior stairwell and two mailboxes on the house were missed”. What situational loss factor would best describe why that occurred? Go to our Facebook Page and record your answer and the reason why you selected the factor.   
    • a. Distraction
    • b. Fixation  
    • c. Overload
  2. What fire behavior phenomenon occurred when the crew opened the interior wall and experienced conditions that went from “clear to black”?
  3. If you were dispatched for fire in the attic and arrive to find heavy smoke and fire showing, what attack line would you select and why?
  4. Based solely on the information provided in 11-216, would a two out be necessary before the interior attack could commence?
  5. The reporter states “heavy smoke” was observed. Jot down a few factors that mean “heavy smoke” to you. Discuss what you wrote down with your colleagues. 

The time pressure to go into action when we arrive at a working fire will often cause the size-up to be hurried. Remembering the lessons learned from 11-216 will make your next size-up more complete. The NMRS staff expressed thier thanks to the lieutenant from Region V for sharing what was learned.

 

Related Reports- Topical Relation: Size-up    

Have you avoided a disaster because of a good size-up? Submit your report to www.firefighternearmiss.com today to pass on your experience.

Realize that the resource center and the near-miss reports are all formulative and can very easily support training drill development, just in time training, table-top discussions, scenario based exercises and review discussions with company, staff or command officers and all station or company personnel.NMRS Resource Section, HERE
 
Links:  
 
Near-Miss Reporting Form example, HERE
  • NFFNMRS Facebook Page, HERE
  • Past Report of the Week Library, HERE
  • 2011 Calendar and Annual Report, HERE

 

Got a Near-Miss Report to Submit? Click on the button for a direct link to the NFNMRS here

 Don’t forget to go to the National Firefighter Near Miss Reporting System for  number of exceptional training aids, resources, PPT and more. NFFNMRS, HERE

Fireground Dynamics: Smoke Explosion during Interior Operations

No comments

 

 

 Three Franklin (OH) firefighters were caught in what has been determined to be a smoke explosion at a structure fire involving a restaurant occupancy in what appears to be a building of Type III construction that published reports indicated was built in 1892.

Franklin (OH) FD Lt. Kyle Lovelace and firefighters Quincy Pearson and Brad Brown were caught in a smoke explosion while conducting interior fire suppression operations at which time conditions deteriorated and a smoke explosion occurred. Simultaneous with the recognition that something was not good; the crew immediately began to retreat when they were caught in the explosion. All of them luckily made it out unscathed.

According to published reports, “They reverted back to their training and did what they needed to do to get out,” according to Fire Chief Jonathan Westendorf . “We have a flashover simulator and we spend a good amount time talking about it each year.”

Reports have indicated Lt. Lovelace stated that when they arrived on the scene, he noticed smoke coming from left side of the building above the second floor and thought that it may be an attic fire.

They attempted to gain entry through the front door, but before they opened it they noticed a crack in the window and decided to gain entry through the rear. Lt. Lovelace, FF Pearson and FF Brown entered an alley covered by an awning connecting to freestanding structures. Westendorf  later said his guys were fortunate to be in that location because they were isolated from the brunt of the blast.

The crew advanced about 25 feet when FF Pearson, who was on the nozzle, saw wisps of smoke and began to feel extreme heat.

Lt. Lovelace used a thermal imaging camera to locate where the heat was coming from, but right before he could tell Person, he started yelling at him to get out. They made it about 20 feet when the thick black smoke started banking down on them. As Lovelace exited under the awning, conditions quickly worsened and the smoke explosion occurred. Video of blast HERE

Links for complete reporting insights and details;

 

Photo by Nick Graham Middletown Journal

Middletown Journal Photo Show from the Fireground, HERE
 

Alpha side from the Street, Image Capture from Google Street Maps

 

 

Aerial Image along South Main Street of the Building

 

 

Screenshot from video as smoke explosion occurs

 

 

Video: Caught On Camera: Backdraft Explosion At Franklin Fire

Remembrance: FDNY and Buffalo(NY) Double LODD from Floor Collapse

1 comment

 

Dangers of Floor Collapse

Take the time to revisit two Firefighter LODD incidents that both occurred in the month of August in 2006 and 2009 respectively. Excerpts from the NIOSH Reports have been included that are part of the NIOSH FIRE FIGHTER FATALITY INVESTIGATION AND PREVENTION PROGRAM (HERE).

Both of these incidents involved a double firefighter line-of-duty death (LODD) and resulted from a floor collapse during the conduct of operations within the fire involved structures. There are numerous lessons learned and recommendations that can be considered and applied in organizations and agencies across the country, both large and small; career or volunteer.

These incidents bring to light the occupancy risks present in some of our most common of building occupancies, and continue to provide the basis for operational considerations and management based upon occupancy risk versus occupancy type. There are numerous operational considerations when addressing fires located in basement or underdeck areas and the subsequent management of those incidents based upon known or assumed building characteristics, occupancy risk and profile, inherent or presumed building stability and potential for structural compromise and the operational risk from isolated or catastrophic of collapse.

  • Buffalo (NY) Fire Department: August 24, 2009
  • FDNY: August 27, 2006

Some Other Links related to Floor Collapses and Reference Links for Operational Insights and Operating Experience (OE)

Here are some Safety Considerations related to Residential Occupancies (non-inclusive) for Operations at Basement Fires that will support fireground operational safety:

  • Conduct a thorough fire size-up and communicate the findings to all personnel on-scene before entering the building.
  • Conduct an assessment of the Building Profile ( building construction type, structural assembly systems and features and age) and assesss fire behavior and intensity levels.
  • Ensure an adequte Risk Assessement is conducted and that Risk versus Gain is determined
  • Maintain situational awareness throughout the tactical deployment of crews within the interior of the structure
  • Conduct a 360 degree perimeter assesement when feasible to determine access and egress points, fire location and travel and other mission critical operational perameters.
  • Incident commanders and company officers should be trained and experienced in structure fire size up to avoid putting fire fighters at unneeded risk of working above fire-damaged floors.
  • Do not enter a structure, room, or area when fire is suspected to be directly beneath the floor or area where fire fighters would be operating, or if the location of the fire is unknown.
  • Never assume structural safety of any floor (regardless of the construction) having a significant fire under it.
  • Conduct pre-incident planning inspections during the construction phase to identify the type of floor construction.
  • If pre-planning is not conducted, assume residential construction and small commercial buildings built since the early 1990s may contain engineered wood I-joists.
  • Report construction deficiencies noted during preplanning to local building code officials. For example, engineered wood floor joists should only be modified per manufacturer specifications—usually limited to cutting to length and removing pre–cut knockouts for utility access. Report damaged or cut chords or webs to building officials.
  • Develop, enforce, and follow standard operating procedures (SOPs) on how to size up and combat fires safely in buildings of all construction types. Rapid intervention teams (RIT) should include a portable ladder with their RIT equipment when deployed at basement fires.
  • Ensure Time Compression is considered: Ensure Command has the ability to monitor progress or elapsed incident time and adjusts strategic and tactical plans accordingly and in a time effective manner. 
  • Provide training on identifying signs of weakened floor systems (soft or spongy feel, heat transmitted through floor, downward bowing, etc.).
  • Make fire fighters aware that all floor types can fail with little or no warning.
  • Use a thermal imaging camera to help locate fires burning below or within floor systems, but recognize that the camera cannot be relied upon to assess the strength or safety of the floor. (Refer to the recent UL Test Data and Operational Safety Considerations ”Structural Stability of Engineered Lumber in Fire Conditions” available at http://www.uluniversity.us/ )
  • Fire fighters should be trained on the use of thermal imaging cameras, including limitations and difficulties in detecting fire burning below floor systems. (See reference to UL above)
  • Immediately evacuate and, if possible, use alternate exit routes when floor systems directly beneath the floor where fire fighters would be operating are weakened by fire.
  • Use defensive overhaul procedures after fire extinguishment in structures containing fire-damaged floor systems of all types.
  • Consider becoming active in the building code process and influence requirements for fire resistance of floor and ceiling systems to further fire fighter safety and health.
  • Ensure RIT personnel area staged and have complete a site assessment of the building and occupany upon thier arrival and set-up
  • Ensure that a rapid intervention team (RIT) is on the scene as part of the first alarm and in position to provide immediate assistance prior to crews entering a hazardous environment
  • 

REMEMBRANCE  

Buffalo (NY) Fire Deparment- August 24, 2009  1815 Genesee Street, Buffalo, NY 

Career Lieutenant Dies Following Floor Collapse into Basement Fire and a Career Fire Fighter Dies Attempting to Rescue the Career Lieutenant – New York (REPORT HERE)

The Structure, (pre-fire conditions)

SUMMARY

On August 24, 2009, a 45-year-old male career lieutenant (Victim #1) died following a partial floor collapse into a basement fire, and a 34-year-old male career fire fighter (Victim #2) was fatally injured while attempting to rescue Victim #1. The career fire department was dispatched for “an alarm of fire” with reported civilian(s) entrapment. Arriving units discovered a heavily secured mixed commercial/residential structure with smoke showing. Following failed initial attempts to locate an entry to the basement, crews located a door on Side 2 that provided access down a flight of stairs to a basement entry door. Repeated attempts were made to force open this basement door in order to search for trapped civilians, but crews had difficulty gaining access through this door because it was made of steel and locked and dead-bolted on both sides. Other crews on scene performed primary searches of the 1st and 2nd floors with no civilians found.

Approximately 30 minutes into the basement fire, command ordered all interior crews to exit the structure to regroup because crews were still unable to gain access into the basement from Side 2. Additional manpower was sent with special tools to assist in breaching the basement door on Side 2. Victim #1 and two fire fighters from his crew entered into the structure from Side 1 to verify all fire fighters had exited a 1st floor deli. Victim #1, following a hoseline into the structure, was well ahead of the other two fire fighters when the 1st floor partially collapsed beneath him. Victim #1 fell with the floor into the basement, exposing him to the basement fire. The other two fire fighters immediately exited the deli after fire conditions quickly changed and shelving and displays fell on them; they were unaware of what had just occurred. Victim #1 made several Mayday calls from within the structure and activated his PASS device. Confusion erupted exteriorly on scene when trying to verify who was calling the Mayday, their exact location, and how they got into the basement. The incident commander was aware that he had crews attempting to gain access into the basement from Side 2 but was unaware that there had been a floor collapse within the deli section of the structure.

Simultaneously, Victim #2, a member of the fire fighter assistance and search team (FAST), was standing by outside Victim #1’s point of entry when the Mayday calls came out. It is believed that Victim #2 knew where Victim #1 was since he had gone in the structure with him earlier in the incident. Victim #2 grabbed a tool, went on air, and rushed into the structure. The FAST and additional personnel on scene concentrated on Side 2 initially while other fire fighters followed an unmanned hoseline into the deli. Crews within the deli quickly discovered a floor collapse and reported hearing a PASS device alarming. Victim #1 was immediately identified as missing during the first accountability check, but Victim #2 was not accounted for as missing until the third accountability check, more than 50 minutes after Victim #1’s Mayday. After the fire was controlled, both victims were discovered side-by-side in the basement where the 1st floor had partially collapsed. They were found without their facepieces on and with SCBA bottles empty. Victim #1’s PASS device was still alarming. They were pronounced dead on scene. Four fire fighters and one lieutenant suffered minor injuries during the incident. No civilians were discovered within the structure.

F2009-23 Aug 24, 2009 Career lieutenant dies following floor collapse into basement fire and a career fire fighter dies attempting to rescue the career lieutenant – New York PDF Adobe PDF file

Key contributing factors identified in this investigation include working above an uncontrolled, free-burning basement fire; interior condition reports not communicated to command; inadequate risk-versus-gain assessments; and, crew integrity not maintained.

NIOSH has concluded that, to minimize the risk of similar occurrences, fire departments should:

  • Ensure that all personnel are aware of the dangers of working above a fire, especially a basement fire, and develop, implement, and enforce a standard operating procedure (SOP) that addresses strategies and tactics for this type of fire.
  • Ensure that the incident commander (IC) receives interior status reports and performs/continues evaluating risk-versus-gain.
  • Ensure that crew integrity is maintained at all times on the fireground.
  • Ensure that the incident commander (IC) receives accurate personnel accountability reports (PAR) so that he can account for all personnel operating at an incident.
  • Ensure that a separate incident safety officer, independent from the incident commander, is appointed at each structure fire.
  • Ensure that fire fighters use their self-contained breathing apparatus (SCBA) and are trained in SCBA emergency procedures.

Additionally, manufacturers, equipment designers, and researchers should:

  • Conduct research into refining existing and developing new technologies to track the movement of fire fighters inside structures.
  • Continue to develop and refine durable, easy-to-use radio systems to enhance verbal and radio communication in conjunction with properly worn self-contained breathing apparatus (SCBA)

    Fire and Rescue Operations

     

Front of structure
Incident scene.
(Photo courtesy of fire department. From NIOSH REPORT)

 

RECOMMENDATIONS

Recommendation #1: Fire departments should ensure that all personnel are aware of the dangers of working above a fire, especially a basement fire, and develop, implement, and enforce a standard operating procedure (SOP) that addresses strategies and tactics for this type of fire.

Discussion: Basement fires can be taxing and test a fire fighter’s knowledge and skill on how to combat it safely and effectively. Fire burning underneath floors can significantly degrade the floor system with little indication to fire fighters working above.1 They need to be aware of rapid heat buildup, little or no ventilation, limited accessibility, and whether it is a storage place for unknown hazards (e.g., combustibles, hazardous materials, and flammable liquids). Also of concern for fire departments is how to determine how long a fire has gone undetected. Fire fighters should be aware of what is stored on the floor directly above a basement fire, what the finished floor is comprised of (e.g., terrazzo, plywood, tongue-and-groove, tile, etc.), and what the floor structural members are comprised of (e.g., engineered wood floor joists, concrete, or steel). Structural support members may be directly exposed to fire, causing them to weaken and increase the likelihood of an above-floor collapse. Interior crew(s) intending to operate on the floor above a basement fire should limit their operating time, especially if ventilation, suppression, and accessibility are not progressing. The floor’s structural members will continue to weaken as fire and heat intensify. Specifying an exact length of time for how long suppression crew(s) should operate above a basement fire is questionable, and the IC should make that determination by performing a hazard analysis/risk assessment. The fire department did not have an SOP specifically addressing strategies and tactics when combating basement fires. SOPs should be developed to address structural fire fighting operations specific to basement fires, because these types of fires present a complex set of circumstances and following established SOPs will minimize the risk of serious injury to fire fighters.

During this incident, fire fighters were unable to access the basement, unable to ventilate the basement fire, and unaware of the fire load found within the basement. Initially, the department did not cut a hole in the 1st floor apartment or deli and use their Bresnan distributor, in fear of injuring reported trapped civilians. Note: The Bresnan distributor is a type of cellar nozzle used to suppress fire through steam conversion. The use of a cellar nozzle, like a Bresnan distributor, during the initial stages of the basement fire may have assisted in containing the fire and/or allowing better operating conditions for fire fighters to access the basement.2 Attempts were made to flow water on the 1st floor where fire had vented through, but this effort was not successful. Fire fighters should also recognize that fire venting through a floor is a late indication of a weakened floor system.

Recommendation #2: Fire departments should ensure that the incident commander (IC) receives interior status reports and performs/continues evaluating risk-versus-gain.

Discussion: Among the most important duties of the first officer on the scene is conducting an initial size-up of the incident. A proper size-up begins from the moment the alarm is received, and it continues until the fire is under control. The size-up should also include assessments of risk-versus-gain during incident operations, especially after primary searches have been conducted.2-7 The size-up should include an evaluation of factors such as the fire size and location, length of time the fire has been burning, conditions on arrival, occupancy, fuel load and presence of combustible or hazardous materials, exposures, time of day, and weather conditions. Information on the structure itself should include size, construction type, age, condition (e.g., evidence of deterioration, weathering), evidence of renovations, lightweight construction, loads on roof and walls (e.g., air conditioning units, ventilation ductwork, utility entrances), and available preplan information are all key information that can affect whether an offensive or defensive strategy is employed. The incident commander should be willing to change his strategy and plan based on continued size-ups and risk assessments until the fire is brought under control. Conducting accurate size-ups and receiving interior/exterior status updates is critical to the safety of fire fighters on the incident, rescue/recovery efforts, and overall control of the incident. “The decision to commit interior firefighting personnel should be made on a case-by-case basis with proper risk-benefit decisions being made by the incident commander. The commitment of firefighters’ lives for saving property and an unknown or marginal risk of civilian life must be balanced appropriately.” 8 The fireground is very dynamic, and conditions can either improve or deteriorate based on fire suppression activities, and available resources, and most importantly assessments/size-ups of the incident are necessary to detect a change on the fireground.

During this incident, the fire department was attempting to gain access to reported trapped civilian(s) in a basement. The command post was established at the front of the structure providing views of Side 1 and Side 2. The basement contained heavy smoke and fire and was inaccessible from exterior and interior access doors. The initial IC and the IC who assumed command performed initial size-ups and received radio updates on fire and smoke conditions from personnel working on the incident, but not all interior findings were reported. Crews working in the 1st floor apartment encountered fire venting through the floor on Side 4 as early as 9 minutes after the first apparatus arrived on scene. Ten minutes later, Victim #1 was flowing water on fire that had vented in the corner of Side 3 and Side 4 of the deli. This was the same general area where crews within the 1st floor were working. The only thing separating the apartment and deli was a wall of floor coolers. The basement fire burned uncontrolled for more than 30 minutes while fire fighters continued attempts to gain access to the basement. Incident updates on the radio included transmissions such as “untenable” and “time to get out,” prior to the 1st floor partial collapse. The IC also mistook “water on the fire” as fire fighters actually attacking the basement fire from Side 2. This provided the IC with a false sense of progress on combating the basement fire. Also, during this incident, the IC was at times monitoring multiple radio channels and some additional transmissions may not have been received. Radio transmissions are very important for the IC to hear, acknowledge, and prioritize so that the IC can maintain situational awareness, and accurately and effectively manage and direct fireground operations. A chief’s aid or incident command technician assigned to the IC may have assisted the IC in monitoring the fireground channels and distinguishing key radio traffic and updates. It is reasonable to believe that, as time progressed and basement fire conditions continued to be uncontrolled, that the chances of survival diminished for any potentially trapped civilians exposed to the heat or products of combustion found within the smoke. According to fire investigators with the fire department, only the bodies of Victim #1 and Victim #2 were found within the structure.

Recommendation #3: Fire departments should ensure that crew integrity is maintained at all times on the fireground.

Discussion: Fire fighters should always work and remain in teams whenever they are operating in a hazardous environment.2 Team integrity depends on team members knowing who is on their team and who is the team leader; staying within visual contact at all times (if visibility is low, teams must stay within touch or voice distance of each other); communicating needs and observations to the team leader; and rotating together for team rehab, team staging, and watching out for each other (e.g., practicing a strong buddy system). Following these basic rules helps prevent serious injury or even death by providing personnel with the added safety net of fellow team members. Teams that enter a hazardous environment together should leave together to ensure that team continuity is maintained. 3

During this incident, raw video captured the FAST working on Side 1 of the structure (same side that Victim #1 had entered) during Victim #1’s “Mayday.” At the same time, Victim #2, assigned to the FAST, was seen pointing at Side 1, donning his SCBA, and entering the structure as other fire fighters were exiting from Side 1. The FAST was activated and ordered to Side 2 where it was believed the “Mayday” transmission came from. Victim #2 went missing following the “Mayday” and his whereabouts were unknown until the recovery of Victim #1. Also, Victim #1 entered the deli not realizing that two of his team members from R1 were not following behind. Not verifying your crew is with you and/or working alone increases the risk to individuals and possibly to others during search and rescue efforts. During interviews, the fire department commented on an increase in “freelancing” following the Mayday.

floor collapse from inside the building
Photo 6. Interior view of deli following partial floor
collapse and recovery operations.
(Photo courtesy of police photographer. From NIOSH REPORT)
basement storage basement storage
Photo 7 . Views of materials stored within basement.
(Photos courtesy of police photographer. From NIOSH REPORT)

 

Recommendation #4: Fire departments should ensure that the incident commander (IC) receives accurate personnel accountability reports (PAR) so that he can account for all personnel operating at an incident.

Discussion: An important aspect of an accountability system is the personnel accountability report (PAR). A PAR is an organized on-scene roll call in which each supervisor reports the status of his crew when requested by the IC or emergency dispatcher.2 The use of an accountability system is recommended by NFPA 1500 Standard on Fire Department Occupational Safety and Health Program9 and NFPA 1561 Standard on Emergency Services Incident Management System.10 A functional personnel accountability system requires the following:

  • development of a departmental SOP
  • training all personnel
  • strict enforcement during emergency incidents

As the incident escalates, additional staffing and resources may be needed, adding to the burden of tracking personnel. An incident command board should be established at this point with an assigned accountability officer or aide. As a fire escalates and additional fire companies respond, a chief’s aide or accountability officer assists the incident commander with accounting for all fire fighting companies at the fire, at the staging area, and at the rehabilitation area. With an accountability system in place, the incident commander may readily identify the location and time of all fire fighters on the fireground. A properly initiated and enforced accountability system that is consistently integrated into fireground command and control enhances fire fighter safety and survival by helping to ensure a more timely and successful identification and rescue of a disoriented or downed fire fighter. This department has developed and implemented SOPs governing accountability and even assigns an accountability officer to the IC to assist with radio transmissions and PARs.

An accountability officer was assigned to assist the IC during the incident. A PAR was immediately obtained following the rescue attempts for Victim #1. Victim #1 was identified as “missing,” but Victim #2 was incorrectly identified as “accounted for.” Victim #2 was incorrectly “accounted for” during a second separate PAR. Prior to a third PAR, 50 minutes following the floor collapse, Victim #2 could not be visibly accounted for on the fireground and his whereabouts were unknown. Officers need to visually account for their members prior to providing an “all accounted for” to the IC or accountability officer. Quickly being able to account for all personnel at an incident is paramount and can determine how an IC orders search and rescue efforts or other suppression activities.

Recommendation #5: Fire departments should ensure that a separate incident safety officer, independent from the incident commander, is appointed at each structure fire.

Discussion: According to NFPA 1561 Standard on Emergency Services Incident Management System, 11 “The incident commander shall have overall authority for management of the incident and the incident commander shall ensure that adequate safety measures are in place.” This shall include overall responsibility for the safety and health of all personnel and for other persons operating within the incident management system. While the incident commander is in overall command at the scene, certain functions must be delegated to ensure adequate scene management is accomplished. 10 According to NFPA 1500 Standard on Fire Department Occupational Safety and Health Program, 9 “as incidents escalate in size and complexity, the incident commander shall divide the incident into tactical-level management units and assign an incident safety officer (ISO) to assess the incident scene for hazards or potential hazards.” These standards indicate that the incident commander is in overall command at the scene but acknowledge that oversight of all operations is difficult. On-scene fire fighter health and safety is best preserved by delegating the function of safety and health oversight to the ISO. Additionally, the incident commander relies upon fire fighters and the ISO to relay feedback on fireground conditions in order to make timely, informed decisions regarding risk versus gain and offensive-versus-defensive operations. The safety of all personnel on the fireground is directly impacted by clear, concise, and timely communications among mutual aid fire departments, sector command, the ISO, and the incident commander. NFPA 1521 Standard for Fire Department Safety Officer defines the role of the ISO at an incident scene and identifies duties such as recon of the fireground and reporting pertinent information back to the incident commander; ensuring the department’s accountability system is in place and operational; monitoring radio transmissions and identifying barriers to effective communications; and ensuring established safety zones, collapse zones, hot zones, and other designated hazard areas are communicated to all members on scene.11 Larger fire departments may assign one or more full-time staff officers as safety officers who respond to working fires. In smaller departments, every officer should be prepared to function as the ISO when assigned by the incident commander. The presence of a safety officer does not diminish the responsibility of individual fire fighters and fire officers for their own safety and the safety of others. The ISO adds a higher level of attention and expertise to help the fire fighters and fire officers. The ISO must have particular expertise in analyzing safety hazards and must know the particular uses and limitations of protective equipment. 4

During this incident, the designated department ISO was not dispatched until the incident was upgraded to a 2nd alarm because it occurred after the normal duty shift of the ISO. The ISO did not arrive until rescue/recovery operations had begun on breaching the Side 4 wall. The presence of an ISO throughout this incident would have allowed the IC to focus on supervising the incident while the ISO directed safety operations.

Recommendation #6: Fire departments should ensure that fire fighters use their self-contained breathing apparatus (SCBA) and are trained in SCBA emergency procedures.

Discussion: Fire fighters are tasked at times to operate within environments which pose inhalation hazards (e.g., toxic smoke and oxygen deficiency12), defined by OSHA as immediately dangerous to life and health (IDLH). Proper training along with an implemented and enforced policy or procedure will assist fire fighters with proper maintenance, use, and removal of a SCBA. OSHA 29 CFR 1910.134 (g)(4)(iii) states, “all employees engaged in interior structural firefighting use SCBAs.”13 During this incident, the medical examiner stated both victims died from inhalation of products of combustion. The medical examiner also indicated that the victims’ COHb levels (a measure of carbon monoxide in the bloodstream) were over 50%. Even if nothing but carbon dioxide, water vapor, and nitrogen were present in the fire products and these were to mix with the air being breathed by a fire fighter, then the oxygen percentage would be reduced below the normal 21%. At 15% oxygen, fire fighters can experience lethargy, poor coordination, and confused thinking. The two principal toxins in smoke—carbon monoxide and hydrogen cyanide—act to deprive the brain of oxygen, and their effects would be enhanced due to the lower levels of oxygen in the air.14 Both victims were discovered without their facepieces on.

