Operational Safety at Basement Fires: Close Call

4 comments

Basement fires in both residential and commercial occupancies are one of the most challenging tactical operations that present numerous risk factors that required the highest degree of situational awareness, training skill sets and continuous incident monitoring and assessment to gauge building structural integrity, fire behavior and crew integrity and performance. 

An explosion rocked a Fairdale, Kentucky neighborhood this past weekend while the homeowner was in the process of doing remodeling his basement. A Camp Taylor (KY) firefighter survived a floor collapse that momentarily trapped him proximal to the seat of a working basement fire. Camp Taylor (FD) Captain Mark Long sustained second and third degree leg burns after falling through the floor of the burning home and subsequently being rescue by other fire department personnel. 

Fellow firefighters, including his brother-in-law, who was right behind him prior to his fall, were yelling and screaming at Long to hang on.  They managed to get a ladder to the basement and it was up to Long to find the strength to get out.  He says “I started to try to climb up. I got two, I lost my grip, fell flat into the fire.  I was so exhausted.” On his third attempt, he did find the strength and pulled himself up the ladder and out of the flames.  

According to published reports a coordinated fire suppression effort was undertaken, with heavy fire involvement extending throughout the house and into the roof area. Interior fire attack was commenced, and as crews began moving across the first floor area above the seat of the fire, the floor subassembly failed causing an isolated collapse and compromise of the structural floor system and sub-floor decking, resulting in Captain Long falling into the basement. The fire originating in the basement was the result of the homeowners’ use of acetone as a floor treatment when the chemical vapors were ignited by the hot water heater causing an explosion and resulting fire. 

Safety Considerations related to Residential Occupancies (non-inclusive) 

  • Conduct a thorough fire size-up and communicate the findings to all personnel on-scene before entering the building.
  • Conduct an assessment of the Building Profile ( building construction type, structural assembly systems and features and age) and assesss fire behavior and intensity levels.
  • Ensure an adequte Risk Assessement is conducted and that Risk versus Gain is determined
  • Maintain situational awareness throughout the tactical deployment of crews within the interior of the structure
  • Conduct a 360 degree perimeter assesement when feasible to determine access and egress points, fire location and travel and other mission critical operational perameters.
  • Incident commanders and company officers should be trained and experienced in structure fire size up to avoid putting fire fighters at unneeded risk of working above fire-damaged floors.
  • Do not enter a structure, room, or area when fire is suspected to be directly beneath the floor or area where fire fighters would be operating, or if the location of the fire is unknown.
  • Never assume structural safety of any floor (regardless of the construction) having a significant fire under it.
  • Conduct pre-incident planning inspections during the construction phase to identify the type of floor construction.
  • If pre-planning is not conducted, assume residential construction and small commercial buildings built since the early 1990s may contain engineered wood I-joists.
  • Report construction deficiencies noted during preplanning to local building code officials. For example, engineered wood floor joists should only be modified per manufacturer specifications—usually limited to cutting to length and removing pre–cut knockouts for utility access. Report damaged or cut chords or webs to building officials.
  • Develop, enforce, and follow standard operating procedures (SOPs) on how to size up and combat fires safely in buildings of all construction types. Rapid intervention teams (RIT) should include a portable ladder with their RIT equipment when deployed at basement fires.
  • Ensure Time Compression is considered: Ensure Command has the ability to monitor progress or elapsed incident time and adjusts strategic and tactical plans accordingly and in a time effective manner. 
  • Provide training on identifying signs of weakened floor systems (soft or spongy feel, heat transmitted through floor, downward bowing, etc.).
  • Make fire fighters aware that all floor types can fail with little or no warning.
  • Use a thermal imaging camera to help locate fires burning below or within floor systems, but recognize that the camera cannot be relied upon to assess the strength or safety of the floor. (Refer to the recent UL Test Data and Operational Safety Considerations ”Structural Stability of Engineered Lumber in Fire Conditions” available at http://www.uluniversity.us/ )
  • Fire fighters should be trained on the use of thermal imaging cameras, including limitations and difficulties in detecting fire burning below floor systems. (See reference to UL above)
  • Immediately evacuate and, if possible, use alternate exit routes when floor systems directly beneath the floor where fire fighters would be operating are weakened by fire.
  • Use defensive overhaul procedures after fire extinguishment in structures containing fire-damaged floor systems of all types.
  • Consider becoming active in the building code process and influence requirements for fire resistance of floor and ceiling systems to further fire fighter safety and health.
  • Ensure RIT personnel area staged and have complete a site assessment of the building and occupany upon thier arrival and set-up
  • Ensure that a rapid intervention team (RIT) is on the scene as part of the first alarm and in position to provide immediate assistance prior to crews entering a hazardous environment

Here are some resources and case studies resulting from operations at floor collapses;

Incident links; HERE, HERE, HERE and HERE 


 

In the Streets; On the Air

1 comment

Taking it to the Streets had its premier July 21st on Firefighter Netcast.com with a lively and provoking discussion on “What’s on YOUR Radar Screen?” The program theme aligned with a recent posting on the same topic. Join me on the program were two prominent and nationally recognized fire service leaders, who I’m honored to have known for many years, Chief Billy Hayes and Chief Doug Cline; the program explored leading fire service issues affecting firefighter safety, training, credentialing and education; fireground operational variables related to the continuing changes in building construction, engineered systems and extreme fire behavior,  and the emerging need for “Tactical Patience” as I’ve been exploring the relationships towards the need for tactical enhancements to our current fire suppression theory and firefighting models.

Conversations expanded on the NFFF/Everyone Goes Home Campaign and programs, the newest EGH initiatives on Behavioral Health and the successes achieved through the Courage to be Safe Programs and the Advocacy Program.

Both our guests provided cutting edge perspectives and commentary on the key issues that the fire service needs to have on their radar screen and the need for emerging and practicing fire officers and commanders to continually strive to increase skill sets and maintain a pulse on the leading issues affecting the fire service and apply emerging research  and studies to increase operational capabilities, improve performance and enhance and promote firefighter safety and survival and operational integrity.

Although technical difficulties from the live feed coming from the Inner Harbor in Baltimore at the Firehouse Expo, precluded the ability to have the call-in segments of the program to work, the 120 minute program gave the listeners a wealth of information to talk over in the firehouse, at the kitchen table or in the apparatus bays.

The program is a Buildingsonfire.com Series and a Fire Fighter Netcast.com  production, produced by John Mitchell and Rhett Fleitz.  The live program segment will be edited and available for iTunes download soon. You can check out the other programming and shows produced by Fire Fighter Netcast.com HERE. Stay tuned for announcements on the next program date for Taking it to the Streets coming to you live from the IAFC Fire Rescue International Conference in Chicago in August.  

Taking it to the Streets; Advancing Fire Fighter Safety and Operational Integrity for the Fire Service through provocative insights and dynamic discussions dedicated to the Art and Science of Firefighting and the Traditions of the Fire Service. 

  • Firefighter Netcast.com HERE
  • Taking it to the Streets, HERE, HERE
  • “What’s on your Radar Screen?” July 21, 2010 Program, HERE
  • “What’s on your Radar Screen?” post on Commandsafety.com, HERE

 

Transmitting the Box for an Alarm of Fire…Taking it to the Streets

No comments

Taking it to the Streets

Premiering Wednesday July 21st  9:00pm ET

Live on Firefighter Netcast.com

Premiering “What’s on YOUR Radar Screen”?

Check out what’s on of off your radar screen on CommandSafety.com

If you’ve never listened to a FirefighterNetcast, visit the site now, sign up for a new user account for BlogTalkRadio, and be prepared to join in the conversation Wednesday night.

Listen in via the Internet, listen and/or participate by calling in, and join in the live chat that takes place amongst listeners while the show is going on. In case you miss the live show, you can even download the recording after the fact on FirefighterNetcast and iTunes too. It’s free, it’s fun and it’s easy.

Taking it to the Streets is a Buildingsonfire.com Series and Fire Fighter Netcast.com Production

Check out Buildingsonfire on Facebook and Twitter

Premiering “What’s on YOUR Radar Screen”? on Fire Fighter Netcast.com

No comments

Taking it to the Streets

Premiering Wednesday July 21st  9:00pm ET

Live on Firefighter Netcast.com

Premiering “What’s on YOUR Radar Screen”?

Check out what’s on of off your radar screen on CommandSafety.com

If you’ve never listened to a FirefighterNetcast, visit the site now, sign up for a new user account for BlogTalkRadio, and be prepared to join in the conversation Wednesday night.

Listen in via the Internet, listen and/or participate by calling in, and join in the live chat that takes place amongst listeners while the show is going on. In case you miss the live show, you can even download the recording after the fact on FirefighterNetcast and iTunes too. It’s free, it’s fun and it’s easy.

Taking it to the Streets is a Buildingsonfire.com Series and Fire Fighter Netcast.com Production

Check out Buildingsonfire on Facebook and Twitter

Check out FireDaily and The FireCritic

Newest NIOSH Alert: Preventing Deaths and Injuries of Fire Fighters at Structure Fires

2 comments

NIOSH released it’s latest Alert on Firefighter Risk Reduction. Fire fighters are often killed or injured when fighting fires in abandoned, vacant, and unoccupied structures. These structures pose additional and sometimes unique risks due to the potential for fire fighters to encounter unexpected and unsafe building conditions such as dilapidation, decay, damage from previous fires and vandals, and other factors such as uncertain occupancy status. Risk management principles must be applied at all structure fires to ensure the appropriate strategy and tactics are used based on the fireground conditions encountered.

Fire fighters should take the following steps to minimize their risk of death and injury while fighting structure fires:

  • Report conditions and hazards encountered to your officer, incident commander, or incident safety officers
  • Recognize that maintaining your safety is a shared responsibility
  • Comply with your department’s standard operating procedures (SOPs) / standard operating guidelines (SOGs) and safety rules.
  • Be constantly aware of your surroundings and changing conditions.

Fire departments (chief officers, company officers and policy makers) should take the following steps to protect fire fighters:

  • Develop and enforce risk management plans, policies, and standard operating procedures and guide-lines (SOPs/SOGs) for risk management.
  • Train incident commanders, incident safety officers, and fire fighters in the fire department risk management plans and SOPs/SOGs for risk management.

Develop and implement fire department policies and SOPs/SOGs for emergency response and fire-fighting activities in and around abandoned, vacant, or unoccupied structures.

  • A thorough size-up and risk analysis should be performed before conducting operations in any burning structure.
  • Fire-fighting operations should be limited to defensive (exterior) strategy if the structure is judged to be unsafe and in any situation where the risks to fire fighter safety are excessive.
  • Offensive (interior attack) operations should only be considered when sufficient resources are on scene to conduct offensive operations with a reasonable degree of safety, including the ability to perform essential support functions (i.e., water supply, ventilation, lighting, utility control, accountability, rapid intervention teams).
  • Additional size-ups and risk analyses should be performed before changing strategies, including any decision to conduct interior overhaul operations following a defensive fire attack.
  • Have adequate resources available on scene to per-form rapid intervention team (RIT) duties anytime personnel are operating at any structure fire.
  • Inspect and preplan buildings within your jurisdiction. Note the type of construction, materials used, presence of trusses and/or lightweight construction in the roof and floor, type of occupancy, fuel load, exit routes, and other distinguishing characteristics.
  • Enter preplan information into the dispatch computer so that when a fire is reported at a preplanned location, the critical information is provided to all responding units. Adopt and enforce a standard system of marking dangerous abandoned, derelict, and vacant buildings, based on a prefire assessment of their structural conditions and other risk factors, in cooperation with municipal agencies and local authorities such as local housing authorities.
  • Train fire fighters and officers to recognize the marking system and incorporate the information into their size-up considerations. Additionally, local authorities should ensure programs are in place that provide for the demolition and removal of structures deemed unsafe by code enforcement.
    • Make sure that the incident commander conducts an initial size-up of critical fireground factors before beginning fire fighting efforts and continuously re-views and reevaluates these factors during all fire-ground operations. A 360-degree size-up should be conducted for all abandoned, vacant, or unoccupied structures.
    • Ensure those in charge of fire incidents (e.g., incident commanders, chief officers, safety officers) are fully trained to fulfill their responsibilities and obligations in the execution of their duties.
    • Educate the public on the need to have home fire drills and designated meeting places in the event of an emergency. The location of designated meeting
    • places should be communicated to the fire department as a way to help confirm and verify building occupancy status.

Incident commanders (IC) and incident safety officers (ISO) should do the following:

  • The IC should conduct an initial size-up of each incident weighing critical fireground factors (i.e., occupancy status; occupant survivability and rescue potential; vacant building markings or indicators; size, construction and use of the building; age and condition of the building; and the location, size, and extent of the fire in the building) against the department’s risk management profile to determine the initial incident strategy (offensive or defensive). The IC should develop an incident action plan before beginning firefighting efforts and continually review and reevaluate the factors and the risk management plan throughout the operation.
  • The IC should use appropriate risk management criteria to decide whether an offensive or defensive strategy should be employed to attack a fire. The IC should attempt to determine whether the building is occupied or not. Signs to look for include vehicles in garage, driveway, or parked nearby; people at windows of apartment or office buildings calling for help indicates the possibility of other occupants as well; time of day; type of occupancy; and reports from occupants who have escaped the burning structure. Reports from neighbors and bystanders may also provide valuable information.
  • The IC should consider the number of fire fighters, the amount and type of apparatus and equipment available, and the stage of the fire when determining the type of fire attack.
  • Follow departmental policies (risk management plans, SOPs/SOGs) for risk management.
  • Establish, clearly mark, and monitor an exterior collapse zone at structure fires where there is a risk of collapse.
  • Use effective and universal evacuation signals when command personnel determine that all fire fighters should be evacuated from a burning building, as well as during the initiation of defensive operations and during overhaul and salvage operations.

NIOSH Summary HERE

NIOSH Publication No. 2010-153:

NIOSH Alert: Preventing Deaths and Injuries of Fire Fighters using Risk Management Principles at Structure Fires, HERE

Taking it to The Streets on FireFighter Netcast.com

No comments

 

 

Taking it to the Streets

With Christopher Naum

A New Monthly Radio Talkshow on  FireFighter Netcast.com  Premiering on Wednesday July 21 at 9pm ET

A Buildingsonfire.com Series and FireFighter Netcast.com Production 

Advancing FireFighter Safety and Operational Intergrity for the Fire Service through provocative insights and dynamic discussions dedicated to the Art and Science of Firefighting and the Traditions of the Fire Service. 

Watch for More Taking it to the Streets  Annoucements over the next seven days here on CommandSafety.com, TheCompanyOfficer.com and on Firefighter Netcast.com 

Programming

Ten Minutes in the Street

  • Presenting an informational recap and discussion on leading topcs, events and issues from the past 30 days.

 Feature Segments Program will have one (1) selected segment based upon topic and guest 

 Buildingsonfire

  • Addressing today’s topical issues within the areas of Firefighting, Building Construction, Dynamic Risk Assessment, and Command & Tactical Safety
    • Open interative discussions and call-in
  • Street Stories
    • Presenting first-hand accounts and insights on an event, response or operation with a featured guest
    • Open interative discussions and call-in
  • Smoke Showin’
    • Featured Guest Interviews and discussions focusing on the NFFF Firefighter Life Safety Initiatives and Everyone Goes Home Campaign 
    • Open interative discussions and call-in

HRE History Repeating Events  

  • Discussion on recent History Repeating Events, LODD, NIOSH Reports or other
  • Open interative discussions and call-in

 A View from the Street

  • Closing Commentary on timely and relevant issues affecting the Fire Service

What’s On Your Radar Screen?

11 comments

BuildingsonFire 2010; Building Construction, Command Risk Management and Operational Safety

Major Influencing Fire Service Reports, Issues or Focus that should be on Your Radar Screen

The following list is but a modest cross section of pertinent information or focus areas today’s Firefighter, Company or Command Officer MUST be knowledgeable in, have insights and proficiency based technical skills to function with a level of competencies demanded in  today’s  fire service.

If these are not on your radar screen or you haven’t got a blip of a clue what they’re about; then you are derelict and not doing your job- and the end result could be a less than desirable outcome on the fireground; it’s that simple, it’s that direct.

Have you read these reports, understand the issues & influences, increased your knowledge, skills and abilities in any gap areas or taken the time to research the cutting edge issues affecting today’s fire service?

The City of Charleston Sofa Super Store LODD-Routley Fire Report

Read the report; understand the incident, the building performance, the fire behavior and the operation process deployed. Gain the insights from the overall apparent and contributing causes identified and presented and assess how these relate to your fire service perspective and department’s culture and performance today.

  • City of Charleston Post Incident Assessment and Review Team Phase I Report, HERE
  • Routley Final Phase II Report HERE
  • NIOSH Investigative Report, HERE
  • NIOSH REPORT SUMMARY
  • NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should:
  • develop, implement and enforce written standard operating procedures (SOPs) for an occupational safety and health program in accordance with NFPA 1500
  • develop, implement, and enforce a written Incident Management System to be followed at all emergency incident operations
  • develop, implement, and enforce written SOPs that identify incident management training standards and requirements for members expected to serve in command roles
  • ensure that the Incident Commander is clearly identified as the only individual with overall authority and responsibility for management of all activities at an incident
  • ensure that the Incident Commander conducts an initial size-up and risk assessment of the incident scene before beginning interior fire fighting operations
  • train fire fighters to communicate interior conditions to the Incident Commander as soon as possible and to provide regular updates
  • ensure that the Incident Commander establishes a stationary command post, maintains the role of director of fireground operations, and does not become involved in fire-fighting efforts
  • ensure the early implementation of division / group command into the Incident Command System
  • ensure that the Incident Commander continuously evaluates the risk versus gain when determining whether the fire suppression operation will be offensive or defensive
  • ensure that the Incident Commander maintains close accountability for all personnel operating on the fireground
  • ensure that a separate Incident Safety Officer, independent from the Incident Commander, is appointed at each structure fire
  • ensure that crew integrity is maintained during fire suppression operations
  • ensure that a rapid intervention crew (RIC) / rapid intervention team (RIT) is established and available to immediately respond to emergency rescue incidents
  • ensure that adequate numbers of staff are available to immediately respond to emergency incidents
  • ensure that ventilation to release heat and smoke is closely coordinated with interior fire suppression operations
  • conduct pre-incident planning inspections of buildings within their jurisdictions to facilitate development of safe fireground strategies and tactics
  • consider establishing and enforcing standardized resource deployment approaches and utilize dispatch entities to move resources to fill service gaps
  • develop and coordinate pre-incident planning protocols with mutual aid departments
  • ensure that any offensive attack is conducted using adequate fire streams based on characteristics of the structure and fuel load present
  • ensure that an adequate water supply is established and maintained
  • consider using exit locators such as high intensity floodlights or flashing strobe lights to guide lost or disoriented fire fighters to the exit
  • ensure that Mayday transmissions are received and prioritized by the Incident Commander
  • train fire fighters on actions to take if they become trapped or disoriented inside a burning structure
  • ensure that all fire fighters and line officers receive fundamental and annual refresher training according to NFPA 1001 and NFPA 1021
  • implement joint training on response protocols with mutual aid departments
  • ensure apparatus operators are properly trained and familiar with their apparatus
  • protect stretched hose lines from vehicular traffic and work with law enforcement or other appropriate agencies to provide traffic control
  • ensure that fire fighters wear a full array of turnout clothing and personal protective equipment appropriate for the assigned task while participating in fire suppression and overhaul activities
  • ensure that fire fighters are trained in air management techniques to ensure they receive the maximum benefit from their self-contained breathing apparatus (SCBA)
  • develop, implement and enforce written SOPS to ensure that SCBA cylinders are fully charged and ready for use
  • use thermal imaging cameras (TICs) during the initial size-up and search phases of a fire
  • develop, implement and enforce written SOPs and provide fire fighters with training on the hazards of truss construction
  • establish a system to facilitate the reporting of unsafe conditions or code violations to the appropriate authorities
  • ensure that fire fighters and emergency responders are provided with effective incident rehabilitation
  • provide fire fighters with station / work uniforms (e.g., pants and shirts) that are compliant with NFPA 1975 and ensure the use and proper care of these garments.