Due to the smoke conditions, both victims would have had to have been on air when entering the structure. It has not been determined why both victims were found without their facepieces on, but NIOSH investigators have theorized the following possibilities:

  • Victim #1 removed his facepiece to transmit his “Mayday.”
  • Both victims’ facepieces were unintentionally knocked off when falling into the basement.
  • The facepieces were removed because they ran out-of-air or other emergency situation.

Emergencies created by, or associated with, SCBAs can be overcome in several ways. Fire departments can develop and implement a comprehensive respiratory protection program15 that includes fire fighter fitness, training, competency, and skill in SCBA and emergency procedures. Firefighters should remember the first rule in any emergency situation, and that is not to panic. Panic causes increased breathing air consumption and inability to focus on emergency procedures. If fire fighters become lost, trapped, or disoriented they need to focus on managing remaining air in their SCBA cylinder until other fire fighters can make a rescue attempt. Removing one’s facepiece in an IDLH atmosphere can immediately expose the respiratory system to a potentially fatal environment, thus incapacitating an individual. Choosing to leave one’s SCBA facepiece on may be the best chance in providing additional time for a fire fighter to be rescued. Fire fighters should follow their department’s SOPs regarding emergency SCBA procedures and emergency communications.

Recommendation #7: Manufacturers, equipment designers, and researchers should conduct research into refining existing and developing new technologies to track the movement of fire fighters inside structures.

Discussion: Fire fighter fatalities often are the result of fire fighters becoming lost or disoriented on the fireground. The use of systems for locating lost or disoriented fire fighters could be instrumental in reducing the number of fire fighter deaths on the fireground. The National Institute of Standards and Technology (NIST) has been evaluating the feasibility of real-time fire fighter tracking and locator systems for some time.16, 17 Another group researching advanced fire fighter locator and tracking systems is the Maryland Fire Rescue Institute, located at the University of Maryland – College Park.18 Research into refining existing systems and developing new technologies for tracking the movement of fire fighters on the fireground should continue. While it is not clear that the use of this technology in this incident would have prevented the fatalities, such technology could potentially have reduced the search time by aiding rescue teams in pin-pointing the location of the missing fire fighters. This new technology must function properly in the severe fire conditions often encountered during rescue operations.

During the initial stages of the incident, it was not known who was transmitting the Mayday, where exactly they were in the basement, or how they got into the basement. Victim #2 went accounted for approximately 50 minutes before a determination was made that Victim #2 was also missing. It was not until rescue/recovery crews visually located the victims that they accounted for the location of Victim #2. This technology may have assisted the fire department during this incident in more quickly locating Victim #1 and Victim #2.

Of importance, Victim #1’s PASS device was alarming during the Mayday and when he was discovered, but it was reported to NIOSH investigators that Victim #2’s PASS device was never heard. Victim #2’s PASS device was evaluated as part of NIOSH’S NPPTL SCBA inspection. Victim #2’s PASS device failed to function when tested, but after the batteries were replaced within the PASS device, it alarmed appropriately. It has not been determined if the battery life was exhausted prior to Victim #2 going into the structure. It is important to note that the 2007 revision to NFPA 1982 Standard on Personal Alert Safety Systems (PASS) includes new heat and flame resistance requirements resulting from documented reports where PASS devices were not heard during fatal fireground incidents. 19 Laboratory testing conducted by NIST determined that exposure to high temperature environments caused the loudness of the tested PASS alarm signal to be reduced. This reduction in loudness can cause the alarm signal to become indistinguishable from background noise at an emergency scene. Initial laboratory testing by NIST highlighted that this sound reduction may begin to occur at temperatures as low as 300°F. Thus the use of PASS devices meeting NFPA 1982, 2007 Edition requirements is highly recommended.

Recommendation #8: Manufacturers, equipment designers, and researchers should continue to develop and refine durable, easy-to-use radio systems to enhance verbal and radio communication in conjunction with properly worn self-contained breathing apparatus (SCBA).

Discussion: The use of Personal Protective Equipment (PPE) and an SCBA make it difficult to communicate, with or without a radio.20-22 Faced with the difficult task of communicating while wearing a SCBA, fire fighters sometimes momentarily remove their facepieces to transmit a message directly or over a portable radio. Considering the toxic and oxygen-deficient hazards posed by a fire and the resulting products of combustion, removing the SCBA facepiece, even briefly, is a dangerous practice that should be prohibited. Even small exposures to carbon monoxide and other toxic agents present during a fire can affect judgment and decision-making abilities. To facilitate communication, equipment manufacturers have designed facepiece-integrated microphones, intercom systems, throat mikes, and bone conduction mikes worn in the ear or on the forehead.20-22

During this incident, interviewed fire fighters complained of radio transmissions being unintelligible at times or not heard at all. Although NIOSH investigators are not certain why Victim #1 and Victim #2 were found without their facepieces on, one theory is that Victim #1 may have momentarily removed his facepiece to better transmit his Mayday. Fire fighters recall hearing his transmissions as they came across the radio and also emanating clearly from the structure.

Recent testing by the National Institute for Standards and Technology (NIST) of portable radios in simulated fire fighting environments has identified that radios are vulnerable to exposures to elevated temperatures. Some degradation of radio performance was measured at elevated temperatures ranging from 100°C to 260°C, with the radios returning to normal function after cooling down. Additional research is needed in this area.16, 20 Fire service radios also need to be waterproof as normal fireground conditions dictate that radios are frequently exposed to excessive amounts of water during routine use through exposure to hose streams, overspray, water dripping from overhead, etc.

Other Links;

 

FDNY- August 27, 2006 Walton and East Mount Eden Avenues, Bronx, NY

Floor Collapse at Commercial Structure Fire Claims the Lives of One Career Lieutenant and One Career Fire Fighter – New York (REPORT HERE)

SUMMARY
On August 27, 2006, a 43-year-old male career Lieutenant (victim #1) and a 25-year-old male fire fighter (victim #2) died after the floor they were operating on collapsed at a commercial structure fire. At approximately 1230 hours, crews were dispatched to a fire. The victims’ engine was dispatched at 1236 hours as an additional unit alarm and arrived on the scene at approximately 1240 hours. At approximately 1251 hours, victim #1, victim #2 and fire fighter #1 advanced a 2 ½-inch hand line through the front of the structure and down an aisle toward the rear of the store. The fire was located in the rear interior of the structure (discount store) that sold a variety of numerous small household commodity items. Approximately three minutes later, the structural members supporting the floor directly below the victims failed. The V-shaped collapse of the floor caused victim #1 and victim #2 to fall into the basement and shelving stocked with merchandise to fall in on top of them. Multiple MAYDAYs were transmitted and the fire fighter assist and search team (FAST) was deployed to the front of the structure where they assisted in the rescue of numerous members who had been operating in the interior of the structure at the time of the collapse. Battalion Chief #1, Lieutenant #1 and fire fighter #1 were freed from the debris. At approximately 1415 hours, victim #1 was removed from the debris in the basement and transported to the hospital. He died the next day as a result of his injuries. At approximately 1435 hours, victim #2 was removed from the basement and transported to the hospital where he was pronounced deceased as a result of his injuries.

F2006-27 Aug 27, 2006 Floor collapse at commercial structure fire claims the lives of one career lieutenant and one career fire fighter – New York PDF Adobe PDF file

NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should:

  • consider the possibility of a substandard structure when building information is not available from pre-incident plans
  • consider the live load of water on the structure and go defensive when water load potentially compromises the structural integrity

Additionally, municipalities should:

  • explore means of coordinating information sharing between building and fire departments to increase safety for fire fighters and civilians
  • consider conducting inspections on all commercial structures where a change of occupancy has occurred or renovations are known or suspected, giving special attention to non-sprinklered commercial retail structures

RECOMMENDATIONS/DISCUSSIONS

Recommendation #1: Fire departments should consider the possibility of a substandard structure when building information is not available from pre-incident plans, and implement a defensive strategy when no occupants are at risk.

Discussion: The threat of a collapse of some type (i.e. roof, ceiling, floor or wall) is a possibility in any structural fire due to the effects of fire, water application, age, insects, and alterations. It is a high probability that a fire department is unaware of structural defects caused by age, insects and alterations. To minimize the risk of injury or death to fire fighters during structural operations, the size-up and risk assessment includes many factors, which include: age of the building (deterioration of structural members, evidence of weathering, use of lightweight materials in new construction), occupancy, and renovations or modifications to the building.3,4,5

Pre-incident plans are an effective tool in preventing injuries and deaths of fire fighters due to structural collapse.  They allow fire departments to determine factors, such as, age of the structure, structural integrity, type of materials used in the structure, and amount of load on the roof that could weaken the supports, etc.  However, in numerous cities and towns where buildings number in the hundreds of thousands, fire departments lack the manpower to pre-plan all buildings under their protection. Often fire departments are limited to targeting buildings that have a unique construction or pose a known hazard.

In floor collapses that have occurred, such as those at a New York City drug store (October 17, 1966) and at a Boston hotel (June 17, 1972), there were no warning signs, and no time to act and withdraw fire fighters to safety. At both of these floor collapses, unauthorized alterations on the structure contributed to the structural failure.5

“The potential for structural collapse is one of the most difficult factors to predict during initial size-up and ongoing fire fighting. Structural collapse usually occurs without warning.” 3 When pre-incident plan information on the fire structure is not available, occupants have been evacuated, and evidence of structural deterioration and/or modification cannot be determined, a defensive strategy should be implemented. A defensive strategy would help ensure fire fighter safety and is warranted in structures that lack pre-incident plans, no occupants are at risk, and where the potential for numerous unrecognized hazards exists, such as substandard construction and building deterioration.

Fire departments operating in older businesses and homes should be suspicious of potential alterations and renovations which could result in unsupported loads and unusual voids. These alterations may be hidden by sheetrock (drywall) or flooring and built up flooring which is difficult to detect during inspections and virtually impossible to detect during firefighting operations. The older the structure, the greater the possibility of renovation or remodel.

In this case, there were no current pre-incident plans for the structure; the occupants had evacuated upon the fire department’s arrival, and compromised structural integrity was not immediately evident. Structural alterations had been made to the girders, columns, and floor in order to presumably level and support the floor. A post incident inspection showed 2 x 4 boards being used inappropriately (in orientation and stability) as a floor joist. A cluster of nails were used in lieu of bolts to attach gusset plates to the columns and girders. Sheets of plywood were added to the floor with no structural support around the sheet’s edges nor at 12”, 16” or even 24” intervals in accordance with standard building codes. Subflooring (i.e., plywood, wafer board, etc.) needs to be fastened around the sheet’s edges and at interval spacing (generally every 16 inches, but spacing may vary according to load requirements) to support floor joists. The interior support members of the structure suffered from severe rot at the base of the timber columns.

Recommendation #2 : Fire departments should consider the live load of water on the structure and go defensive when water load potentially compromises the structural integrity.

Discussion: A forensic engineering analysis of the fire building demonstrated that the weight of water added to the building from the fire fighting operations was approximately 50% of the rated structural capacity of the floor.2 As noted previously, however, timbers that supported the ground floor had rotted. Thus, the actual structural capacity of the floor was less than rated. Although the ultimate cause of the collapse was the rotted timbers, the weight of the water applied during the fire fighting operations, in addition to the weight of fire fighters, store merchandise, etc., likely contributed to the collapse. Given the many unknowns during fire fighting operations, including in most incidents the rated capacity of floors, incident commanders need to continuously consider the impact of water weight on structural integrity, and shift to defensive strategies when structural integrity is potentially compromised.

Firefighting operations can drastically increase the live load on the fire building. This can be due to the weight of:

  1. the firefighters with their protective equipment and tools,
  2. the hose-line brought into the fire building, and
  3. the water used to attack the fire6.

A 2 ½ -inch hose-line can deliver approximately 250 gallons of water per minute. 5 This adds about 2,082 pounds per minute into the fire building. If multiple hose-lines are operating, the weight of the water can be tremendous.

When operating in an offensive mode, a buildup of water within a building requires that immediate action be taken to alleviate these conditions. 6 The remedy may be as simple as controlling the excess flow from the hose-line or moving fire debris that is restricting runoff. When using large amounts of water, it is always advisable to provide for drainage when necessary. This can be accomplished any number of ways from chutes with traps to actual holes drilled to provide relief. 6

It must be recognized that at the same time that this additional weight is being introduced into the fire building, the fire and water are weakening the structure. Under these conditions, a defensive strategy is best when no civilians are in the structure. 5

In this case, civilians had evacuated the fire building upon the fire department’s arrival. The structures’ configuration only enabled an initial attack through the front of the structure and down narrow aisle ways to the rear of the structure where the origin of the fire was located. Prior to the collapse, three 2 ½-inch hose-lines (operating 17 minutes, 8 minutes, and 2 minutes, respectively) were flowing water through and into the rear of the structure. The added weight and flow of the water could have contributed to the floor collapse because of the rotted support columns decreasing the timber frame system’s ability to equalize the water load across the floor.

location of victims
Diagram 2. Shows location of victims on the structure’s floor above the girder that failed. From the NIOSH REPORT

 

Additionally,

Recommendation #3 : Municipalities should explore means of coordinating information sharing between building and fire departments to increase safety for fire fighters and civilians

Discussion: Information on building construction, renovations, and alterations can help Incident Commanders develop strategies and tactics that effectively fight fires while attending to fire fighter safety. Pre-incident plans are a useful tool for ensuring that fire departments and Incident Commanders have information on building construction and contents to guide decision-making on the fireground. In urban areas with large numbers of existing structures, it may not be feasible to develop pre-incident plans for all or most structures, and for fire departments to regularly revisit structures to update pre-incident plans. Municipal building departments that issue building permits and conduct code inspections may collect, or be in position to collect, information that may be useful to fire departments. Municipalities should consider exploring mechanisms by which building information relevant to fire fighter and civilian safety can be collected and shared between building and fire departments. As one example, building departments could notify fire departments when building permits are issued. This would result in fire departments being aware of these building alterations, and to possibly target these buildings for a pre-incident plan. Priority should be given to sharing such information for targeted hazards identified by fire departments.

Recommendation #4: Municipalities should consider conducting inspections on all commercial structures where a change of occupancy has occurred or renovations are known or suspected, giving special attention to non-sprinklered commercial retail structures

Discussion: Occupancy changes understandably occur with great frequency. However, every effort should be made as new permits are issued to aggressively inspect any occupancy change. It is critical that municipalities assess that any renovations or remodeling meets current codes, and that original and renovated supports are capable of supporting the new occupancies. These building inspections should specifically consider the loading or redistribution of stock to ensure that flooring can handle dead and live loads.

Other Links;

National Institute for Occupational Safety and Health (NIOSH) Fire Fighter Fatality Investigation and Prevention Program

No comments

Video Clip recorded live by Fire Department Network News TV (FDNNTV) at the 50th IAFF Fire Fighter Convention in San Diego, CA on August 23, 2010.

The National Institute for Occupational Safety and Health, also known as NIOSH, is a federal agency that is part of the Centers for Disease Control. NIOSH has a mission of generating new knowledge in the occupational safety and health field and to transfer that knowledge into practice for the advancement of workers, including firefighters and emergency responders.

In 1998, the International Association of Fire Fighters (IAFF) requested that Congress fund NIOSH to start a firefighter safety initiative called the NIOSH Fire Fighter Fatality Investigation and Prevention Program.  “We investigate fatalities to learn from the mistakes the others made and to try to prevent future fatalities and injuries from occurring in similar events,” stated Project Officer Tim Merinar with the NIOSH Fire Fighter Fatality Investigation and Prevention Program. According to NIOSH, the Fire Fighter Fatality Investigation Program has made over 1,000 recommendations arising from over 300 investigations since its inception in 1998.

Merinar claimed that some do not fully understand who NIOSH is and what their goals are, often being confused with OSHA. However, the National Institute for Occupational Safety and Health is not an enforcement agency, they are a research and education agency. Merinar added, “We’re not looking to find fault or place blame on the fire departments or the individual firefighters in the incidents.”

As soon as possible after an incident, a NIOSH investigator will meet with the fire department. “Oftentimes, we have to explain who we are, why we’re there, what we’re trying to accomplish,” added Merinar. NIOSH investigates as many firefighter fatalities as possible involving structure fires, deaths from cardiovascular disease, as well as deaths during non-fireground incidents.

NIOSH offers many different publications to firefighters, including their newest one about risk management at structure fires. This literature is distributed to the fire service free of charge. Another publication offered to firefighters deals with floor joists and the risk of falling through fire-damaged floors. “They work very well for the construction industry, but when they’re exposed to fire they also fail very rapidly. Which leads to early building collapses,” explained Merinar. “Many firefighters have been injured and killed in these collapses.”

NIOSH FFFIPP

Trends such as this uncovered during their investigations and spread to the fire service, could help prevent future deaths. Another trend found several years ago by NIOSH involved PASS devices not sounding on firefighters who died. According to Merinar, NIOSH worked with the National Fire Protection Association to have the standard changed to make the PASS devices more reliable and more effective for firefighters. Currently, they are working with the NFPA on the thermal degradation characteristics of face piece lenses.

Fire Fighter Fatality Investigation and Prevention Program

For more information on the NIOSH Fire Fighter Fatality Investigation and Prevention Program, incident reports or fire fighter publications, visit www.cdc.gov/niosh/fire/.

Cold-Storage and Warehouse Building Fire

Topic Index:

Reports and Publications
  Safety Advisories
  Fatality Reports
  Pending Investigations
  Safety Quizzes
  Publications
Program Information
  Program Description
  What to Expect During a NIOSH Investigation
  Public Comment Docket
  Future Directions
  Inspector General’s Program Review
  IAFC’s Program Review
  Fire Fighter Fatality Investigation and Prevention Program Evaluation
  Strategic Plan – 2009

 

NIOSH Request for Comment on the Fire Fighter Fatality Investigation and Prevention Program The NIOSH Fire Fighter Fatality Investigation and Prevention Program (FFFIPP) is seeking stakeholder input to ensure that the FFFIPP program is meeting the needs and expectations of the fire service, and to identify ways in which the program can be improved to increase its impact on the safety and health of fire fighters across the United States. Additional information can be found in the FFFIPP Progress Report and Proposed Future Directions document.

Stakeholder Comment on the National Institute for Occupational Safety and Health (NIOSH) Fire Fighter Fatality Investigation and Prevention Program (FFFIPP)-2011
The National Institute for Occupational Safety and Health (NIOSH) is seeking stakeholder input on the progress and future directions of the Fire Fighter Fatality Investigation and Prevention Program (FFFIPP). Since its initiation in 1998, NIOSH has sought public input to help plan and direct the goals and objectives of the FFFIPP. NIOSH received public comments on the FFFIPP in 1998, March 2006, and November 2008. NIOSH is again seeking input on the progress and future directions of the FFFIPP to ensure that the program is meeting the needs and expectations of the U.S. fire service and to identify ways in which the program can improve its impact on the safety and health of fire fighters across the United States. NIOSH will compile and consider all comments received and use them in making decisions on how to proceed with the FFFIPP.

There are several resources that may be useful to individuals and groups who would like to comment on the FFFIPP:

  • The NIOSH Fire Fighter Fatality Investigation and Prevention Program Progress (FFFIPP) Report and Proposed Future Directions – 2011. This document includes specific topics for stakeholder input.
  • The Strategic Plan for the NIOSH Fire Fighter Fatality Investigation and Prevention Program that was finalized in 2009 after public input.
  • The FFFIPP web site that includes an overview of the FFFIPP, fatality investigation reports and other publications.

Related Dockets
NIOSH Docket number 063NIOSH Docket number 063-A
——————————————————————————–

Public Comment Period
Written comments on the document will be accepted through July 29, 2011 in accordance with the instructions below. All material submitted to NIOSH should reference Docket Number NIOSH-063-B. All electronic comments should be formatted as Microsoft Word documents and make reference to docket number NIOSH-063-B.

Comments will be accepted until 5:00 p.m. EDT on July 29, 2011

To submit comments, please use one of these options:

  • Send NIOSH comments using this online form
  • Send comments by email.
  • Fax comments to the NIOSH Docket Office: 513-533-8285
  • Send by Mail to:
    NIOSH Mailstop: C-34
    Robert A. Taft Lab.
    4676 Columbia Parkway
    Cincinnati, Ohio 45226
    All information received in response to this notice will be available for public examination and copying at the …
    NIOSH Docket Office
    4676 Columbia Parkway, Room 111
    Cincinnati, Ohio 45226.

A complete electronic docket containing all comments submitted will be available on the NIOSH docket home page, and comments will be available in writing by request. NIOSH includes all comments received without change in the docket, including any personal information provided.

Contact persons for technical information

  • Paul Moore
    Chief, Fatality Investigations Team
    NIOSH/CDC
    1095 Willowdale Road
    Mailstop H-1808
    Morgantown, WV 26505
    304/285-6016

Recent NIOSH Fire Fighter Safety Publications

Preventing Deaths and Injuries of Fire Fighters Operating Modified Excess/Surplus Vehicles
DHHS (NIOSH) Publication No. 2011-125
Fire fighters may be at risk for crash-related injuries while operating excess and other surplus vehicles that have been modified for fire service use. Fire departments with limited resources often craft fire apparatus out of excess/surplus military and other vehicles as an affordable alternative to purchasing new or used apparatus. NIOSH urges fire departments to take precautions and actions to minimize the hazards and risks to fire fighters when using modified excess/surplus vehicles.

Evaluation of Chemical and Particle Exposures During Vehicle Fire Suppression Training (2010)this document in PDF (56 pages, 4.85 MB)
Health Hazard Evaluation Report, HETA 2008-0241-3113
In September 2008 and July 2009, NIOSH researchers collected area and personal breathing zone air samples during a Health Hazard Evaluation (HHE) to evaluate firefighters’ exposures to airborne chemicals during vehicle fire suppression training. Several hazardous chemicals were found on the area samples, including respiratory toxicants and potential carcinogens. Of the chemicals measured in the personal breathing zones, levels of formaldehyde, carbon monoxide, and isocyanates were near or above short term exposure limits or ceiling limits. In addition, the number of particles and mass of the particles in the air increased during knockdown and remained elevated throughout the fire overhaul. Based on this evaluation, the levels of gases and particles released during vehicle fires have the potential to cause acute health effects to firefighters who do not wear self-contained breathing apparatus.

NIOSH Alert: Preventing Deaths and Injuries of Fire Fighters using Risk Management Principles at Structure Fires
DHHS (NIOSH) Publication No. 2010-153
Fire fighters are often killed or injured when fighting fires in abandoned, vacant, and unoccupied structures. These structures pose additional and sometimes unique risks due to the potential for fire fighters to encounter unexpected and unsafe building conditions such as dilapidation, decay, damage from previous fires and vandals, and other factors such as uncertain occupancy status. Risk management principles must be applied at all structure fires to ensure the appropriate strategy and tactics are used based on the fireground conditions encountered.

Preventing Exposures to Bloodborne Pathogens among Paramedics
DHHS (NIOSH) Publication No. 2010-139
Patient care puts paramedics at risk of exposure to blood. These exposures carry the risk of infection from bloodborne pathogens such as hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV), which causes AIDS. A national survey of 2,664 paramedics contributed new information about their risk of exposure to blood and identified opportunities to control exposures and prevent infections.

Preventing Deaths and Injuries of Fire Fighters Working Above Fire-Damaged Floors
DHHS (NIOSH) Publication No. 2009-114
Fire fighters are at risk of falling through fire-damaged floors.

Fire Fighter Fatality Investigation and Prevention Program: Leading Recommendations for Preventing Fire Fighter Fatalities, 1998–2005
DHHS (NIOSH) Publication No. 2009-100
This document is a synthesis of the 1,286 individual recommendations from the 335 FFFIPP investigations conducted from 1998 to 2005.

Fire Fighter Fatality Investigation and Prevention Program Evaluation
NIOSH report of findings from its national survey of U.S. fire departments.

Preventing Fire Fighter Fatalities Due to Heart Attacks and Other Sudden Cardiovascular Events
DHHS (NIOSH) Publication No. 2007-133
Fire fighters are at risk of dying on the job from preventable cardiovascular conditions.

FDA AND NIOSH Public Health Notification: Oxygen Regulator Fires Resulting from Incorrect Use of CGA 870 Seals External Web Site Policy
This document provides information on the danger of fires at the interface of oxygen regulators and cylinder valves because of incorrect use of CGA 870 seals, and identifies measures to prevent such fires.

NIOSH Alert: Preventing Injuries and Deaths of Fire Fighters due to Truss System Failures
DHHS (NIOSH) Publication No. 2005-132
Fire fighters may be injured and killed when fire-damaged roof and floor truss systems collapse, sometimes without warning.