Additionally, federal and state occupational safety and health administrations should:

  • consider developing additional regulations to improve the safety of fire fighters, including adopting National Fire Protection Association (NFPA) consensus standards.

Additionally, manufacturers, equipment designers, and researchers should:

  • continue to develop and refine durable, easy-to-use radio systems to enhance verbal and radio communication in conjunction with properly worn SCBA
  • conduct research into refining existing and developing new technology to track the movement of fire fighters inside structures.

Additionally, code setting organizations and municipalities should:

  • require the use of sprinkler systems in commercial structures, especially ones having high fuel loads and other unique life-safety hazards, and establish retroactive requirements for the installation of fire sprinkler systems when additions to commercial buildings increase the fire and life safety hazards
  • require the use of automatic ventilation systems in large commercial structures, especially ones having high fuel loads and other unique life-safety hazards.

Additionally, municipalities and local authorities having jurisdiction should:

  • coordinate the collection of building information and the sharing of information between building authorities and fire departments
  • consider establishing one central dispatch center to coordinate and communicate activities involving units from multiple jurisdictions
  • ensure that fire departments responding to mutual aid incidents are equipped with mobile and portable communications equipment that are capable of handling the volume of radio traffic and allow communications among all responding companies within their jurisdiction.

Everyone Goes Home Campaign

  • Everyone Goes Home® is a national program by the National Fallen Firefighters Foundation to prevent line-of-duty deaths and injuries. In March 2004, a Firefighter Life Safety Summit was held to address the need for change within the fire service. At this summit, the 16 Firefighter Life Safety Initiatives were created and a program was born to ensure that Everyone Goes Home®.
  • Recognizing the need to do more to prevent line-of-duty deaths and injuries, the National Fallen Firefighters Foundation has launched a national initiative to bring prevention to the forefront.
  • In March 2004, the Firefighter Life Safety Summit was held in Tampa, Florida to address the need for change within the fire and emergency services. Through this meeting, 16 Life Safety Initiatives were produced to ensure that Everyone Goes Home®.
  • The first major action was to sponsor a national gathering of fire and emergency services leaders. The National Fallen Firefighters Foundation will play a major role in helping the U.S. Fire Administration meet its stated goal to reduce the number of preventable firefighter fatalities. The Foundation sees fire service adoption of the summit’s initiatives as a vital step in meeting this goal.
  • The Courage to Be Safe® On-Line Program , HERE
  • Media CenterUsing variations of the Courage to Be Safe ®…So Everyone Goes Home® field program, along with material from the Firefighter Life Safety Initiatives Resource Kit we will develop and deploy a new online learning segment each month. These online learning segments will allow you to expand upon your personal and professional development when you want and how you want. Watch them by yourself or integrate them into your organizational training programs. Remember, that safety results from constant training and putting those skills to work everyday, on every call – SO EVERYONE GOES HOME. HERE
  • The Firefighter Life Safety Initiatives Advocates Program will play a key role in helping to bring about awareness of the Initiatives and act as a conduit for resources to enable departments to implement and advocate them. HERE
  • The 16 Fire Fighter Life Safety Initiatives
    1. Define and advocate the need for a cultural change within the fire service relating to safety; incorporating leadership, management, supervision, accountability and personal responsibility.
    2. Enhance the personal and organizational accountability for health and safety throughout the fire service.
    3. Focus greater attention on the integration of risk management with incident management at all levels, including strategic, tactical, and planning responsibilities.
    4. All firefighters must be empowered to stop unsafe practices.
    5. Develop and implement national standards for training, qualifications, and certification (including regular recertification) that are equally applicable to all firefighters based on the duties they are expected to perform.
    6. Develop and implement national medical and physical fitness standards that are equally applicable to all firefighters, based on the duties they are expected to perform.
    7. Create a national research agenda and data collection system that relates to the initiatives.
    8. Utilize available technology wherever it can produce higher levels of health and safety.
    9. Thoroughly investigate all firefighter fatalities, injuries, and near misses.
    10. Grant programs should support the implementation of safe practices and/or mandate safe practices as an eligibility requirement.
    11. National standards for emergency response policies and procedures should be developed and championed.
    12. National protocols for response to violent incidents should be developed and championed.
    13. Firefighters and their families must have access to counseling and psychological support.
    14. Public education must receive more resources and be championed as a critical fire and life safety program.
    15. Advocacy must be strengthened for the enforcement of codes and the installation of home fire sprinklers.
    16. Safety must be a primary consideration in the design of apparatus and equipment.

NIST Wind Driven Fire Study

  • Smoke and heat spreading through the corridors and the stairs of a building during a fire can limit building occupants’ ability to escape and can limit fire fighters’ ability to rescue them.  Changes in the building’s ventilation or presence of an external wind can increase the energy release of the fire.  This can also increase the spread of fire gases through the building.  In some cases, such as the Cook County Administration Building fire in October 2003, the fire gas flow, into the corridors and the stairway prevented fire fighters from suppressing the fire from inside the structure.  This fire resulted in 6 building occupant fatalities and fire fighter injuries in the stairway.  The Fire Department of New York City has experienced many wind driven fire incidents which have resulted in fire fighter fatalities and injuries, as have a number of other incidents nationally that have resulted in increased research into this operational and tactical challenge.
  • What tactics or tools are appropriate for use with a wind driven fire and how should the tactics or tools be implemented?  Positive Pressure Ventilation (PPV) is being used by fire departments on smaller structures, such as single family homes, to control the fire flow by introducing pressure from the front door and venting the house through a strategic exit opening.  If done correctly, this tactic can remove significant amounts of heat and smoke from the structure, thus improving the fire fighters’ working environment and improving the chances of survival for the building occupants.  NIST has completed several studies which have a two fold impact: 1) providing guidance on the safe use of PPV and 2) characterizing and validating the modeling of PPV with a computational fluid dynamics (CFD) computer model, so that the model can be used as a training tool for the fire service.
  • This project extends previous work for ventilation under wind driven conditions.  There are many questions regarding wind driven fires.  For example can these PPV fans be used successfully under wind driven fire conditions in large structures?  Large structures, such as high rise buildings, provide additional challenges to fire fighter and building occupant safety: increased travel distance (exposure time), more complicated egress path, and potentially larger fires.  In 2002 there were 7,300 reported fires in high rise structures.
  • Other tactics incorporating devices, such as wind control devices (WCD) to control the ventilation conditions or the use of a “high rise” nozzle from the floor below the fire floor have been tried by the fire service under “real fire” conditions with varying levels of success.
  • A comprehensive free DVD set from the NIST includes a presentation video that explains PPV, examines the results of NIST’s PPV research, and closes with a focus on the use of PPV tactics in high-rise buildings.  All of the NIST PPV reports referenced in the presentation are included on Disc 1 of the set.  All of the videos from the high-rise fire experiments are also provided with a user-friendly, graphic menu that can be used on a PC or a DVD player.  NIST, with support from USFA, DHS, and fire departments across the country, has taken engineering principles and applied them to fire service PPV tactics in order to improve fire fighter safety
  • NIST References HERE and HERE

NIST Fire Fighting Tactics Under Wind Driven Conditions: Laboratory Experiments

  • A series of experiments was conducted in our Large Fire Laboratory to examine the impact of wind control curtains and externally applied hose streams on a wind driven fire.  The results from these experiments will allow us to better understand the fire dynamics within a structure and provide guidance as to the important measurements needed in the future experiments in a high-rise on Governor’s Island in New York City.
  • Fire Fighting Tactics Under Wind Driven Conditions Report, HERE
  • Reference Data HERE

NIST Firefighter Safety and Deployment Study; Report on Residential Fireground Field Experiments

  • The NIST Firefighter Safety and Deployment Study; Titled- Report on Residential Fireground Field Experiments was recently released to the public providing . A copy of the report is attached.
  • Report Abstract:
  • Service expectations placed on the fire service, including Emergency Medical Services (EMS), response to natural disasters, hazardous materials incidents, and acts of terrorism, have steadily increased. However, local decision-makers are challenged to balance these community service expectations with finite resources without a solid technical foundation for evaluating the impact of staffing and deployment decisions on the safety of the public and firefighters. For the first time, this study investigates the effect of varying crew size, first apparatus arrival time, and response time on firefighter safety, overall task completion, and interior residential tenability using realistic residential fires.
  • This study is also unique because of the array of stakeholders and the caliber of technical experts involved. Additionally, the structure used in the field experiments included customized instrumentation; all related industry standards were followed; and robust research methods were used. The results and conclusions will directly inform the NPFA 1710 Technical Committee, who is responsible for developing consensus industry deployment standards.
  • This report presents the results of more than 60 laboratory and residential fireground experiments designed to quantify the effects of various fire department deployment configurations on the most common type of fire—a low hazard residential structure fire. For the fireground experiments, a 2,000 sq ft (186 m2), two-story residential structure was designed and built at the Montgomery County Public Safety Training Academy in Rockville, MD. Fire crews from Montgomery County, MD and Fairfax County.
  • Report results quantify the effectiveness of crew size, first-due engine arrival time, and apparatus arrival stagger on the duration and time to completion of the key 22 fireground tasks and the effect on occupant and firefighter safety.
  • The report is also available for download at the NIST, HERE
  • Synopsis HERE

USFA/NIST Trends in Firefighter Fatalities Due to Structural Collapse, 1979-2002

  • Between the years 1979 and 2002 there were over 180 firefighter fatalities due to structural collapse, not including those firefighters lost in 2001 in the collapse of the World Trade Center Towers. Structural collapse is an insidious problem within the fire fighting community. It often occurs without warning and can easily cause multiple fatalities.
  • As part of a larger research program to help reduce firefighter injuries and fatalities the U.S. Fire Administration (USFA) funded the National Institute of Standards and Technology (NIST) to examine records and determine if there were any trends and/or patterns that could be detected in firefighter fatalities due to structural collapse. If so, these trends could be brought immediately to the attention of training officers and incident commanders and investigated further to determine probable causes.
  • Report: Trends in Firefighter Fatalities Due to Structural Collapse1979-2002
  • Report: Early Warning Capabilities for Firefighters:Testing of Collapse Prediction Technologies

UL Fire Academy CBT

  • UL Structural Stability of Engineered Lumber in Fire Conditions
  • Base on the UL research and
  • This two-hour presentation summarizes a research study on the hazards posed to firefighters by the use of lightweight construction and engineered lumber in floor and roof designs. This free on-line computer based presentation will allow fire professionals to better interpret fire hazards and assess risk for life safety of building occupants and firefighters.
  • This online firefighter training course is the result of a research partnership among UL, the Chicago Fire Department, IAFC, and Michigan State University, funded in part by the U.S. Department of Homeland Security. This self-guided course, which focuses on the structural stability of engineered lumber under fire conditions, is targeted toward the 1.1 million fire service personnel in the United States and Canada. The knowledge developed and shared in this course is critically important to firefighter and civilian safety.
  • This two-hour presentation summarizes a research study on the hazards posed to firefighters by the use of lightweight construction and engineered lumber in floor and roof designs. This free on-line computer based presentation will allow fire professionals to better interpret fire hazards and assess risk for life safety of building occupants and firefighters.
  • Program Objectives:
  • Provide brief history of events leading up to DHS Grant tests
  • Identify the fire test hypothesis, parameters, and steps completed in the testing process
  • Compare tests results (legacy vs. modern construction)
  • Communicate learnings from our partners representing the fire service
  • Discuss code recommendations
  • UL University on-line Program HERE

USFA/NIST Trends in Firefighter Fatalities Due to Structural Collapse, 1979-2002

  • Between the years 1979 and 2002 there were over 180 firefighter fatalities due to structural collapse, not including those firefighters lost in 2001 in the collapse of the World Trade Center Towers. Structural collapse is an insidious problem within the fire fighting community. It often occurs without warning and can easily cause multiple fatalities.
  • As part of a larger research program to help reduce firefighter injuries and fatalities the U.S. Fire Administration (USFA) funded the National Institute of Standards and Technology (NIST) to examine records and determine if there were any trends and/or patterns that could be detected in firefighter fatalities due to structural collapse. If so, these trends could be brought immediately to the attention of training officers and incident commanders and investigated further to determine probable causes.
  • Report: Trends in Firefighter Fatalities Due to Structural Collapse1979-2002
  • Report: Early Warning Capabilities for Firefighters:Testing of Collapse Prediction Technologies

NIOSH LODD Reports

  • Each year an average of 105 fire fighters die in the line of duty. To address this continuing national occupational fatality problem, NIOSH conducts independent investigations of fire fighter line of duty deaths. The dedicated web page provides access to NIOSH investigation reports and other fire fighter safety resources.
  • NIOSH Web Page HERE
  • Through the Fire Fighter Fatality Investigation and Prevention Program, NIOSH conducts investigations of fire fighter line-of-duty deaths to formulate recommendations for preventing future deaths and injuries. The program does not seek to determine fault or place blame on fire departments or individual fire fighters, but to learn from these tragic events and prevent future similar events.
  • Fire Fighter Fatality Investigation Reports, HERE

NIOSH Alert: Preventing Deaths and Injuries of Fire Fighters using Risk Management Principles at Structure Fires

  • Fire fighters are often killed or injured when fighting fires in abandoned, vacant, and unoccupied structures.
  • These structures pose additional and sometimes unique risks due to the potential for fire fighters to encounter unexpected and unsafe building conditions such as dilapidation, decay, damage from previous fires and vandals, and other factors such as uncertain occupancy status. Risk management principles must be applied at all structure fires to ensure the appropriate strategy and tactics are used based on the fireground conditions encountered.
  • Report HERE

NIOSH Report; Preventing Deaths and Injuries of Fire Fighters Working Above Fire Damaged Floors

  • Fire fighters are at risk of falling through fire-damaged floors. Fire burning underneath floors can significantly degrade the floor system with little indication to fire fighters working above.
  • Floors can fail within minutes of fire exposure, and new construction technology such as engineered wood floor joists may fail sooner than traditional construction methods.
  • NIOSH recommends that fire fighters use extreme caution when entering any structure that may have fire burning beneath the floor.
  • Report HERE

NIOSH ALERT: Preventing Injuries and Deaths of Fire Fighters due to Truss System Failures

  • Fire fighters may be injured and killed when fire-damaged roof and floor truss systems collapse, sometimes without warning.
  • The National Institute for Occupational Safety and Health (NIOSH) requests assistance in preventing injuries and deaths of fire fighters due to roof and floor truss collapse during fire-fighting operations. Roof and floor truss system collapses in buildings that are on fire cannot be predicted and may occur without warning.
  • NIOSH recommends that fire departments review their occupational safety programs and standard operating procedures to ensure they include safe work practices in and around structures that contain trusses. Building owners should follow proper building codes and consider posting building construction information outside a building to advise fire fighters of the conditions they may encounter.
  • ALERT Report HERE

National Near Miss Reporting System (NNMRS) Operating Experience

  • The National Fire Fighter Near-Miss Reporting System is a voluntary, confidential, non-punitive and secure reporting system with the goal of improving fire fighter safety.
  • Submitted reports will be reviewed by fire service professionals. Identifying descriptions are removed to protect your identity. The report is then posted on this web site for other fire fighters to use as a learning tool.
  • National Fire Fighter Near-Miss Reporting System Web Site, HERE
  • Search Reports, HERE
  • Resources, HERE

USFA Incident Reports (Stop History Repeating Events-HRE)

  • USFA provides information resources in many formats, including books, pamphlets and DVD’s, free of charge.
  • The U.S. Fire Administration develops reports on selected major fires throughout the country. The fires usually involve multiple deaths or a large loss of property. But the primary criterion for deciding to do a report is whether it will result in significant “lessons learned.” In some cases these lessons bring to light new knowledge about fire–the effect of building construction or contents, human behavior in fire, etc. In other cases, the lessons are not new but are serious enough to highlight once again, with yet another fire tragedy report. In some cases, special reports are devel­oped to discuss events, drills, or new technologies which are of interest to the fire service.
  • The reports are sent to fire magazines and are distributed at National and Regional fire meetings. The International Association of Fire Chiefs assists the USFA in disseminating the findings throughout the fire service. On a continuing basis the reports are available on request from the USFA; announce­ments of their availability are published widely in fire journals and newsletters
  • This body of work provides detailed information on the nature of the fire problem for policymakers who must decide on allocations of resources between fire and other pressing problems, and within the fire service to improve codes and code enforcement, training, public fire education, building technology, and other related areas.
  • The Fire Administration, which has no regulatory authority, sends an experienced fire investigator into a community after a major incident only after having conferred with the local fire authorities to insure that the assistance and presence of the USFA would be supportive and would in no way interfere with any review of the incident they are themselves conducting. The intent is not to arrive during the event or even immediately after, but rather after the dust settles, so that a complete and objective review of all the important aspects of the incident can be made
  • Technical Reports and On-line Publications, HERE