NIOSH Workplace Solutions—Preventing Deaths and Injuries to Fire Fighters During Live-Fire Training in Acquired Structures
DHHS (NIOSH) Publication No. 2005-102
Fire fighters are subjected to many hazards when participating in live-fire training. Training facilities with approved burn buildings should be used for live-fire training whenever possible. However, when acquired structures are used for live-fire training, NIOSH strongly recommends that fire departments follow the national consensus guidelines in NFPA 1403, standard on live-fire training evolutions [NFPA 2002a] to reduce the risk of injury and death. These guidelines are summarized in the recommendations in this document.

Radio Communication

The past few decades have seen major advancements in the communication industry. These advancements have improved radio frequency spectrum efficiency, but also have added complexity to the expansion of existing systems and the design of new systems. The U.S. Fire Administration in conjunction with the International Association of Fire Fighters has released the report Voice Radio Communications Guide for the Fire Service External Web Site Policy this document in PDF 3.85 MB (77 pages) This report is designed to help fire service leaders and members understand new communication and radio system issues in order to remain informed players in the process.

Current Status, Knowledge Gaps, and Research Needs Pertaining to Firefighter Radio Communication Systems
The National Institute for Occupational Safety and Health (NIOSH) commissioned this study to identify and address specific deficiencies in firefighter radio communications and to identify technologies that may address these deficiencies. Specifically to be addressed were current and emerging technologies that improve, or hold promise to improve, firefighter radio communications and provide firefighter location in structures.

The National Institute of Standards and Technology, Building and Fire Research Laboratory publication “Testing of Portable Radios in a Fire Fighting EnvironmentExternal Web Site Policy this document in PDF 265 KB (24 pages)
focuses on the thermal environment that radios would be expected to withstand while being used in structural fire fighting operations. Current NFPA standards for radios are reviewed and recommendations for establishing performance standards are presented. The need for providing additional protection from the thermal environment is documented.

Fire/EMS Safety, Health and Survival Week 2011, Day Seven; Fire Fighter, Fire Officer and Command Training and Preparedness

3 comments

Preparing for the Mayday Event; Not a matter of IF, But a Question of When… Are you ready? Are you Prepared?

As the official Fire/EMS Safety Week 2011 begins to wind down, in many stations around the country this weekend is dedicated to training, drills and evolutions dedicated toward the many facets and functional elements that focus upon Surviving the Fire Ground – Fire Fighter, Fire Officer and Command Preparedness. 

The Safety Planning and Resource Aid and Guide published by the IAFC and IAFF (HERE) and the direct link here 2011 Planning and Resource Aid for Training Deliveries provided resources and planning templates and suggested training and activities to support the focus and emphasis on fire ground survival, increased focus on firefighter operations and mayday elements crucial to company integrity, firefighter safety and operational excellence.

Being ready for a mayday (mentally and physically), self-rescue and self-survival training and methodologies are mission critical when engaging in structural firefighting operations. Proficiencies, capabilities, rigor, demeanor and performance must be orchestrated in a manner that requires optimum execution of required actions and engagements to enable a successful outcome to a reported single or multiple mayday calls.

On a crisp fall day in October, 2009 two fires, both in residential occupancies but over 350 miles apart had similar operational needs, deployment and fire suppression and rescue engagement consistent with modern firefighting practices, methodologies and expectations.

In one, three firefighters become trapped, resulting in a mayday, bailout and resulting LODD of a 16 year fire service veteran. City of Yonkers (NY) Firefighter Patrick Joyce  died during the operations at a 3-Alarm fire in a three story residential occupancy while conducting search and rescue operations for reported trapped civilians. Incident overviews; HERE and HERE .

The other structure fire in a residential occupancy in Syracuse, NY, results in a fire fighter mayday and successful RIT extraction that is captured on video.  Two structure fires with common elements, each with projected predictable outcomes based upon past fire department operational experiences at similar structures, occupancies and fire conditions and reports; however with two different outcomes.

The program information from The IAFF Fire Ground Survival Program (FGS)which forms a major component of thsis year’s Safety Weeks activities with the focus on comprehensive survival-skills and mayday-prevention programming  incorporating incident-management best practices and survival techniques from leaders in the field, and real case studies from experienced fire fighters, with the FGS program objectives  aimed to educate all fire fighters to be prepared if the unfortunate happens.

  • For links to the IAFF Fire Ground Survival Program, HERE and HERE

Here’s a recap of the Self-Survial Procedure insights from the FGS Chapter 3 Section;

Self-Survival Procedures

FGS Online Program Chapter 3
To improve survivability in a Mayday situation, a fire fighter must know how to alert rescuers to his or her location and perform self-survival techniques. Through the study of fire fighter fatalities, NIOSH has identified specific actions fire fighters can take to help save themselves. Variations of this same NIOSH recommendation have appeared in numerous fire fighter fatality reports. These recommendations were used to create a self survival procedure that is easy to remember using a mnemonic (GRAB LIVES). Following these steps increases the likelihood of the rescuers finding and assisting the fire fighter to safety.
When a fire captain died when trapped by partial roof collapse in a vacant house fire in Texas, NIOSH recommended in report number F2005-09 that trapped fire fighters should:

  • First, transmit a distress signal while they still have the capability and sufficient air.
  • Next, manually activate their PASS device. To conserve air while waiting to be rescued, try to stay calm and avoid unnecessary physical activity.
  • If not in immediate danger, remain in one place to help rescuers locate them.
  • Survey their surroundings to get their bearings and determine potential escape routes.
  • Stay in radio contact with the IC and other rescuers.
  • Attract attention by maximizing the sound of their PASS device (e.g., by pointing it in an open direction); pointing their flashlight toward the ceiling or moving it around; and using a tool to make tapping noises on the floor or wall. 

The following video clip depicting FDNY Rescue Co. 1 operations at a Mayday, and provides some insightful and subtle commentary that should put some things in proper perspective about the job its hazards and the unexpected that can occur in the blink of an eye.

 

Another exceptional training piece that we are providing again here on CommandSafety.com are the two part video clips provided by TheBravestOnline.com that covers the mayday distress cakk an subsequent RIT extraction of HFD Captain Joel Eric Abbt at a four alarm fire with civilian fatalities in a six story high rise office building on March 28, 2007.

This video along with the information obtained from the FGS  program can provide substantial opportunites for training, discussions and dialog.  Take the time to watch the HFD vdeo and the elapsed time, communications and actions deployed. This mayday event had a successful outcome due to a variety of factors.

The question is how prepared are you, your firefighters, the officers and commanders? Surviving the fire ground requires a  wide variety of skills, knowledge , training and experience.

Training is the foundation from which proficiencies are developed. If your organization has invested in supporting this weeks activities, don’t stop here. There are additional day ahead to take teh momentum gathered from this week and use it to chart a new course of actions and committments for the weeks and months ahead. If you didn’t have the opportunity to engage or involve, its not a missed opportuity- just find the right time and place to have your own safety day of week.

Houston FD Mayday Part 1

Houston FD Mayday Part 2

Other Training and Drill Opportunties

Suggested Considerations include the follow, as well as encouraging Departments to identify and integrate local issues, needs and identified gaps or enhancements that can contribute towards operational excellence and safety integration

  • Review and Select a Near Miss Event Report from the National Fire Fighter Near Miss Reporting System or the Report of the Week (ROTW) series related to functional area topics or mayday actions and discuss the event in a small group or company setting to identify similarities or difference from your our organization. Is your company or department susceptible to a similar event? What should be addressed? http://www.firefighternearmiss.com/
  • Review and Select a NIOSH LODD Report from the NIOSH Fire Fighter Fatality Investigation Program related to functional area topics or mayday actions and discuss the event in a small group or company setting to identify similarities or difference from your our organization. Is your company or department susceptible to a similar event? What should be addressed? http://www.cdc.gov/niosh/fire/
  • Take out your Rapid Intervention Equipment and review the purpose and function of each piece of equipment. Identify and discuss alternative uses or tools that can be obtained or used in the event of unavailability, malfunction or additional resource needs. Discuss protocols, procedures, safety awareness and operational hazards, expectations and precautions. Inspection the equipment for operability and integrity.
  • Identify and select a recent departmental or local/regional incident event that was either a near-miss/close-call or transitioned into a mayday event. Discuss and facilitate dialog on lessons learned, gaps, enhancements or operational successes, achievements and positive elements. Identify any factors or elements that were presented in the FGS training series that are applicable to the event, strategies, tactics or operations: can anything be improved or enhanced?
  • Lead a discussion on how to call and initiate a Mayday. Discuss the factors and insights from FGS Program Chapter 3 Self-Survival Procedures and Chapter 4 Self-Survival Skills.
  • Select and lead a discussion on a pertinent incident case study from either the list provided or your own selection and discuss the relevancy of the event in terms of mayday operations, fire ground survival, incident outcome and relationship to your Department or agency. What is the relevancy, similarities or differences? Can this event or circumstances occur in your jurisdiction?  What can be done to prevent a history repeating event (HRE)?
  • Review and discuss Roles and Responsibilities for mayday events and operations. How do they match up with your operating procedures, policies and expectations?
  • Develop and facilitate a table top exercise (TTE) on a mayday event scenario utilizing a building in your first-due or response jurisdiction. Take photographs and integrate into your program. Refer to example of a simple TTE  attached or go to Fire Fighternation.com for an example here; http://www.firefighternation.com/forum/topics/box-2752reported-fire-in-an
  • Visit a residential or commercial construction site (with pre-arrival authorization and approvals) and tour the stage of construction, looking critically at the type of construction and structural systems being implemented, materials used, workmanship and signs of deficient or adverse conditions that may affect operational integrity, safety or collapse and compromise once the building is occupied. Discuss issues such as structural integrity, collapse risk, occupancy risk versus occupancy type considerations, avenues for fire travel, effects on fire load package and rate of heat release and projected fire intensity. How would you fire a fire in the occupancy? What will define the strategy and tactics that would be or should be selected and used?
  • In a controlled setting with or without PPE, Practice calling a mayday with the identified communication attributes defined in the FGS training program. Critique and practice the evolution until the group feels that it is acceptable.

Here are some additional Resource Links to Support your training and drill needs;

Selected References

  • IAFC: The Rules of Engagement for Firefighter Survival and The Incident Commanders Rules of Engagement for Firefighter Safety, HERE and HERE
  • NIOSH Publication No. 2010-153:NIOSH Alert: Preventing Deaths and Injuries of Fire Fighters using Risk Management Principles at Structure Fires, HERE
  • What’s on your Radar Screen; http://commandsafety.com/2010/07/whats-on-your-radar-screen/
  • Reflecting upon these days of June; http://commandsafety.com/2010/06/reflecting-on-these-days-of-june/
  • http://www.isfsi.org/Resources/ResourceLinks.aspx
  • ·         NIST References HERE and HERE 
  • ·         Fire Fighting Tactics Under Wind Driven Conditions Report, HERE 
  • ·         Reference Data HERE 
  • ·         NIST Firefighter Safety and Deployment Study; Report on Residential Fireground Field Experiments download at the NIST, HERE or Synopsis HERE 
  • Report: Trends in Firefighter Fatalities Due to Structural Collapse1979-2002
  • Report: Early Warning Capabilities for Firefighters:Testing of Collapse Prediction Technologies
  • ·         UL University on-line Program HERE 
  • NIOSH LODD Reports
    • Each year an average of 105 fire fighters die in the line of duty. To address this continuing national occupational fatality problem, NIOSH conducts independent investigations of fire fighter line of duty deaths. The dedicated web page provides access to NIOSH investigation reports and other fire fighter safety resources.
    • NIOSH Web Page HERE
    • Through the Fire Fighter Fatality Investigation and Prevention Program, NIOSH conducts investigations of fire fighter line-of-duty deaths to formulate recommendations for preventing future deaths and injuries. The program does not seek to determine fault or place blame on fire departments or individual fire fighters, but to learn from these tragic events and prevent future similar events.
    • Fire Fighter Fatality Investigation Reports, HERE
    • NIOSH Alert: Preventing Deaths and Injuries of Fire Fighters using Risk Management Principles at Structure Fires
      • Fire fighters are often killed or injured when fighting fires in abandoned, vacant, and unoccupied structures.
      • These structures pose additional and sometimes unique risks due to the potential for fire fighters to encounter unexpected and unsafe building conditions such as dilapidation, decay, damage from previous fires and vandals, and other factors such as uncertain occupancy status. Risk management principles must be applied at all structure fires to ensure the appropriate strategy and tactics are used based on the fireground conditions encountered.
      • Report HERE
      • NIOSH Report; Preventing Deaths and Injuries of Fire Fighters Working Above Fire Damaged Floors
        • Fire fighters are at risk of falling through fire-damaged floors. Fire burning underneath floors can significantly degrade the floor system with little indication to fire fighters working above.
        • Floors can fail within minutes of fire exposure, and new construction technology such as engineered wood floor joists may fail sooner than traditional construction methods.
        • NIOSH recommends that fire fighters use extreme caution when entering any structure that may have fire burning beneath the floor.
        • Report HERE
        • NIOSH ALERT: Preventing Injuries and Deaths of Fire Fighters due to Truss System Failures
          • Fire fighters may be injured and killed when fire-damaged roof and floor truss systems collapse, sometimes without warning.
          • The National Institute for Occupational Safety and Health (NIOSH) requests assistance in preventing injuries and deaths of fire fighters due to roof and floor truss collapse during fire-fighting operations. Roof and floor truss system collapses in buildings that are on fire cannot be predicted and may occur without warning.
          • NIOSH recommends that fire departments review their occupational safety programs and standard operating procedures to ensure they include safe work practices in and around structures that contain trusses. Building owners should follow proper building codes and consider posting building construction information outside a building to advise fire fighters of the conditions they may encounter.
          • ALERT Report HERE
          • National Near Miss Reporting System (NNMRS) Operating Experience
            • The National Fire Fighter Near-Miss Reporting System is a voluntary, confidential, non-punitive and secure reporting system with the goal of improving fire fighter safety.
            • Submitted reports will be reviewed by fire service professionals. Identifying descriptions are removed to protect your identity. The report is then posted on this web site for other fire fighters to use as a learning tool.
            • National Fire Fighter Near-Miss Reporting System Web Site, HERE
            • Search Reports, HERE
            • Resources, HERE
            • Prince William County (VA) Fire Rescue Kyle Wilson LODD Report-Remembrance and Learning’s HERE
              • Resources and Report
              • LODD Report Fact Sheet (23.9kb)
              • LODD Investigative Report (9.16 mb)
              • LODD Report Presentation (6.65 mb)
              • LODD Report Basic House Model (Section 1) (1.87 mb)
              • LODD Report Fire Model (Section 3) (5.16 mb)
              • LODD Flashover Chart (60 kb)
              • Prince William County (VA) Fire and Rescue Web Site, HERE
              • NIOSH LODD REPORT: Career fire fighter dies in wind driven residential structure fire – Virginia, HERE
              • NIST Fire Fighting Tactics Under Wind Driven Conditions: Laboratory Experiments
                • A series of experiments was conducted in our Large Fire Laboratory to examine the impact of wind control curtains and externally applied hose streams on a wind driven fire.  The results from these experiments will allow us to better understand the fire dynamics within a structure and provide guidance as to the important measurements needed in the future experiments in a high-rise on Governor’s Island in New York City.
                • Fire Fighting Tactics Under Wind Driven Conditions Report, HERE
                • Reference Data HERE
                • Colerain Township Eleven Minutes to Mayday; What You Need to Know HERE
                  • Colerain Township Department of Fire and Emergency Medical Services, Web Site HERE
                  • Investigation Analysis of the Squirrels nest Lane Firefighter Line of Duty Deaths April, 2010 Full Report HERE
                  • NIOSH Fire Fighter Fatality Investigation Report F2008-09| CDC/NIOSH July, 2009, Report HERE
                  • WLTW.com news report Summary HERE
                  • Charleston Sofa Super Store Fire; Final NIST Report
                  • Analytical Study Reveals Patterns in U.S Firefighter Fatalities Report 
                    • The entire report is available at a nominal fee, HERE; 
                    • Journal Reference: 
  1. Kumar Kunadharaju, Todd D. Smith, David M. DeJoy. Line-of-duty deaths among U.S. firefighters: An analysis of fatality investigations. Accident Analysis & Prevention, 2011; 43 (3): 1171 DOI: 10.1016/j.aap.2010.12.030

 

Training Drill Template

This Training Schedule Template utilizes a Three Hour, Thirty minute (3.5) Hour Format integrating Suggested basic Functional Area Topics as a lead-in introduction that can be interchanged based on local needs and incorporates two (2) primary modules of the IAFF Fire Ground Survival Program (FGS). Please note you can select any modules determined to be of local need or interests. An optional Weekend Session is attached for FGS Chapter 3 and 4 Module Deliveries and a Hands-on Field Exercise Component.

Go HERE for the Color PDF Format

Safety Week 2011: Surviving the Fire Ground-Fire Fighter, Fire Officer & Command Preparedness

Functional Area 3.5 Hour Schedule with FGS Modules

Time

Hour Functional Area Key Issues and Considerations

Reference and Links

00:30 1 Fire Fighter Life Safety Initiatives Procedures, Policies and Guides
  • Discuss and facilitate discussion on organizational

 

  • Review key SOPs & SOGs related to Fire Ground Operations culture and safety

 

  • How does Safety Week 2001 fit into your operational environment?

 

  • Agency Mission Statement
  • Overview & Explanation: View | Download 
  • Initiative 1: CultureView | Download 
  • Initiatives 1 – 4View | Download 
  • Initiatives 5 – 8View | Download 
  • Initiatives 9 – 12View | Download 
  • Initiatives 13 – 16View | Download
  • Agency SOPs, SOGs, Policies
  • Agency Expectations
  • Company Expectations or Gaps
  • What defines your level of preparedness?
00:30 Building Construction
  • Discuss pertinent issues relate to Building Construction that is present in your area

 

00:30          

 

2

Review FGS Chapter 1; Preventing the Mayday  Modules 1-1 thru 1-4
  • Mayday Prevention
  • Pre-Planning
  • Building Construction
  • UL Structural Stability
  • LT Wt. Truss Systems
  • Overhead Hazards

 

00:30 Review FGS Chapter 1;  Preventing the Mayday Modules 1-5 thru 1-8Continued
  • Mayday Prevention
  • Pre-Planning
  • Building Construction
  • UL Structural Stability
  • LODD Reports
  • Interior Size up
  • Reading Smoke
  • Air Management
  • Defensive Operations
  • Situational
  • Awareness
  • Rapid Heat Release
  • Fire Suppression OPS
  • NIST Fire Modeling

 

00:30 3 Review FGS Chapter 2;Mayday Ready Modules 2-1 thru 2-3
  • Preparing for the Mayday
  • Are You Ready?
  • Mayday Training
  • Personal safety Equipment
  • Tools & Equipment
  • Mission Critical Resources

 

00:30 Review FGS Chapter 2;Mayday Ready Modules 2-4 thru 2-5Continued
  • Three Point Communications
  • Role of Dispatch
  • Personal Radio Position
  • Communications Training
  • Radio Discipline
  • Comm Order Model
  • Portable Radios
  • Why “Mayday?”
  • Accountability

 

00:30 4 Wrap-up and Closing Discussions
  • Facilitate discussion on the presentations
  • Are there any identified gaps or identified areas for improvement?
  • How will the information presented be implemented during future shifts or operations?
  • What level of individual and/or company level accountability can be implemented?
  • How can the organization become safer and effective to minimize and reduce risk to mayday events to improve fire ground survivability?
  • Agency Specific and/or developed or;
  • Utilize  resources from the Functional Matrix
 
00:00  
  •  
  •  
 

Fire/EMS Safety, Health and Survival Week 2011, Day Six; From Waldbaum’s to Hackensack-Worcester to Charleston; Legacies for Operational Safety

3 comments

Fire Service Tradition and The Brotherhood

For those of you that follow or have attended one of my many seminar and lecture program offerings, one program seems very pertinent in both context and content on this, the Sixth Day of Fire/EMS Safety Week 2011 that resonates around the theme and focus of Surviving the Fire Ground – Fire Fighter, Fire Officer and Command Preparedness.

“From Waldbaum’s to Hackensack-Worcester to Charleston; Legacies for Operational Safety”; in most cases, any discussion of these four landmark incidents in the fire service leads directly to a rich discussion and dialog on a myriad of facets, aspects and issues characteristic of the incidents; the time, the place, the circumstances, the names and faces, the deployment, the operations, the challenges and the tragic outcomes.

The legacies of these iconic events as well as so many others of national prominence and impact; and others with lesser national significance, but having far reaching implications, impacts and power on the regional and local levels continue to shine in the remembrance, honor and memory of those impacted by those events and incidents.

I still find it astonishing during my lecture travels around the country lecturing and presenting these programs on building construction and fireground operations, that when those in attendance were posed with a simple question; “What do the Walbaum’s Fire and Hackensack fire share in common?”, the response at times was less than stellar, or at best difficult to solicit let alone convey the commonalities.

The more seasoned and experienced veterans (translation; older firefighters) when present, were able to convey some information on the subject – Some, with a firm and reflected understanding of the question and its ramifications, others not so much. But yet, the true essence of the basic incident particulars and the lessons learned in most cases failed to be fully conveyed. It’s sad to state but; we are not remembering the past!

History Repeating Events-Integrate into your Training

 

Are the fire service legacies of the past and the lessons learned from those incidents and the sacrifices that were made transcending time? Or are they lost in the immediacy of day to day challenges, issues and operations.

Or are these events, lessons and operations issues dismissed and disregarded as a result of their “time and place” not being relevant to “today’s” operations and modern fire service advancements or lack the relevancy to local organizations, operations, make-up and risks. Is it just a “Big City” issue or is it a failure to comprehend the commonality of the event parameters and distill those lessons learned and operations into the essence that is formulative of all of our organizations and operations?

Surviving the Fire Ground – Fire Fighter, Fire Officer and Command Preparedness, has a multitude of facets, features and functional elements. I spoke of some of these commonalities in a previous post this week on Day Two (HERE).

I’ve spoken on numerous occasions about History Repeating Events (HRE), and the common themes related to fire fighter line-of-duty deaths, close-calls, near-misses, maydays and incident operations that had less than desirable outcomes or performance.

These History Repeating Events and incidents on a wide variation of scale, outcome and operations have common issues, apparent and contributing causes and operational factors that share legacy issues that the fire service at times fails to identify, relate to and implement. In other words, (we) fail a times to learn from the past or we make a deliberate choice to ignore those lessons and the apparent similarities and prevailing fireground indicators due to other internal or external influences, pressures, authority, beliefs, values or viewpoints.

What are we Learning? What are we Applying?

We make choices and we determine our direction, path and destiny. Officers, Commanders, Companies fail to connect with situational factors, parallels and signs that have the full potential to direct the incident towards favorable or disastrous conclusions.  The Job isn’t as fatalistic as we sometimes make it out to be.

The prevailing topical areas being addressed this year during Safety week have focused on the mayday component of an incident operation and have included:

  • Preventing the Mayday: situational awareness, planning, size up, air management, fitness for survival, defensive operations.
  • Being Ready for the Mayday: personal safety equipment, communications, accountability systems.
  • Self-Survival Procedures: avoiding panic, mnemonic learning aid “GRAB LIVES”— actions a fire fighter must take to improve survivability, emergency breathing.
  • Self-Survival Skills: SCBA familiarization, emergency procedures, disentanglement, upper floor escape techniques.
  • Fire Fighter Expectations of Command: command-level mayday training, pre-mayday, mayday and rescue, post-rescue, expanding the incident-command system, communications.

There’s ample opportunity this week or in the weeks ahead to do some insightful research or cull some information on the four legacy events we discussed earlier;

  • FDNY Waldbaum’s Fire (1978) HERE and HERE
  • Hackensack (NJ) Auto Dealership Fire (1988) HERE and HERE
  • Worcester (MA) Cold Storage Fire (1999) HERE and HERE
  • Charleston (SC) Sofa Super Store (2007) HERE and HERE

These have tremendous Legacies for Operational Safety, lessons and a wealth of applications for Safety Week and for training, dialog, discussions, tabletops, skillsets and drill activities throughout the entire year.

Integrate the lessons from these as well as other legacies and HRE into your Surviving the Fire Ground – Fire Fighter, Fire Officer and Command Preparedness; training and deliveries. The reality is, we, the present generation of veteran firefighters and officers have the profound obligation and responsibility to recognize the importance of passing along the lessons of the past as well as integrating and playing forward the lessons of our life’s journey throughout our fire service careers; the events of our day and the profound tough lessons and sacrifices learned the hard way. Understand and embrace the shared responsibilities, accountability and requirements that contribute towards Surviving the Fire Ground.

We sometimes need a receptive, sympathetic and compassionate audience that is willing to listen, hear and comprehend the messages conveyed. There needs to be a high degree of empathy related to these past History Repeating Events, the legacies of national, regional and local level prominence. For each event, each and every line of duty death, close-call, near-miss and mayday event has a message and a Legacy of Operational Safety.

Make the time to research, learn and understand the factors of these events, the lessons and opportunities that are borne from each and how they relate to the theme, message and initiatives that make up Fire/EMS Safety, Health and Survival Week and beyond.

Here’s a great Resource from FDNY’s 2011 Safety Initiatives,  SurvivingtheFireground_SafetyWeek2011(2)_0

Prepare for the When, not the IF

Fire/EMS Safety, Health and Survival Week 2011: Day Five: Near-Misses, Maydays and Floor Collapses

1 comment

Do you know what's underneath you as you're making entry?

During the last quarter of 2010 and leading well into the second quarter of 2011 there has been a significant emerging trend developing in basement fires, compromised floor systems and assemblies leading to collapse and numerous near-miss events, close calls and unfortunatly, line of duty deaths during fire operations.

If you’ve been paying attention to the various news and on the job reports these past number of months, you may have noticed the increasing numbers of emerging trend evident in near miss, close-calls resulting in maydays, RIT deployments and self-rescue resulting from floor compromise and floor collapse. The double line of duty deaths of two San Francisco (CA) Fire fighers while operating in a Terraced (Hillside construction) residential occupancy while operating below the base level diaphragm (upper street level access). (HERE)

In December 2010,  I was doing some research and posting links related to the first one or two events on Buildingsonfire on Facebook, HERE, it became evident at the time that there was an immediate opportunity to get some learning’s and insights out. If you have a chance head over to Facebook and link into Buildingsonfire and check out the incident links posted as well as some immediate report links. (Demember 2010 time frame)

In a coincidential posting on July 28, 2010, I posted on CommandSafety.com an interesting incident that I came across while preparing for a new post related to a near-miss event that occured in which a Camp Taylor (KY) firefighter survived a floor collapse that momentarily trapped him proximal to the seat of a working basement fire. Camp Taylor (FD) Captain Michael Long sustained second and third degree leg burns after falling through the floor of the burning home and subsequently being rescue by other fire department personnel after calling a mayday.

This event has all the ingrediants the the 2011 Safety Week focus on Surviving the Fire Ground and managing the Mayday. Little did I know that later, in February 2011, while participating in the National FireFighter Near-Miss Reporting System Stakeholders meeting in California, would I have the chance to hear Captain Long’s story first hand, and then also have the opportunity to have him as a guest, sharing his story live on the Taking it to the Streets Radio program in February. (HERE)

Camp Taylor (FD) Captain Michael Long’s near-miss and story of survival resonates with this year’s theme of  Surviving the Fire Ground- Firefighter, Fire Officer and Command Preparedness and Managing the Mayday and provides an opportunity to focus on the event in this, Day Five of the 2011 Fire/EMS Safety, Health and Surival Week activities. The details of Captain Long’s story can be found on the National FireFighter Near Miss Reporting System web site (HERE) as well as in the June 2011 issue of Fire Engineering Magazine titled, Floor Collapse: A Survivors Story. Let me state upfront also the Captain Michael Long will be presenting the accounts of his near miss event and the lessons-learned at IAFC Fire-Rescue International Conference in Atlanta in August (HERE).

 On July 25, 2010, Captain Michael Long of the Camp Taylor (Ky.) Fire Protection District fell through the floor of a house during a four-alarm fire and suffered severe burn injuries. On Aug. 30, 2010, Capt. Long submitted a near-miss report based on this event. The National Fire Fighter Near-Miss Reporting System is an anonymous and confidential reporting system; however, Capt. Long wanted to have his name associated with this report so that others would understand the value of sharing near-miss events. What follows is an excerpt from his report and excerpts from a recent phone interview. To read his full report, including an extensive lessons learned section, search by report number for report #10-1072 on the Search Reports page of www.firefighternearmiss.com.

  

Near Miss Report Event #2010-1072

  

 “I made sure my crew was ready to enter, sounded the floor for stability and then crossedover the threshold, entering the structure. When I was approximately 5 feet inside the structure, I felt the floor start to give way. I turned toward the front door to try to bail out, and at the same time yelled at others to get out, when the floor system collapsed. This was no ordinary collapse. More than two-thirds of the first floor collapsed simultaneously. The living room, dining room, kitchen, bathroom and foyer all fell at once. “When the collapse happened, I was the only one who fell into the basement, right into the heart of the fire. All I could see around me were flames.

I could not see the hole that I had fallen through. I could not see my fellow firefighters above me. All I could see was fire. I began to try to find something to use to climb back up with. Since I did not know what type of collapse had occurred, I just started clawing away at anything as I was trying to climb. During this time, my legs were burning.

Fire was burning up between my boots and my bunker pants. The pain was intense. My deputy chief was trying to put a line on me for protection, but the fire was extremely intense. He was lying on the porch with fire shooting out over his head. He stated he could occasionally see the top of my helmet and the reflective stripes on my coat sleeves.

By a bit of luck, a roof ladder was laying in the front yard that had just been taken off the roof after the completion of a ventilation operation.

My deputy chief directed the crew to put the ladder into the hole for my escape. “By this time, I was burned on my legs and struggling with exhaustion and the intense heat. I was screaming both from pain and due to fear. I could hear screaming coming from above, butwas unable to make out the majority of it. I finally heard the word “ladder” and then felt something across my back. Once they got the ladder into the basement, I had to get around to it. I still could not see anything but fire, so this was all by feel. As I started up the ladder, I got two rungs up, reached for the third rung, and lost my grip and fell back into the basement landing on my back. I was so exhausted that I started making my peace with God that this was where I was going to die.

For the full excerpt from Captain Long’s near miss report go to the NFF Near Miss Reporting Site and Resource Link, HERE

  

Captain Long

Incident Lessons Learned from Captain Long:

  • Train as if it is real. Train, train, train, and then train some more. Take advantage of every opportunity to train. The better we are trained, the less our chance of injury. The training must be physically and mentally. Crews must focus on more hands-on scenario-based training that allows for problem solving. If crews are taught that the outcome to every scenario is static, they are not being encouraged to think. Every run is different; no single solution applies to every situation. Adaptations or decisions that are not in step with changing conditions can actually be disadvantageous. We must make the right decisions based on the correct interpretation of the environment and blend those observations with our knowledge, skills, and abilities to map a course of action that will lead us to a successful outcome. Read reality and come up with the best possible plan. In my situation, quick thinking and adapting to the problem that presented itself saved my life.
  • Mutual-aid training is a must. We must train more with our neighboring departments to improve operations. It is occasionally difficult to work in situations where you do not really know with whom you will be working or where the command structure and tactics differ from those of your department. We all learn from the same book; however, the interpretations and tactics differ from person to person and department to department. I am not saying anyone is right or wrong in the way they do things—we all just need to do a better job of understanding that there is more than one way to get the job done.
    We cannot know exactly how everyone on an emergency scene will perform because each person has a different interpretation of his surroundings and role in the system. Standard operating guidelines (SOGs) can assist in this area, but SOGs rely on perceptions and interpretations by individuals to be implemented as intended. Accidents often happen because everyone has a unique perspective on the environment, and each makes different decisions based on their perception.
    We must perceive the environment correctly to ensure we make the right move. If these actions are not communicated and coordinated in the intricate system that is the fireground, accidents will be the inevitable and regrettable results. Training and frequent reviewing of SOGs are vital to our safety.
  • Risk assessment. Sounding the floor prior to entry is not always a good indicator of the floor’s stability. Less than two minutes before I made entry, there were three other firefighters, at least the same weight as I, in the same area where the collapse occurred. Everything changed in a very short time. There was no warning. Adkins told me at the hospital that all he heard was a “whoosh” sound when the floor collapsed. Then I disappeared. Within two minutes, the floor assembly went from being able to sustain a live load of at least 900 pounds in that area (accounting for gear, equipment, SCBA, and so on) to collapsing with about a 300-pound load, and I was close to a load-bearing wall. A good way to evaluate risk vs. gain is to get the most accurate report on burn time as possible to help determine structural integrity.
  • Rapid intervention. RIT is a critical fireground benchmark and is very important for safety, but it would have been ineffective in this situation. Had my crew not reacted the way they did immediately, I would not have been able to last long enough to wait for the RIT. In the time it would have taken for the RIT to gear up, come up with a plan, and enter, I would have died. The stars aligned in my favor that night. The person calling the Mayday or a nearby crew often mitigates personnel emergencies. My crew was able to act decisively at the correct time, and I am alive because of it. It is important to remember that a large percentage of Maydays are mitigated by the crew to which the lost firefighter is assigned or a nearby crew. RIT deployments account for a small number of rescues; we must always be alert and ready for the “incident within the incident.”
  • Manage your emotional response. From a personal standpoint, you must rely on your training and try not to panic. Know your equipment and procedures well. I did panic, but I was still able to keep myself together enough to know not to leave the area since I had been told that the stairs had burned away. Keeping my SCBA on, resisting the emotional reaction to remove my mask because of claustrophobia, was a huge factor in my survival. If I had tried to find another way out, my crew could not have gotten to me with the ladder. Had I removed my mask, the story would have ended quite differently. When I teach, I try to train as if it is the real thing. Never take a run for granted. Always expect the worst; you will be better prepared to deal with the unexpected.
    If we continually study accident reports and learn from them, the likelihood of being surprised will be diminished. Peter Leschak writes in Ghosts of the Fireground: ”In fire and other emergency operations, you must not only tolerate uncertainty; you must savor it, or you won’t last long. The most efficient preparation is a general mental, physical, and professional readiness nurtured over years of training and experience. You live to live. Preparing is itself an activity, and action is preparation.”
  • Talk about it. Critical incident stress debriefing (CISD) is important for ensuring that personnel from all departments on scene are taken care of emotionally. CISD needs to extend beyond just one or two briefings. Personnel involved in a highly emotional event must be given the opportunity to speak to a trained CISD team member early and be given as much time as is needed to work through their issue. Some firefighters have a macho attitude and try to deal with their emotions on their own, or maybe they don’t deal with them at all. Others self-medicate with alcohol or, worse, these difficult emotional events are allowed to fester with no relief. People should be accepting of those who deal with issues up front and tell their stories. Telling these stories makes us better and helps to keep us safe. This reduces the possibility of “snapping” because you have too much pent-up emotion.
    My fellow firefighters are still affected by this event, even those who were not there. Department personnel must be open-minded and receptive to the fact that emotional events will affect your performance and your personal life and that it is acceptable to be open and deal with them. When difficult emotional situations present themselves, members should attempt to deal with them as soon as possible.
  • Know what is possible and what is not. Know the experience level of your crew. Going into a bad situation with a crew that may not have exposure to a lot of different situations or that you aren’t that familiar with could make operations more difficult. I had everything from a 30-year veteran to a one-year recruit, so the experience level was all across the board. I knew that the situation we were going into was getting worse and required quick action, so I took the lead to ensure that the operation would be completed as quickly as possible. I knew my deputy chief would be watching us to ensure things were proceeding safely. I knew my crew could get the job done; however, this was an operation that is not often practiced and I wanted to make sure it was done correctly. I will not send my crew into an area that I am not comfortable going into. The more you train and the more people you can train with, the better you will understand your capabilities.

 Listen or download the special interview I had with Captain Mike Long as well as

Taking it to the Streets Radio Program and Interview with Capt. Long

 

Taking it to the StreetsTM is a monthly radio show featured on BlogTalk Radio and is hosted by nationally renowned fire service leader Christopher Naum, a  36-year fire service veteran and highly regarded national instructor, author, lecturer and fire officer and  the distinguished leading  national authority on building construction and fire ground operations.  Taking it to the StreetsTM is a Buildingsonfire.com Series and FireFighternetcast.com Production,   © 2011 All Rights Reserved 

Taking it to the Streets: Near Miss Reporting and One Captain’s Close Call

Podcast: Play in new window | Download

The progam was taped from the Live Broadcast on March 16th at 9pm EST

Taking it to the Streets: Near Miss Reporting and One Captain’s Close Call

On Your Street, In Your City, Across the Country, Around the WorldTM

The direct show link is here

The line-up of Program guests included, Lt. Steve Mormino, FDNY (ret), Captain CJ Haberkorn Denver (CO) Fire Department and Special Guest Captain Michael Long, Camp Taylor (KY) Fire Protection District.

Grab a cup of coffee and sit down for a special two part, two hour program with Taking it to the Streets on Firefighernetcast.com where we’ll be discussing the National Near-Miss Reporting System and the untapped resources that the program and system provides with Christopher Naum and this outstanding group of fire service leaders. The second part of the program will dedicated to the personal account of Captain Long’s Close Call event from July 25, 2010 (NMR #10-1072) when a catastrophic floor collapse at a residential occupancy plunged him into a fire involved basement.

Check out the latest downloads of recent programs in the archives by visiting Taking it to the Street’s webpage on Firefighternetcast.com or for program insights at CommandSafety.com.    

  • Firefighternetcast.com HERE
  • Taking it to the Streets Radio Programs, HERE and HERE 
  • Buildingsonfire.com, HERE  

Taking it to the StreetsTM, radio program hosted by highly regarded national instructor, author, lecturer and fire officer Christopher Naum, continues to provide provocative insights and dynamic discussions with leading national fire service leaders and guests on important issues affecting the American Fire Service with applications internationally within the tradition and brotherhood of the Fire Service.

Taking it to the StreetsTM, is a Buildingsonfire.com Series and Firefighter Netcast.com Production, in affiliation with the Command Institute

 

National Fire Fighter Near Miss Reporting System’s Support for the 2011 Safety Week

Don’t forget to go to the National Firefighter Near Miss Reporting System for  number of exceptional training aids, resources, PPT and more. NFFNMRS, HERE

Here are some of the National Firefighter Near Miss Reporting System Produced 2011 Safety Week Products

 
File Title File Size File Description
  • Presentation: Preventing The Mayday
  • 176 KB A powerpoint presentation about situational awareness, planning, size-up, and defensive operations
  • Presentation: Being Ready for the Mayday
  • 176 KB A powerpoint presentation about personal safety equipment, communications, and accountability systems
  • Presentation: Fire Fighter Expectations of Command
  • 176 KB A powerpoint presentation about fire fighter expectations of command.
  • Presentation: Self-Survival Skills
  • 176 KB A powerpoint presentation about self survival skills at a mayday.
  • Presentation: Self-Survival Procedures
  • 176 KB A powerpoint presentation about self survival procedures.
  • Grouped Report: Preventing The Mayday
  • 176 KB A grouped report about situational awareness, planning, size-up, and defensive operations
  • Grouped Report: Self Survival Procedures
  • 176 KB A grouped report about self survival procedures
  • Grouped Report: Being Ready for the Mayday
  • 176 KB A grouped report about personal safety equipment, communications, and accountability systems

    In the meantime here are some links I pulled together that you should take the time to read and share with your companies, personnel and staff…..

    This seems like a good time to have a ten minute drill on these events as Operating Experience (OE) on floor systems and operational safety, calling or commanding the mayday.

     Or take some time to visit the The IAFF Fire Ground Survival Program (FGS)site which has the most comprehensive survival-skills and mayday-prevention program currently available and is open to all members of the fire service. Incorporating federal regulations, proven incident-management best practices and survival techniques from leaders in the field, and real case studies from experienced fire fighters, FGS aims to educate all fire fighters to be prepared if the unfortunate happens.  (Day One: Are you ready, HERE)

    • For links to the IAFF Fire Ground Survival Program, HERE and HERE

    Self-Survival Procedures

    FGS Online Program Chapter 3
    To improve survivability in a Mayday situation, a fire fighter must know how to alert rescuers to his or her location and perform self-survival techniques. Through the study of fire fighter fatalities, NIOSH has identified specific actions fire fighters can take to help save themselves. Variations of this same NIOSH recommendation have appeared in numerous fire fighter fatality reports. These recommendations were used to create a self survival procedure that is easy to remember using a mnemonic (GRAB LIVES). Following these steps increases the likelihood of the rescuers finding and assisting the fire fighter to safety.
    When a fire captain died when trapped by partial roof collapse in a vacant house fire in Texas, NIOSH recommended in report number F2005-09 that trapped fire fighters should:

    • First, transmit a distress signal while they still have the capability and sufficient air.
    • Next, manually activate their PASS device. To conserve air while waiting to be rescued, try to stay calm and avoid unnecessary physical activity.
    • If not in immediate danger, remain in one place to help rescuers locate them.
    • Survey their surroundings to get their bearings and determine potential escape routes.
    • Stay in radio contact with the IC and other rescuers.
    • Attract attention by maximizing the sound of their PASS device (e.g., by pointing it in an open direction); pointing their flashlight toward the ceiling or moving it around; and using a tool to make tapping noises on the floor or wall. 

    Self-Survival Skills

    FGS Online Program Chapter 4

    Disentanglement Maneuvers

    Fires inside an enclosed structure create a mess for fire fighters operating on the floor. Fire fighters often encounter debris that has fallen off shelves, and ceiling and wall fixtures that have burned and are left hanging to the floor. These hazards, coupled with the mess a fire fighter creates when searching for victims in smoky environments, can create egress problems for a fire fighter.

    As fire burns draperies, blinds, lighting fixtures, computer wiring, and HVAC ducting, the possibility of encountering an entanglement hazard increases. The overhead ducting of the HVAC system contains wires that give the ducting its stability.

    If a fire breaches the ceiling and burns the ducting, the wires within the ducting fall to the floor. These wires can cause a dangerous entanglement hazard to fire fighters operating on the floor. Fire fighters must anticipate these hazards and have a plan to follow when egress is cut off.

    NIOSH Alert: Preventing Injuries and Deaths of Fire Fighters

    Fire Fighter Expectations of Command

    FGS Online Program Chapter 5
    A discussion of what command must communicate to the distressed fire fighter, dispatch, the RIT group supervisor and all others assigned to the incident to assure a successful rescue.

    Here are Some Mission Critical Reference Links for Operational Insights and Operating Experience (OE) to support Your Training and Operational Needs not only this week, but through the entire year.

     

    Here are some Safety Considerations related to Residential Occupancies (non-inclusive) for Operations at Basement Fires that will support fireground operational safety:

    • Conduct a thorough fire size-up and communicate the findings to all personnel on-scene before entering the building.
    • Conduct an assessment of the Building Profile ( building construction type, structural assembly systems and features and age) and assesss fire behavior and intensity levels.
    • Ensure an adequte Risk Assessement is conducted and that Risk versus Gain is determined
    • Maintain situational awareness throughout the tactical deployment of crews within the interior of the structure
    • Conduct a 360 degree perimeter assesement when feasible to determine access and egress points, fire location and travel and other mission critical operational perameters.
    • Incident commanders and company officers should be trained and experienced in structure fire size up to avoid putting fire fighters at unneeded risk of working above fire-damaged floors.
    • Do not enter a structure, room, or area when fire is suspected to be directly beneath the floor or area where fire fighters would be operating, or if the location of the fire is unknown.
    • Never assume structural safety of any floor (regardless of the construction) having a significant fire under it.
    • Conduct pre-incident planning inspections during the construction phase to identify the type of floor construction.
    • If pre-planning is not conducted, assume residential construction and small commercial buildings built since the early 1990s may contain engineered wood I-joists.
    • Report construction deficiencies noted during preplanning to local building code officials. For example, engineered wood floor joists should only be modified per manufacturer specifications—usually limited to cutting to length and removing pre–cut knockouts for utility access. Report damaged or cut chords or webs to building officials.
    • Develop, enforce, and follow standard operating procedures (SOPs) on how to size up and combat fires safely in buildings of all construction types. Rapid intervention teams (RIT) should include a portable ladder with their RIT equipment when deployed at basement fires.
    • Ensure Time Compression is considered: Ensure Command has the ability to monitor progress or elapsed incident time and adjusts strategic and tactical plans accordingly and in a time effective manner. 
    • Provide training on identifying signs of weakened floor systems (soft or spongy feel, heat transmitted through floor, downward bowing, etc.).
    • Make fire fighters aware that all floor types can fail with little or no warning.
    • Use a thermal imaging camera to help locate fires burning below or within floor systems, but recognize that the camera cannot be relied upon to assess the strength or safety of the floor. (Refer to the recent UL Test Data and Operational Safety Considerations ”Structural Stability of Engineered Lumber in Fire Conditions” available at http://www.uluniversity.us/ )
    • Fire fighters should be trained on the use of thermal imaging cameras, including limitations and difficulties in detecting fire burning below floor systems. (See reference to UL above)
    • Immediately evacuate and, if possible, use alternate exit routes when floor systems directly beneath the floor where fire fighters would be operating are weakened by fire.
    • Use defensive overhaul procedures after fire extinguishment in structures containing fire-damaged floor systems of all types.
    • Consider becoming active in the building code process and influence requirements for fire resistance of floor and ceiling systems to further fire fighter safety and health.
    • Ensure RIT personnel area staged and have complete a site assessment of the building and occupany upon thier arrival and set-up
    • Ensure that a rapid intervention team (RIT) is on the scene as part of the first alarm and in position to provide immediate assistance prior to crews entering a hazardous environment

    Here’s some screen shots from Buildingsonfire on Facebook. Go HERE or follow the link at the left column. Join the growing list of over 3900 fans with Buildingsonfire on Facebook and Buildingsonfire.com

    Fire/EMS Safety, Health and Survival Week: Day Four -The New Fire Ground

    4 comments

    Fire/EMS Safety, Health and Survival Week: Day Four -The New Fire Ground    

     

    There is an immediate need for today’s emerging and operating command and company officers to increase their foundation of knowledge and insights related to the modern building occupancy, building construction and fire protection engineering and to adjust and modify traditional and conventional strategic operating profiles in order to safeguard companies, personnel and team compositions.

    Strategies and tactics must be based on occupancy risk, not occupancy type, and must have the combined adequacy of sufficient staffing, fire flow and tactical patience orchestrated in a manner that identifies with the fire and building profiling, predictability of the occupancy profile and accounts for presumptive fire behavior. It is not your old method of size-up and operational deployment.

    The dramatic changes in buildings and occupancies over the past ten years have resulted inadequate fire suppression methodologies based upon conventional practices that do not align with the manner in which we used to discern with a measured degree of predictability how buildings would perform, react and fail under most fire conditions. These past presumptions, which many of us debated with our esteemed colleagues, are being validated through empirical data resulting from the cutting edge research and testing being conducted today by UL and NIST.

    Predicting Fire Behavior and Building Stability

    We predicate certain expectations that fire will travel in a defined (predictable) manner that fire will hold within a room and compartment for a predictable given duration of time; that the fire load and related fire flows required will be appropriate for an expected size and severity of fire encountered within a given building, occupancy, structural system and given an appropriately trained and skilled staff to perform the requisite evolutions, we can safely and effectively mitigate a structural fire situation in any  given building type and occupancy.

    • Past operational experiences, both favorable and negative; gave us experiences that define and determine how the fireground is assessed, react and how we expect similar structures and occupancies to perform at a given alarm in the future; this formed the basis for the naturalistic decision-making process.

    Implementing fundamentals of firefighting operations built upon nine decades of time-tested and experience-proven strategies and tactics continues to be the model of suppression operations. These same fundamental strategies continue to drive methodologies and curriculums in our current training programs and academies of instructions.

    Are you aware of the defining changes in structural systems and support, the degree of compartmentation,

    • the characteristics of materials and the magnitude of the fire-loading package in today’s buildings and occupancies?
    • When was the last time you were out in the street with the companies, or spent some time doing a walk-through of construction or renovations site?
    • Have you asked you commanding officers, division or battalion chief or your company officers for insights into what operational demands and risks are being imposed upon them while operating in the street and within the buildings, occupancies and structures that comprise your jurisdiction?

    The structural anatomy, predictability of building performance under fire conditions, structural integrity and the extreme fire behavior; accelerated growth rate and intensively levels typically encountered in buildings of modern construction during initial and sustained fire suppression have given new meaning to the term combat fire engagement.

    It’s no longer just brute force and sheer physical determination that define structural fire suppression operations, although any seasoned command and company officer knows that at times. It’s what gets the job done under the most arduous and demanding of circumstances.

    However, from a methodical and disciplined perspective; aggressive firefighting must be redefined and aligned to the built environment and associated with goal-oriented tactical operations that are defined by risk assessed and analyzed strategic processes that are executed under battle plans that promote the best in safety practices and survivability within known hostile structural fire environments.

    The demands and requirements of modern firefighting will continue to require the placement of personnel within situations and buildings that carry risk, uncertainty and inherent danger. As a result, risk management must become fluid and integrated with intelligent tactical deployments and operations recognizing the risk problematically and not fatalistically, resulting in safety conscious strategies and tactics.

    Today’s incident commanders need to think about the Predicative Strategic Process, refined Tactical Deployment Models integrating intelligent Structural Anatomy and Predictive Occupancy Profiling, while implementing Tactical Patience.

    Think about the following;

    • Read, comprehend and implement the new IAFC The Rules of Engagement for Firefighter Survival and The Incident Commanders Rules of Engagement for Firefighter Safety
    • Take a tour of your response area, district, community or city.
    • Take a good look around and begin to recognize the apparent or subtle changes that are affecting your incident operations; Take note and think about what needs to be adjusted, modified or changed in your operations.
    • Read up on the latest research and technical literature on wind driven fires, extreme fire behavior, structural ability of engineered lumber systems, fire loading and suppression theory
    • Take the time to personally read a series of the latest NIOSH Fire Fighter Fatality Investigation and Prevention Program LODD reports and relate them to your organizations operations and jurisdictional risks.
    • Start thinking in terms of Occupancy Risks versus Occupancy Type and align your operations and deployments to match those risks
    • Increase your situational awareness of today’s fireground and refine your strategic and tactical modeling
    • Implement both Strategic and Tactical Patience; Slow down and allow the building to react and stabilize, for fire behavior to stop behaving badly and for your companies to increase survivability ratios while meeting the demands of  conducting fire service operations
    • Think about Adaptive Fire Ground Management and Command Resiliency
    • Reprogram your assumptions and presumptions and options on building construction and firefighting operations; the buildings have changed, our firefighting has not; what are you going to do about that gap?