Prince William County (VA) Fire Rescue Kyle Wilson LODD Report

  • The Prince William County (VA) Department of Fire and Rescue published a comprehensive line of duty death report for Technician I Kyle R. Wilson on Saturday, January 26, 2008. Technician I Wilson was the first line of duty death in the Department’s 41-year history. The Department is sharing the LODD Investigative Report to honor Kyle, and in an effort to reduce and prevent firefighter line of duty deaths at the local, region, state, and national levels.
  • Technician Kyle Robert Wilson was 24-years old and was born in Olney, Maryland. He grew up in Prince William County and graduated from Hylton High School and George Mason University. He was an avid baseball and softball player. Technician Wilson joined the Prince William County Department of Fire and Rescue on January 23, 2006. Technician Kyle Wilson died in the line of duty on April 16, 2007 while performing search and rescue operations at a house fire on Marsh Overlook Drive, located in the Woodbridge area of Prince William County. On that day, Technician Wilson was part of the firefighter staffing on Tower 512 which responded to the house fire that was dispatched at 0603 hours. The Prince William County area was under a high wind advisory as a nor’eastern storm moved through the area. Sustained winds of 25 mph with gusts up to 48 mph were prevalent in the area at the time of the fire dispatch to Marsh Overlook Drive.
  • Initial arriving units reported heavy fire on the exterior of two sides of the single family house and crews suspected that the occupants were still inside the house sleeping because of the early morning hour. A search of the upstairs bedroom commenced for the possible victims. A rapid and catastrophic change of fire and smoke conditions occurred in the interior of the house within minutes of Tower 512’s crew entering the structure.
  • Technician Wilson became trapped and was unable to locate an immediate exit out of the hostile environment. Mayday radio transmissions were made by crews and by Technician Kyle Wilson of the life-threatening situation. Valiant and repeated rescue attempts to locate and remove Technician Wilson were made by the firefighting crews during extreme fire, heat and smoke conditions. Firefighters were forced from the structure as the house began to collapse on them and intense fire, heat and smoke conditions developed. Technician Wilson succumbed to the fire and the cause of death was reported by the medical examiner to be thermal and inhalation injuries.
  • The Department of Fire and Rescue immediately formed a multi-dimensional investigation team following the incident. The investigation team was comprised of five Department of Fire and Rescue uniform personnel and two external members from area fire departments. For eight months, the team thoroughly examined the events that occurred at the Marsh Overlook fire incident and identify the factors involved with the line of duty death of Technician I Kyle Wilson. The resulting report represents thousands of hours of effort to analyze fire and rescue operations and is a factual representation of the events that occurred. The report also provides a frame work for organizational level improvements.
  • The major factors in the line of duty death of Technician I Wilson were determined to be:
    • The initial arriving fire suppression force size.
    • The size up of fire development and spread.
    • The impact of high winds on fire development and spread.
    • The large structure size and lightweight construction and materials.
    • The rapid intervention and firefighter rescue efforts.
    • The incident control and management.
    • The Marsh Overlook fire incident was an immense fire fueled by extremely flammable building material products and a vicious wind. It was an environment where information gathering and decision making had to be performed in the time measurement of seconds. During the chain of events that occurred and under severe circumstances, fire and rescue personnel performed at exceptional levels.
  • During the repeated attempts to reach and rescue Technician I Wilson, personnel displayed heroic efforts and jeopardized their own safety. The Department will never forget the sacrifice that Technician Wilson made in an attempt to ensure others were safe. By sharing the knowledge gained from this very tragic and painful incident, the Department will ensure his sacrifice was not in vain and hope that other fire and rescue departments can avoid another similar occurrence.
  • Resources and Report

Loudoun County (VA) Fire Rescue  Significant Near Miss Event Report

  • On May 25, 2008, fire and rescue personnel from Loudoun County responded to a structure fire at 43238 Meadowood Court in Leesburg, Virginia. During the course of the incident, seven responders were injured. Of those injured, four firefighters received significant burn injuries, two firefighters sustained orthopedic injuries, and one EMS provider was treated for minor respiratory distress. To date, five of the injured personnel have returned to duty. Two firefighters continue to recover from their injuries, including one who was severely burned.
  • Given the severity of the injuries and magnitude of the event, an independent Investigative Team was assembled to review the incident. The Team was comprised of four Loudoun County personnel, three external members from area fire departments, and two resource/support personnel. The Team was tasked with reviewing “the events leading up to the incident, the incident operation(s), the firefighter MAYDAY(s), and incident mitigation.”
  • For three months, the Team thoroughly examined the events surrounding the Meadowood Court fire incident and identified the factors associated with the injury of personnel.
  • The Report contains the results of the Investigative Team’s comprehensive review and analysis.
  • Fact Sheet, HERE
  • SIGNIFICANT INJURY INVESTIGATIVE REPORT 43238 MEADOWOOD COURT MAY 25, 2008 Report HERE

Worcester (MA) Fire Cold Storage Fire LODD Report; Abandoned Cold Storage Warehouse Multi-Firefighter Fatality Fire 1999, Worcester, Massachusetts

  • A technical review of the 1999 Worcester, MA fire that claimed six firefighters concludes that abandoned buildings are a serious threat to firefighters and fire departments must make a concerted effort to use technology to maintain data on buildings in their response districts.
  • On Friday, December 3, 1999, at 1813 hours, the Worcester, Massachusetts Fire Department dis­patched Box 1438 for 266 Franklin Street, the Worcester Cold Storage and Warehouse Co. A motor­ist had spotted smoke coming from the roof while driving on an adjacent elevated highway. The original building was constructed in 1906, contained another 43,000 square feet. Both were 6 stories above grade. The building was known to be abandoned for over 10 years.
  • Eleven minutes into the fire, the owner of the abutting Kenmore Diner advised fire operations of two homeless people who might be living in the warehouse. The rescue company, having divided into two crews, started a building search. Some 22 minutes later the rescue crew searching down from the roof became lost in the vast dark spaces of the fifth floor. They were running low on air and called for help. Interior conditions were deteriorating rapidly despite efforts to extinguish the blaze, and visibility was nearly lost on the upper floors. Investigators have placed these two firefighters over 150 feet from the only available exit.
  • An extensive search was conducted by Worcester Fire crews through the third and fourth alarms. Suppression efforts continued to be ineffective against huge volumes of petroleum based materials, and ultimately two more crews became disoriented on the upper floors and were unable to escape. When the evacuation order was given one hour and forty-five minutes into the event, five firefighters and one officer were missing. None survived.
  • A subsequent exterior attack was set up and lasted for over 20 hours utilizing aerial pieces and del­uge guns from Worcester and neighboring departments. Task force groups from across the State of Massachusetts responded to initial suppression and subsequent recovery efforts. During this time, the four upper floors collapsed onto the second which became known as “the deck”. Over 6 million gallons of water were used during the suppression efforts. According to NFPA records, this is the first loss of six firefighters in a structure fire where neither building collapse nor an explosion was a contributing factor to the fatalities.
  • USFA Report HERE

Colerain Township (OH) Fire and EMS Department Final Report Investigation Analysis of the Squirrels Nest Lane Firefighter Line of Duty Deaths

  • The Colerain Township (OH) Fire and EMS Department under the leadership of Director and Chief G. Bruce Smith recently released its final report Investigation Analysis of the Squirrels nest Lane Firefighter Line of Duty Deaths related to the April 4, 2008 Double Line of Duty Death of a Captain and Firefighter.  This investigative analysis and report, although specific to the events and conditions encountered during the conduct of operation at the residential occupancy at 5708 Squirrels nest Lane has pertinent and relevant insights, recommendations and factors that all Fire Service personnel, regardless of rank should read.
  • Incident Overview, HERE
  • NIOSH Report, HERE
  • Investigative Report, HERE

Field Trips

  • Take a good look at the structures, occupancies and  buildings in you first, second and third due areas, look around your community and jurisdiction as well as your mutual aid and greater alarm response box areas.
  • Have you stopped for a minute today and taken a good look around? Whether you’re sitting in the front seat at the stop light of an intersection or as you’re peering out the side cab window coming back from an alarm or while running errands in your POV; have you taken a good look around? As the Springsteen song goes; “this is your town”.
  • There’s a lot that can be gleaned from your surroundings on any given day. We sometimes take for granted the subtle changes that are happening all around us as we take care of business on our rounds, runs and calls. We tend to focus in on the immediacy of the events that are happening in front of us that demand our attention but fail to take a look around to pick up on information, data and insights that can help us on that next run or down the road in the future.
  • Take a look at the construction that might be going up in your areas. I’m certain you’re paying close attention to what’s happening in your first-due, but what about that third-due area, that neighboring jurisdiction or the mutual-aid area that you occasionally run in to? When you’re on that next EMS run or an investigation of an odor or alarm bells service call, take a few extra minutes to walk through the occupancy. Conduct your own mini company level pre-plan.
  • Look at the layout, features, access and construction features. If you have a chance, verify the structural support systems employed by the building for the floor and roof systems. If you have time, take the company on a quick site visit to that building that’s under construction or the renovations that are again underway in that commercial or business occupancy around the corner from quarters.
  • These continuing challenging economic times places a great deal of influence on what’s being built, how it might be constructed, the manner in which a building may be operational one day, vacant the other and under renovation the next. Sometimes these transformations occur literally overnight.
  • Take a good look around, this is your town…your district, your response area. Know your buildings, understand their performance profiles, and assess the predictability of performance. Remember; Building Knowledge = Firefighter Safety.

Building Construction

I continue to suggest that it’s no longer just brute force and sheer physical determination that define structural fire suppression operations, although any seasoned firefighter and company officer knows that at times; it is what gets the job done under the most arduous and demanding of circumstances. However, from a methodical and disciplined perspective, aggressive firefighting must be redefined and aligned to the built environment and associated with goal oriented tactical operations that are defined by risk assessed and analyzed tasks that are executed under battle plans that promote the best in safety practices and survivability within know hostile structural fire environments.

We can still meet the demands of the job, as firefighters; but do it with Tactical Patience and not at the expense of Command Compression and Tactical Entertainment or worst Operational Recklessness.

The traditional attitudes and beliefs of equating aggressive firefighting operations in all occupancy types coupled with the correlating, established and pragmatic operational strategies and tactics must be adjusted and modified to include intelligent risk assessment, calculated risk analysis, safety and survivability profiling, and strategic operational and tactical value. The demands and requirements of modern firefighting will continue to require the placement of personnel within situations and buildings that carry risk, uncertainty and inherent danger. As a result, risk management must become fluid and integrated with intelligent tactical deployments and operations recognizing the risk problematically and not fatalistically, resulting in safety conscious strategies and tactics. We need to think about the Predicative Strategic Process, refined Tactical Deployment Models integrating intelligent Structural Anatomy and Predictive Occupancy Profiling.