    If you don’t fully understand how a building truly performs or reacts under fire conditions and the variables that can influence its stability and degradation, movement of fire and products of combustion and the resource requirements for fire suppression in terms of staffing, apparatus and required fire flows, then you will be functioning and operating in a reactionary manner that is no longer acceptable within many of our modern building types, occupancies and structures.

    This places higher risk to your personnel and lessens the likelihood for effective, efficient and safe operations. You’re just not doing your job effectively and you’re at risk. These risks can equate into insurmountable operational challenges and could lead to adverse incident outcomes. Someone could get hurt, someone could die, it’s that simple; it’s that obvious.

    Without understanding the building-occupancy relationships and integrating; construction, occupancies, fire dynamics and fire behavior, risk, analysis, the art and science of firefighting, safety conscious work environment concepts and effective and well-informed incident command management, company-level supervision and task-level competencies … You are derelict and negligent and “not “everyone may be going home”.

    It’s all about understanding the building-occupancy relationships and the art and science of firefighting, equating to Building Knowledge = Firefighter Safety.

      

    Taking it to the StreetsTM is a monthly radio show featured on BlogTalk Radio and is hosted by nationally renowned fire service leader Christopher Naum, a  36-year fire service veteran and highly regarded national instructor, author, lecturer and fire officer and  the distinguished leading  national authority on building construction and fire ground operations.  Taking it to the StreetsTM is a Buildingsonfire.com Series and FireFighternetcast.com Production,   © 2011 All Rights Reserved 

    Check out the latest downloads of recent programs in the archives by visiting Taking it to the Street’s webpage on Firefighternetcast.com or for program insights at CommandSafety.com.    

    • Firefighternetcast.com HERE
    • Taking it to the Streets Radio Programs, HERE and HERE 
    • Buildingsonfire.com, HERE

     A Buildingsonfire.com Series and Firefighter Netcast.com Production

      

    Taking it to the Streets had its premier July 21st on Firefighter Netcast.com with a lively and provoking discussion on “What’s on YOUR Radar Screen?” The program theme aligned with a recent posting on the same topic. Joining me on the program were two prominent and nationally recognized fire service leaders, who I’m honored to have known for many years, Chief Billy Hayes and Chief Doug Cline; the program explored leading fire service issues affecting firefighter safety, training, credentialing and education; fireground operational variables related to the continuing changes in building construction, engineered systems and extreme fire behavior,  and the emerging need for “Tactical Patience” as I’ve been exploring the relationships towards the need for tactical enhancements to our current fire suppression theory and firefighting models.

    Conversations expanded on the NFFF/Everyone Goes Home Campaign and programs, the newest EGH initiatives on Behavioral Health and the successes achieved through the Courage to be Safe Programs and the Advocacy Program.

    The Premiere of Christopher Naum’s “Taking It to the Streets”

    Podcast: Play in new window | Download

    Taking it to the Streets premiered  on  Wednesday July 21st 9:00pm ET

    Download the Program HERE

    The New Fire Ground

    NIST Wind Driven Fire Study

    • Smoke and heat spreading through the corridors and the stairs of a building during a fire can limit building occupants’ ability to escape and can limit fire fighters’ ability to rescue them.  Changes in the building’s ventilation or presence of an external wind can increase the energy release of the fire.  This can also increase the spread of fire gases through the building.  In some cases, such as the Cook County Administration Building fire in October 2003, the fire gas flow, into the corridors and the stairway prevented fire fighters from suppressing the fire from inside the structure.  This fire resulted in 6 building occupant fatalities and fire fighter injuries in the stairway.  The Fire Department of New York City has experienced many wind driven fire incidents which have resulted in fire fighter fatalities and injuries, as have a number of other incidents nationally that have resulted in increased research into this operational and tactical challenge.
    • What tactics or tools are appropriate for use with a wind driven fire and how should the tactics or tools be implemented?  Positive Pressure Ventilation (PPV) is being used by fire departments on smaller structures, such as single family homes, to control the fire flow by introducing pressure from the front door and venting the house through a strategic exit opening.  If done correctly, this tactic can remove significant amounts of heat and smoke from the structure, thus improving the fire fighters’ working environment and improving the chances of survival for the building occupants.  NIST has completed several studies which have a two fold impact: 1) providing guidance on the safe use of PPV and 2) characterizing and validating the modeling of PPV with a computational fluid dynamics (CFD) computer model, so that the model can be used as a training tool for the fire service.
    • This project extends previous work for ventilation under wind driven conditions.  There are many questions regarding wind driven fires.  For example can these PPV fans be used successfully under wind driven fire conditions in large structures?  Large structures, such as high rise buildings, provide additional challenges to fire fighter and building occupant safety: increased travel distance (exposure time), more complicated egress path, and potentially larger fires.  In 2002 there were 7,300 reported fires in high rise structures.
    • Other tactics incorporating devices, such as wind control devices (WCD) to control the ventilation conditions or the use of a “high rise” nozzle from the floor below the fire floor have been tried by the fire service under “real fire” conditions with varying levels of success.
    • A comprehensive free DVD set from the NIST includes a presentation video that explains PPV, examines the results of NIST’s PPV research, and closes with a focus on the use of PPV tactics in high-rise buildings.  All of the NIST PPV reports referenced in the presentation are included on Disc 1 of the set.  All of the videos from the high-rise fire experiments are also provided with a user-friendly, graphic menu that can be used on a PC or a DVD player.  NIST, with support from USFA, DHS, and fire departments across the country, has taken engineering principles and applied them to fire service PPV tactics in order to improve fire fighter safety
    • NIST References HERE and HERE

    NIST Fire Fighting Tactics Under Wind Driven Conditions: Laboratory Experiments

    • A series of experiments was conducted in our Large Fire Laboratory to examine the impact of wind control curtains and externally applied hose streams on a wind driven fire.  The results from these experiments will allow us to better understand the fire dynamics within a structure and provide guidance as to the important measurements needed in the future experiments in a high-rise on Governor’s Island in New York City.
    • Fire Fighting Tactics Under Wind Driven Conditions Report, HERE
    • Reference Data HERE

    NIST Firefighter Safety and Deployment Study; Report on Residential Fireground Field Experiments

    • The NIST Firefighter Safety and Deployment Study; Titled- Report on Residential Fireground Field Experiments was recently released to the public providing . A copy of the report is attached.
    • Report Abstract:
    • Service expectations placed on the fire service, including Emergency Medical Services (EMS), response to natural disasters, hazardous materials incidents, and acts of terrorism, have steadily increased. However, local decision-makers are challenged to balance these community service expectations with finite resources without a solid technical foundation for evaluating the impact of staffing and deployment decisions on the safety of the public and firefighters. For the first time, this study investigates the effect of varying crew size, first apparatus arrival time, and response time on firefighter safety, overall task completion, and interior residential tenability using realistic residential fires.
    • This study is also unique because of the array of stakeholders and the caliber of technical experts involved. Additionally, the structure used in the field experiments included customized instrumentation; all related industry standards were followed; and robust research methods were used. The results and conclusions will directly inform the NPFA 1710 Technical Committee, who is responsible for developing consensus industry deployment standards.
    • This report presents the results of more than 60 laboratory and residential fireground experiments designed to quantify the effects of various fire department deployment configurations on the most common type of fire—a low hazard residential structure fire. For the fireground experiments, a 2,000 sq ft (186 m2), two-story residential structure was designed and built at the Montgomery County Public Safety Training Academy in Rockville, MD. Fire crews from Montgomery County, MD and Fairfax County.
    • Report results quantify the effectiveness of crew size, first-due engine arrival time, and apparatus arrival stagger on the duration and time to completion of the key 22 fireground tasks and the effect on occupant and firefighter safety.
    • The report is also available for download at the NIST, HERE
    • Synopsis HERE

    USFA/NIST Trends in Firefighter Fatalities Due to Structural Collapse, 1979-2002

    • Between the years 1979 and 2002 there were over 180 firefighter fatalities due to structural collapse, not including those firefighters lost in 2001 in the collapse of the World Trade Center Towers. Structural collapse is an insidious problem within the fire fighting community. It often occurs without warning and can easily cause multiple fatalities.
    • As part of a larger research program to help reduce firefighter injuries and fatalities the U.S. Fire Administration (USFA) funded the National Institute of Standards and Technology (NIST) to examine records and determine if there were any trends and/or patterns that could be detected in firefighter fatalities due to structural collapse. If so, these trends could be brought immediately to the attention of training officers and incident commanders and investigated further to determine probable causes.
    • Report: Trends in Firefighter Fatalities Due to Structural Collapse1979-2002

    UL Fire Academy CBT

    • UL Structural Stability of Engineered Lumber in Fire Conditions
    • Base on the UL research and
    • This two-hour presentation summarizes a research study on the hazards posed to firefighters by the use of lightweight construction and engineered lumber in floor and roof designs. This free on-line computer based presentation will allow fire professionals to better interpret fire hazards and assess risk for life safety of building occupants and firefighters.
    • This online firefighter training course is the result of a research partnership among UL, the Chicago Fire Department, IAFC, and Michigan State University, funded in part by the U.S. Department of Homeland Security. This self-guided course, which focuses on the structural stability of engineered lumber under fire conditions, is targeted toward the 1.1 million fire service personnel in the United States and Canada. The knowledge developed and shared in this course is critically important to firefighter and civilian safety.
    • This two-hour presentation summarizes a research study on the hazards posed to firefighters by the use of lightweight construction and engineered lumber in floor and roof designs. This free on-line computer based presentation will allow fire professionals to better interpret fire hazards and assess risk for life safety of building occupants and firefighters.
    • Program Objectives:
    • Provide brief history of events leading up to DHS Grant tests
    • Identify the fire test hypothesis, parameters, and steps completed in the testing process
    • Compare tests results (legacy vs. modern construction)
    • Communicate learnings from our partners representing the fire service
    • Discuss code recommendations
    • UL University on-line Program HERE

    Fire Behavior 101; Taking it to the Streets

      

      

    Impact of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction

    For many of you that have been following my writings and perspectives on building construction, firefighting, command risk management and operational excellence for firefighter safety have long recognized that I have been promoting and advocating the fact the fireground is changing, our strategies and tactics demand change and does the demand for increased knowledge within the areas of building construction, fire dynamics, while integrating the art and science of firefighting. The most recent release of the testing report from Underwriters Laboratories; Impact of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction and the accompanying empirical data further validates assumptions and premises that many of us shared based upon field observations and first hand incident operations related to the dramatic changes being witnessed as a result of operational challenges in a wide variety of occupancies and building types.

    This material is a must read for all emerging and practicing company and command officers ( for starters) to being grasping the magnitude and extent of quantifiable data that supports the premise that combat fire engagement and suppression operations and the rules of engagement are going to change and that change is fast approaching.

    Here’s the executive summary of the report and findings from UL. For an download of the entire UL Report, go HERE.

    The results of these experiments provide knowledge for the fire service for them to examine their thought processes, standard operating procedures and training content. Several tactical considerations were developed utilizing the data from the experiments to provide specific examples of changes that can be adopted based on a departments current strategies and tactics.

    Under the United States Department of Homeland Security (DHS) Assistance to Firefighter Grant Program, Underwriters Laboratories examined fire service ventilation practices as well as the impact of changes in modern house geometries.

    There has been a steady change in the residential fire environment over the past several decades. These changes include larger homes, more open floor plans and volumes and increased synthetic fuel loads. This series of experiments examine this change in fire behavior and the impact on firefighter ventilation tactics.

    This fire research project developed the empirical data that is needed to quantify the fire behavior associated with these scenarios and result in immediately developing the necessary firefighting ventilation practices to reduce firefighter death and injury.

    • Two houses were constructed in the large fire facility of Underwriters Laboratories in Northbrook, IL.
    • The first of two houses constructed was a one-story, 1200 ft2, 3 bedroom, 1 bathroom house with 8 total rooms.
    • The second house was a two-story 3200 ft2, 4 bedroom, and 2.5 bathroom house with 12 total rooms.
    • The second house featured a modern open floor plan, two story great room and open foyer.

     Fifteen experiments were conducted varying the ventilation locations and the number of ventilation openings. Ventilation scenarios included ventilating the front door only, opening the front door and a window near and remote from the seat of the fire, opening a window only and ventilating a higher opening in the two-story house.

    One scenario in each house was conducted in triplicate to examine repeatability. The results of these experiments provide knowledge for the fire service for them to examine their thought processes, standard operating procedures and training content. Several tactical considerations were developed utilizing the data from the experiments to provide specific examples of changes that can be adopted based on a departments current strategies and tactics.

    Room Flashover from Sofa Fire

     

    The tactical considerations addressed include:

    • Stages of fire development: The stages of fire development change when a fire becomes ventilation limited.
      • It is common with today’s fire environment to have a decay period prior to flashover which emphasizes the importance of ventilation
    • Forcing the front door is ventilation: Forcing entry has to be thought of as ventilation as well.
      •  
      • While forcing entry is necessary to fight the fire it must also trigger the thought that air is being fed to the fire and the clock is ticking before either the fire gets extinguished or it grows until an untenable condition exists jeopardizing the safety of everyone in the structure.
    • No smoke showing: A common event during the experiments was that once the fire became ventilation limited the smoke being forced out of the gaps of the houses greatly diminished or stopped all together.
      • No some showing during size-up should increase awareness of the potential conditions inside.
    • Coordination: If you add air to the fire and don’t apply water in the appropriate time frame the fire gets larger and safety decreases.
      • Examining the times to untenability gives the best case scenario of how coordinated the attack needs to be.
      • Taking the average time for every experiment from the time of ventilation to the time of the onset of firefighter untenability conditions yields 100 seconds for the one-story house and 200 seconds for the two-story house
      • In many of the experiments from the onset of firefighter untenability until flashover was less than 10 seconds.
      • These times should be treated as being very conservative. If a vent location already exists because the homeowner left a window or door open then the fire is going to respond faster to additional ventilation opening because the temperatures in the house are going to be higher.
      • Coordination of fire attack crew is essential for a positive outcome in today’s fire environment.
    • Smoke tunneling and rapid air movement through the front door: Once the front door is opened attention should be given to the flow through the front door.
      • A rapid in rush of air or a tunneling effect could indicate a ventilation limited fire.
    • Vent Enter Search (VES): During a VES operation, primary importance should be given to closing the door to the room.
      • This eliminates the impact of the open vent and increases tenability for potential occupants and firefighters while the smoke ventilates from the now isolated room.
    • Flow paths: Every new ventilation opening provides a new flow path to the fire and vice versa.
      • This could create very dangerous conditions when there is a ventilation limited fire.
    • Can you vent enough?: In the experiments where multiple ventilation locations were made it was not possible to create fuel limited fires.
      • The fire responded to all the additional air provided.
      • That means that even with a ventilation location open the fire is still ventilation limited and will respond just as fast or faster to any additional air.
      • It is more likely that the fire will respond faster because the already open ventilation location is allowing the fire to maintain a higher temperature than if everything was closed. In these cases rapid fire progression if highly probable and coordination of fire attack with ventilation is paramount.
    • Impact of shut door on occupant tenability and firefighter tenability: Conditions in every experiment for the closed bedroom remained tenable for temperature and oxygen concentration thresholds.
      • This means that the act of closing a door between the occupant and the fire or a firefighter and the fire can increase the chance of survivability.
      • During firefighter operations if a firefighter is searching ahead of a hoseline or becomes separated from his crew and conditions deteriorate then a good choice of actions would be to get in a room with a closed door until the fire is knocked down or escape out of the room’s window with more time provided by the closed door
    • Potential impact of open vent already on flashover time: All of these experiments were designed to examine the first ventilation actions by an arriving crew when there are no ventilation openings.
      • It is possible that the fire will fail a window prior to fire department arrival or that a door or window was left open by the occupant while exiting.
      • It is important to understand that an already open ventilation location is providing air to the fire, allowing it to sustain or grow.
    • Pushing fire: There were no temperature spikes in any of the rooms, especially the rooms adjacent to the fire room when water was applied from the outside. It appears that in most cases the fire was slowed down by the water application and that external water application had no negative impacts to occupant survivability.
      • While the fog stream “pushed” steam along the flow path there was no fire “pushed”.
    • No damage to surrounding rooms: Just as the fire triangle depicts, fire needs oxygen to burn.
      • A condition that existed in every experiment was that the fire (living room or family room) grew until oxygen was reduced below levels to sustain it.
      • This means that it decreased the oxygen in the entire house by lowering the oxygen in surrounding rooms and the more remote bedrooms until combustion was not possible.
      • In most cases surrounding rooms such as the dining room and kitchen had no fire in them even when the fire room was fully involved in flames and was ventilating out of the structure.

    Online Training Program

    In order to make the results of this study more user friendly for the fire service to examine, UL developed an online interactive training module that can be viewed by clicking here. The program includes a professionally narrated description of all of the experiments, their results and the tactical considerations. Experimental video is used and graphical data is explained in a way that brings science to the street level firefighter.

    UL University On-Line CBT

     

     

    Fire/EMS Safety, Health and Survival Week: Day Three-The New Rules of Engagement

    6 comments

    Fire/EMS Safety, Health and Survival Week: Day Three-The New Rules of Engagement

     With so many changes (budget cuts, staffing reductions, reduced training, etc.) in so many fire departments, it is critical for fire fighters to focus on their own survival on the fire ground. There is no other call more challenging to fire ground operations than a Mayday call the unthinkable moment when a fire fighter’s personal safety is in imminent danger. Fire fighter fatality data compiled by the United States Fire Administration have shown that fire fighters becoming trapped and disoriented represent the largest portion of structural fire ground fatalities. The incidents in which fire fighters have lost their lives, or lived to tell about it, have a consistent theme inadequate situational awareness put them at risk.

    New Rules of Engagement

     Fire fighters don’t plan to be lost, disoriented, injured or trapped during a structure fire or emergency incident. But fires are unpredictable and volatile, and they will not always go according to plan. What a fire fighter knows about a fire before entering a blazing building may radically change within minutes once inside the structure. Smoke, low visibility, lack of oxygen, structural instability and an unpredictable fire ground can cause even the most seasoned fire fighter to be overwhelmed in an instant.

    It's Not a Matter of IF, It's a Matter of When

    It’s not a matter of IF the MAYDAY happens, it’s WHEN! Thius the reason for the 2011 Fire/EMS Safety, Health and Survival Week focus on Surviving the Fire Ground Fire Fighter, Fire Officer & Command Preparedness

    Theme: Surviving the Fire Ground Fire Fighter, Fire Officer & Command Preparedness

    • IAFC Safety Week Resources: Firefighter Survival, HERE
    • National Fire Fighter Near Miss Reporting System Resources, HERE

    With that being said, there must be a means and a method to better defined and more accurately

    • Without understanding the building-occupancy relationships and integrating; construction, occupancies, fire dynamics and fire behavior, risk, analysis, the art and science of firefighting, safety conscious work environment concepts and effective and well-informed incident command management, company level supervision and task level competencies…You are derelict and negligent and “not “everyone may be going home”.
    • Our current generation of buildings, construction and occupancies are not as predictable as past conventional construction; risk assessment, strategies and tactics must change to address these new rules of structural fire engagement.
    • There is a need to gain the building construction knowledge and insights and to change and adjust operating profiles in order to safe guard companies, personnel and team compositions. It’s all about understanding the building-occupancy relationships and the art and science of firefighting, Building Knowledge = Firefighter Safety (Bk=F2S)
    • Refer to: Fire/EMS Safety, Health and Survival Week: Day Two- Building Knowledge = Fire Fighter Safety 
    • When we look at various buildings and occupancies, past operational experiences; those that were successful, and those that were not, give us experiences that define and determine how we access, react and expect similar structures and occupancies to perform at a given alarm in the future.
    • Naturalistic (or recognition-primed) decision-making forms much of this basis. We predicate certain expectations that fire will travel in a defined (predictable) manner that fire will hold within a room and compartment for a predictable given duration of time; that the fire load and related fire flows required will be appropriate for an expected size and severity of fire encountered within a given building, occupancy, structural system; in addition to having an appropriately trained and skilled staff to perform the requisite evolutions.
    • Executing tactical plans based upon faulted or inaccurate strategic insights and indicators has proven to be a common apparent cause in numerous case studies, after action reports and LODD reports.
    • Our years of predictable fireground experience have ultimately embedded and clouded our ability to predict, assess, plan and implement incident action plans and ultimately deploy our companies-based upon the predictable performance expected of modern construction and especially those with engineered structural systems.
    • If you don’t fully understand how a building truly performs or reacts under fire conditions and the variables that can influence its stability and degradation, movement of fire and products of combustion and the resource requirements for fire suppression in terms of staffing, apparatus and required fire flows, then you will be functioning and operating in a reactionary manner, that is no longer acceptable within many of our modern building types, occupancies and structures.
    • This places higher risk to your personnel and lessens the likelihood for effective, efficient and safe operations.
    • You’re just not doing your job effectively and you’re at RISK. These risks can equate into insurmountable operational challenges and could lead to adverse incident outcomes. Someone could get hurt, someone could die, it’s that simple; it’s that obvious

     

    Original IAFC 2001 ROE

     

    • Combat Fire Suppression and Engagement has been dramatically influenced by numerous challenges in terms of effectiveness, methodologies, risk and operational capabilities….yet we implement strategic and tactical models and protocol predicated on past performance of building structures and occupancies and fire fighting successes….
    •  It’s no longer just brute force and sheer physical determination that define structural fire suppression operations
    • We used to discern with a measured degree of predictability, how buildings would perform, react and fail under most fire conditions. Implementing fundamentals of firefighting and engine company operations built upon eight decades of time tested and experience proven strategies and tactics continues to be the model of suppression operations.
    • These same fundamental strategies continue to drive methodologies and curriculums in our current training programs and academies of instructions.
    • 2009 was a significant and decisive year for the fire service in a number of ways….
    • Controversy, debate, argument; enlightenment, knowledge, insights, awareness, comprehension, understanding….
    • Which leads me to call this the emerging tactical renaissance….

     

    The International Association of Fire Chiefs (IAFC) is committed to reducing firefighter fatalities and injuries. As part of that effort the nearly 1,000 member Safety, Health and Survival Section of the IAFC has developed the NEW  “Rules of Engagement of Structural Firefighting” to provide guidance to individual firefighters, and incident commanders, regarding risk and safety issues when operating on the fireground.

    The intent was to provide a set of “model procedures” for Rules of Engagement for Structural Firefighting to be made available by the IAFC to fire departments as a guide for their own standard operating procedure development.

    In August, 2008, following a year of discussion, the Section moved to develop a set of “Rules of Engagement for Structure Firefighting”.

    A project team was created consisting of Section members and representatives of other several other interested fire service organizations.

    These included the;

    • Fire Department Safety Officer Association (FDSOA),
    • the National Fallen Firefighter Foundation (NFFF),
    • the National Volunteer Fire Council (NVFC), the
    • National Institute of Occupational Safety and Health (NIOSH) and other organizations.
    • All draft material has also been shared with representatives of the International Association of Fire Fighters (IAFF) who developed a joint IAFF/IAFC Fire Ground Survival Project”.

     Three Section members also participated in the IAFF project.

    The direction provided the project team by the Section leadership was to develop rules of engagement with the following conceptual points;

    • Rules should be a short, specific set of bullets
    • Rules should be easily taught and remembered
    • Rules should define critical risk issues
    • Rules should define “go” or “nogo” situations
    • A companion lesson plan/explanation section should be provided

    Early in development the Rules of Engagement, it was recognized that two separate rules were needed –one set for the firefighter, and another set for the incident commander.

    Thus, the two sets of Rules of Engagement were conceived and developed.

    Each set has several commonly shared bullets and objectives, but the explanations are described somewhat differently based on the level of responsibility (firefighter vs. incident commander).

    The 2010 Rules of Engagement reflects nearly two years of public comment and feedback from several presentations at fire service conferences, including the National Fallen Fire Fighters Safety Summit held at the National Fire Academy this past March 2010.

    The “Rules” was formally adopted by the IAFC Health, Safety and Survival Section at the Fire Rescue International Conference that was held in Chicago this past August 2010

    The project team was lead by Chief Gary Morris,

    Document Description

    Section One

    • includes introduction statements and background regarding the Rules of Engagement project.

    Section Two

    • acknowledges the Project team members and others that assisted in the project.

     Section Three

    • contains the individual “Bullets” for both the Rules of Engagement for Firefighter Survival as well as the Incident Commanders Rules of Engagement for Firefighter Safety.

     Section Four

    • describes the objectives attached to each of the individual “bullets” for both set of Rules.

     Section Five

    • provides an introduction and overview of the lesson plans for the Rules of Engagement.

     Section Six

    • includes the lesson plan for the Rules of Engagement of Firefighter Survival.