Without understanding the building-occupancy relationships and integrating; construction, occupancies, fire dynamics and fire behavior, risk, analysis, the art and science of firefighting, safety conscious work environment concepts and effective and well-informed incident command management, company level supervision and task level competencies…You are derelict and negligent and “not “everyone may be going home”. Our current generation of buildings, construction and occupancies are not as predictable as past conventional construction; risk assessment, strategies and tactics must adjusted and enhanced to address these new rules of structural fire engagement. There is a profound need to gain building construction knowledge and insights and to change and adjust operating profiles in order to safe guard companies, personnel and team compositions. It’s all about understanding the building-occupancy relationships and the art and science of firefighting, Building Knowledge = Firefighter Safety. Its all about the new formula….Bk=F2S.

Additionally, think about the following

  • Don’t Treat Your Buildings and Occupancies the Same anymore
  • Increase Situational Awareness
  • Increase Your Competencies
  • Know Your Buildings
  • Be aware of Command Compression
  • Implement Tactical Patience
  • Tactical Entertainment
  • Building Knowledge = Firefighter Safety
  • Fire Behavior & Fire Dynamics
  • Situational Awareness
  • Naturalistic Decision Making

More on these and some additional key reports on a future post…..

Eleven Minutes to Mayday; What You Need to Know

12 comments

The Colerain Township (OH) Fire and EMS Department under the leadership of Director and Chief G. Bruce Smith recently released its final report Investigation Analysis of the Squirrels nest Lane Firefighter Line of Duty Deaths related to the April 4, 2008 Double Line of Duty Death of a Captain and Firefighter.  This investigative analysis and report, although specific to the events and conditions encountered during the conduct of operation at the residential occupancy at 5708 Squirrels nest Lane has pertinent and relevant insights, recommendations and factors that all Fire Service personnel, regardless of rank should read.

This is one of those distinctive reports that has influential and critical operational, training and preparedness elements embedded throughout the report. Following my review of the report, having previously read the preliminary report findings, it is apparent there continues to be common threads shared by this and other events and incidents where a single of multiple firefighters have lost their lives due to similarities in the apparent and common cause deficiencies and short comings identified.

All company and command officers should read and comprehend the lessons learned. Then, take these new found insights and see what the gaps are at the personal level (yours or those you supervise) as well as the shift, group, station, battalion, division or department as a whole. If there are gaps, then identify a way to implement timely changes as necessary so there are No History Repeating (HRE) events.

I have provided a comprehensive synopsis of the report for your review. Take the time to read the entire report, make the time to improve where you need to.  

On Friday, April 4, 2008 at 06:13:02 hours, what began as a routine response for Colerain Township Fire and EMS Engine 102 to investigate a fire alarm activation at 5708 Squirrels nest Lane, Colerain Township, Ohio resulted in the deaths of Colerain Township Captain Robin Broxterman and Firefighter Brian Schira.

Upon their arrival at the scene of the two-story wood framed, residential building working fire conditions existed in the basement. The initial attack team consisted of Broxterman, Schira, and one other firefighter. The team advanced a 1¾-inch attack hose line through the interior of the building for fire control.

Even though, they were provided with some of the most technologically advanced protective clothing for structural firefighting and self-contained breathing apparatus, it appeared that Broxterman and Schira were overwhelmed by severe fire conditions in the basement. 

During their attempt to evacuate the building, the main-level family room flooring system in which the two were traveling on collapsed into the basement trapping the firefighters. Eleven minutes elapsed from time of arrival to the catastrophic chain of events.

The investigation of this incident provided a number of findings and recommendations that should be considered by Colerain’s fire department, as well as other fire department organizations. The examination encompassed issues that related to building construction, firefighting tactics, command and control, situational awareness, communications, training, firefighting equipment and the individual responsibility of firefighters of the Colerain Township Department of Fire and Emergency Medical Services (Colerain Fire & EMS). In addition, a segment of the examination included a review of the individual and group affects following such an event, and the measures initiated that attempted to ensure individual, family and organizational wellness.

The following factors were believed to have directly contributed to the deaths of Captain Broxterman and Firefighter Schira:

  • A delayed arrival at the incident scene that allowed the fire to progress significantly;
  • A failure to adhere to fundamental firefighting practices; and
  • A failure to abide by fundamental firefighter self-rescue and survival concepts

 Although the aforementioned factors were believed to have directly contributed to their deaths, they might have been prevented if:

  • Some personnel had not been complacent or apathetic in their initial approach to this incident;
  • Some personnel were in a proper state of mind that made them more observant of their surroundings and indicators;
  • The initial responding units were provided with all pertinent information in a
  • timely manner relative to the incident;
  • Personnel assigned to Engine 102 possessed a comprehensive knowledge of their first-due response area;
  • A 360-degree size-up of the building accompanied by a risk – benefit analysis
  • was conducted by the company officer prior to initiating interior fire suppression operations;
  • Comprehensive standard operating guidelines specifically related to structural
  • firefighting existed within the department;
  • The communications system users (on-scene firefighters and those monitoring the incident) weren’t all vying for limited radio air time;
  • The communications equipment and accessories utilized were more appropriate for the firefighting environment;
  • Certain tactical-level decisions and actions were based on the specific conditions;
  • Personnel had initiated fundamental measures to engage in if they were to become disoriented or trapped inside a burning building; and
  • Issued personal protective equipment was utilized in the correct manner.

 Incident Reported

On Friday, April 4, 2008, at 06:11:23, the Hamilton County Communications Center (HCCC) received notification of an automatic alarm activation (smoke detector and carbon monoxide) at 5708 Squirrels nest Lane (LN).

  • An automatic fire alarm response complement of two engine companies (Engines 102 & 109), one ladder company (Ladder 25), and the Battalion Chief (District 25) were dispatched to investigate at 06:13:02.
  • At 06:13:43, a second notification was received from the female homeowner reporting a fire in the basement of the building.
  • At 06:20:43, a third notification by means of a cellular phone from the female homeowner to HCCC routed through the City of Cincinnati’s Fire and Police Communications Center was received.
  • At 06:22:41, the initial response complement was then upgraded to a building fire, also known as a structure fire response complement to include one additional engine company (Engine 25), one rescue company (Rescue 26), and one basic life support transport unit (Squad 25).

Property and Building Description: The building at 5708 Squirrels nest LN was a single-family residence that set back approximately 450-feet from the street at the end of a private driveway on a heavily wooded lot.

  • The building was two-stories in height, approximately 45-feet wide by 30-feet deep with a finished below-grade (basement) living space and attached two-car garage.
  • For simplicity, the report refers to the living space under the main-level of the building as a basement.
  • From the front (side Alpha), the building was two-stories above grade. The vertical distance between floors was approximately eight-feet. The exterior main entrance was located in the front middle of the building approximately one-foot above grade level.
  • Additional entrances to the first-floor living space were by means of a rear entry door from an upper-level deck area and through the garage area.
  • The interior stairway to the basement was located approximately 15-feet from the front main entry door towards the rear of the building. There were no exposed buildings on the adjacent sides of the fire building.

The building was located approximately 450-feet from the curb and a driveway leading to the front entrance. The nearest fire hydrant was located approximately 500- feet from the front entrance. To provide for uniform identification of locations and operationalforces at the incident scene, the scene was divided geographically into smaller parts, which were designated as sectors. Specific areas of the incident scene were designated as follows:

  • The side of the building that bears the postal address of the location was designated as Side Alpha or front by the Incident Commander;
  • The property sloped downward towards the rear (side Charlie) of the building with an approximate 13-foot elevation difference from side Alpha to Charlie. The
  • Charlie side of the building was three-stories above the rear grade level with the building’s basement floor approximately five-feet above grade level. The exterior entrance to the building’s’ basement area, also known as a walk-out was by means of a stairway that led to a wooden deck on the Charlie side adjacent to the Delta side. A second stairway led to an upper level deck that served the main level of the building.

 

Initial Fire Attack Operation: Upon arrival at the incident address, Engine 102 (E102), assigned four personnel (one captain, one fire apparatus operator [FAO], and two firefighters) entered and proceeded down the driveway deploying a five-inch supply hose line.

  • With their apparatus positioned in front of the building Captain (Capt.) Broxterman radioed, “Moderate smoke showing. E102 will be Squirrelsnest Command.” at 06:24:01.
  • Verification was made by the E102’s FAO through face-to-face communication with the male homeowner that all occupants were out of the building, which was then relayed to Capt. Broxterman.

District 25 (D25) arrived at the scene at 06:26:35 and assumed Command from Capt. Broxterman. Capt. Broxterman, Firefighter (Ffr.) Schira and E102’s Ffr. #2 advanced a 1¾-inch pre-connected hose line through the front main entrance. The fire was determined to be located in the basement of the building.

  • At 06:27:52, Capt. Broxterman radioed, “E102 making entry into the basement, heavy smoke”.
  • At 06:30:35, E109′s captain radioed, “Command from E109, contact 102,have them pull out of the first floor, redeploy to the back. It’s easy access. Conditions are changing at the front door.”
  • At 06:34:48, Engine 25 (E25), the designated Rapid Assistance Team, had just completed their 360-degree size-up around the building, and encountered E102’s Ffr. #2 in front of the building, whom reported that he had lost contact with his crew.
  • During the time period between 06:29:24 and 06:34:48, the investigation committee believed that one or more catastrophic events occurred including a failure of the main-level flooring system near the Beta – Charlie corner of the building.

 Rescue and Recovery Operations

  • At 06:35:34, the Incident Commander (IC) identified a potential Mayday operation, which indicates a life threatening situation to a firefighter.  
  • RAT25 was deployed at 06:36:48. The actual Mayday operation was initiated by the IC at 06:37:41 followed by a request at 06:37:53 to the HCCC for a second alarm complement of firefighting resources.  
  • At 06:42:01, RAT25 entered the basement from the rear of the building. At 07:00:27, E26’s personnel entered through the front main entrance of the building and into the basement by means of the interior stairway.  
  • Both missing firefighters were located in the basement near the Charlie side wall adjacent to the Beta side following a floor collapse. Capt. Broxterman and Ffr. Schira were obviously deceased as a result of their injuries. 

Fire Origin and Cause: Information from the property owners was that the female had smelled an odor in the house. She told her husband, who went to investigate. Neither of them observed any smoke or flames at that time. The husband went to the basement, and located a fire near a cedar wood lined closet used to cultivate orchids in the unfinished utility room. He attempted to extinguish the fire with portable fire extinguishers and pans of water. As the fire alarm activated, the husband had his wife call 9-1-1 to report the fire. The state of Ohio Fire Marshal’s Office Fire and Explosion Investigation Bureau ruled the fire to be accidental in nature. The fire was determined to have originated in the unfinished utility room of the basement level in or near the cedar closet. This area was directly below the family room on the first floor. The probable ignition source for this fire was determined to be at and about a plastic air circulation fan and the associated electrical wiring.

Cause of Deaths

Capt. Broxterman was a 37-year old employee of the Colerain Fire & EMS with approximately 17-years of certified firefighting experience. Capt. Broxterman became trapped in the basement area for a prolonged amount of time following the sudden floor collapse. Capt. Broxterman was found positioned face down over top of Ffr. Schira. The majority of her protective clothing ensemble and equipment were heavily damaged as a result of exposure to heat and direct flame impingement. She was pronounced deceased following her removal from the building. Her body was transported to the Hamilton County Coroner’s Office for autopsy. The Coroner’s report cited the manner of death as “accidental” and the cause of death as “burns and inhalation of smoke and superheated and noxious gases.” Capt. Broxterman sustained burns to 100% of her body surface, which ranged from first to fourth degree in severity as described in the coroner’s autopsy report. Postmortem carboxyhemoglobin (COHb), which is a measure of carbon monoxide exposure, was measured at 22% saturation and soot was observed in portions of her upper and lower respiratory system.

  • Based on the injuries sustained and the damage to Capt. Broxterman’s protective clothing ensemble and equipment, it is likely that she was exposed to a rapid intensification of heat and flames in the building’s basement that overwhelmed her protective ensemble and equipment, exposing her body and respiratory system to intense heat and toxic products of combustion.

 Ffr. Schira was a 29-year old employee of Colerain Fire & EMS with approximately 3½-years of certified firefighting experience. He also became trapped in the basement area for a prolonged amount of time following the sudden floor collapse. Ffr. Schira was found positioned on his right side and back, face-up beneath Capt. Broxterman. The majority of his protective clothing ensemble and equipment was heavily damaged as a result of exposure to heat and direct flame impingement. Ffr. Schira was pronounced deceased following his removal from the building. His body was transported to the Hamilton County Coroner’s Office for autopsy. The Coroner’s report cited the manner of death as “accidental” and the cause of death as “burns and inhalation of smoke and superheated and noxious gases”. Ffr. Schira sustained burns to 100% of his body surface, which ranged from first to fourth degree in severity as described in the coroner’s autopsy report. Postmortem COhb was measured at 8% saturation and soot was observed in portions of his upper and lower respiratory system.

  • Based on the injuries sustained and the damage to Ffr. Schira’s protective equipment, it is likely that that he was exposed to a rapid intensification of heat and flames in the building’s basement that overwhelmed his protective ensemble and equipment, exposing his body and respiratory system to intense heat and toxic products of combustion.

Select Findings and Recommendations

Findings, Discussions and Recommendations

FINDING #3.1: The area of fire origin had no finished ceiling, which exposed the floor joists and the underside of the floor decking to direct fire impingement causing rapid deterioration and failure of the flooring system directly underneath the main-level family room.

During this incident, based on communications transcripts (telephone and radio) it’s probable that the fire had advanced from its incipient stage to a free burning stage in approximately 18 to 20-minutes by the time Capt. Broxterman radioed that they were making entry into the basement.

  • As stated in the Incident Overview section, during the time period between 06:29:24 and 06:34:48, it is believed that one or more catastrophic events occurred within the building, which included a failure of the flooring system near the Beta-Charlie corner of the building’s first floor.

It has been widely believed in the firefighting profession that traditional sawn lumber is far superior to some of the more innovative lightweight construction components (e.g., wood I-joist) in use today. With dimensional lumber, two-inch by eight-inch and larger, there is a greater surface to mass ratio to resist the damaging effects of fire and the structural components will maintain their integrity for a longer period of time. While this has traditionally been accurate, this incident clearly shows that this may not always be the case. Heavy charring was evident to structural members in the fire area of origin. Notice the burn damage shows how the wooden floor joists had been burned to and away from the band joist. A band joist is a vertical member that forms the perimeter of a floor system in which the floor joists tie in to. Also known as the rim joist. Early platform framed homes very likely used solid, dimensional lumber and plywood, which provided a reasonable surface to mass ratio. But the later the home was built, the less mass even dimensional lumber has due to the reduction in the actual thickness of solid dimensional lumber provided by the lumber industry through the mid-1900’s. As the years go by, building materials will likely keep getting lighter and lighter and introduce more resins and other chemicals.

 Laboratory tests that exposed structural wood components to the American Society for Testing and Materials (ASTM) E119 Assembly Test indicated that a traditional two-inch by ten-inch structural member failed in 12-minutes and six-seconds. ASTM E119 test is the standard test method for evaluating building and construction materials exposed to fire. Unlike the standardized ASTM test fires, it is widely recognized that real building fires are highly variable in their size, rate of growth and intensity. Responding firefighters are unlikely to know when a given fire started, how hot it had been prior to arrival, how long it had been at any given temperature, the design capacity and actual loads on the floors over the fire or the amount of actual damage that the fire may have done to the joists. All of these factors make it impossible to predict the remaining capacity of a floor by even the most knowledgeable, professional fire experts.

RECOMMENDATION #3.1a: Fire departments should ensure that firefighters and incident commanders are aware that unprotected floor and ceiling joist systems, no matter the type, may fail at a faster rate when exposed to direct fire impingement.

Unfinished basement ceilings and other areas that have exposed joists or trusses jeopardize flooring and roof systems unnecessarily during a fire, causing premature failure. Often, a weakened floor and ceiling joist system can be difficult to detect from above as the floor surface above may still appear intact. Firefighters operating on floors above fire-damaged joist systems may fall through a weakened area and become trapped in a fire below. IC’s and firefighters must be aware that these systems can fail rapidly and without warning, and plan interior operations accordingly.

Firefighters must also be aware that while floor sag may be a widely accepted warning of an impending structural failure, floor sag is not always present or visible prior to a catastrophic collapse in a fire, regardless of the joist type, due to floor coverings, the fire’s intensity, the combination of joist spans and loads present, the location of serious structural fire damage or simply because it is too dark and smoky to see a sag in the floor. This is true for all types of structural joists, including materials such as sawn lumber, wood I-joists, and open web wood trusses and noncombustible members such as lightweight steel joists. The floor covering in this area was carpeting that transitioned to ceramic tile. When unprotected, any traditional or lightweight residential floor or ceiling assembly material, either combustible or noncombustible, may fail within several minutes of the fire’s ignition. It makes sense, therefore, that when there is a serious fire beneath a floor, there is no predictable safe amount of time that anyone can remain on that floor. Any floor system protected or not, can fail unpredictably when exposed to a substantial fire beneath.

FINDING # 4.2: E102′s officer failed to properly analyze the scene by not performing a 360-degree scene size-up to determine an overall strategy, and implement safe and effective firefighting tactics.

After the apparatus was positioned in front of the building, E102’s FAO was ordered by Capt. Broxterman to, “Ask the homeowner where the fire [location] was”, which was indicated to be in the basement by the male homeowner. As this was taking place, Capt. Broxterman continued donning her protective clothing ensemble (coat, helmet and self-contained breathing apparatus). Although E102′s officer provided a brief radio report of conditions observed upon arrival, she did not properly evaluate the scene so as to develop a basic strategy for implementation of safe and effective firefighting tactics. Had the officer visually evaluated the Charlie side of the building, the advanced fire conditions may have been noted, and that the lower level fire area was accessible by means of an exterior entry door for a more direct fire attack from the interior unburned side.

This means that firefighters enter a building and position the attack hose line between the fire and the uninvolved portions of the building. This direction of fire attack is preferred because it is likely to contain the fire, protect occupants, and push heat and gases out of the building if ventilation has been performed. On the other hand, danger increases significantly when attacking from the unburned side and is not always practical based on fire location, intensity, and building construction.

It cannot be conclusively known as to why Capt. Broxterman and Ffr. Schira proceeded into the area of the building that eventually collapsed resulting in their deaths. The investigation committee has concluded that the most probable explanation is that E102′s three-person interior team was successful in advancing their uncharged attack hose line into the basement recreation room area; reaching a point approximately 10 to15-feet from the bottom of the basement stairway as shown in the Incident Overview chapter. Once the team reached this area, it was realized they did not have sufficient hose line to continue advancing towards the seat of the fire. The team’s third member (Ffr. #2) reversed his travel and made his way back to the exterior of the building to advance additional hose line. As the team of two waited for additional hose line to be stretched and the hose line to be charged by the pump operator, the interior conditions rapidly deteriorated to a stage that it became untenable for them to hold their position.