     Section Seven

    • contains the lesson plans for the Incident Commanders Rules of Engagement for Firefighter Safety.

     Section Eight

    • serves as appendixes and contains full investigation reports of several significant firefighter fatality incidents.

     The Need for Rules of Engagement

    • Firefighter safety must always be a priority for every fire chief and every member. Over the past three decades, the fire service has applied new technology, better protective clothing and equipment, implemented modern standard operating procedures, and improved training.
    • According to National Fire Protection Association (NFPA) data during this same period the fire service has experienced a 58 percent reduction in firefighter line of duty deaths. But, the country has also seen a paralleling 54 percent drop in the number of structural fires over the same period – thus, reducing firefighter exposure to risk.
    • With a continued annual average of more than 100 firefighter fatalities, the question remains; have we really made a difference with all these technology improvements? Or, is there more that we can do to improve the safety culture of the American fire service?
    • The U.S. Firefighter Disorientation Study, conducted by Captain Willie Mora, San Antonio, Texas, Fire Department, conducted a review of 444 firefighter fireground deaths occurring over a recent 16 year period (1990-2006).
      • The project broke out traumatic firefighter fatalities occurring in “open structures” and “enclosed structures”. Open structures was defined as smaller structures with an adequate number of windows and doors (within a short distance) to allow for prompt ventilation and emergency evacuation.
      • Enclosed structures were defined as large buildings with inadequate windows or doors to allow prompt ventilation and emergency evacuation. Research determined that 23 percent occurred when a fast and aggressive interior attack was made on an “opened structure”. When fast, aggressive interior attacks occurred in “enclosed structures” the fatality rate rose to 77 percent. Many occurred in “marginal” or rapidly changing conditions in which the firefighter should not have been in the building.
    • The fireground creates a significant risk to firefighters and it is the responsibility of the incident commander and command organization officers to minimize firefighter exposure to unsafe conditions and stop unsafe practices.
    • The fire service has always been a para-military organization when it comes to fireground operations. In most cases, the Incident Commander makes a decision, sends the order down to through supervisors to the company officer and crew.
    • Fire crews generally view these orders as top down direction. There is often little two‐way discussion about options.
    • Where this culture exists, crews have been trained to accept the order and do it – generally without question.
    • While these orders may be viewed as valid when issued they may involve inadequate risk assessment.
    • There has been little national development of basic “rules” that the incident command should use in defining risk assessment process and what is too high risk that may result in a “no-go” decision.
    • Furthermore, for the individual firefighter who is exposed to the greatest risk, we have not defined “rules” for them to follow in assessing their individual risk and when and how to say “no” to unsafe conditions or practices. The “Rules of Engagement” changes that.
    • The “Rules of Engagement” have been developed to assist both the incident command (as well as command team officers) in risk assessment and “Go” – “No-Go” decisions. Applying the rules will make the fireground safer for all and reduce injuries and fatalities.

     

    The development of the rules integrated several nationally recognized programs and principles. They included risk assessment principles from NFPA Standards 1500 and 1561.

    Also included where concepts and principles from Crew Resource Management (available from iafc.org) and data and lessons from the National Near-Miss Reporting System (firefighternearmiss.com).

    The development process also included review of lessons learned from numerous firefighter fatality investigations conducted by the National Institute of Occupational Safety and Health (NIOSH) Fire Fighter Fatality Investigation and Prevention Program.

    It’s incumbent that the fire chief and the Departments management team insure the safety of all firefighters working at structural fires.

    • All command organization officers are responsible for their own safety and the safety of all personnel working with them.
    • All officers and members are responsible are responsible for continually identifying and reporting unsafe conditions or practices.
    • The Rules of Engagement allows both the firefighter and the incident commander to apply and process these principles.
    • One principle applied in the Rules of Engagement is firefighters and the company officers are the members at most risk for injury or death.
    • The Rules integrate the firefighter into the risk assessment decision making process.
    • These members should be the ultimate decision maker as to whether it’s safe to proceed with assigned objectives.
    • The “Rules” allow a process for that decision to be made while still maintain command unity and discipline.

     

    Operational Excellence and the ROE

     

    The NEW Rules of Engagement

    It is well known that firefighting is hazardous with varying levels of risk to the firefighter.

    However, firefighting is not a military campaign where lives are lost to establish a beach head.

    No firefighter’s life is a building that eventually will be rebuilt. Keep all members safe so “Everyone Goes Home”!

    Rules of Engagement for Firefighter Survival

    • Size-Up Your Tactical Area of Operation.
    • Determine the Occupant Survival Profile.
    • DO NOT Risk Your Life for Lives or Property That Can Not Be Saved.
    • Extend LIMITED Risk to Protect SAVABLE Property.
    • Extend Vigilant and Measured Risk to Protect and Rescue SAVABLE Lives.
    • Go in Together, Stay Together, Come Out Together
    • Maintain Continuous Awareness of Your Air Supply, Situation, Location and Fire Conditions.
    • Constantly Monitor Fireground Communications for Critical Radio Reports.
    • You Are Required to Report Unsafe Practices or Conditions That Can Harm You. Stop, Evaluate and Decide.
    • You Are Required to Abandon Your Position and Retreat Before Deteriorating Conditions Can Harm You.
    • Declare a May Day As Soon As You THINK You Are in Danger. 

    The Incident Commanders Rules of Engagement for Firefighter Safety

    • Rapidly Conduct, or Obtain, a 360 Degree Size‐Up of the Incident.
    • Determine the Occupant Survival Profile.
    • Conduct an Initial Risk Assessment and Implement a SAFE ACTION PLAN.
    • If You Do Not Have The Resources to Safely Support and Protect Firefighters – Seriously Consider a Defensive Strategy.
    • DO NOT Risk Firefighter Lives for Lives or Property That Can Not Be Saved – Seriously Consider a Defensive Strategy.
    • Extend LIMITED Risk to Protect SAVABLE Property.
    • Extend Vigilant and Measured Risk to Protect and Rescue SAVABLE Lives.
    • Act Upon Reported Unsafe Practices and Conditions That Can Harm Firefighters. Stop, Evaluate and Decide.
    • Maintain Frequent Two‐Way Communications and Keep Interior Crews Informed of Changing Conditions.
    • Obtain Frequent Progress Reports and Revise the Action Plan.
    • Ensure Accurate Accountability of All Firefighter Location and Status.
    • If, After Completing the Primary Search, Little or No Progress Towards Fire Control Has Been Achieved -Seriously Consider a Defensive Strategy.
    • Always Have a Rapid Intervention Team in Place at All Working Fires
    • Always Have Firefighter Rehab Services in Place at All Working Fires

      

     
     
     

    ROE Fire Fighter

     

      

      

    ROE Command

     

    Other ROE Insights

    Size-Up Your Tactical Area of Operation.

    Objective:    To cause the company officer and firefighters to pause for a moment and look over their area of operation and evaluate their individual risk exposure and determine a safe approach to completing their assigned tactical objectives.

    Rapidly Conduct, or Obtain, a 360 Degree Situational Size Up of the Incident

    Objective:    To cause the incident commander to obtain an early 360 degree survey and risk assessment of the fireground in order to determine the safest approach to tactical operations as part the risk assessment and action plan development and before firefighters are placed at substantial risk.

    ______________________________________________________________________________

    Determine the Occupant Survival Profile.

    Objective: To cause the company officer and firefighter to consider fire conditions in relation to possible occupant survival of a rescue event as part of their initial and ongoing individual risk assessment and action plan development.

      

    Determine the Occupant Survival Profile.

    Objective: To cause the incident commander to consider fire conditions in relation to possible occupant survival of a rescue event before committing firefighters to high risk search and rescue operations as part of the initial and ongoing risk assessment and action plan development.

      

    Go in Together, Stay Together, Come Out Together

    Objective: To ensure that firefighters always enter a burning building as a team of two or more members and no firefighter is allowed to be alone at any time while entering, operating in or exiting a building. 

      

    Maintain Continuous Awareness of Your Air Supply, Situation, Location and Fire Conditions

    Objective: To cause all firefighters and company officers to maintain constant situational awareness their SCBA air supply and where they are in the building and all that is happening in their area of operations and elsewhere on the fireground that may affect their risk and safety.

    ______________________________________________________________________________

    You Are Required to Report Unsafe Practices or Conditions That Can Harm You. Stop, Evaluate, and Decide.

    Objective: To prevent company officers and firefighters from engaging in unsafe practices or exposure to unsafe conditions that can harm them and allowing any member to raise an alert about a safety concern without penalty and mandating the supervisor address the question to ensure safe operations.

      

    Act Upon Reported Unsafe Practices and Conditions That Can Harm Them. Stop, Evaluate and Decide.

    Objective: To prevent firefighters and supervisors from engaging in unsafe practices or exposure to unsafe conditions that will harm them and allowing any member to raise an alert about a safety concern without penalty and mandating the incident commander and command organization officers promptly address the question to insure safe operations. 

    ______________________________________________________________________________  

    Declare a May-Day As Soon As You THINK You Are in Danger

    Objective: To ensure the firefighter is comfortable with, and there is no delay in, declaring a May Day when a firefighter is faced with a life threatening situation and the May Day is declared as soon as they THINK they are in trouble.

      

    Always Have a Rapid Intervention Team in Place at All Working Fires.

    Objective: To cause the incident commander to have a rapid intervention team in place ready to rescue firefighters at all working fires.

    ______________________________________________________________________________

    Ensure Accurate Accountability of Every Firefighter Location and Status

    Objective: To cause the incident commander, and command organization officers, to maintain a constant and accurate accountability of the location and status of all firefighters within a small geographic area of accuracy within the hazard zone and aware of who is presently in or out of the building.

    If You Do Not Have the Resources to Safely Support and Protect Firefighters, Seriously Consider a Defensive Strategy

    Objective: To prevent the commitment of firefighters to high risk tactical objectives that cannot be accomplished safely due to inadequate resources on the scene.

    SOPs/SOGs

    Rules of Engagement for Structural Firefighting (pdf)

    Risk Management

    General Order: Two-In, Two-Out Compliance, Rapid Intervention Team, and Firefighter Survival

    Emergency Evacuation
    This policy identifies a standard system for the emergency evacuation of personnel at an emergency incident or training exercise.

    Fire and Rescue Departments of Northern Virginia – Rapid Intervention Team Command and Operational Procedures
    A collaborative RIT manual developed by fire and rescue departments in Northern Virginia. Promotes interoperability between multiple fire agencies.

    Lost or Trapped Firefighters
    This policy identifies the required actions for the search and rescue of lost or trapped firefighter(s).

    Model Procedures for Responding to a Package with Suspicion of a Biological Threat
    Local and world events have placed the nation s emergency service at the forefront of homeland defense. The service must be aware that terrorists, both foreign and domestic, are continually testing the homeland defense system.

    Safety Initial Rapid Intervention Crew (IRIC)
    This policy establishes procedures for ensuring the highest level of safety when conducting interior operations in an atmosphere that is Immediately Dangerous to Life and Health (IDLH).

    Safety Rapid Intervention Team (RIT)
    This policy establishes the department s criteria and procedures for Rapid Intervention Teams.

      

    Operational Excellence in 2011 and Beyond

      

    Taking It To The Streets: My Closing Commentary and The Rules of Combat Fire Suppression  

    The essence of fire service suppression operations is predicated upon the deployment and application of water as an extinguishing agent, in sufficient quantities, location and duration to extinguish a fire within an enclosed structural compartment. The universal engine company correlation of: “putting the wet stuff on the red stuff” is fundamental to structural fire suppression operations but is ambiguous at best in the context of today’s modern building construction, occupancies, structural systems and building features. 

    We used to discern with a measured degree of predictability, how buildings would perform, react and fail under most fire conditions. Implementing fundamentals of firefighting and engine company operations built upon eight decades of time tested and experience proven strategies and tactics continues to be the model of suppression operations. These same fundamental strategies continue to drive methodologies and curriculums in our current training programs and academies of instructions.

    The lack of appreciation and the understanding of correlating principles involving fire behavior, fuel and rate of heat release and the growth stages of compartment fires within a structural occupancy are the defining paths from which the fire service must reexamine engine company operations in order to identify with the predictability of occupancy performance during fire suppression operations thus increasing suppression effectiveness and firefighter safety.

    Our buildings have changed; the structural systems of support, the degree of compartmentation, the characteristics of materials and the magnitude of fire loading. The structural anatomy, predictability of building performance under fire conditions, structural integrity and the extreme fire behavior; accelerated growth rate and intensively levels typically encountered in buildings of modern construction during initial and sustained fire suppression have given new meaning to the term combat fire engagement.

    The rules for combat structural fire suppression have changed, but we have yet to write the rule book from which the new games plans must be derived…..

    However, we now have a new set of Rules for Engagement….

    • The Incident Commanders Rules of Engagement for Firefighter Safety
    • Rules of Engagement for Firefighter Survival
    • Tactical Renaissance ……….Tactical Patience

    …….integrate cutting edge research and emerging concepts on Tactical Patience, Tactical Entertainment, Command Compression, Structural Anatomy of Buildings, Five Star Command Model, Predicative Strategic Process, refined Tactical Deployment Models integrating intelligent Structural Anatomy and Predictive Occupancy Profiling and Integrating the RULES OF ENGAGEMENT for Structural Firefighting much more.  

    It’s really all about Fighting Fire with More Knowledge and smartly

      

     

    Taking it to the Streets with Christopher Naum

       

    Taking it to the StreetsTM, radio program hosted by highly regarded national instructor, author, lecturer and fire officer Christopher Naum, continues to provide provocative insights and dynamic discussions with leading national fire service leaders and guests on important issues affecting the American Fire Service with applications internationally within the tradition and brotherhood of the Fire Service.

     

    Taking it to the Streets “Tactical Renaissance and the Rules of Engagement”

    Podcast: Play in new window | Download

    Share

    This is the netcast which was offered live on September 22, 2010. Taking it to the Streets “Tactical Renaissance and the Rules of Engagement” Chief Gary Morris (ret) Phoenix (AZ) Fire Department, and Dr. Burt Clark from the NFA join Chris Naum as they discuss the emerging Tactical Renaissance of Combat Fire Suppression Operations [...]

    Taking it to the StreetsTM is a monthly radio show featured on BlogTalk Radio and is hosted by nationally renowned fire service leader Christopher Naum, a  36-year fire service veteran and highly regarded national instructor, author, lecturer and fire officer and  the distinguished leading  national authority on building construction and fire ground operations.  Taking it to the StreetsTM is a Buildingsonfire.com Series and FireFighternetcast.com Production,   © 2011 All Rights Reserved 

    Check out the latest downloads of recent programs in the archives by visiting Taking it to the Street’s webpage on Firefighternetcast.com or for program insights at CommandSafety.com.    

    • Firefighternetcast.com HERE
    • Taking it to the Streets Radio Programs, HERE and HERE 
    • Buildingsonfire.com, HERE

      

    A Buildingsonfire.com Series and Firefighter Netcast.com Production

    Taking it to the StreetsTM  with Christopher Naum
     
     

    Listen to all of the Taking It To The Streets shows here

     On the Air Monthly on Firefighter Netcast.com

    Advancing Firefighter Safety and Operational Integrity for the Fire Service through provocative insights and dynamic discussions dedicated to the Art and Science of Firefighting and the Traditions of the Fire Service.

     

    Situational Awareness: Wall Collapse Near Miss

    No comments

    UK Firefighter Narrowly Escapes Wall Collapse
    Collapse captured on dash cam shows Greater Manchester (UK) Fire and Rescue Service close call

    This was recently posted on Firefighternation.com and depicts a a video clip that captures a dramatic near miss of a colleague who could have been killed when a house collapsed today released footage of the incident. Greater Manchester Fire and Rescue Service said the incident in Littleborough, Rochdale, in September 2010 was being released as part of health and safety training for its staff and other fire and rescue services in the UK.

    The dramatic footage, caught by a CCTV camera on a fire engine attending the scene, shows a fire fighter narrowly escaping death or serious injury as the front of a derelict terrace house collapsed, almost on top of him. The firefighter seems hardly fazed by the close call.

    County Fire Officer and Chief Executive Steve McGuirk said the footage provided terrifying viewing for the service, who would use it as a training example to ensure crew were more aware of the dangers.

    He added: “The footage is unbelievable. Our crew and the police are diligently attending this incident, where a derelict property is on fire. But who could have predicted the front of the house would collapse in this way. It is frighteningly close and this fire fighter could so easily have been killed. It’s a powerful example of how our fire fighters put themselves at risk each and every day to keep people across Greater Manchester safe.”

    The footage will now form part of the service’s operational assurance processes and used to make fire fighters aware of the potential risks of similar incidents.

    Greater Manchester Fire and Rescue Service has 41 stations across the 10 boroughs of the county and attended approximately 50,000 incidents involving fire and collisions on roads and motorways, and other emergencies, last year.

    • Greater Manchester Fire and Rescue Services  Link HERE

    Stairway Collapse and Mayday in Chicagoland

    No comments

                                                     

    A fire in single family residential occupancy in Chicago’s West Humboldt Park section on May 29th produced these dramatic occurrences: Serious injury to a woman and her grandchild, a firefighter being trapped, and good Samaritans lending a hand.

    About 12:30 a.m., Chicago fire officials and police responded to a fire in a one-and-a-half story single family home in the 4200 block of West Hadden Avenue on the West Side, according to police and fire officials. A 2-11 Alarm and EMS Plan 1 were called for the fire, said Fire Media Affairs spokesman Chief Joe Roccasalva. The fire was located in a 1 1/2 story wood frame bungalow (SFR) dwelling.  According to published reports, the firefighter fell through a burning stairwell when it collapsed and was briefly trapped. He was quickly located and extricated with minor injuries following the mayday alert

    4246 West Hadden Ave

    Aerial

     

    Chicago Sun-Times, HERE and Breaking News Report, HERE and ABC News7 TV, HERE

    Typical Circa Stairway Construction

     

    Don’t forget to check out the 2011 Safety and Survival Week focus on;

    2011 Focus: Surviving the Fire Ground – Fire Fighter, Fire Officer & Command Preparedness, HERE

     

    Another Near Miss Floor Collapse

    3 comments

    Floor compromise and isolated shift resulted in minor firefighter injuries and a near miss event in San Diego (CA)

    Albuquerque Fire Department; Learnings from Close Call Collapse and Fire Fighter Injuries

    No comments

    The Albuquerque Fire Department seeks to improve operations from past performance

    Four firefighters with the Albuquerque (NM) Fire Department were injured during operations at a three-alarm fire that injured raged through the Royal Crown Apartment Complex  in southeast Albuquerque on Friday February 4, 2011.

    The injured firefighters were among four who fell through the floor from the second story to the first while searching for residents of the, according to the Albuquerque Fire Department. Both suffered leg injuries, one had minor burn, and they were treated and released from University of New Mexico Hospital a few hours later, an AFD spokesperson said.

    According to published reports at the time of the event, the first alarm came in at 3 p.m. bringing personnel and apparatus to the three-story building at 4801 Gibson SE. First units on the scene reported heavy smoke and flames on the north side of the building.

    A crew from AFD Engine 13 entered the building and during a search rescued two uninjured residents from one apartment and also save a cat.

    At 3:40 p.m. Incident command transitioned to a defense operations to fight the fire from outside the building. The third alarm was transmitted due to the projected heavy fuel load in the large complex.

    Overall 75 fire personnel responded and operated at the alarm.

    The fire is believed to have started behind a washing machine in the first-floor laundry room. An electric cause is suspected, but AFD said the exact cause is still under investigation.

    The three-story multiple occupancy apartment complex was built in 1976 and housed 47 apartment units in 31,896 square feet of space.

    In the months since the fire, the Albuquerque Fire Department has conducted a critique and post incident assessment of the operations, mayday and close-calls and overall performance of the department. As reported in the media video leading into this article, the department has taken the results of that post incident assessment and has developed training being delivered to al personnel to increase future operational performance, efficiencies and to reduce the likely hood of a similar event from occurring.

    According to the Fire Department, they were playing catch-up from the early advancing stages of the incident and experienced difficulty in being able to make strategic strides to get ahead of the escalating incident severity, magnitude and rapid development.

    The unexpected events leading to the multiple maydays and firefighter injuries challenged incident command and operations and could have resulted in possible multiple firefighter LODDs versus the close-call, near-miss events that subsequently lead towards the efforts to undertake  critical review of the incident and operations.

    Some Insights and Learning’s from the Incident included that have resulted in enhancements;

    • Communications
    • Situational Awareness
    • Calling the Mayday
    • Radio Communications
    • Distractions and Error Prevention
    • Accountability
    • Command Response to Mayday Events
    • Communications Mayday Alerts

    It is imperative that all departments initiate at the least a formal or informal post incident critique or review. This may be at the company or station level or escalated to a more formal department level assessment and review based upon the incident parameters and conditions.

    The initiation and development of post incident analysis or assessment can be more involving and complex, with the commitment of personnel, resources and time but the benefits derived from such a review will contribute highly to the continued development and improvement of any organization. 

    There are a number of recent after action, post incident or assessments reports that have been published and have been reviewed and discussed here on CommandSafety.com.

    Take the time to review your incidents and runs at the company, station or battalion level. These reviews will identify and address low threshold, latent or emerging conditions before they escalate into apparent or root cause conditions that may contribute to significant adverse events and incidents.

    The Albuquerque (NM) Fire Department’s self-critical review of this event has identified short comings at a number of levels that they are working to improve.

    As they state in the video report, the outcome of this event could have been a lot worse than the injuries sustained and the resultant near-misses. The focus on improvements and enhancements within the functional areas of Calling the Mayday, Rapid Intervention and Mayday Communications and Operations is commendable and aligns with this year’s theme for Safety, Health and Survival Week.

    The 2011 Safety Week theme is; Surviving the Fire Ground – Fire Fighter, Fire Officer and Command Preparedness.

    • Previous Safety Week announcement and details; HERE.
    • We’ll post under a separate article details on the IAFF Fire Ground Survival Program soon.

    Albuquerque (NM) Fire Department’s Web Site, HERE

    This year’s Safety Week will focus on delivering the online IAFF Fire Ground Survival (FGS) awareness training course to all fire departments. The program is the most comprehensive survival skills and MAYDAY prevention program currently available and is open to all members of the fire service. Additional planning tools and resources will be available on the Safety Week website.

    The IAFF Fire Ground Survival Program (FGS) is the most comprehensive survival-skills and mayday-prevention program currently available and is open to all members of the fire service. Incorporating federal regulations, proven incident-management best practices and survival techniques from leaders in the field, and real case studies from experienced fire fighters, FGS aims to educate all fire fighters to be prepared if the unfortunate happens.

    For links to the IAFF Fire Ground Survival Program, HERE and HERE

    The program will provide participating fire departments with the skills they need to improve situational awareness and prevent a mayday. Topics covered include:

    • Preventing the Mayday: situational awareness, planning, size up, air management, fitness for survival, defensive operations.
    • Being Ready for the Mayday: personal safety equipment, communications, accountability systems.
    • Self-Survival Procedures: avoiding panic, mnemonic learning aid “GRAB LIVES”— actions a fire fighter must take to improve survivability, emergency breathing.
    • Self-Survival Skills: SCBA familiarization, emergency procedures, disentanglement, upper floor escape techniques.
    • Fire Fighter Expectations of Command: command-level mayday training, pre-mayday, mayday and rescue, post-rescue, expanding the incident-command system, communications.

    Keep watching the website and the IAFC’s Facebook, Twitter and LinkedIn pages for continuing updates to this year’s program and planning resources.

    Remember to visit the SHS Section’s website for more information on health and safety issues and the IAFF’s Health, Safety and Medicine’s website for more information on health, wellness and safety programs.

    Additionally, look for a comprehensive series of articles, activities, insights, downloads, podcasts, video clips and resources that will be posted each day of Safety, Health and Survival Week here on Commandsafety.com, Thecompanyofficer.com and Buildingsonfire.com.

    Announcements and campaign materials will begin posting in Mid-May.

    We will be offering a special series of live shows nightly on Taking it to the Streets on Firefighternetcast.com and blogtalkradio during the week of June 19-25, 2011 addressing key issues with a stellar line-up of fire service leaders.

    This will be an exceptional opportunity to listen in, call in and participate actively in the week’ theme of Surviving the Fire Ground – Fire Fighter, Fire Officer and Command Preparedness.

    These shows will be mission critical. Stay Tuned for more upcoming information.

    Be Self-Critical and a Learning Organization

    • In the meantime think about your operations; are you self-critical and a learning organization seeking to identify gaps or areas for improvement?
    • There is a lot that can be learned from our daily responses and operations, whether they be that single company response or that multiple alarm incident. 
    • All it takes is the recognition to see things for what they are and your may not be as good as you think and the understanding and desire to identify those conditions and improve .

     

    Addtional Resources, videos and images related to the Albuquerque (NM) Fire Department’s operations at the Royal Crown Apartment Complex

    Alpha Street Side View

     

    Aerial View from the Delta Side

     

    KASA News 13 photo by Alex Tomlin.

    Compromised Floor Assembly Traps Firefighters

    3 comments

    Residential Fire and Floor Compromise Norwichbulletin.com

    A Taftville (CT) Firefigher was caught in a compromised floor condition while fighting a fire in a residential occupancy on Friday morning April 15th in Norwich, CT., resulting in a mayday and RIT deloyment to support the extrication and firefighter removal from the interior.