The team evacuated back-up the stairway without following the hose line, which by all indications was tight up against the stairway wall and tightly wrapped around the stairway door entry. Once at the top of the stairway, one of the two deceased, if not both were likely in some form of distress; became disoriented and proceeded into the family room in a direction opposite the route of travel from which they entered the building. As the two moved across the family room floor, the flooring system collapsed into the utility room area of the basement. When the third team member re-entered the building, he was unable to locate the other two members.

The inability of Ffr. #2 to locate his team and the loss of radio communications contact with the interior team prompted the IC to declare a Mayday and activation of the RATs. This incident resulted in tragedy primarily due to the concealment of several burned-through floor joists under the carpet covered flooring system, which was nearly impossible to recognize due to heavy smoke conditions inside the burning building.

The following factors are believed to have directly contributed to the deaths that occurred in this incident:

  • The delayed arrival at the incident scene allowed the fire to progress significantly and the hazardous conditions to exponentially increase;
  • The failure to adhere to fundamental firefighting practices (e.g., entry into an enclosed building with obvious working fire conditions without a charged attack hose line)
  • The failure to abide by the fundamental concepts of fire fighter self-rescue and survival (e.g., following of the hose line in the direction of travel back to the building’s entrance or exit).

 Although the aforementioned factors are believed to have directly contributed to the deaths reported here, they might have been prevented if:

  • Some personnel had not been complacent or apathetic in their initial approach to this incident which eventually led to being overwhelmed in their response to their initial findings;
  • Some personnel were in a proper state of mind that made them more observant of their surroundings and indicators, and the potential threats and risks that presented themselves;
  • The initial responding units were provided with all pertinent information in a
  • timely manner relative to the incident, especially critical was the information  given to the emergency communications center from the homeowners reporting an actual fire
  • Personnel assigned to E102 possessed a comprehensive knowledge of their firstdue response area specifically related to road and street locations, and any particular characteristics related to those areas.
  • A 360-degree size-up of the building accompanied by a risk – benefit analysis was conducted by the company officer prior to initiating interior fire suppression operations; the risk of an action must be weighed against the probable benefit that may be reasonably and realistically expected.
  • Comprehensive standard operating guidelines specifically related to structural firefighting existed within the department;
  • The communications system users (on-scene firefighters and those monitoring the incident) weren’t all vying for limited radio air time. This competition led to missed and distorted messages and less than efficient use of resources, which exacerbated the problems of already taxed communications.
  • The communications equipment and accessories utilized were more appropriate for the firefighting environment;
  • Certain tactical-level decisions and actions were based on the specific conditions as encountered with an emphasis placed on fire ground tactical priorities (i.e., life safety, incident stabilization and property conservation);
  • Personnel had initiated fundamental measures to engage in if they were to become disoriented or trapped inside a burning building; and
  •  Issued personal protective equipment was utilized in the correct manner.

In Memory

The Colerain Township (OH) Department of Fire and Emergency Medical Services’s report examined the events of April 4th, 2008 with the benefit of hindsight, while seeking to be independent, impartial, and thorough. From the beginning, Colerain Fire & EMS has been committed to share our findings with others in the hope that it may prevent another such event.

The deaths of Captain Robin M. Broxterman and Firefighter Brian Schira had a profound loss not only to their parents, family and this organization, but also to the larger fire service community. In order to prevent these tragic losses in the future, we must first understand how and why our sister and brother firefighters died. We must learn from their incident and take that knowledge forward. If it was possible, what would these firefighters tell us today that might prevent a similar death of a firefighter in the future? What would they want us as firefighters, company officers and chief officers to know about the circumstances that lead to their deaths and the things we (and they) might have done to alter the most tragic of outcomes?  

From the information that was made available for review, it was evident that these two individuals were well-loved in life, and greatly missed in death. Every line of duty death of a firefighter in the United States is significant. This investigative analysis document is dedicated to Captain Broxterman and Firefighter Schira, their families, friends and the community whose lives were forever changed. In working to improve the health and safety of all United States firefighters, we have much to learn from the supreme sacrifice of these two individuals, who they were in life and in death. We honor their memories.

  

References

  • Colerain Township Department of Fire and Emergency Medical Services, Web Site HERE
  • Investigation Analysis of the Squirrels nest Lane Firefighter Line of Duty Deaths April, 2010 Full Report HERE
  • NIOSH Fire Fighter Fatality Investigation Report F2008-09| CDC/NIOSH July, 2009, Report HERE
  • WLTW.com news report Summary HERE

  

 

No More History Repeating Events-Remembrance

No comments

As we approach the July 4th holiday period, two significant LODD incidents previously occurred during this time frame that hold a number of lessons learned related to command management, operations, building construction principles and building performance, fire behavior and the ever present dangers of the job. Take the opportunity to learn more about these events, and expand your insights and knowledge base.  Those events being the 1988 Hackensack (NJ) Ford Fire which resulted in five (5) LODD and the 2002 Gloucester City (NJ) Fire that resulted in three (3) LODD along with three children.

Take a moment to reflect upon the supreme sacrifice made by these heroic firefighters and the messages that lay within the pages of the incident case studies, reports and summaries.  Our sister site TheCompanyOfficer.com   has a comprehensive overview of both events with report links and a must see video on the Gloucester City (NJ) 2002 LODD event. For Remembering Hackensack and Gloucester follow the link HERE

Remembrance (1988)

Hackensack (NJ) Fire Department
• CAPT. RICHARD L. WILLIAMS, Engine Co. No. 304
• LIEUT. RICHARD REINHAGEN, Engine Co. No. 302
• F/F WILLIAM KREJSA, Engine Co. No. 301
• F/F LEONARD RADUMSKI, Engine Co. No. 302
• F/F STEPHEN ENNIS, Rescue Co. No. 308
  

Remember (2002)

Gloucester City (NJ) Fire
• James Sylvester Fire Chief, Mount Ephraim Fire Department
• John West Deputy Chief, Mount Ephraim Fire Department
• Thomas G. Stewart III Paid Firefighter, Gloucester City Fire Department

Building Knowledge=Firefighter Safety

1 comment

Commandsafety.com is pleased to make available the latest update to the Buildingsonfire.com’s Building Construction Training and Lecture Series for 2010. Recently updated with a series of new seminar and training program topics addressing the emerging training and educational needs of the fire service, these programs provide timely and relevant information and insights on Building Construction, Command Risk Management, Dynamic and Extreme Fire Behavior, Occupancy Situational Awareness, Engineered Structural Systems and Fire Fighter Safety.

These programs also present and integrate cutting edge research and emerging concepts on Tactical Patience, Tactical Entertainment, Command Compression, Structural Anatomy of Buildings, Five Star Command Model, Predicative Strategic Process, refined Tactical Deployment Models integrating intelligent Structural Anatomy and Predictive Occupancy Profiling and much more.  

These programs, lectures and seminars examine crucial construction elements and occupancy types and correlates building construction performance toward combat structural fire suppression operations. Case studies will reinforce concepts presented and evoked open discussion and dialog on building construction and operational safety. These fast paced programs will utilize extensive multimedia materials, interactive activities, case study activities and simulations to reinforce course content and subject areas, providing exceptional learning opportunities.

Without understanding the building-occupancy relationships and integrating; construction, occupancies, fire dynamics and fire behavior, risk, analysis, the art and science of firefighting, safety conscious work environment concepts and effective and well-informed incident command management, company level supervision and task level competencies…You are derelict and negligent and “not “everyone may be going home”. Our current generation of buildings, construction and occupancies are not as predictable as past conventional construction; risk assessment, strategies and tactics must change to address these new rules of structural fire engagement. There is a need to gain the building construction knowledge and insights and to change and adjust operating profiles in order to safe guard companies, personnel and team compositions. It’s all about understanding the building-occupancy relationships and the art and science of firefighting, Building Knowledge = Firefighter Safety (Bk=F2S)

Down load the program files from the link below for more information.

Building Construction Training Programs 2010

 

Taking it to the Streets

1 comment

Coming July 2010

The Summer Tour is about to Begin..

Taking it to the Streets

With Christopher Naum

A New Monthly Radio Talkshow on FireFighter Netcast.com

A Buildingsonfire.com Series and FireFighter Netcast.com Production

Advancing FireFighter Safety and Operational Intergrity for the Fire Service through provocative insights and dynamic discussions dedicated to the Art and Science of Firefighting and the Traditions of the Fire Service.

Watch for the Latest Announcements here on CommandSafety.com, TheCompanyOfficer.com and on Firefighter Netcast.com

Programming

Ten Minutes in the Street

  • Presenting an informational recap and discussion on leading topcs, events and issues from the past 30 days.

Feature Segments Program will have one (1) selected segment based upon topic and guest

Buildingsonfire

  • Addressing today’s topical issues within the areas of Firefighting, Building Construction, Dynamic Risk Assessment, and Command & Tactical Safety
    • Open interative discussions and call-in
  • Street Stories
    • Presenting first-hand accounts and insights on an event, response or operation with a featured guest
    • Open interative discussions and call-in
  • Smoke Showin’
    • Featured Guest Interviews and discussions focusing on the NFFF Firefighter Life Safety Initiatives and Everyone Goes Home Campaign
    • Open interative discussions and call-in

HRE History Repeating Events

  • Discussion on recent History Repeating Events, LODD, NIOSH Reports or other
  • Open interative discussions and call-in

A View from the Street

  • Closing Commentary on timely and relevant issues affecting the Fire Service