    Published reports from Theday.com indicated a fire fighter issued a mayday after his foot plunged through the floor up to his knee, according to  according to Taftville (CT) Fire Chief Tim Jencks.

    Two other fire fighters held him up so he wouldn’t fall through any farther, while several others rushed over to help.

    A half dozen fire fighters worked to untangle wires that had dropped down from the sagging ceiling and to extricate the fire fighter from the damaged floor; the two who were holding him up also started to break through the floor, Jencks said.

    Mutual aid from the Yantic Fire Company as well as the rapid intervention team from the Mohegan Sun Tribal department responded. 

    • Fire ground Photos NorwichBulletin.com, HERE
    • Additional Links, HERE and HERE

    The single family residential occupancy was constructed in 1932 and was a four bedroom colonial design with 1,965 square feet of space. The floor assembly was conventional full dimensional wood floor joist construction.

    Two Story Four Bedroom Colonial, Circa 1932

    Alpha Side Post Fire

    Aerial View from Bing.com

     

    Here’s some diagrams and images for common floor joist assembly systems Circa 1932

     

     
     
     

     

    Common Balloon Frame Wall-Floor Construction

     

    Full Dimensional Floor Joists

    Circa 1930's Floor Joist Configurations

    Double Mayday Deployments at Three Alarm FDNY Fire

    1 comment

    2 Firefighters Escape Close Call in Belle Harbor: MyFoxNY.com

    Published reports from various NYC eMedia outlets indicated that two FDNY firefighters battling a three-alarm fire on Saturday April 9th in the Rockaways section of the Borough of Queens (NY) transmitted Maydays signals during fire suppression operations after a fire officer was partially trapped in a compromised  floor collapse and in another area of the occupancy a firefighter route was blocked due to fire extension resulting in the need to deploy this personal safety system (PSS)  to bail from a window. Reports indicated that FDNY Fire Lt. Richard Barnes fell through the second floor of the three-story Rockaways taxpayer building, but managed to hang on by his armpits until FAST firefighters could pull the 22-year veteran to safety, officials stated.

    FDNY Firefighter Evan Davis transmitted a mayday signal when he was trapped by flames in another part of the building’s second floor, resulting in the eight-year veteran deploying his personal escape rope to lower himself out a window, unaware there was an adjacent roof less than 10 feet below.

    • The first mayday was transmitted 27 minutes into the operations, the second mayday was transmitted 43 minutes elapsed time into the operations
    • 10:36 hours – Duration 27 minutes elapsed incident time:  First Mayday, Trapped firefighter due to partial  floor collapse
    • Sixteen minutes later;
    • 10:54 hours – Duration 43 minutes elapsed incident time: Second Mayday, Firefighter bailout of window

    A dozen of the 138 firefighters who responded to the fire suffered minor injuries.

    Fire Officials reported the fire started about 10:oo hours near an oil burner in the basement of the building.

    Read more: http://www.nypost.com/p/news/local/queens/close_call_for_qns_bravest_v120FHtVrYnSOlvMeile1L#ixzz1JAPLC1c6

    The building (Fire Building) consisting of a single story commerical occupancy on the Alpha (street side) that was attached to a three story wood frame multiple occupancy (MO) structure 30 x 100 (ft)

    From FirefighterSpot.com

     

    Aerial From Bing Maps

     

    Alpha Side Street View from GoogleStreets

     

    Surrounding Properties consisted of the following based upon radio transmissions;

    • Exposure #1: Is a street
    • Exposure #2: Is a 2 Story Similar attach (structure)
    • Exposure #3: Is a Rear Yard
    • Exposure #4: Is an Alleyway

    All – Hands transmitted:
    7 – 5 – 1407 @ 10:19
    Batt. 47 reports: Box 1407, All – Hands on arrival.
    Extra Engine & truck. We have a heavy fire condition in a 3 Story Commercial.
    Engine 309 & Lad. 134 are s/c

    2nd Alarm:
    2 – 2 – 1407 @ 10:21
    Engs. 264, 328, 323
    T. Lad. 153
    Eng. 284 w / Satellite 4
    Batt. 39 “Safety Officer”
    Batt. 43 “Resource Unit Leader”
    Rescue Battalion / Safety Battalion
    Fieldcom 1 / Tactical Support Unit #2

    Links and coverage;

    Here’s the incident particulars based upon radio transmssions and transcript : From the Nassau FD Rant (HERE) NassauFDrant.com

    • FDNY Belle Harbor, Queens, New York April 9th, 2011
      Address: 424 Beach 129 st between Cronston and Newport Aves10:10 hours
      Phone Box 1407 – Report of fire in a restaurant
      Engs. 268, 329, 266
      L137, TL121
      Battalion 4710-75-1407 – 10:13 hours
      E265
      TL159 (FAST Truck)
      Battalion 33
      Division 13
      Squad 270
      Rescue 4

    CIDS for 420 Beach 129 st:
    Restaurant 1 story 30×100 class 3. Partial sprinkler siamese on exposure 1 for cellar and kitchen areas

    7-5-1407 – 10:19 hours
    Battalion 47: We have a heavy fire condition, extra engine and truck. All-Hands on Arrival.
    E309, L134 S/C
    RAC2

    2-2-1407 – 10:19 hours
    Engs. 264, 328, 323
    E284 w/ Satellite 3
    TL153
    Battalion 39 (Safety Officer)
    Battalion 43 (Resource Unit Leader)
    Safety, Rescue Battalions
    Tactical Support 2
    FieldCom 1

    10:23 hours – Duration 14 minutes
    BC47: Box 1407, the address 424 Beach 129 st, we have fire on the 1st and 2nd floor extended to the 3rd floor, check the basement for extension. Exposure 1 is a street, 2 is a similar attached, 3 is a rear yard, 4 is an alley, k.

    10:27 hours
    TL157 S/C

    10:29 hours
    The staging area is Cronston Ave and Beach 131 st

    10:29 hours – Duration 22 minutes
    Division 13: 2nd Alarm Box 1407, we’ve got 4 lines stretched, 2 in operation, we have heavy fire on the 2nd floor of a 2 1/2 story commercial. You’ve got a 30×100, fire on the 2nd floor. 1st floor commercial occupancy, 2nd floor multiple dwelling, 3rd floor possibly apartments also.

    10:31 hours – Duration 23 minutes
    DC13: 2nd Alarm Box Box 1407, we have 4 lines stretched, 2 in operation. We’re going to change it from a 2 1/2 story to a 3 story building. Fire’s Doubtful, searches in progress, trucks are opening up, the 2nd Alarm is still Doubtful.

    10:36 hours – Duration 27 minutes
    DC13: 2nd Alarm Box 1407, a MAYDAY has been transmitted, the MAYDAY has been recovered and removed from the building. We put the FAST Truck to work, special call another FAST Truck. We’re Doubtful on the 2nd Alarm.
    L173 (FAST Truck) S/C

    10:38 hours – Duration 30 minutes
    E321 S/C

    3-3-1407 – 10:40 hours
    Division 13 to Queens, URGENT, 3rd Alarm, as soon as you get the companies give me a rundown.
    Engs. 254, 331, 225
    Battalion 50
    Battalion 58 (Staging Manager)
    Battalion 42 (Air-Recon Chief)
    Mask Service Unit
    Car 4A( AC James Manahan, Assistant Chief of Operations)

    10:41 hours
    Car 1E (Commissioner’s Liaison) is responding

    10:52 hours
    Car 36A (Department Chaplain) is responding

    10:54 hours – Duration 43 minutes
    DC13: 3rd Alarm Box 1407, we had a 2nd MAYDAY, he used his PSS to escape the building.

    10:55 hours
    Car 11A (BC Thomas J. Richardson, Chief of Rescue Operations) is responding

    11:00 hours – Duration 52 minutes
    FieldCom: Progress report on the Queens 3rd Alarm Box 1407, the address 424 Beach 129 st near Cronston Ave, fire on the 2nd and 3rd floor of a 3 story commercial 30×100. Division 13 reports he has 6 handlines stretched in operation, truck companies continuing to open up and they’re in the process of setting up the tower ladder operation. Fire is Doubtful.

    11:14 hours – Duration 1 hour 5 minutes
    FC: Special call 1 additional truck, have them respond to the staging area.
    TL107 S/C

    11:18 hours – Duration 1 hour 9 minutes
    FC: Progress report on the 3rd Alarm Box 1407, at this time Car 4A, Assistant Chief Manahan reports: a roll call has been conducted and all members are accounted for. Members have been backed out of the building and a tower ladder operation is in progress, and the fire remains Doubtful.

    11:20 hours – Duration 1 hour 11 minutes
    FC: Notify the Buildings Dept. to respond, they want to check the stability of the building.

    11:25 hours
    FC: By authority of the Incident Commander you can 10-2 the Air-Recon Chief.

    11:27 hours – Duration 1 hour 18 minutes
    FieldCom requests mixer-off message

    11:33 hours – Duration 1 hour 24 minutes
    FC: Progress report on the 3rd Alarm Box 1407, at this time Car 4A, Chief Manahan reports that they have 4 handlines in operation, they have 1 tower ladder in operation on exposure 1. Conditions remain the same and searches will be delayed. Fire remains Doubtful.

    11:58 hours – Duration 1 hour 49 minutes
    FC: Progress report on the 3rd Alarm Box 1407, at this time Car 4A, Chief Manahan reports that the safety chief is going to enter the building to assess the stability, searches are delayed, and the fire is now Probably Will Hold.

    12:02 hours
    Car 14C (Fire Marshal) is 10-84

    12:09 hours
    Car 14 (Chief Fire Marshal Robert Byrnes) is 10-84

    12:11 hours
    Car 4A is 10-8, Division 13 is Incident Commander.

    12:32 hours – Duration 2 hours 23 minutes
    FC: Progress report on Box 1407, primary searches on the 2nd and 3rd floors are complete and negative, k, the secondaries are in progress.

    12:36 hours – Duration 2 hours 27 minutes
    FC: Progress report on the 3rd Alarm Box 1407, Division 13 reports: The primary searches throughout the fire building are complete and negative, the secondaries are underway, and the fire is Under Control.

    Relocations
    Engines: 275/265, 319/266, 233/329, 259/331
    Ladders: 155/121, 135/155, 150/134, 120/137, 125/173
    Battalions: 48/43, 51/47, 52/51


    FDNY Radio Codes HERE

    Taking it to the Streets: Near Miss Reporting and One Captain’s Close Call

    No comments

    Taking it to the Streets: Near Miss Reporting and One Captain’s Close Call

    On Your Street, In Your City, Across the Country, Around the WorldTM    

     
     
     
     Join us on Wednesday night March 16th at 9:00 pm ET for an insightful discussion on the National Near-Miss reporting System with a stellar line-up of fire service leaders.

    The line-up of Scheduled guests includes,    

    • Lt. Steve Mormino, FDNY (ret),
    • Captain CJ Haberkorn Denver (CO) Fire Department and
    • Special Guest Captain Michael Long, Camp Taylor (KY) Fire Protection District.

     Grab a cup of coffee and sit down for a special two part, two hour program with Taking it to the Streets on Firefighernetcast.com where we’ll be discussing the National Near-Miss Reporting System and the untapped resources that the program and system provides with Christopher Naum and this outstanding group of fire service leaders.    

    The second part of the program will dedicated to the personal account of Captain Long’s Close Call event from July 25, 2010 (NMR #10-1072) when a catastrophic floor collapse at a residential occupancy plunged him into a fire involved basement.    

     
     

    Join in on the live open discussion with other fire service personnel from around the country. Check out the latest downloads of recent programs in the archives by visiting Taking it to the Street’s webpage on Firefighternetcast.com or for program insights at CommandSafety.com.    

    • Tune in to the Program Wednesday evening March 16th at 9:00 pm ET, HERE
    • Firefighternetcast.com HERE
    • Taking it to the Streets Radio Programs, HERE and HERE 
    • National Near Miss Reporting System, HERE
    • National Near Miss Reporting System Resources, HERE
    • National Near Miss Reporting System, 2011 Calendar and Annual Report, HERE
    • One Captain’s Personal Near Miss Event, HERE
    • Incident Posting from Commandsafety.com from 2010, HERE

    Taking it to the StreetsTM is a monthly radio show featured on BlogTalk Radio and is hosted by Christopher Naum and is a Buildingsonfire.com Series and FireFighternetcast.com Production,    

    © 2011 All Rights Reserved     

        

     

      

       

    Operational Safety at Basement Fires: Close Call

    4 comments

    Basement fires in both residential and commercial occupancies are one of the most challenging tactical operations that present numerous risk factors that required the highest degree of situational awareness, training skill sets and continuous incident monitoring and assessment to gauge building structural integrity, fire behavior and crew integrity and performance. 

    An explosion rocked a Fairdale, Kentucky neighborhood this past weekend while the homeowner was in the process of doing remodeling his basement. A Camp Taylor (KY) firefighter survived a floor collapse that momentarily trapped him proximal to the seat of a working basement fire. Camp Taylor (FD) Captain Mark Long sustained second and third degree leg burns after falling through the floor of the burning home and subsequently being rescue by other fire department personnel. 

    Fellow firefighters, including his brother-in-law, who was right behind him prior to his fall, were yelling and screaming at Long to hang on.  They managed to get a ladder to the basement and it was up to Long to find the strength to get out.  He says “I started to try to climb up. I got two, I lost my grip, fell flat into the fire.  I was so exhausted.” On his third attempt, he did find the strength and pulled himself up the ladder and out of the flames.  

    According to published reports a coordinated fire suppression effort was undertaken, with heavy fire involvement extending throughout the house and into the roof area. Interior fire attack was commenced, and as crews began moving across the first floor area above the seat of the fire, the floor subassembly failed causing an isolated collapse and compromise of the structural floor system and sub-floor decking, resulting in Captain Long falling into the basement. The fire originating in the basement was the result of the homeowners’ use of acetone as a floor treatment when the chemical vapors were ignited by the hot water heater causing an explosion and resulting fire. 

    Safety Considerations related to Residential Occupancies (non-inclusive) 

    • Conduct a thorough fire size-up and communicate the findings to all personnel on-scene before entering the building.
    • Conduct an assessment of the Building Profile ( building construction type, structural assembly systems and features and age) and assesss fire behavior and intensity levels.
    • Ensure an adequte Risk Assessement is conducted and that Risk versus Gain is determined
    • Maintain situational awareness throughout the tactical deployment of crews within the interior of the structure
    • Conduct a 360 degree perimeter assesement when feasible to determine access and egress points, fire location and travel and other mission critical operational perameters.
    • Incident commanders and company officers should be trained and experienced in structure fire size up to avoid putting fire fighters at unneeded risk of working above fire-damaged floors.
    • Do not enter a structure, room, or area when fire is suspected to be directly beneath the floor or area where fire fighters would be operating, or if the location of the fire is unknown.
    • Never assume structural safety of any floor (regardless of the construction) having a significant fire under it.
    • Conduct pre-incident planning inspections during the construction phase to identify the type of floor construction.
    • If pre-planning is not conducted, assume residential construction and small commercial buildings built since the early 1990s may contain engineered wood I-joists.
    • Report construction deficiencies noted during preplanning to local building code officials. For example, engineered wood floor joists should only be modified per manufacturer specifications—usually limited to cutting to length and removing pre–cut knockouts for utility access. Report damaged or cut chords or webs to building officials.
    • Develop, enforce, and follow standard operating procedures (SOPs) on how to size up and combat fires safely in buildings of all construction types. Rapid intervention teams (RIT) should include a portable ladder with their RIT equipment when deployed at basement fires.
    • Ensure Time Compression is considered: Ensure Command has the ability to monitor progress or elapsed incident time and adjusts strategic and tactical plans accordingly and in a time effective manner. 
    • Provide training on identifying signs of weakened floor systems (soft or spongy feel, heat transmitted through floor, downward bowing, etc.).
    • Make fire fighters aware that all floor types can fail with little or no warning.
    • Use a thermal imaging camera to help locate fires burning below or within floor systems, but recognize that the camera cannot be relied upon to assess the strength or safety of the floor. (Refer to the recent UL Test Data and Operational Safety Considerations ”Structural Stability of Engineered Lumber in Fire Conditions” available at http://www.uluniversity.us/ )
    • Fire fighters should be trained on the use of thermal imaging cameras, including limitations and difficulties in detecting fire burning below floor systems. (See reference to UL above)
    • Immediately evacuate and, if possible, use alternate exit routes when floor systems directly beneath the floor where fire fighters would be operating are weakened by fire.
    • Use defensive overhaul procedures after fire extinguishment in structures containing fire-damaged floor systems of all types.
    • Consider becoming active in the building code process and influence requirements for fire resistance of floor and ceiling systems to further fire fighter safety and health.
    • Ensure RIT personnel area staged and have complete a site assessment of the building and occupany upon thier arrival and set-up
    • Ensure that a rapid intervention team (RIT) is on the scene as part of the first alarm and in position to provide immediate assistance prior to crews entering a hazardous environment

    Here are some resources and case studies resulting from operations at floor collapses;

    Incident links; HERE, HERE, HERE and HERE 


     

    What’s On Your Radar Screen?

    11 comments

    BuildingsonFire 2010; Building Construction, Command Risk Management and Operational Safety

    Major Influencing Fire Service Reports, Issues or Focus that should be on Your Radar Screen

    The following list is but a modest cross section of pertinent information or focus areas today’s Firefighter, Company or Command Officer MUST be knowledgeable in, have insights and proficiency based technical skills to function with a level of competencies demanded in  today’s  fire service.

    If these are not on your radar screen or you haven’t got a blip of a clue what they’re about; then you are derelict and not doing your job- and the end result could be a less than desirable outcome on the fireground; it’s that simple, it’s that direct.

    Have you read these reports, understand the issues & influences, increased your knowledge, skills and abilities in any gap areas or taken the time to research the cutting edge issues affecting today’s fire service?

    The City of Charleston Sofa Super Store LODD-Routley Fire Report

    Read the report; understand the incident, the building performance, the fire behavior and the operation process deployed. Gain the insights from the overall apparent and contributing causes identified and presented and assess how these relate to your fire service perspective and department’s culture and performance today.

    • City of Charleston Post Incident Assessment and Review Team Phase I Report, HERE
    • Routley Final Phase II Report HERE
    • NIOSH Investigative Report, HERE
    • NIOSH REPORT SUMMARY
    • NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should:
    • develop, implement and enforce written standard operating procedures (SOPs) for an occupational safety and health program in accordance with NFPA 1500
    • develop, implement, and enforce a written Incident Management System to be followed at all emergency incident operations
    • develop, implement, and enforce written SOPs that identify incident management training standards and requirements for members expected to serve in command roles
    • ensure that the Incident Commander is clearly identified as the only individual with overall authority and responsibility for management of all activities at an incident
    • ensure that the Incident Commander conducts an initial size-up and risk assessment of the incident scene before beginning interior fire fighting operations
    • train fire fighters to communicate interior conditions to the Incident Commander as soon as possible and to provide regular updates
    • ensure that the Incident Commander establishes a stationary command post, maintains the role of director of fireground operations, and does not become involved in fire-fighting efforts
    • ensure the early implementation of division / group command into the Incident Command System
    • ensure that the Incident Commander continuously evaluates the risk versus gain when determining whether the fire suppression operation will be offensive or defensive
    • ensure that the Incident Commander maintains close accountability for all personnel operating on the fireground
    • ensure that a separate Incident Safety Officer, independent from the Incident Commander, is appointed at each structure fire
    • ensure that crew integrity is maintained during fire suppression operations
    • ensure that a rapid intervention crew (RIC) / rapid intervention team (RIT) is established and available to immediately respond to emergency rescue incidents
    • ensure that adequate numbers of staff are available to immediately respond to emergency incidents
    • ensure that ventilation to release heat and smoke is closely coordinated with interior fire suppression operations
    • conduct pre-incident planning inspections of buildings within their jurisdictions to facilitate development of safe fireground strategies and tactics
    • consider establishing and enforcing standardized resource deployment approaches and utilize dispatch entities to move resources to fill service gaps
    • develop and coordinate pre-incident planning protocols with mutual aid departments
    • ensure that any offensive attack is conducted using adequate fire streams based on characteristics of the structure and fuel load present
    • ensure that an adequate water supply is established and maintained
    • consider using exit locators such as high intensity floodlights or flashing strobe lights to guide lost or disoriented fire fighters to the exit
    • ensure that Mayday transmissions are received and prioritized by the Incident Commander
    • train fire fighters on actions to take if they become trapped or disoriented inside a burning structure
    • ensure that all fire fighters and line officers receive fundamental and annual refresher training according to NFPA 1001 and NFPA 1021
    • implement joint training on response protocols with mutual aid departments
    • ensure apparatus operators are properly trained and familiar with their apparatus
    • protect stretched hose lines from vehicular traffic and work with law enforcement or other appropriate agencies to provide traffic control
    • ensure that fire fighters wear a full array of turnout clothing and personal protective equipment appropriate for the assigned task while participating in fire suppression and overhaul activities
    • ensure that fire fighters are trained in air management techniques to ensure they receive the maximum benefit from their self-contained breathing apparatus (SCBA)
    • develop, implement and enforce written SOPS to ensure that SCBA cylinders are fully charged and ready for use
    • use thermal imaging cameras (TICs) during the initial size-up and search phases of a fire
    • develop, implement and enforce written SOPs and provide fire fighters with training on the hazards of truss construction
    • establish a system to facilitate the reporting of unsafe conditions or code violations to the appropriate authorities
    • ensure that fire fighters and emergency responders are provided with effective incident rehabilitation
    • provide fire fighters with station / work uniforms (e.g., pants and shirts) that are compliant with NFPA 1975 and ensure the use and proper care of these garments.

    Additionally, federal and state occupational safety and health administrations should:

    • consider developing additional regulations to improve the safety of fire fighters, including adopting National Fire Protection Association (NFPA) consensus standards.

    Additionally, manufacturers, equipment designers, and researchers should:

    • continue to develop and refine durable, easy-to-use radio systems to enhance verbal and radio communication in conjunction with properly worn SCBA
    • conduct research into refining existing and developing new technology to track the movement of fire fighters inside structures.

    Additionally, code setting organizations and municipalities should:

    • require the use of sprinkler systems in commercial structures, especially ones having high fuel loads and other unique life-safety hazards, and establish retroactive requirements for the installation of fire sprinkler systems when additions to commercial buildings increase the fire and life safety hazards
    • require the use of automatic ventilation systems in large commercial structures, especially ones having high fuel loads and other unique life-safety hazards.

    Additionally, municipalities and local authorities having jurisdiction should:

    • coordinate the collection of building information and the sharing of information between building authorities and fire departments
    • consider establishing one central dispatch center to coordinate and communicate activities involving units from multiple jurisdictions
    • ensure that fire departments responding to mutual aid incidents are equipped with mobile and portable communications equipment that are capable of handling the volume of radio traffic and allow communications among all responding companies within their jurisdiction.

    Everyone Goes Home Campaign

    • Everyone Goes Home® is a national program by the National Fallen Firefighters Foundation to prevent line-of-duty deaths and injuries. In March 2004, a Firefighter Life Safety Summit was held to address the need for change within the fire service. At this summit, the 16 Firefighter Life Safety Initiatives were created and a program was born to ensure that Everyone Goes Home®.
    • Recognizing the need to do more to prevent line-of-duty deaths and injuries, the National Fallen Firefighters Foundation has launched a national initiative to bring prevention to the forefront.
    • In March 2004, the Firefighter Life Safety Summit was held in Tampa, Florida to address the need for change within the fire and emergency services. Through this meeting, 16 Life Safety Initiatives were produced to ensure that Everyone Goes Home®.
    • The first major action was to sponsor a national gathering of fire and emergency services leaders. The National Fallen Firefighters Foundation will play a major role in helping the U.S. Fire Administration meet its stated goal to reduce the number of preventable firefighter fatalities. The Foundation sees fire service adoption of the summit’s initiatives as a vital step in meeting this goal.
    • The Courage to Be Safe® On-Line Program , HERE
    • Media CenterUsing variations of the Courage to Be Safe ®…So Everyone Goes Home® field program, along with material from the Firefighter Life Safety Initiatives Resource Kit we will develop and deploy a new online learning segment each month. These online learning segments will allow you to expand upon your personal and professional development when you want and how you want. Watch them by yourself or integrate them into your organizational training programs. Remember, that safety results from constant training and putting those skills to work everyday, on every call – SO EVERYONE GOES HOME. HERE
    • The Firefighter Life Safety Initiatives Advocates Program will play a key role in helping to bring about awareness of the Initiatives and act as a conduit for resources to enable departments to implement and advocate them. HERE
    • The 16 Fire Fighter Life Safety Initiatives
      1. Define and advocate the need for a cultural change within the fire service relating to safety; incorporating leadership, management, supervision, accountability and personal responsibility.
      2. Enhance the personal and organizational accountability for health and safety throughout the fire service.
      3. Focus greater attention on the integration of risk management with incident management at all levels, including strategic, tactical, and planning responsibilities.
      4. All firefighters must be empowered to stop unsafe practices.
      5. Develop and implement national standards for training, qualifications, and certification (including regular recertification) that are equally applicable to all firefighters based on the duties they are expected to perform.
      6. Develop and implement national medical and physical fitness standards that are equally applicable to all firefighters, based on the duties they are expected to perform.
      7. Create a national research agenda and data collection system that relates to the initiatives.
      8. Utilize available technology wherever it can produce higher levels of health and safety.
      9. Thoroughly investigate all firefighter fatalities, injuries, and near misses.
      10. Grant programs should support the implementation of safe practices and/or mandate safe practices as an eligibility requirement.
      11. National standards for emergency response policies and procedures should be developed and championed.
      12. National protocols for response to violent incidents should be developed and championed.
      13. Firefighters and their families must have access to counseling and psychological support.
      14. Public education must receive more resources and be championed as a critical fire and life safety program.
      15. Advocacy must be strengthened for the enforcement of codes and the installation of home fire sprinklers.
      16. Safety must be a primary consideration in the design of apparatus and equipment.

    NIST Wind Driven Fire Study

    • Smoke and heat spreading through the corridors and the stairs of a building during a fire can limit building occupants’ ability to escape and can limit fire fighters’ ability to rescue them.  Changes in the building’s ventilation or presence of an external wind can increase the energy release of the fire.  This can also increase the spread of fire gases through the building.  In some cases, such as the Cook County Administration Building fire in October 2003, the fire gas flow, into the corridors and the stairway prevented fire fighters from suppressing the fire from inside the structure.  This fire resulted in 6 building occupant fatalities and fire fighter injuries in the stairway.  The Fire Department of New York City has experienced many wind driven fire incidents which have resulted in fire fighter fatalities and injuries, as have a number of other incidents nationally that have resulted in increased research into this operational and tactical challenge.
    • What tactics or tools are appropriate for use with a wind driven fire and how should the tactics or tools be implemented?  Positive Pressure Ventilation (PPV) is being used by fire departments on smaller structures, such as single family homes, to control the fire flow by introducing pressure from the front door and venting the house through a strategic exit opening.  If done correctly, this tactic can remove significant amounts of heat and smoke from the structure, thus improving the fire fighters’ working environment and improving the chances of survival for the building occupants.  NIST has completed several studies which have a two fold impact: 1) providing guidance on the safe use of PPV and 2) characterizing and validating the modeling of PPV with a computational fluid dynamics (CFD) computer model, so that the model can be used as a training tool for the fire service.
    • This project extends previous work for ventilation under wind driven conditions.  There are many questions regarding wind driven fires.  For example can these PPV fans be used successfully under wind driven fire conditions in large structures?  Large structures, such as high rise buildings, provide additional challenges to fire fighter and building occupant safety: increased travel distance (exposure time), more complicated egress path, and potentially larger fires.  In 2002 there were 7,300 reported fires in high rise structures.
    • Other tactics incorporating devices, such as wind control devices (WCD) to control the ventilation conditions or the use of a “high rise” nozzle from the floor below the fire floor have been tried by the fire service under “real fire” conditions with varying levels of success.
    • A comprehensive free DVD set from the NIST includes a presentation video that explains PPV, examines the results of NIST’s PPV research, and closes with a focus on the use of PPV tactics in high-rise buildings.  All of the NIST PPV reports referenced in the presentation are included on Disc 1 of the set.  All of the videos from the high-rise fire experiments are also provided with a user-friendly, graphic menu that can be used on a PC or a DVD player.  NIST, with support from USFA, DHS, and fire departments across the country, has taken engineering principles and applied them to fire service PPV tactics in order to improve fire fighter safety
    • NIST References HERE and HERE

    NIST Fire Fighting Tactics Under Wind Driven Conditions: Laboratory Experiments

    • A series of experiments was conducted in our Large Fire Laboratory to examine the impact of wind control curtains and externally applied hose streams on a wind driven fire.  The results from these experiments will allow us to better understand the fire dynamics within a structure and provide guidance as to the important measurements needed in the future experiments in a high-rise on Governor’s Island in New York City.
    • Fire Fighting Tactics Under Wind Driven Conditions Report, HERE
    • Reference Data HERE

    NIST Firefighter Safety and Deployment Study; Report on Residential Fireground Field Experiments

    • The NIST Firefighter Safety and Deployment Study; Titled- Report on Residential Fireground Field Experiments was recently released to the public providing . A copy of the report is attached.
    • Report Abstract:
    • Service expectations placed on the fire service, including Emergency Medical Services (EMS), response to natural disasters, hazardous materials incidents, and acts of terrorism, have steadily increased. However, local decision-makers are challenged to balance these community service expectations with finite resources without a solid technical foundation for evaluating the impact of staffing and deployment decisions on the safety of the public and firefighters. For the first time, this study investigates the effect of varying crew size, first apparatus arrival time, and response time on firefighter safety, overall task completion, and interior residential tenability using realistic residential fires.
    • This study is also unique because of the array of stakeholders and the caliber of technical experts involved. Additionally, the structure used in the field experiments included customized instrumentation; all related industry standards were followed; and robust research methods were used. The results and conclusions will directly inform the NPFA 1710 Technical Committee, who is responsible for developing consensus industry deployment standards.
    • This report presents the results of more than 60 laboratory and residential fireground experiments designed to quantify the effects of various fire department deployment configurations on the most common type of fire—a low hazard residential structure fire. For the fireground experiments, a 2,000 sq ft (186 m2), two-story residential structure was designed and built at the Montgomery County Public Safety Training Academy in Rockville, MD. Fire crews from Montgomery County, MD and Fairfax County.
    • Report results quantify the effectiveness of crew size, first-due engine arrival time, and apparatus arrival stagger on the duration and time to completion of the key 22 fireground tasks and the effect on occupant and firefighter safety.
    • The report is also available for download at the NIST, HERE
    • Synopsis HERE

    USFA/NIST Trends in Firefighter Fatalities Due to Structural Collapse, 1979-2002

    • Between the years 1979 and 2002 there were over 180 firefighter fatalities due to structural collapse, not including those firefighters lost in 2001 in the collapse of the World Trade Center Towers. Structural collapse is an insidious problem within the fire fighting community. It often occurs without warning and can easily cause multiple fatalities.
    • As part of a larger research program to help reduce firefighter injuries and fatalities the U.S. Fire Administration (USFA) funded the National Institute of Standards and Technology (NIST) to examine records and determine if there were any trends and/or patterns that could be detected in firefighter fatalities due to structural collapse. If so, these trends could be brought immediately to the attention of training officers and incident commanders and investigated further to determine probable causes.
    • Report: Trends in Firefighter Fatalities Due to Structural Collapse1979-2002
    • Report: Early Warning Capabilities for Firefighters:Testing of Collapse Prediction Technologies

    UL Fire Academy CBT

    • UL Structural Stability of Engineered Lumber in Fire Conditions
    • Base on the UL research and
    • This two-hour presentation summarizes a research study on the hazards posed to firefighters by the use of lightweight construction and engineered lumber in floor and roof designs. This free on-line computer based presentation will allow fire professionals to better interpret fire hazards and assess risk for life safety of building occupants and firefighters.
    • This online firefighter training course is the result of a research partnership among UL, the Chicago Fire Department, IAFC, and Michigan State University, funded in part by the U.S. Department of Homeland Security. This self-guided course, which focuses on the structural stability of engineered lumber under fire conditions, is targeted toward the 1.1 million fire service personnel in the United States and Canada. The knowledge developed and shared in this course is critically important to firefighter and civilian safety.
    • This two-hour presentation summarizes a research study on the hazards posed to firefighters by the use of lightweight construction and engineered lumber in floor and roof designs. This free on-line computer based presentation will allow fire professionals to better interpret fire hazards and assess risk for life safety of building occupants and firefighters.
    • Program Objectives:
    • Provide brief history of events leading up to DHS Grant tests
    • Identify the fire test hypothesis, parameters, and steps completed in the testing process
    • Compare tests results (legacy vs. modern construction)
    • Communicate learnings from our partners representing the fire service
    • Discuss code recommendations
    • UL University on-line Program HERE

    USFA/NIST Trends in Firefighter Fatalities Due to Structural Collapse, 1979-2002

    • Between the years 1979 and 2002 there were over 180 firefighter fatalities due to structural collapse, not including those firefighters lost in 2001 in the collapse of the World Trade Center Towers. Structural collapse is an insidious problem within the fire fighting community. It often occurs without warning and can easily cause multiple fatalities.
    • As part of a larger research program to help reduce firefighter injuries and fatalities the U.S. Fire Administration (USFA) funded the National Institute of Standards and Technology (NIST) to examine records and determine if there were any trends and/or patterns that could be detected in firefighter fatalities due to structural collapse. If so, these trends could be brought immediately to the attention of training officers and incident commanders and investigated further to determine probable causes.
    • Report: Trends in Firefighter Fatalities Due to Structural Collapse1979-2002
    • Report: Early Warning Capabilities for Firefighters:Testing of Collapse Prediction Technologies

    NIOSH LODD Reports

    • Each year an average of 105 fire fighters die in the line of duty. To address this continuing national occupational fatality problem, NIOSH conducts independent investigations of fire fighter line of duty deaths. The dedicated web page provides access to NIOSH investigation reports and other fire fighter safety resources.
    • NIOSH Web Page HERE
    • Through the Fire Fighter Fatality Investigation and Prevention Program, NIOSH conducts investigations of fire fighter line-of-duty deaths to formulate recommendations for preventing future deaths and injuries. The program does not seek to determine fault or place blame on fire departments or individual fire fighters, but to learn from these tragic events and prevent future similar events.
    • Fire Fighter Fatality Investigation Reports, HERE

    NIOSH Alert: Preventing Deaths and Injuries of Fire Fighters using Risk Management Principles at Structure Fires

    • Fire fighters are often killed or injured when fighting fires in abandoned, vacant, and unoccupied structures.
    • These structures pose additional and sometimes unique risks due to the potential for fire fighters to encounter unexpected and unsafe building conditions such as dilapidation, decay, damage from previous fires and vandals, and other factors such as uncertain occupancy status. Risk management principles must be applied at all structure fires to ensure the appropriate strategy and tactics are used based on the fireground conditions encountered.
    • Report HERE

    NIOSH Report; Preventing Deaths and Injuries of Fire Fighters Working Above Fire Damaged Floors

    • Fire fighters are at risk of falling through fire-damaged floors. Fire burning underneath floors can significantly degrade the floor system with little indication to fire fighters working above.
    • Floors can fail within minutes of fire exposure, and new construction technology such as engineered wood floor joists may fail sooner than traditional construction methods.
    • NIOSH recommends that fire fighters use extreme caution when entering any structure that may have fire burning beneath the floor.
    • Report HERE

    NIOSH ALERT: Preventing Injuries and Deaths of Fire Fighters due to Truss System Failures

    • Fire fighters may be injured and killed when fire-damaged roof and floor truss systems collapse, sometimes without warning.
    • The National Institute for Occupational Safety and Health (NIOSH) requests assistance in preventing injuries and deaths of fire fighters due to roof and floor truss collapse during fire-fighting operations. Roof and floor truss system collapses in buildings that are on fire cannot be predicted and may occur without warning.
    • NIOSH recommends that fire departments review their occupational safety programs and standard operating procedures to ensure they include safe work practices in and around structures that contain trusses. Building owners should follow proper building codes and consider posting building construction information outside a building to advise fire fighters of the conditions they may encounter.
    • ALERT Report HERE

    National Near Miss Reporting System (NNMRS) Operating Experience

    • The National Fire Fighter Near-Miss Reporting System is a voluntary, confidential, non-punitive and secure reporting system with the goal of improving fire fighter safety.
    • Submitted reports will be reviewed by fire service professionals. Identifying descriptions are removed to protect your identity. The report is then posted on this web site for other fire fighters to use as a learning tool.
    • National Fire Fighter Near-Miss Reporting System Web Site, HERE
    • Search Reports, HERE
    • Resources, HERE

    USFA Incident Reports (Stop History Repeating Events-HRE)

    • USFA provides information resources in many formats, including books, pamphlets and DVD’s, free of charge.
    • The U.S. Fire Administration develops reports on selected major fires throughout the country. The fires usually involve multiple deaths or a large loss of property. But the primary criterion for deciding to do a report is whether it will result in significant “lessons learned.” In some cases these lessons bring to light new knowledge about fire–the effect of building construction or contents, human behavior in fire, etc. In other cases, the lessons are not new but are serious enough to highlight once again, with yet another fire tragedy report. In some cases, special reports are devel­oped to discuss events, drills, or new technologies which are of interest to the fire service.
    • The reports are sent to fire magazines and are distributed at National and Regional fire meetings. The International Association of Fire Chiefs assists the USFA in disseminating the findings throughout the fire service. On a continuing basis the reports are available on request from the USFA; announce­ments of their availability are published widely in fire journals and newsletters
    • This body of work provides detailed information on the nature of the fire problem for policymakers who must decide on allocations of resources between fire and other pressing problems, and within the fire service to improve codes and code enforcement, training, public fire education, building technology, and other related areas.
    • The Fire Administration, which has no regulatory authority, sends an experienced fire investigator into a community after a major incident only after having conferred with the local fire authorities to insure that the assistance and presence of the USFA would be supportive and would in no way interfere with any review of the incident they are themselves conducting. The intent is not to arrive during the event or even immediately after, but rather after the dust settles, so that a complete and objective review of all the important aspects of the incident can be made
    • Technical Reports and On-line Publications, HERE

    Prince William County (VA) Fire Rescue Kyle Wilson LODD Report

    • The Prince William County (VA) Department of Fire and Rescue published a comprehensive line of duty death report for Technician I Kyle R. Wilson on Saturday, January 26, 2008. Technician I Wilson was the first line of duty death in the Department’s 41-year history. The Department is sharing the LODD Investigative Report to honor Kyle, and in an effort to reduce and prevent firefighter line of duty deaths at the local, region, state, and national levels.
    • Technician Kyle Robert Wilson was 24-years old and was born in Olney, Maryland. He grew up in Prince William County and graduated from Hylton High School and George Mason University. He was an avid baseball and softball player. Technician Wilson joined the Prince William County Department of Fire and Rescue on January 23, 2006. Technician Kyle Wilson died in the line of duty on April 16, 2007 while performing search and rescue operations at a house fire on Marsh Overlook Drive, located in the Woodbridge area of Prince William County. On that day, Technician Wilson was part of the firefighter staffing on Tower 512 which responded to the house fire that was dispatched at 0603 hours. The Prince William County area was under a high wind advisory as a nor’eastern storm moved through the area. Sustained winds of 25 mph with gusts up to 48 mph were prevalent in the area at the time of the fire dispatch to Marsh Overlook Drive.
    • Initial arriving units reported heavy fire on the exterior of two sides of the single family house and crews suspected that the occupants were still inside the house sleeping because of the early morning hour. A search of the upstairs bedroom commenced for the possible victims. A rapid and catastrophic change of fire and smoke conditions occurred in the interior of the house within minutes of Tower 512’s crew entering the structure.
    • Technician Wilson became trapped and was unable to locate an immediate exit out of the hostile environment. Mayday radio transmissions were made by crews and by Technician Kyle Wilson of the life-threatening situation. Valiant and repeated rescue attempts to locate and remove Technician Wilson were made by the firefighting crews during extreme fire, heat and smoke conditions. Firefighters were forced from the structure as the house began to collapse on them and intense fire, heat and smoke conditions developed. Technician Wilson succumbed to the fire and the cause of death was reported by the medical examiner to be thermal and inhalation injuries.
    • The Department of Fire and Rescue immediately formed a multi-dimensional investigation team following the incident. The investigation team was comprised of five Department of Fire and Rescue uniform personnel and two external members from area fire departments. For eight months, the team thoroughly examined the events that occurred at the Marsh Overlook fire incident and identify the factors involved with the line of duty death of Technician I Kyle Wilson. The resulting report represents thousands of hours of effort to analyze fire and rescue operations and is a factual representation of the events that occurred. The report also provides a frame work for organizational level improvements.
    • The major factors in the line of duty death of Technician I Wilson were determined to be:
      • The initial arriving fire suppression force size.
      • The size up of fire development and spread.
      • The impact of high winds on fire development and spread.
      • The large structure size and lightweight construction and materials.
      • The rapid intervention and firefighter rescue efforts.
      • The incident control and management.
      • The Marsh Overlook fire incident was an immense fire fueled by extremely flammable building material products and a vicious wind. It was an environment where information gathering and decision making had to be performed in the time measurement of seconds. During the chain of events that occurred and under severe circumstances, fire and rescue personnel performed at exceptional levels.
    • During the repeated attempts to reach and rescue Technician I Wilson, personnel displayed heroic efforts and jeopardized their own safety. The Department will never forget the sacrifice that Technician Wilson made in an attempt to ensure others were safe. By sharing the knowledge gained from this very tragic and painful incident, the Department will ensure his sacrifice was not in vain and hope that other fire and rescue departments can avoid another similar occurrence.
    • Resources and Report

    Loudoun County (VA) Fire Rescue  Significant Near Miss Event Report

    • On May 25, 2008, fire and rescue personnel from Loudoun County responded to a structure fire at 43238 Meadowood Court in Leesburg, Virginia. During the course of the incident, seven responders were injured. Of those injured, four firefighters received significant burn injuries, two firefighters sustained orthopedic injuries, and one EMS provider was treated for minor respiratory distress. To date, five of the injured personnel have returned to duty. Two firefighters continue to recover from their injuries, including one who was severely burned.
    • Given the severity of the injuries and magnitude of the event, an independent Investigative Team was assembled to review the incident. The Team was comprised of four Loudoun County personnel, three external members from area fire departments, and two resource/support personnel. The Team was tasked with reviewing “the events leading up to the incident, the incident operation(s), the firefighter MAYDAY(s), and incident mitigation.”
    • For three months, the Team thoroughly examined the events surrounding the Meadowood Court fire incident and identified the factors associated with the injury of personnel.
    • The Report contains the results of the Investigative Team’s comprehensive review and analysis.
    • Fact Sheet, HERE
    • SIGNIFICANT INJURY INVESTIGATIVE REPORT 43238 MEADOWOOD COURT MAY 25, 2008 Report HERE

    Worcester (MA) Fire Cold Storage Fire LODD Report; Abandoned Cold Storage Warehouse Multi-Firefighter Fatality Fire 1999, Worcester, Massachusetts

    • A technical review of the 1999 Worcester, MA fire that claimed six firefighters concludes that abandoned buildings are a serious threat to firefighters and fire departments must make a concerted effort to use technology to maintain data on buildings in their response districts.
    • On Friday, December 3, 1999, at 1813 hours, the Worcester, Massachusetts Fire Department dis­patched Box 1438 for 266 Franklin Street, the Worcester Cold Storage and Warehouse Co. A motor­ist had spotted smoke coming from the roof while driving on an adjacent elevated highway. The original building was constructed in 1906, contained another 43,000 square feet. Both were 6 stories above grade. The building was known to be abandoned for over 10 years.
    • Eleven minutes into the fire, the owner of the abutting Kenmore Diner advised fire operations of two homeless people who might be living in the warehouse. The rescue company, having divided into two crews, started a building search. Some 22 minutes later the rescue crew searching down from the roof became lost in the vast dark spaces of the fifth floor. They were running low on air and called for help. Interior conditions were deteriorating rapidly despite efforts to extinguish the blaze, and visibility was nearly lost on the upper floors. Investigators have placed these two firefighters over 150 feet from the only available exit.
    • An extensive search was conducted by Worcester Fire crews through the third and fourth alarms. Suppression efforts continued to be ineffective against huge volumes of petroleum based materials, and ultimately two more crews became disoriented on the upper floors and were unable to escape. When the evacuation order was given one hour and forty-five minutes into the event, five firefighters and one officer were missing. None survived.
    • A subsequent exterior attack was set up and lasted for over 20 hours utilizing aerial pieces and del­uge guns from Worcester and neighboring departments. Task force groups from across the State of Massachusetts responded to initial suppression and subsequent recovery efforts. During this time, the four upper floors collapsed onto the second which became known as “the deck”. Over 6 million gallons of water were used during the suppression efforts. According to NFPA records, this is the first loss of six firefighters in a structure fire where neither building collapse nor an explosion was a contributing factor to the fatalities.
    • USFA Report HERE

    Colerain Township (OH) Fire and EMS Department Final Report Investigation Analysis of the Squirrels Nest Lane Firefighter Line of Duty Deaths

    • The Colerain Township (OH) Fire and EMS Department under the leadership of Director and Chief G. Bruce Smith recently released its final report Investigation Analysis of the Squirrels nest Lane Firefighter Line of Duty Deaths related to the April 4, 2008 Double Line of Duty Death of a Captain and Firefighter.  This investigative analysis and report, although specific to the events and conditions encountered during the conduct of operation at the residential occupancy at 5708 Squirrels nest Lane has pertinent and relevant insights, recommendations and factors that all Fire Service personnel, regardless of rank should read.
    • Incident Overview, HERE
    • NIOSH Report, HERE
    • Investigative Report, HERE

    Field Trips

    • Take a good look at the structures, occupancies and  buildings in you first, second and third due areas, look around your community and jurisdiction as well as your mutual aid and greater alarm response box areas.
    • Have you stopped for a minute today and taken a good look around? Whether you’re sitting in the front seat at the stop light of an intersection or as you’re peering out the side cab window coming back from an alarm or while running errands in your POV; have you taken a good look around? As the Springsteen song goes; “this is your town”.
    • There’s a lot that can be gleaned from your surroundings on any given day. We sometimes take for granted the subtle changes that are happening all around us as we take care of business on our rounds, runs and calls. We tend to focus in on the immediacy of the events that are happening in front of us that demand our attention but fail to take a look around to pick up on information, data and insights that can help us on that next run or down the road in the future.
    • Take a look at the construction that might be going up in your areas. I’m certain you’re paying close attention to what’s happening in your first-due, but what about that third-due area, that neighboring jurisdiction or the mutual-aid area that you occasionally run in to? When you’re on that next EMS run or an investigation of an odor or alarm bells service call, take a few extra minutes to walk through the occupancy. Conduct your own mini company level pre-plan.
    • Look at the layout, features, access and construction features. If you have a chance, verify the structural support systems employed by the building for the floor and roof systems. If you have time, take the company on a quick site visit to that building that’s under construction or the renovations that are again underway in that commercial or business occupancy around the corner from quarters.
    • These continuing challenging economic times places a great deal of influence on what’s being built, how it might be constructed, the manner in which a building may be operational one day, vacant the other and under renovation the next. Sometimes these transformations occur literally overnight.
    • Take a good look around, this is your town…your district, your response area. Know your buildings, understand their performance profiles, and assess the predictability of performance. Remember; Building Knowledge = Firefighter Safety.

    Building Construction

    I continue to suggest that it’s no longer just brute force and sheer physical determination that define structural fire suppression operations, although any seasoned firefighter and company officer knows that at times; it is what gets the job done under the most arduous and demanding of circumstances. However, from a methodical and disciplined perspective, aggressive firefighting must be redefined and aligned to the built environment and associated with goal oriented tactical operations that are defined by risk assessed and analyzed tasks that are executed under battle plans that promote the best in safety practices and survivability within know hostile structural fire environments.

    We can still meet the demands of the job, as firefighters; but do it with Tactical Patience and not at the expense of Command Compression and Tactical Entertainment or worst Operational Recklessness.

    The traditional attitudes and beliefs of equating aggressive firefighting operations in all occupancy types coupled with the correlating, established and pragmatic operational strategies and tactics must be adjusted and modified to include intelligent risk assessment, calculated risk analysis, safety and survivability profiling, and strategic operational and tactical value. The demands and requirements of modern firefighting will continue to require the placement of personnel within situations and buildings that carry risk, uncertainty and inherent danger. As a result, risk management must become fluid and integrated with intelligent tactical deployments and operations recognizing the risk problematically and not fatalistically, resulting in safety conscious strategies and tactics. We need to think about the Predicative Strategic Process, refined Tactical Deployment Models integrating intelligent Structural Anatomy and Predictive Occupancy Profiling.

    Without understanding the building-occupancy relationships and integrating; construction, occupancies, fire dynamics and fire behavior, risk, analysis, the art and science of firefighting, safety conscious work environment concepts and effective and well-informed incident command management, company level supervision and task level competencies…You are derelict and negligent and “not “everyone may be going home”. Our current generation of buildings, construction and occupancies are not as predictable as past conventional construction; risk assessment, strategies and tactics must adjusted and enhanced to address these new rules of structural fire engagement. There is a profound need to gain building construction knowledge and insights and to change and adjust operating profiles in order to safe guard companies, personnel and team compositions. It’s all about understanding the building-occupancy relationships and the art and science of firefighting, Building Knowledge = Firefighter Safety. Its all about the new formula….Bk=F2S.

    Additionally, think about the following

    • Don’t Treat Your Buildings and Occupancies the Same anymore
    • Increase Situational Awareness
    • Increase Your Competencies
    • Know Your Buildings
    • Be aware of Command Compression
    • Implement Tactical Patience
    • Tactical Entertainment
    • Building Knowledge = Firefighter Safety
    • Fire Behavior & Fire Dynamics
    • Situational Awareness
    • Naturalistic Decision Making

    More on these and some additional key reports on a future post…..